Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 175
Filtrar
1.
Odontology ; 2024 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-39283508

RESUMO

This study evaluated the influence of the apical limit and the diameter of the instrumentation on the extrusion of the irrigating solution. Sixty human lower premolars were distributed into 5 groups according to the apical limit and diameter of the root canal instrumentation (n = 12): (G-140) R40 instrument 1 mm above the tooth length (TL) (Control); (G-150) R50 instrument 1 mm above the TL; (GF25) R25 instrument at the TL; (GF40) R40 instrument at the root canal length and (GF50) R50 instrument at the TL. A space of 33.5 ± 1 mm3 was created for storage of the extruded solution. Omnipaque contrast was added to the NaOCl solution in a 1:2 ratio, totaling 15 mL of solution to allow its visualization when extruded in microcomputed tomography. Final irrigation was performed with a syringe and needle and activated with a passive ultrasonic irrigation (PUI). Three activation cycles were performed. Data were tabulated and statistically analyzed (one-way ANOVA) with a significance level set at 5%. It was observed irrigating solution extrusion after final irrigation in all groups. However, there were no statistically significant differences among experimental groups, regardless of the diameter or apical limit of root canal instrumentation (p > 0.05). The different apical limits and diameters of root canal instrumentation did not influence the volume of extruded irrigating solution using passive ultrasonic irrigation.

2.
Aust Endod J ; 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39162044

RESUMO

Endodontic microsurgery guided by navigation systems represents a precise and minimally invasive approach for retreatment of apical periodontitis following failed conventional endodontic therapy. Accurate localization and minimal access to the root apex are paramount for successful outcomes and preservation of anatomical structures. Workflow considerations, such as three-dimensional (3D) virtual planning and endodontic guidance represent new crucial aspects for addressing complex cases. This clinical case report presents the successful reintervention of a complex case using a Zekrya bur, operative microscopy, cone beam computed tomography and biocompatible materials. After a 48-month follow-up, complete healing of the treated area was observed. This minimally invasive technique, employing a simple instrument widely available globally, underscores the potential for efficient and predictable outcomes in complex endodontic microsurgical retreatment.

3.
Int Endod J ; 57(11): 1669-1681, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39080736

RESUMO

AIM: The present study investigated the influence of apical periodontitis (AP) on the severity of rheumatoid arthritis (RA) using a Wistar rat model. METHODOLOGY: Forty male Wistar rats were distributed across four groups (n = 10) based on the induction of RA and AP: Control, RA, AP, and RA + AP. RA was induced through two immunisations with type II collagen emulsified in incomplete Freund's adjuvant, followed by one immunisation with complete Freund's adjuvant. After 21 days of RA induction, AP was induced by exposing the pulp of four molars. Animals were euthanized after 28 days of pulp exposure. Through the experiment, visual and behavioural assessments tracked RA development and the knees and hind paw joints were measured. Micro-computed tomography scans of knees and hind paws, as well as mandibles and maxillae, were conducted to evaluate RA severity and the presence of AP, respectively. Serum samples were collected to analyse proinflammatory cytokines (IL-1ß, IL-2, IL-17, and TNF-α). Non-parametric data were analysed using the Kruskal-Wallis test followed by Student-Newman-Keuls test, while one-way anova followed by Tukey's test was performed for parametric data. A significance level of 5% was employed. RESULTS: All molars submitted to access cavity developed AP. All joints subjected to arthritis induction developed the disease, with AP + RA demonstrating a higher arthritis severity when compared to the RA group (p < .05). RA + AP group displayed a significantly larger hind paw and knee circumference compared to the RA group (p < .05). Micro-CT images of RA and RA + AP groups revealed joints with erosions and bone deformities, with a significantly lower bone surface density, lower trabecular number and higher trabecular separation in the hind paw and a significantly lower percent bone volume and higher trabecular separation in the knees of RA + AP group compared to RA group (p < .05). RA + AP group exhibited a significantly higher level of TNF-α and a lower level of IL-2 compared to all other groups (p < .05). Both RA and RA + AP groups had significantly higher IL-17 levels (p < .05), while there was no significant difference in IL-1ß levels among the groups (p > .05). CONCLUSION: The findings from this study underscore a possible relationship between apical periodontitis and the exacerbation of rheumatoid arthritis.


Assuntos
Artrite Reumatoide , Modelos Animais de Doenças , Periodontite Periapical , Ratos Wistar , Microtomografia por Raio-X , Animais , Masculino , Periodontite Periapical/diagnóstico por imagem , Periodontite Periapical/patologia , Ratos , Índice de Gravidade de Doença , Fator de Necrose Tumoral alfa/sangue , Citocinas/metabolismo , Artrite Experimental/patologia , Artrite Experimental/diagnóstico por imagem , Interleucina-1beta/sangue , Interleucina-2/sangue , Interleucina-17
4.
J Endod ; 50(9): 1333-1339, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38901643

RESUMO

INTRODUCTION: The purpose of this study was to evaluate whether the mixing method of AH Plus Jet sealer affects its physicochemical and mechanical properties. METHODS: The properties of AH Plus Jet sealer were analyzed when mixed using either the Auto Mix Tip or manual mixing. The evaluated properties included radiopacity (n = 5), initial and final setting times (n = 5), flow (n = 5), and solubility (n = 3), following specifications outlined in ISO 6876/2012 and ADA Nº 57/2000. pH levels were measured at intervals of 3, 24, 72, and 168 hours (n = 10). The push-out bond strength test was conducted using a universal testing machine and using bovine teeth (n = 30). Failure modes were analyzed with stereomicroscopy. Porosity was evaluated under micro-CT (n = 5), and scanning electron microscopy was also performed (n = 5). One-way analysis of variance and Tukey, unpaired t-tests, or Mann-Whitney tests were used with a significance level of 5%. RESULTS: The Auto Mix exhibited a radiopacity value of 12.11 mmAl, whereas manual mixing resulted in 12.55 mmAl (P > .05). For initial and final setting times, Auto Mix showed 901 minutes and 1779 minutes, respectively, while manual mixing recorded values of 631 minutes and 1504 minutes (P < .05). In terms of flow, Auto Mix demonstrated higher values (25.26 mm) than manual mixing (21.71 mm) (P < .05). No statistical differences were observed between the two methods for solubility and pH (P > .05). Manual mixing presented a higher bond strength value (14.52 MPa) than Auto Mix (9.81 MPa) (P < .05). The mixed failure mode was the most frequent outcome for both methods. The highest porosity was observed for Auto Mix (P < .05). Scanning electron microscopy analysis revealed that manual mixing resulted in a smoother surface with fewer pores and smaller, more evenly distributed agglomerates compared to automatic mixing. CONCLUSION: The mixing method employed for AH Plus Jet sealer influences some physicochemical and mechanical properties of the material.


Assuntos
Resinas Epóxi , Teste de Materiais , Materiais Restauradores do Canal Radicular , Materiais Restauradores do Canal Radicular/química , Bovinos , Animais , Resinas Epóxi/química , Microscopia Eletrônica de Varredura , Solubilidade , Concentração de Íons de Hidrogênio
5.
Eur Endod J ; 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38820458

RESUMO

Assessing scientific literature about prevalence of periapical lesions in individuals with osteoporosis in comparison to those without osteoporosis. Systematic searches were conducted up to November 24th, 2023 in Cochrane Library, EMBASE, MEDLINE/PubMed, SCOPUS, Web of Science and Grey Literature Reports databases. Only observational studies were included. The ROBINS-E tool, a revised Cochrane instrument for assessing bias in nonrandomized exposure studies, was employed. The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) tool was utilized to evaluate the certainty of the evidence. From 484 studies, three were included. One of them was categorized as having an exceptionally high risk of bias, while two were deemed to have certain concerns. Two studies reported that osteoporotic patients may have more chances to present a periapical lesion compared to non-osteoporotic patients. One study reported no differences between groups. The GRADE analysis indicated a markedly low level of certainty in the evidence. The present review indicates that osteoporotic patients may present more periapical lesions compared to non-osteoporotic patients. This statement should be cautiously interpreted and further well-designed studies are needed. (EEJ-2023-09-123).

6.
Aust Endod J ; 50(2): 341-351, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38715465

RESUMO

This study assessed canal preparation effects on disinfection and dentin preservation. Thirty mandibular incisors were paired into two experimental groups (n = 10). Following contamination, the initial microbial sample was collected. Instruments 30/0.03 (Group 1) and 30/0.05 (Group 2) were employed and a second sample was obtained. Canals were enlarged using instruments 40/0.03 and 40/0.05, respectively, and a third sample was collected. Final irrigation was performed, and sample S4 obtained. A final scan evaluated volume, surface area, unprepared areas, removed dentin and dentin thickness. Data were analysed using Student t-test, Mann-Whitney, Kruskal-Wallis and Dunn tests. A significant difference was observed between S1 and other time points (p < 0.05). Comparison between groups showed no differences in bacterial loads and in the percentage of microbial reduction (p > 0.05). Group 2 exhibited greater reduction in dentin thickness than group 1 in the mesial aspect of the root (p < 0.05). Instrument 30/0.03 might provide effective disinfection and safety during mandibular incisors canal preparation.


Assuntos
Desinfecção , Incisivo , Mandíbula , Preparo de Canal Radicular , Humanos , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Desinfecção/métodos , Cavidade Pulpar/microbiologia , Desenho de Equipamento , Dentina/microbiologia , Carga Bacteriana
7.
Aust Endod J ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747371

RESUMO

This study assessed the mechanical properties of the Only One File Blue and the Reciproc Blue instruments. A total of 80 new 25 mm reciprocating NiTi instruments (25/.08v) were evaluated for their mechanical performance (n = 40 per group). Cyclic fatigue resistance, torsional fatigue, flexural resistance and buckling resistance tests were conducted. Statistical analysis was employed with a significance level set at 5%. The results indicated no statistically significant differences in resistance to cyclic fatigue neither in the fragment length between the instruments (p > 0.05). However, the Reciproc Blue instrument exhibited greater torque to fracture and a larger rotation angle than the Only One File Blue instrument (p < 0.05). The Only One File Blue instrument demonstrated higher flexibility but lower resistance to buckling compared to the Reciproc Blue instrument (p < 0.05). In conclusion, the tested instruments exhibit differences in mechanical properties, with the Reciproc Blue instrument generally presenting greater advantages than the Only One File Blue.

8.
Int Endod J ; 57(5): 601-616, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38376108

RESUMO

AIM: To compare eight large- and low-tapered heat-treated reciprocating instruments regarding their design, metallurgy, mechanical properties, and irrigation flow through an in silico model. METHODOLOGY: A total of 472 new 25-mm E-Flex Rex (25/.04 and 25/.06), Excalibur (25/.05), Procodile (25/.06), Reciproc Blue R25 (25/.08v), WaveOne Gold Primary (25/.07v), and Univy Sense (25/.04 and 25/.06) instruments were evaluated regarding their design (stereomicroscopy, scanning electron microscopy, and 3D surface scanning), metallurgy (energy-dispersive X-ray spectroscopy and differential scanning calorimetry), and mechanical performance (cyclic fatigue, torsional resistance, cutting ability, bending and buckling resistance). Computational fluid dynamics assessment was also conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparations. Kruskal-Wallis and one-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Instruments presented variations in blade numbers, helical angles, and tip designs, with all featuring non-active tips, symmetrical blades, and equiatomic nickel-titanium ratios. Cross-sectional designs exhibited an S-shaped geometry, except for WaveOne Gold. Univy 25/.04 and Reciproc Blue displayed the smallest and largest core diameters at D3. Univy 25/.04 and E-Flex Rec 25/.04 demonstrated the longest time to fracture (p < .05). Reciproc Blue and Univy 25/.04 exhibited the highest and lowest torque to fracture, respectively (p < .05). Univy 25/.04 and Reciproc Blue had the highest rotation angles, whilst E-Flex Rec 25/.06 showed the lowest angle (p < .05). The better cutting ability was observed with E-Flex Rec 25/.06, Procodile, Excalibur, and Reciproc Blue (p > .05). Reciproc R25 and E-Flex Rec showed the highest buckling resistance values (p < .05), with WaveOne Gold being the least flexible instrument. The impact of instruments' size and taper on wall shear stress and apical pressure did not follow a distinct pattern, although Univy 25/.04 and E-Flex Rec 25/.06 yielded the highest and lowest values for both parameters, respectively. CONCLUSIONS: Low-tapered reciprocating instruments exhibit increased flexibility, higher time to fracture, and greater angles of rotation, coupled with reduced maximum bending loads and buckling strength compared to large-tapered instruments. Nevertheless, low-tapered systems also exhibit lower maximum torque to fracture and inferior cutting ability, contributing to a narrower apical canal enlargement that may compromise the penetration of irrigants in that region.


Assuntos
Instrumentos Odontológicos , Titânio , Estudos Transversais , Desenho de Equipamento , Teste de Materiais , Estresse Mecânico , Titânio/química , Preparo de Canal Radicular , Metalurgia
9.
Aust Endod J ; 50(2): 260-266, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38243635

RESUMO

This study evaluated the impact of canal irrigation using surfactants associated to NaOCl on the percentage of voids of root canal filling through micro-computed tomographic (micro-CT) analysis. 27 mandibular mesial roots with Vertucci type II canal configuration with isthmus were selected and scanned in a micro-CT device. The specimens were assigned to three groups (n = 9), according to the irrigation solution during instrumentation: 2.5% NaOCl without additives (control), 2.5% NaOCl with 0.1% Benzalkonium Chloride and 2.5% NaOCl with 0.1% Tween 80. After obturation, the specimens were rescanned, and the percentage of voids were calculated. Data were analysed using one-way ANOVA with a significance level of 5%. The percentage of voids were similar among the groups (p > 0.05). None of the specimens showed completely voids-free areas. The addition of surfactants to NaOCl irrigation did not improve the quality of root canal filling of mandibular mesial root canals.


Assuntos
Irrigantes do Canal Radicular , Hipoclorito de Sódio , Tensoativos , Microtomografia por Raio-X , Hipoclorito de Sódio/farmacologia , Tensoativos/farmacologia , Irrigantes do Canal Radicular/farmacologia , Humanos , Microtomografia por Raio-X/métodos , Compostos de Benzalcônio/farmacologia , Obturação do Canal Radicular/métodos , Cavidade Pulpar/efeitos dos fármacos , Preparo de Canal Radicular/métodos , Irrigação Terapêutica/métodos
10.
Aust Endod J ; 50(1): 60-68, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37876340

RESUMO

This study evaluated the impact of long-term storage conditions (medium and time) on the development of experimental dentinal microcracks through micro-computed tomography. Sixty freshly extracted premolars were stored in formalin, water, or dry conditions (n = 20) and scanned after 72 h, 30 days, 6 months and 3 years of extraction. The effect of the storage medium and time on the occurrence of dentinal defects was statistically evaluated. A total of 211 000 images were screened revealing the existence of 11 519 slices with dentinal defects. Dry conditions significantly contributed to the development of new defects in all time points. During the 3-year follow-up period, no new defects were detected in the teeth that were stored in water and, in a single tooth, in the formalin group, after 6 months of storage.


Assuntos
Fraturas dos Dentes , Humanos , Dentina/diagnóstico por imagem , Microtomografia por Raio-X , Preparo de Canal Radicular , Água , Formaldeído
11.
Int Endod J ; 57(2): 178-194, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37966374

RESUMO

AIM: To assess the periapical alveolar bone pattern and the serum levels of proinflammatory cytokines, biochemical markers and metabolites in rats subjected to chronic alcohol and nicotine consumption and induced apical periodontitis. METHODOLOGY: Twenty-eight male Wistar rats were divided into four groups: Control, Alcohol, Nicotine and Alcohol+Nicotine. The alcohol groups were exposed to self-administration of a 25% alcohol solution, while the other groups were given only filtered water. The nicotine groups received daily intraperitoneal injections of a nicotine solution (0.19 µL of nicotine/mL), whereas the other groups received saline solution. Periapical lesions were induced by exposing the pulps of the left mandibular first molars for 28 days. After euthanasia, the mandibles were removed and the percentage bone volume, bone mineral density, trabecular thickness, trabecular separation and trabecular number of the periapical bone were measured using micro-computed tomography images. Serum samples were collected for analysis of proinflammatory cytokines (IL-1ß, IL-4, IL-6 and TNF-α), biochemical and metabolomic analysis. Statistical analysis was performed with a significance level of 5%. Nonparametric data were analysed using the Kruskal-Wallis test followed by Dunn's test, while one-way anova followed by Tukey's test was performed for parametric data. RESULTS: The groups exposed to alcohol or nicotine consumption exhibited an altered bone pattern indicating lower bone density and higher levels of IL-1ß, IL-6 and TNF-α compared to the Control group (p < .05). Significant differences were observed among the groups in the levels of aspartate aminotransferase (AST), alanine aminotransferase (ALT), alkaline phosphatase, cholesterol, triglycerides, urea, creatinine, albumin, uric acid, bilirubin and calcium. Metabolomic analysis revealed significant differences in glycine, phosphocholine, lysine, lactate, valine, pyruvate and lipids (CH2 CH2 CO), n(CH2 ) and n(CH3 ). Most of these parameters were even more altered in the simultaneous consumption of both substances compared to single consumption. CONCLUSION: Alcohol and nicotine chronic consumption altered several metabolic markers, impaired liver and kidney function, increased the production of systemic proinflammatory mediators and harmed the periapical bone microarchitecture in the presence of apical periodontitis. The simultaneous consumption of alcohol and nicotine intensified these detrimental effects.


Assuntos
Nicotina , Periodontite Periapical , Ratos , Masculino , Animais , Ratos Wistar , Nicotina/farmacologia , Microtomografia por Raio-X , Interleucina-6 , Fator de Necrose Tumoral alfa , Etanol , Interleucina-1beta
13.
Restor Dent Endod ; 48(4): e37, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38053784

RESUMO

This study aimed to compare the disinfectant ability of chlorhexidine (CHX) gel and sodium hypochlorite (NaOCl). Systematic searches were conducted from inception until December 8th, 2022 (MEDLINE/PubMed, Cochrane Library, Web of Science, Scopus, Embase, and Grey Literature databases). Only randomized clinical trials were included. The revised Cochrane risk of bias tools for randomized trials were used to assess the quality of studies. Meta-analyses were performed. The overall quality of evidence was assessed through the Grading of Recommendations Assessment, Development, and Evaluation tool. Six studies were included. Five had a low risk of bias and 1 had some concerns. Three studies assessed bacterial reduction. Two were included in the meta-analysis for bacterial reduction (mean difference, 75.03 [confidence interval, CI, -271.15, 421.22], p = 0.67; I2 = 74%); and 3 in the meta-analysis for cultivable bacteria after chemomechanical preparation (odds ratio, 1.03 [CI, 0.20, 5.31], P = 0.98; I2 = 49%). Five studies assessed endotoxin reduction. Three were included in a meta-analysis (mean difference, 20.59 [CI, -36.41, 77.59], p = 0.48; I2 = 74%). There seems to be no difference in the disinfectant ability of CHX gel and NaOCl, but further research is necessary.

14.
J Endod ; 2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37633518

RESUMO

INTRODUCTION: Bisphosphonates are antiresorptive drugs used worldwide to treat systemic bone pathologies. This study aimed to assess the impact of zoledronic acid on the progression of induced apical periodontitis and the expression of cytokines interleukin (IL)-1ß, IL-10, IL-6, and tumor necrosis factor alpha (TNF-α) in a mouse model. METHODS: Sixteen female isogenic BALB/c mice 6 weeks of age were distributed into 2 groups: mice with induced apical periodontitis (the AP group, n = 8) and mice with induced apical periodontitis treated with zoledronic acid (the AP-ZA group, n = 8). The AP-ZA group received a dose of 125 µg/kg zoledronic acid diluted in sterile saline solution administered intraperitoneally once a week for 4 weeks before pulp exposure, whereas the AP group received only saline solution. Pulp exposures were performed on the maxillary first molars for the induction of apical periodontitis, and mice were euthanized after 7 and 21 days. The jaws were collected; scanned using micro-computed tomographic imaging; and processed for polymerase chain reaction analysis of IL-1ß, IL-10, IL-6, and TNF-α. The Student t test was performed for parametric data, and Mann-Whitney U tests were used for nonparametric data. The level of significance was set at 5%. RESULTS: Micro-computed tomographic imaging revealed higher bone resorption in the AP group compared with the AP-ZA group at both time points (P < .05). Real-time polymerase chain reaction demonstrated higher TNF-α expression in the AP group at both time points and higher IL-6 and IL-1ß expression in the AP group at the 7- and 21-day time points, respectively, compared with the AP-ZA group (P < .05). No differences were observed regarding IL-10 expression between the groups. CONCLUSIONS: Zoledronic acid had significant anti-inflammatory and antiresorptive effects on apical periodontitis in mice.

15.
Aust Endod J ; 49(3): 700-710, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37489612

RESUMO

This study evaluated unprepared canal areas, volume of dentine removal, and dentine thickness after the progressive enlargement of the buccal canals of 22 maxillary molars, with and without the MB2, using instruments with the same tip size (0.25 mm) but 4 different tapers (0.03, 0.05, 0.06 and 0.08 v). Micro-CT scans were performed after each instrument. Data were compared using a general linear mixed model post hoc comparisons with Kenward-Roger for Wald F tests (α = 5%). After each treatment step, it was observed an increase in the percentage volume of removed dentine and a decrease in the unprepared areas and dentine thickness at the pericervical region of all canals (p < 0.05). The percentage reduction of dentine thickness in MB2 canal was higher than in the mesiobuccal and distobuccal canals (p < 0.05). Knowledge of pre-operative dimensions and dentine thickness before enlargement of buccal canals of maxillary molars is an important factor to avoid excessive dentine removal.


Assuntos
Cavidade Pulpar , Dente Molar , Humanos , Microtomografia por Raio-X , Cavidade Pulpar/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Hipertrofia , Conhecimento , Preparo de Canal Radicular
16.
BMC Oral Health ; 23(1): 385, 2023 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-37308853

RESUMO

BACKGROUND: Considering the irregular shape of the root canal, removing inflamed pulp and granulation tissue completely from internal resorption cavities during chemomechanical preparation can be challenging. This study aimed to evaluate the effectiveness of passive ultrasonic irrigation (PUI) compared to mechanical activation with Easy Clean in the removal of organic tissue from simulated areas of internal root resorption. METHODS: The root canals of 72 extracted single-rooted teeth with oval canals were instrumented with Reciproc R25 instruments. After root canal preparations, the specimens were split longitudinally, and semicircular cavities were prepared using a round bur on each half of the roots. Samples obtained from bovine muscle tissue were weighed and adapted into semicircular cavities. The roots were reassembled and joined, and the teeth were divided into six groups (n = 12) according to the irrigation protocol: Sodium hypochlorite (NaOCl) without activation; NaOCl + PUI; NaOCl + Easy Clean; distilled water without activation; distilled water + PUI; and distilled water + Easy Clean. After irrigation protocols, the teeth were disassembled, and the remaining organic tissue was weighed. Data were analyzed by two-way ANOVA and Tukey's post hoc test (p < 0.05). RESULTS: None of the experimental protocols totally removed the bovine tissue from simulated cavities. Tissue weight reduction was significantly affected by the activation method (p < 0.05) and by irrigation solution (p < 0.05). Groups with NaOCl irrigation presented higher tissue weight loss when compared to distilled water, for all irrigation methods (p < 0.05). The use of Easy Clean resulted in the greatest tissue weight loss (42.0%-Distilled water/45.5%- NaOCl) compared to those of PUI (33.3%-Distilled water/37.7%- NaOCl) and no activation (33.4%-Distilled water/38.8%- NaOCl) (p < 0.05). However, no differences were observed between PUI and no activation groups (p > 0.05). CONCLUSIONS: Mechanical activation with Easy Clean enhanced organic tissue removal from simulated internal resorption more effectively than PUI. Easy Clean for agitation of the irrigating solution is effective in removing simulated organic tissues from artificial internal resorption cavities, being an alternative to the use of PUI.


Assuntos
Cárie Dentária , Reabsorção da Raiz , Humanos , Animais , Bovinos , Análise de Variância , Polpa Dentária , Preparo de Canal Radicular
17.
J Endod ; 49(5): 487-495, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36848949

RESUMO

INTRODUCTION: This study aimed to compare the in vivo accuracy and precision of 3 electronic apex locators (EALs) in determining the position of the major foramen using micro-computed tomographic (micro-CT) technology. METHODS: After access preparation of 23 necrotic or vital teeth from 5 patients, canals were negotiated, and hand files were used to determine the position of the foramen with 3 EALs: Propex Pixi (Dentsply Maillefer, Ballaigues, Switzerland), Woodpex III (Woodpecker Medical Instrument Co, Guilin, China), and Root ZX II (J Morita, Tokyo, Japan). After fixing the silicon stop to the file, teeth were extracted and scanned in a micro-CT device with and without the instrument inserted into the canal. Data sets were coregistered, and the accuracy and precision of the EALs were determined at a tolerance level of ±0.5 mm by measuring the distance from the tip of the instruments to a tangential line crossing the margins of the foramen. Statistical comparisons were performed using Friedman with post hoc related samples sign and Spearman tests (α = 5%). RESULTS: A significant difference was detected comparing the accuracy of Root ZX II (100%), Woodpex III (86.96%), and Propex Pixi (52.17%) (P < .05). There was a lack of significance in the relationship between the pulp status and the accuracy of the tested EALs (P > .05). Propex Pixi was significantly less precise than Root ZX II (P < .05), whereas no difference was found between Woodpex III and Root ZX II or Propex Pixi (P > .05). CONCLUSIONS: EALs presented similar precision, but Woodpex III and Root ZX II showed better accuracy to determine the position of the apical major foramen than Propex Pixi.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Humanos , Cavidade Pulpar/diagnóstico por imagem , Odontometria , Ápice Dentário/diagnóstico por imagem , Eletrônica
18.
Aust Endod J ; 49 Suppl 1: 194-201, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36401559

RESUMO

This study assessed the influence of pH variation on the volumetric change of EndoSequence BC Sealer compared to AH Plus Jet. Eighteen single-rooted teeth were uniformly prepared and filled with one of the sealers. After 24-h storing, samples were scanned in a micro-CT device. Then, roots were immersed in 20 ml phosphate-buffered saline (PBS) with pH of 5, 7 or 12 at 37°C for 7 and 30 days and rescanned. Statistical analysis was performed using Shapiro-Wilk's test, one-way ANOVA and Tukey's or Student's t-tests (p < 0.05). Differences between sealers were observed only at neutral pH and after 30 days of acidic pH exposure, with a higher loss of EndoSequence (p < 0.05). After 7 days, alkaline pH reduced and increased the volumetric loss of EndoSequence and AH Plus, respectively, compared to neutral pH (p < 0.05). It can be concluded that the pH directly influenced the volumetric change of both tested root canal sealers in different ways.


Assuntos
Resinas Epóxi , Materiais Restauradores do Canal Radicular , Humanos , Microtomografia por Raio-X , Compostos de Cálcio , Silicatos , Concentração de Íons de Hidrogênio , Teste de Materiais , Cavidade Pulpar/diagnóstico por imagem
19.
Braz. dent. j ; Braz. dent. j;33(3): 38-46, July-Sept. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1384033

RESUMO

Abstract This study evaluated the Reciproc R25 and Pro-R 25 instruments in unused condition, after one and a second use in endodontic retreatment employing a noncontact 3D light interferometer profiler, scanning electron microscopy (SEM) and cyclic fatigue tests. Twenty single-root teeth were instrumented with Reciproc R25 and filled with gutta-percha and sealer. A 3D profiler with a 20x objective using the Mx™ software was used to evaluate the cutting blade surfaces of Reciproc R25 and Pro-R 25 (n=5 per group) in unused condition, after the first and second uses in retreatment procedures. After retreatment, SEM was used to evaluate the topographic features of the used instruments. Cyclic fatigue tests were performed to compare new to used instruments. One-way ANOVA followed by Tukey test was used to compare the tested instruments before and after the first and second uses. Student t-test was used to compare the different instruments and for cyclic fatigue evaluation. No significant differences were observed in the cutting blade surfaces of Reciproc and Pro-R before and after one and two uses (p>0.05). Reciproc without use showed higher Sa and Sq when compared to Pro-R without use (p<0.05). No differences were observed between Reciproc and Pro-R after one and two uses (p>0.05). New and unused Reciproc showed longer time to fracture than Pro-R instruments (p<0.05), and only Pro-R showed differences between new and used instruments (p<0.05). Retreatment procedures with Reciproc and Pro-R did not change the surface topography of instruments. Reciproc had greater resistance to cyclic fatigue compared with Pro-R.


Resumo Este estudo avaliou os instrumentos Reciproc R25 e Pro-R 25 sem uso, após um primeiro e um segundo uso em retratamento endodôntico com perfilômetro 3D por interferometria de luz sem contato, microscópio eletrônico de varredura (MEV) e testes de fadiga cíclica. Vinte dentes unirradiculares foram instrumentados com Reciproc R25 e obturados com guta-percha e cimento endodôntico. Um perfilômetro 3D com uma objetiva 20x usando o software Mx ™ foi usado para avaliar as superfícies da lâmina de corte do Reciproc e Pro-R (n = 5 por grupo) na condição sem uso, após o primeiro e após um segundo uso em procedimentos de retratamento. Após retratamento, o MEV foi usado para avaliar as características topográficas dos instrumentos utilizados. Testes de fadiga cíclica foram realizados para comparar instrumentos novos com instrumentos usados. O teste One-way ANOVA seguido pelo teste de Tukey foi usado para comparar os instrumentos testados nos diferentes estágios. Para comparar os diferentes instrumentos e para avaliação de fadiga cílcica, foi utilizado o Student t-test. Não foram observadas diferenças estatisticamente significantes nas superfícies das lâminas de corte dos instrumentos Reciproc e Pro-R antes e após um e dois usos (p> 0,05). O Reciproc na condição sem uso apresentou maior Sa e Sq quando comparado ao Pro-R (p <0,05). Não foram observadas diferenças entre Reciproc e Pro-R após um e dois usos (p> 0,05). O Reciproc sem uso apresentou maior tempo de fratura do que os instrumentos Pro-R (p<0,05), e apenas o Pro-R apresentou diferenças entre instrumentos novos e usados (p<0,05). Os procedimentos de retratamento com Reciproc e Pro-R não alteraram a topografia da superfície dos instrumentos. Reciproc apresentou maior resistência à fadiga cíclica em comparação com o Pro-R.

20.
Braz Dent J ; 33(3): 38-46, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35766715

RESUMO

This study evaluated the Reciproc R25 and Pro-R 25 instruments in unused condition, after one and a second use in endodontic retreatment employing a noncontact 3D light interferometer profiler, scanning electron microscopy (SEM) and cyclic fatigue tests. Twenty single-root teeth were instrumented with Reciproc R25 and filled with gutta-percha and sealer. A 3D profiler with a 20x objective using the Mx™ software was used to evaluate the cutting blade surfaces of Reciproc R25 and Pro-R 25 (n=5 per group) in unused condition, after the first and second uses in retreatment procedures. After retreatment, SEM was used to evaluate the topographic features of the used instruments. Cyclic fatigue tests were performed to compare new to used instruments. One-way ANOVA followed by Tukey test was used to compare the tested instruments before and after the first and second uses. Student t-test was used to compare the different instruments and for cyclic fatigue evaluation. No significant differences were observed in the cutting blade surfaces of Reciproc and Pro-R before and after one and two uses (p>0.05). Reciproc without use showed higher Sa and Sq when compared to Pro-R without use (p<0.05). No differences were observed between Reciproc and Pro-R after one and two uses (p>0.05). New and unused Reciproc showed longer time to fracture than Pro-R instruments (p<0.05), and only Pro-R showed differences between new and used instruments (p<0.05). Retreatment procedures with Reciproc and Pro-R did not change the surface topography of instruments. Reciproc had greater resistance to cyclic fatigue compared with Pro-R.


Assuntos
Instrumentos Odontológicos , Preparo de Canal Radicular , Desenho de Equipamento , Guta-Percha , Humanos , Retratamento , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA