Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J. health sci. (Londrina) ; 23(3): 179-184, 20210920.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1292748

RESUMO

The choice of the best finishing/polishing methods for composite resin restorations is critical to the choice of excellence results related to longer clinical longevity. The objective of the study was to evaluate the influence of finishing and polishing systems on the surface roughness of a Nanoparticulate and Bulk-fill resin. For the research, 40 sample disks were prepared for each composite: single-increment (BF) (Bulk Fill 3M), both 2 mm thick and 10 mm in diameter (FZ) (Filtek Z350, 3M). The specimens were randomly divided into 4 groups with 10 samples each, according to the different materials to which they were subjected to the finishing and polishing protocols: control [C]- diamond tip (FG 4137F FAVA); [EN] polishing discs (Enhance, Dentsply); [SL] Abrasive discs (Sof-Lex Pop-on, 3M) and [PD] felt disc + Polishing paste (Diamond Excel, FGM). A surface roughness (Ra) was verified with a roughness meter in three different data volumes and calculated as arithmetic means. Data were statistically treated by one way ANOVA followed by test t and student t test. Regardless of the data tested, evidence of the systemic controlling against different systems for polishing control with control (p <0.05). PD presented statistically greater roughness to the EN and SL (p <0.001), these in turn obtained similar performance and presented the lowest values of roughness for both composites (p> 0.05). The different finishing / polishing methods influenced the surface roughness of both composites, observing for Sof-lex and Enhance lower Ra values. (AU)


A escolha dos adequados métodos de acabamento/polimento para restaurações de resina composta é fundamental para obtenção de resultados de excelência, relacionados a maior longevidade clínica. O objetivo desse estudo foi avaliar a influência dos sistemas de acabamento e polimento na rugosidade de superfície das resinas nanoparticuladas convencional e bulk-fill. Para a pesquisa foram confeccionados 40 discos de amostra para cada compósito: Convencional [FZ] (Filtek Z350, 3M) e de incremento único [BF] (Filtek Bulk Fill, 3M), ambas com 2 mm de espessura e 10 mm de diâmetro. Foram divididos aleatoriamente em 4 grupos com 10 amostras cada, de acordo com os diferentes protocolos que receberam, sendo: controle (C) ponta diamantada (FG 4137F, FAVA); (EN) discos de silicone (Enhance, Dentsply); (SL) discos abrasivos (Sof-Lex Pop-on, 3M); (PD) Feltro + Pasta diamantada (Diamond Excel, FGM). A rugosidade de superfície (Ra) foi verificada com um rugosímetro em três leituras de diferentes direções e calculadas as médias aritméticas. Os dados foram tratados estatisticamente pelos testes ANOVA 1 fator seguido pelo teste t e t de student (p<0,05). Independente da resina testada, evidenciou-se diminuição da rugosidade pelos diferentes sistemas de polimento frente ao grupo controle (p<0,05). PD apresentou rugosidade estatisticamente maior à EN e SL (p<0,001), estes últimos que por sua vez obtiveram desempenho semelhante e apresentaram os menores valores de rugosidade para ambos os compósitos (p>0,05). Os diferentes métodos de acabamento/polimento influenciaram na rugosidade de superfície dos dois compósitos testados, observando para Sof-lex e Enhance menores valores de Ra. (AU)

2.
J Adv Prosthodont ; 11(4): 215-222, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31497269

RESUMO

PURPOSE: To evaluate the polishing effect on roughness and color change of pressed and layering ceramics after immersion in coffee solution. MATERIALS AND METHODS: 88 ceramic discs (1.0 mm × 10.0 mm) were manufactured - 44 nano-fluorapatite layering ceramics (IPS e.max Ceram. Group C) and 44 pressed lithium disilicate ceramic discs (IPS e. max Press - Group P). Each group was divided into 4 subgroups according to surface treatments: (G) Glaze, (S) Shofu polishing system (Shofu Inc.), (E) Edenta AG polishing System, (KG) 30-µm diamond granulation tip. Surface roughness (Ra) and color change (ΔE) measurings after the surface treatments were performed, before and 12 days after the immersion in coffee solution. A samples' qualitative analysis was conducted with a scanning electron microscopy (SEM). Data were statistically-treated with one-way-ANOVA and Duncan's tests, apart from paired t-test and Pearson's correlation test (α=5%). RESULTS: The decrescent order, both for surface roughness (Ra) and ΔE for both ceramics were: KG > E > S > G (P<.05). With exception for PG and CG subgroups, which did not present statistical difference between them, all other pressed ceramics subgroups presented smaller Ra values and greater ΔE values than the layering ceramics subgroups (P<.05). CONCLUSION: Although mechanical polishing systems presented intermediate Ra values, their colors were considered clinically acceptable. There is a strong correlation between the surface roughness and the color change of tested ceramics.

3.
Full dent. sci ; 11(41): 128-134, 2019. tab
Artigo em Português | BBO - Odontologia | ID: biblio-1052063

RESUMO

Cimentação é uma etapa extremamente importante para o sucesso de reabilitações estéticas utilizando cerâmicas, tornando-se fundamental o entendimento dos materiais utilizados nesse processo, como os cimentos e agentes de união. Avaliou-se a resistência de união gerada por diferentes tratamentos de superfície em cerâmica feldspática com cimentos resinosos utilizando diferentes agentes de união. Foram confeccionados 24 discos de cerâmica feldspática (Super porcelain EX-3, Noritake) e divididos de acordo com o agente de união utilizado: Grupo SAU - sem aplicação de agentes; Grupo SIL - aplicado silano (RelyX cerâmic Primer, 3M ESPE); Grupo ADU - aplicado adesivo universal (Single Bond Universal, 3M ESPE) e Grupo SIL+ADU - aplicado silano e adesivo universal. Sobre cada amostra foram confeccionados 4 cilindros de cimentos resinosos: RelyX ARC (RXA) (3M ESPE) e RelyX Ultimate (RXU) (3M ESPE), totalizando 12 tubos de cada cimento por grupo. Então, foram submetidos ao teste de microcisalhamento em máquina de ensaios universais Série 23 EMIC (Instron Brasil) e verificado em microscópio o padrão de fratura gerado. A comparação entre grupos usando cimento RXA mostrou que, utilizando silano combinado ou não ao adesivo, proporcionou melhores resultados que os demais grupos (p=0,05). Utilizando o mesmo tratamento de superfície, não foi verificada diferença significante entre os cimentos, exceto para Grupo SAU (p=0,05). Concluiu-se que utilizar silano combinado ou não a adesivos universais melhora a adesão de alguns cimentos utilizados na cimentação de cerâmicas feldspáticas. Quando aplicado o mesmo agente, não há diferença entre os cimentos testados (AU).


Cementation is an extremely important step for the success of aesthetic restorations using ceramics, making it fundamental to understand the materials used in this process, such as cements and bonding agents. This study aimed to evaluate the bond strength generated by different surface treatments in feldspathic ceramic with resin cements using different bonding agents. Twenty-four feldspathic ceramic discs (Super porcelain EX-3, Noritake) were prepared and divided according to the bonding agent used: Group SAU - without application; Group SIL - applied silane (RelyX ceramics Primer, 3M ESPE); Group ADU - applied universal adhesive (Universal Bond Single, 3M ESPE); and Group SIL+ADU - silane and universal adhesive. For each sample, 4 cylinders of resin cements were made: RelyX ARC (RXA) (3M ESPE) and RelyX Ultimate (RXU) (3M ESPE), totaling 12 tubes of each cement per group. Then, they were submitted to the micro-shear test in the universal Series 23 EMIC assay (Instron Brasil) and microscopically verified the generated fracture pattern. The comparison between groups using RXA cement showed that using silane combined or not with the adhesive gave better results than the other groups (p=0,05). Using the same surface treatment, no significant difference was observed between the cements, except for Group SAU (p<0.05). It was concluded that using silane combined or not with universal adhesives improves the adhesion of some cements used in the cementation of feldspathic ceramics. When applied the same agent, there is no difference between the cements tested (AU).


Assuntos
Cerâmica , Cimentos de Resina , Cimentos Dentários , Resistência ao Cisalhamento , Brasil , Análise de Variância , Estatísticas não Paramétricas , Materiais Dentários
4.
Full dent. sci ; 10(38): 124-129, 2019. tab, graf
Artigo em Português | BBO - Odontologia | ID: biblio-998503

RESUMO

Próteses dentárias removíveis constituem um tratamento reabilitador muito indicado para pacientes mutilados, devolvendo estética e função. Contudo, quando não confeccionada e/ou utilizada corretamente, pode ocasionar transtornos ao seu usuário. Este artigo tem como objetivo relatar a prevalência de lesões orais relacionadas ao uso de próteses dentárias removíveis em pacientes atendidos na clínica Odontológica da Escola de Ensino Superior São Francisco de Assis (ESFA), Santa Teresa/ES. Um estudo transversal quantitativo foi realizado através da análise de 141 prontuários de indivíduos atendidos no período de março de 2012 a julho de 2017, sendo que, desses, 61 foram exclusos por motivos técnicos. Dos 80 inclusos, em 15% (n=12) houve algum relato de injúria e, destes, 16,66% (n=2) apresentavam candidose, 25% (n=3) hiperplasia fibrosa inflamatória, 8,33% (n=1) hiperplasia papilar do palato e 50% (n=6) na categoria "outros", caracterizando as lesões encontradas. O gênero feminino foi o mais afetado com 66,66% (n=8) dos casos, enquanto no masculino, em 33,34% (n=4), houve algum registro. Comprovou-se, então, que o uso de próteses dentárias removíveis pode ser causadora de lesões orais, bem como o gênero está estatisticamente relacionado ao aparecimento de determinadas injúrias (AU).


Removable dental prostheses are a very suitable rehabilitation treatment for mutilated patients, returning aesthetics and function. However, when not made and/or used correctly, it can cause disruption to its user. The aim of this article is to report the prevalence of oral lesions related to the use of removable dental prosthesis in patients of the Superior School São Francisco de Assis (ESFA) Dentistry College, Santa Teresa/ES. A quantitative cross-sectional study was carried out through the analysis of 141 medical records of individuals attended in the period from March 2012 to July 2017, of which 61 were excluded for technical reasons. Of the 80 cases included, 15.6% (n = 12) presented some injuries, of which 16.66% (n = 2) presented candidiasis, 25% (n = 3) inflammatory fibrous hyperplasia, 8.33% (n=1) papillary hyperplasia of the palate, and 50% (n = 6) in the category "other", characterizing the lesions found. The female gender was the most affected with 66.66% (n = 8) of the cases, while in the male, in 33.34% (n = 4), there were some records. It was then proved that the use of removable dental prostheses can be the cause of oral lesions, as well as that gender is statistically related to the appearance of certain injuries (AU).


Assuntos
Humanos , Masculino , Feminino , Tabagismo , Prevalência , Prótese Dentária , Boca/lesões , Brasil , Distribuição de Qui-Quadrado , Estudos Transversais/métodos
5.
Full dent. sci ; 10(39): 155-159, 2019. tab
Artigo em Português | BBO - Odontologia | ID: biblio-1046284

RESUMO

A confecção de restaurações provisórias constitui etapa importante para o sucesso das reabilitações com próteses fixas. Para melhores resultados, é fundamental que estas restaurações tenham adequada lisura superficial, a fim de evitar o acúmulo de biofilme, bem como suas consequências. Objetivou-se avaliar a influência dos sistemas de polimento na rugosidade de superfície das resinas acrílicas autopolimerizáveis. Foram confeccionados 50 discos (10×2 mm) de 3 diferentes resinas acrílicas autopolimerizáveis comumente utilizadas em consultórios odontológicos (150 discos no total). Estes foram aleatoriamente divididos em 5 grupos (n=10) de acordo com o tratamento de superfície que receberam: (C) controle ­ broca de tungstênio de corte cruzado médio, (E) sistema de polimento Exa Technique (Edenta AG), (EP) sistema de polimento Exa Technique + pasta diamantada, (V) Kit de polimento Viking (KG Sorensen) e (VP) Kit de polimento Viking + pasta diamantada. A rugosidade de superfície (Ra) foi verificada através de um rugosímetro por meio de quatro leituras em diferentes direções dos discos e, em seguida, calculadas as médias aritméticas. Independente da resina acrílica, os maiores valores de Ra foram observados para os discos tratados apenas com a broca de tungstênio e não foram observadas diferenças estatísticas significantes entre os sistemas de acabamento/polimento utilizados (p<0,05). Independente dos sistemas, não houve diferença estatística significante de Ra entre as resinas acrílicas testadas neste estudo (p<0,05). Os sistemas de acabamento/polimento influenciaram na rugosidade de superfície das resinas acrílicas autopolimerizáveis testadas. A adição da pasta diamantada à estratégia de polimento não proporcionou melhoria de Ra (AU).


The preparation of temporary restorations constitutes an important step for the success of rehabilitations with fixed prostheses. For best results, it is essential that these restorations have adequate superficial smoothness in order to avoid biofilm accumulation, as well as its consequences. This study aimed to assess the influence of polishing systems in self-curing acrylic resin surface roughness. Fifty discs (10×2 mm) of 3 different self-curing acrylic resins commonly used in dentistry were made (150 discs in total). These were randomly divided into 5 groups (n=10) according to the surface treatment they received: (C) control ­ medium cross-cut tungsten drill; (E) Exa Technique polishing system (Edenta AG); (EP) Exa Technique polishing system + diamond paste; (V) Viking polishing kit (KG Sorensen); and (VP) Viking polishing kit + diamond paste. The surface roughness (Ra) was verified through a rugosimeter by means of four readings in different directions of the disks and then the arithmetic averages were calculated. Regardless the acrylic resin type, the highest values of Ra were observed for the disks treated only with tungsten drill, and no statistically significant differences were observed between the finishing/polishing systems used (p <0.05). Regardless of the systems, there was no statistically significant difference of Ra between the acrylic resins tested in this study (p <0.05). Finishing/polishing systems influenced the surface roughness of the self-curing acrylic resins tested. Addition of the diamond paste to the polishing strategy did not provide Ra improvement (AU).


Assuntos
Propriedades de Superfície , Resinas Acrílicas , Polimento Dentário/métodos , Restauração Dentária Temporária , Brasil , Estatísticas não Paramétricas , Reabilitação Bucal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA