Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 20(5)2020 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-32182814

RESUMO

In this work, we propose an adaptive face tracking scheme that compensates for possible face tracking errors during its operation. The proposed scheme is equipped with a tracking divergence estimate, which allows to detect early and minimize the face tracking errors, so the tracked face is not missed indefinitely. When the estimated face tracking error increases, a resyncing mechanism based on Constrained Local Models (CLM) is activated to reduce the tracking errors by re-estimating the tracked facial features' locations (e.g., facial landmarks). To improve the Constrained Local Model (CLM) feature search mechanism, a Weighted-CLM (W-CLM) is proposed and used in resyncing. The performance of the proposed face tracking method is evaluated in the challenging context of driver monitoring using yawning detection and talking video datasets. Furthermore, an improvement in a yawning detection scheme is proposed. Experiments suggest that our proposed face tracking scheme can obtain a better performance than comparable state-of-the-art face tracking methods and can be successfully applied in yawning detection.


Assuntos
Face/diagnóstico por imagem , Face/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Bocejo/fisiologia , Adolescente , Adulto , Algoritmos , Feminino , Humanos , Masculino , Gravação em Vídeo , Adulto Jovem
2.
PLoS One ; 10(1): e0115218, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25602498

RESUMO

This paper presents a new automatic framework for extracting and characterizing the dynamic shape of the 3D wetting front and its propagation, based in a sequence of tomographic images acquired as water (moisture) infiltrates in unsaturated soils. To the best of the authors' knowledge, the shape of the 3D wetting front and its propagation and progress over time has not been previously produced as a whole by methods in existing literature. The proposed automatic framework is composed two important and integrated modules: i) extraction of the 3D wetting front, and ii) characterization and description of the 3D wetting front to obtain important information about infiltration process. The 3D wetting front surface is segmented from 3D CT imagery provided as input via a 3D stochastic region merging strategy using quadric-regressed bilateral space-scale representations. Based on the 3D segmentation results, the normal directions at local curvature maxima of the wetting front surface are computed for 3D images of soil moisture, and its propagation is analyzed at the local directions in sites of maximal water adsorption, and described using histograms of curvature changes over time in response to sample saturation. These curvature change descriptors provide indirect measurements of moisture infiltration in soils, and soil saturation. Results using a field tomograph equipment specific for soil studies are encouraging, and suggest that the proposed automatic framework can be applied to estimate the infiltration of water in soils in 3D and in time.


Assuntos
Modelos Teóricos , Solo , Tomografia , Molhabilidade , Algoritmos
3.
Med Image Anal ; 16(1): 160-76, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21920798

RESUMO

Specialists often need to browse through libraries containing many diagnostic hysteroscopy videos searching for similar cases, or even to review the video of one particular case. Video searching and browsing can be used in many situations, like in case-based diagnosis when videos of previously diagnosed cases are compared, in case referrals, in reviewing the patient records, as well as for supporting medical research (e.g. in human reproduction). However, in terms of visual content, diagnostic hysteroscopy videos contain lots of information, but only a reduced number of frames are actually useful for diagnosis/prognosis purposes. In order to facilitate the browsing task, we propose in this paper a technique for estimating the clinical relevance of video segments in diagnostic hysteroscopies. Basically, the proposed technique associates clinical relevance with the attention attracted by a diagnostic hysteroscopy video segment during the video acquisition (i.e. during the diagnostic hysteroscopy conducted by a specialist). We show that the resulting video summary allows specialists to browse the video contents nonlinearly, while avoiding spending time on spurious visual information. In this work, we review state-of-art methods for summarizing general videos and how they apply to diagnostic hysteroscopy videos (considering their specific characteristics), and conclude that our proposed method contributes to the field with a summarization and representation method specific for video hysteroscopies. The experimental results indicate that our method tends to produce compact video summaries without discarding clinically relevant information.


Assuntos
Atenção , Mineração de Dados/métodos , Histeroscopia/métodos , Interpretação de Imagem Assistida por Computador/métodos , Sistemas de Informação em Radiologia , Interface Usuário-Computador , Gravação em Vídeo/métodos , Sistemas de Gerenciamento de Base de Dados , Feminino , Humanos
4.
Comput Med Imaging Graph ; 35(6): 481-91, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21489751

RESUMO

This paper describes a new method for classifying pigmented skin lesions as benign or malignant. The skin lesion images are acquired with standard cameras, and our method can be used in telemedicine by non-specialists. Each acquired image undergoes a sequence of processing steps, namely: (1) preprocessing, where shading effects are attenuated; (2) segmentation, where a 3-channel image representation is generated and later used to distinguish between lesion and healthy skin areas; (3) feature extraction, where a quantitative representation for the lesion area is generated; and (4) lesion classification, producing an estimate if the lesion is benign or malignant (melanoma). Our method was tested on two publicly available datasets of pigmented skin lesion images. The preliminary experimental results are promising, and suggest that our method can achieve a classification accuracy of 96.71%, which is significantly better than the accuracy of comparable methods available in the literature.


Assuntos
Programas de Rastreamento , Fotografação/instrumentação , Neoplasias Cutâneas/diagnóstico , Pigmentação da Pele , Algoritmos , Diagnóstico por Computador , Humanos , Neoplasias Cutâneas/classificação
5.
Artigo em Inglês | MEDLINE | ID: mdl-22255705

RESUMO

Segmentation is an important step in computer-aided diagnostic systems for pigmented skin lesions, since that a good definition of the lesion area and its boundary at the image is very important to distinguish benign from malignant cases. In this paper a new skin lesion segmentation method is proposed. This method uses Independent Component Analysis to locate skin lesions in the image, and this location information is further refined by a Level-set segmentation method. Our method was evaluated in 141 images and achieved an average segmentation error of 16.55%, lower than the results for comparable state-of-the-art methods proposed in literature.


Assuntos
Algoritmos , Dermoscopia/métodos , Interpretação de Imagem Assistida por Computador/métodos , Melanoma/patologia , Reconhecimento Automatizado de Padrão/métodos , Transtornos da Pigmentação/patologia , Neoplasias Cutâneas/patologia , Humanos , Aumento da Imagem/métodos , Análise de Componente Principal , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Comput Methods Programs Biomed ; 104(3): 397-409, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20843577

RESUMO

In this work, we present a new fovea center detection method for color eye fundus images. This method is based on known anatomical constraints on the relative locations of retina structures, and mathematical morphology. The detection of this anatomical feature is a prerequisite for the computer aided diagnosis of several retinal diseases, such as Diabetic Macular Edema. The proposed method is adaptive to local illumination changes, and it is robust to local disturbances introduced by pathologies in digital color eye fundus images (e.g. exudates). Our experimental results using the DRIVE image database indicate that our method is able to detect the fovea center in 37 out of 37 images (i.e. with a success rate of 100%). Using the DIARETDB1 database, our method was able to detect the fovea center in 92.13% of all tested cases (i.e. in 82 out of 89 images). These results indicate that our approach potentially can achieve a better performance than comparable methods proposed in the literature.


Assuntos
Fóvea Central , Retina/anatomia & histologia , Bases de Dados Factuais , Diagnóstico por Computador , Humanos , Doenças Retinianas/diagnóstico
7.
Comput Biol Med ; 40(2): 124-37, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20045104

RESUMO

The identification of some important retinal anatomical regions is a prerequisite for the computer aided diagnosis of several retinal diseases. In this paper, we propose a new adaptive method for the automatic segmentation of the optic disk in digital color fundus images, using mathematical morphology. The proposed method has been designed to be robust under varying illumination and image acquisition conditions, common in eye fundus imaging. Our experimental results based on two publicly available eye fundus image databases are encouraging, and indicate that our approach potentially can achieve a better performance than other known methods proposed in the literature. Using the DRIVE database (which consists of 40 retinal images), our method achieves a success rate of 100% in the correct location of the optic disk, with 41.47% of mean overlap. In the DIARETDB1 database (which consists of 89 retinal images), the optic disk is correctly located in 97.75% of the images, with a mean overlap of 43.65%.


Assuntos
Fundo de Olho , Interpretação de Imagem Assistida por Computador/métodos , Disco Óptico/anatomia & histologia , Algoritmos , Bases de Dados Factuais , Retinopatia Diabética/patologia , Humanos , Microvasos/anatomia & histologia , Disco Óptico/irrigação sanguínea , Disco Óptico/patologia , Doenças Retinianas/diagnóstico , Doenças Retinianas/patologia , Design de Software
8.
J Digit Imaging ; 23(6): 755-68, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19768508

RESUMO

This paper addresses the need to quantify tumor growth and detect changes as this information is relevant to manage the patient treatment and to aid biotechnological efforts to cure cancer (Silva et al. 2008). An interactive tumor segmentation technique is used to recover the shape and size of tumors without imposing shape constraints. This segmentation algorithm provides good convergence, is robust to the initialization conditions, and requires simple and intuitive user interactions. A parametric approach to model tumor growth analytically is proposed in this paper. The preliminary experimental results are encouraging. The segmentation method is shown to be robust and simple to use, even in situations where the tumor boundary definition is challenging. Also, the experiments indicate that the proposed model potentially can be used to extrapolate the available data and help predict the tumor size (assuming unconstrained growth). Additionally, the proposed method potentially can provide a quantitative reference to compare the tumor shrinkage rate in cancer treatments.


Assuntos
Modelos Biológicos , Neoplasias/patologia , Carga Tumoral , Seguimentos , Humanos
9.
Comput Med Imaging Graph ; 34(3): 228-35, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19954928

RESUMO

The detection of exudates is a prerequisite for detecting and grading severe retinal lesions, like the diabetic macular edema. In this work, we present a new method based on mathematical morphology for detecting exudates in color eye fundus images. A preliminary evaluation of the proposed method performance on a known public database, namely DIARETDB1, indicates that it can achieve an average sensitivity of 70.48%, and an average specificity of 98.84%. Comparing to other recent automatic methods available in the literature, our proposed approach potentially can obtain better exudate detection results in terms of sensitivity and specificity.


Assuntos
Cor , Diagnóstico por Imagem/métodos , Exsudatos e Transudatos/diagnóstico por imagem , Fundo de Olho , Algoritmos , Complicações do Diabetes , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Edema Macular/diagnóstico , Radiografia
10.
IEEE Trans Image Process ; 19(4): 1036-49, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20028629

RESUMO

This work describes an approach for object-oriented video segmentation based on motion coherence. Using a tracking process based on adaptively sampled points (namely, particles), 2-D motion patterns are identified with an ensemble clustering approach. Particles are clustered to obtain a pixel-wise segmentation in space and time domains. The segmentation result is mapped to an image spatio-temporal feature space. Thus, the different constituent parts of the scene that move coherently along the video sequence are mapped to volumes in this spatio-temporal space. These volumes make the redundancy in the temporal sense more explicit, leading to potential gains in video coding applications. The proposed solution is robust and more generic than similar approaches for 2-D video segmentation found in the literature. In order to illustrate the potential advantages of using the proposed motion segmentation approach in video coding applications, the PSNR of the temporal predictions and the entropies of prediction errors obtained in our experiments are presented, and compared with other methods. Our experiments with real and synthetic sequences suggest that our method also could be used in other image processing and computer vision tasks, besides video coding, such as video information retrieval and video understanding.

11.
Artigo em Inglês | MEDLINE | ID: mdl-19380906

RESUMO

This paper presents a novel method for the detection of the fovea center in color fundus images. The method was evaluated using a set of 89 images from the DIARETDB1 project, which contains images presenting normal and pathological situations. Using the Mean Absolute Distance (MAD) as a metric, we report 7.37+/-8.89 (mean +/- standard deviation) detection performance for the fovea center which represents an improvement in comparison to other state-of-the-art methods in the literature.


Assuntos
Algoritmos , Cor , Fóvea Central , Processamento de Imagem Assistida por Computador , Fundo de Olho , Humanos , Processamento de Imagem Assistida por Computador/normas , Degeneração Macular/patologia
12.
Comput Med Imaging Graph ; 32(5): 379-87, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18468861

RESUMO

This paper presents a two-stage motion compensation coding scheme for image sequences in hemodynamics. The first stage of the proposed method implements motion compensation, and the second stage corrects local pixel intensity distortions with a context adaptive linear predictor. The proposed method is robust to the local intensity distortions and the noise that often degrades these image sequences, providing lossless and near-lossless quality. Our experiments with lossless compression of 12bits/pixel studies indicate that, potentially, our approach can perform 3.8%, 2% and 1.6% better than JPEG-2000, JPEG-LS and the method proposed by Scharcanski [1], respectively. The performance tends to improve for near-lossless compression. Therefore, this work presents experimental evidence that for coding image sequences in hemodynamics, an adequate motion compensation scheme can be more efficient than the still-image coding methods often used nowadays.


Assuntos
Algoritmos , Angiografia/métodos , Artefatos , Compressão de Dados/métodos , Intensificação de Imagem Radiográfica/métodos , Humanos , Movimento (Física) , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Artigo em Inglês | MEDLINE | ID: mdl-18003298

RESUMO

This paper presents a context adaptive coding method for image sequences in hemodynamics. The proposed method implements motion compensation through of a two-stage context adaptive linear predictor. It is robust to the local intensity changes and the noise that often degrades these image sequences, and provides lossless and near-lossless quality. Our preliminary experiments with lossless compression of 12 bits/pixel studies indicate that, potentially, our approach can perform 3.8%, 2% and 1.6% better than JPEG-2000, JPEG-LS and the method proposed in [1], respectively. The performance tends to improve for near-lossless compression.


Assuntos
Algoritmos , Angiografia/métodos , Compressão de Dados/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Sinais Assistido por Computador , Gravação em Vídeo/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Artigo em Inglês | MEDLINE | ID: mdl-18002736

RESUMO

Renal scintigraphy is a well-established functional technique for the visual evaluation of the renal cortical mass. It allows the visualization of the radiopharmaceutical tracer distribution, the size, shape, symmetry, and position of the kidneys. However, the (visual) analysis of these images tend to be subjective, causing significant variability in the interpretation of findings. This paper proposes objective measures that reflect common findings observed in those images, and potentially can minimize the inter-observer variability. We also propose a segmentation method specific for renal scintigraphic images. Our preliminary experiments indicate that our proposed features agree in at least 90% of the cases with the specialists visual evaluation.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Nefropatias/diagnóstico por imagem , Rim/diagnóstico por imagem , Cintilografia/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Comput Med Imaging Graph ; 30(4): 243-54, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16839742

RESUMO

Dense regions in digital mammographic images are usually noisy and have low contrast, and their visual screening is difficult. This paper describes a new method for mammographic image noise suppression and enhancement, which can be effective particularly for screening image dense regions. Initially, the image is preprocessed to improve its local contrast and the discrimination of subtle details. Next, image noise suppression and edge enhancement are performed based on the wavelet transform. At each resolution, coefficients associated with noise are modelled by Gaussian random variables; coefficients associated with edges are modelled by Generalized Laplacian random variables, and a shrinkage function is assembled based on posterior probabilities. The shrinkage functions at consecutive scales are combined, and then applied to the wavelets coefficients. Given a resolution of analysis, the image denoising process is adaptive (i.e. does not require further parameter adjustments), and the selection of a gain factor provides the desired detail enhancement. The enhancement function was designed to avoid introducing artifacts in the enhancement process, which is essential in mammographic image analysis. Our preliminary results indicate that our method allows to enhance local contrast, and detect microcalcifications and other suspicious structures in situations where their detection would be difficult otherwise. Compared to other approaches, our method requires less parameter adjustments by the user.


Assuntos
Mamografia/normas , Intensificação de Imagem Radiográfica , Mamografia/métodos
16.
Comput Biol Med ; 36(4): 327-38, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16488771

RESUMO

The web has become such an extensive health information repository in the world that it is increasingly difficult to search for relevant medical information. Most medical information available on the web is not peer reviewed, and is retrieved imprecisely by current web search mechanisms (i.e. based on keywords). This paper presents the MedISeek metadata model that allows one to describe medical visual information (i.e. medical images) of different modalities, including their properties, components, relationships and authorship. The model uses the web architecture and supports the international classification of diseases and related health problems (i.e. ICD-10). An RDF schema (Resource Description Framework (RDF), http://www.w3.org/RDF/.) derived from this metadata model is integrated to each medical image, and specifies the semantics of each property in the image. Thus, relevant information can be extracted directly from the images, and data integrity is better preserved in the web. A prototype, presented here, has been built to validate the metadata model, and the mechanism for medical visual information exchange on the web. Our preliminary experimental results indicate that authorized users of our system have been able to describe, store and retrieve medical images and their associated diagnostic information.


Assuntos
Armazenamento e Recuperação da Informação , Internet , Sistemas Computacionais , Humanos , Processamento de Imagem Assistida por Computador , Software , Interface Usuário-Computador
17.
IEEE Trans Image Process ; 11(9): 1092-101, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-18249730

RESUMO

This paper proposes a new method for image denoising with edge preservation, based on image multiresolution decomposition by a redundant wavelet transform. In our approach, edges are implicitly located and preserved in the wavelet domain, whilst image noise is filtered out. At each resolution level, the image edges are estimated by gradient magnitudes (obtained from the wavelet coefficients), which are modeled probabilistically, and a shrinkage function is assembled based on the model obtained. Joint use of space and scale consistency is applied for better preservation of edges. The shrinkage functions are combined to preserve edges that appear simultaneously at several resolutions, and geometric constraints are applied to preserve edges that are not isolated. The proposed technique produces a filtered version of the original image, where homogeneous regions appear separated by well-defined edges. Possible applications include image presegmentation, and image denoising.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA