Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Fisioter. pesqui ; 19(2): 153-157, abr.-jun. 2012. tab
Artigo em Português | LILACS | ID: lil-644515

RESUMO

O objetivo deste estudo foi verificar o efeito bactericida do gerador de alta frequência sobre a cultura de Staphylococcus aureus. Para isso, 36 placas de Petri inoculadas com Staphylococcus aureus foram divididas em 6 grupos, sendo 4 tratados (G5-15, G5-10, G3-15 e G3-10) e 2 controles (GC3 e GC5). O G5-15 e o G5-10 foram tratados 5 vezes por semana durante 15 e 10 minutos respectivamente, enquanto o G3-15 e o G3-10 foram tratados 3 vezes por semana durante 15 e 10 minutos respectivamente. No tratamento, foi utilizado o gerador de alta frequência na intensidade 10, técnica de faiscamento com eletrodo standard. Após o 15º dia de tratamento, foram realizadas repicagens para verificar se houve crescimento de novas culturas, observando-se que apenas o G5-15 mostrou-se eficaz quando comparado ao GC5 (p=0,0039). Assim, o gerador de alta frequência apresentou efeito bactericida diante de cultura de Staphylococcus aureus in vitro em uma frequência de 5 vezes por semana aplicado por 15 minutos diários.


The purpose of this study was to check the bactericidal effect of the high frequency generator over the Staphylococcus aureus culture. A total of 36 Petri dishes inoculated with Staphylococcus aureus were divided into 6 groups, including 4 treated (G5-15, G5-10, G3-15 and G3-10) and 2 controls (GC3 e GC5). G5-15 and G5-10 were treated 5 times per week during 15 and 10 minutes, respectively, while G3-15 and G3-10 were treated 3 times per week during 15 and 10 minutes, respectively. In treatment, it was used the high frequency generator with intensity of 10, sparking technique with standard electrode. After the 15th day of treatment, there were performed transplanting, in order to check if there were growth of new cultures, and only G5-15 showed to be effective when compared to GC5 (p=0.0039). So, the high frequency generator had a bactericidal effect on Staphylococcus aureus in vitro culture at a frequency of 5 times per week and exposure time of 15 minutes daily.


Assuntos
Antibacterianos , Crescimento Bacteriano , Meios de Cultura , Radiação Eletromagnética , Fontes Geradoras de Energia , Técnicas In Vitro , Ozônio , Modalidades de Fisioterapia , Staphylococcus aureus/crescimento & desenvolvimento , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA