Radiol Bras ; 57: e20230083, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38993961

RESUMO

Objective: To test the performance of ChatGPT on radiology questions formulated by the Colégio Brasileiro de Radiologia (CBR, Brazilian College of Radiology), evaluating its failures and successes. Materials and Methods: 165 questions from the CBR annual resident assessment (2018, 2019, and 2022) were presented to ChatGPT. For statistical analysis, the questions were divided by the type of cognitive skills assessed (lower or higher order), by topic (physics or clinical), by subspecialty, by style (description of a clinical finding or sign, clinical management of a case, application of a concept, calculation/classification of findings, correlations between diseases, or anatomy), and by target academic year (all, second/third year, or third year only). Results: ChatGPT answered 88 (53.3%) of the questions correctly. It performed significantly better on the questions assessing lower-order cognitive skills than on those assessing higher-order cognitive skills, providing the correct answer on 38 (64.4%) of 59 questions and on only 50 (47.2%) of 106 questions, respectively (p = 0.01). The accuracy rate was significantly higher for physics questions than for clinical questions, correct answers being provided for 18 (90.0%) of 20 physics questions and for 70 (48.3%) of 145 clinical questions (p = 0.02). There was no significant difference in performance among the subspecialties or among the academic years (p > 0.05). Conclusion: Even without dedicated training in this field, ChatGPT demonstrates reasonable performance, albeit still insufficient for approval, on radiology questions formulated by the CBR.


Objetivo: Testar o desempenho do ChatGPT em questões de radiologia formuladas pelo Colégio Brasileiro de Radiologia (CBR), avaliando seus erros e acertos. Materiais e Métodos: 165 questões da avaliação anual dos residentes do CBR (2018, 2019 e 2022) foram apresentadas ao ChatGPT. Elas foram divididas, para análise estatística, em questões que avaliavam habilidades cognitivas de ordem superior ou inferior e de acordo com a subespecialidade, o tipo da questão (descrição de um achado clínico ou sinal, manejo clínico de um doente, aplicação de um conceito, cálculo ou classificação dos achados descritos, associação entre doenças ou anatomia) e o ano da residência (R1, R2 ou R3). Resultados: O ChatGPT acertou 53,3% das questões (88/165). Houve diferença estatística entre o desempenho em questões de ordem cognitiva inferior (64,4%; 38/59) e superior (47,2%; 50/106) (p = 0,01). Houve maior índice de acertos em física (90,0%; 18/20) do que em questões clínicas (48,3%; 70/145) (p = 0,02). Não houve diferença significativa de desempenho entre subespecialidades ou ano de residência (p > 0,05). Conclusão: Mesmo sem treinamento dedicado a essa área, o ChatGPT apresenta desempenho razoável, mas ainda insuficiente para aprovação, em questões de radiologia formuladas pelo CBR.

2.
Radiol. bras ; Radiol. bras;57: e20230083, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1558821

RESUMO

Abstract Objective: To test the performance of ChatGPT on radiology questions formulated by the Colégio Brasileiro de Radiologia (CBR, Brazilian College of Radiology), evaluating its failures and successes. Materials and Methods: 165 questions from the CBR annual resident assessment (2018, 2019, and 2022) were presented to ChatGPT. For statistical analysis, the questions were divided by the type of cognitive skills assessed (lower or higher order), by topic (physics or clinical), by subspecialty, by style (description of a clinical finding or sign, clinical management of a case, application of a concept, calculation/classification of findings, correlations between diseases, or anatomy), and by target academic year (all, second/third year, or third year only). Results: ChatGPT answered 88 (53.3%) of the questions correctly. It performed significantly better on the questions assessing lower-order cognitive skills than on those assessing higher-order cognitive skills, providing the correct answer on 38 (64.4%) of 59 questions and on only 50 (47.2%) of 106 questions, respectively (p = 0.01). The accuracy rate was significantly higher for physics questions than for clinical questions, correct answers being provided for 18 (90.0%) of 20 physics questions and for 70 (48.3%) of 145 clinical questions (p = 0.02). There was no significant difference in performance among the subspecialties or among the academic years (p > 0.05). Conclusion: Even without dedicated training in this field, ChatGPT demonstrates reasonable performance, albeit still insufficient for approval, on radiology questions formulated by the CBR.


Resumo Objetivo: Testar o desempenho do ChatGPT em questões de radiologia formuladas pelo Colégio Brasileiro de Radiologia (CBR), avaliando seus erros e acertos. Materiais e Métodos: 165 questões da avaliação anual dos residentes do CBR (2018, 2019 e 2022) foram apresentadas ao ChatGPT. Elas foram divididas, para análise estatística, em questões que avaliavam habilidades cognitivas de ordem superior ou inferior e de acordo com a subespecialidade, o tipo da questão (descrição de um achado clínico ou sinal, manejo clínico de um doente, aplicação de um conceito, cálculo ou classificação dos achados descritos, associação entre doenças ou anatomia) e o ano da residência (R1, R2 ou R3). Resultados: O ChatGPT acertou 53,3% das questões (88/165). Houve diferença estatística entre o desempenho em questões de ordem cognitiva inferior (64,4%; 38/59) e superior (47,2%; 50/106) (p = 0,01). Houve maior índice de acertos em física (90,0%; 18/20) do que em questões clínicas (48,3%; 70/145) (p = 0,02). Não houve diferença significativa de desempenho entre subespecialidades ou ano de residência (p > 0,05). Conclusão: Mesmo sem treinamento dedicado a essa área, o ChatGPT apresenta desempenho razoável, mas ainda insuficiente para aprovação, em questões de radiologia formuladas pelo CBR.

3.
Sci Data ; 10(1): 518, 2023 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-37542053

RESUMO

Pulmonary embolism has a high incidence and mortality, especially if undiagnosed. The examination of choice for diagnosing the disease is computed tomography pulmonary angiography. As many factors can lead to misinterpretations and diagnostic errors, different groups are utilizing deep learning methods to help improve this process. The diagnostic accuracy of these methods tends to increase by augmenting the training dataset. Deep learning methods can potentially benefit from the use of images acquired with devices from different vendors. To the best of our knowledge, we have developed the first public dataset annotated at the pixel and image levels and the first pixel-level annotated dataset to contain examinations performed with equipment from Toshiba and GE. This dataset includes 40 examinations, half performed with each piece of equipment, representing samples from two medical services. We also included measurements related to the cardiac and circulatory consequences of pulmonary embolism. We encourage the use of this dataset to develop, evaluate and compare the performance of new AI algorithms designed to diagnose PE.


Assuntos
Angiografia por Tomografia Computadorizada , Embolia Pulmonar , Humanos , Doença Aguda , Algoritmos , Angiografia/métodos , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
4.
Med Mycol Case Rep ; 36: 31-34, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35585870

RESUMO

Sporotrichosis is a global occurring implantation (subcutaneous) mycosis, caused by Sporothrix species, usually affecting the skin and the lymphatic vessels, from where it can disseminate. Nowadays, the vast majority of sporotrichosis infections in Brazil are caused by zoonotic transmission of S. brasiliensis which is the main etiologic agent. We report a cutaneous disseminated case of this disease, observed in an immunocompetent farmer living in southern Brazil, the Sporothrix schenckii-infection was successfully treated with itraconazole.

5.
Clin Imaging ; 86: 7-12, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35306311

RESUMO

INTRODUCTION: COVID-19 Reporting and Data System (CO-RADS) is a tool for standardizing the reports of patients with suspected or confirmed Sars-CoV-2 infection. We performed a study of the performance of the CO-RADS in a triage scenario of patients in Brazil. METHODS: Data from 426 Computed Tomography (CT) scans from March 2020 through December 2020 were assessed in an ambidirectional, both retrospective and prospective, for the assessment in one of the six categories of the CO-RADS. We assessed sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), negative likelihood ratio (NLR) Youden's index, Positive and Negative Clinical Utility Index (UC + and UC- respectively) and diagnostic odds ratio (DOR). We also plotted Receiver Operating Characteristics (ROC) curve with Area Under the Curve (AUC) for CO-RADS of >4 (4 + 5). RESULTS: For CO-RADS classification > 4 (4 + 5) considered positive, the AUC obtained was of 0.89 (95% CI of 0.02), sensitivity of 78% (95% CI of 0.3), specificity of 91% (95% CI of 0.3), PPV of 0.92 (95% CI of 0.02), NPV of 0.41 (95% CI of 0.03), PLR of 0.85 (95% CI of 0.2), and NLR of 0.23 (95% CI of 0.02). CONCLUSION: CO-RADS demonstrated overall good diagnostic performance in stratifying patients with suspected Sars-CoV-2 infection, even those without confirmed laboratorial diagnosis, therefore being useful in a triage scenario with lack of resources.


Assuntos
COVID-19 , Sistemas de Dados , Humanos , Estudos Prospectivos , Estudos Retrospectivos , SARS-CoV-2 , Sensibilidade e Especificidade
7.
Childs Nerv Syst ; 38(6): 1189-1193, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34586492

RESUMO

Delleman-Oorthuys or oculocerebrocutaneous syndrome (OCCS) is an extremely rare condition which relies on three pillars of manifestations: ophthalmological, neurological, and dermatological. It was first described by Delleman and Oorthuys in 1981, and since then, very few other cases have been reported. We report the case of a 13-month-old boy, referred to an ophthalmological tertiary service for investigation of a microglobe with a cystic retrobulbar mass on translucency test. MRI revealed a left microphthalmia, with extensive retrobulbar cystic lesions occupying the remaining orbit and protruding anteriorly the microglobe. Cerebral findings included polymicrogyria, subependymal nodular heterotopia at the level of the left occipital horn of the lateral ventricle, and an importantly enlarged mesencephalic tectum observed in association with an absent cerebellar vermis. The ensemble of malformations met the criteria for definite OCCS. Being a tremendously rare syndrome, OCCS will always represent a diagnostic challenge. However, its emblematic cutaneous manifestations might be an important part of the road map leading to its correct interpretation. Thus, when absent, diagnosis can be harder than usual, and, on these cases, neurologists, ophthalmologists, and radiologists play a crucial role.


Assuntos
Anormalidades Múltiplas , Cistos do Sistema Nervoso Central , Anormalidades do Olho , Anormalidades da Pele , Cistos do Sistema Nervoso Central/patologia , Anormalidades do Olho/complicações , Anormalidades do Olho/diagnóstico por imagem , Dedos/anormalidades , Humanos , Lactente , Masculino , Anormalidades da Pele/complicações , Anormalidades da Pele/diagnóstico por imagem
8.
Breast J ; 27(8): 675-677, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33982346

RESUMO

Cutaneous myiasis is an endemic infestation in Latin America and Africa. Many unusual sites of larval infection can cause diagnostic confusion, especially if the patient is not from an endemic area. In the breast, the furuncular aspect suggests some differential diagnosis. We report a case of an 84-year-old patient with an ulcerated lesion on the right breast, who was referred to the reference service to exclude malignancy. Considering the clinical aspects and after further evaluation with imaging methods, she was diagnosed with myiasis. This study reinforces the importance of differential diagnosis of myiasis in patients that come from endemic areas.


Assuntos
Neoplasias da Mama , Dípteros , Miíase , Idoso de 80 Anos ou mais , Animais , Diagnóstico Diferencial , Feminino , Humanos , Larva , Miíase/diagnóstico
9.
Radiol Res Pract ; 2021: 6667779, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33552601

RESUMO

BACKGROUND: The effects of dose reduction in lung nodule detection need better understanding. PURPOSE: To compare the detection rate of simulated lung nodules in a chest phantom using different computed tomography protocols, low dose (LD), ultralow dose (ULD), and conventional (CCT), and to quantify their respective amount of radiation. MATERIALS AND METHODS: A chest phantom containing 93 simulated lung nodules was scanned using five different protocols: ULD (80 kVp/30 mA), LD A (120 kVp/20 mA), LD B (100 kVp/30 mA), LD C (120 kVp/30 mA), and CCT (120 kVp/automatic mA). Four chest radiologists analyzed a selected image from each protocol and registered in diagrams the nodules they detected. Kruskal-Wallis and McNemar's tests were performed to determine the difference in nodule detection. Equivalent doses were estimated by placing thermoluminescent dosimeters on the surface and inside the phantom. RESULTS: There was no significant difference in lung nodules' detection when comparing ULD and LD protocols (p=0.208 to p=1.000), but there was a significant difference when comparing each one of those against CCT (p < 0.001). The detection rate of nodules with CT attenuation values lower than -600 HU was also different when comparing all protocols against CCT (p < 0.001 to p=0.007). There was at least moderate agreement between observers in all protocols (κ-value >0.41). Equivalent dose values ranged from 0.5 to 9 mSv. CONCLUSION: There is no significant difference in simulated lung nodules' detection when comparing ULD and LD protocols, but both differ from CCT, especially when considering lower-attenuating nodules.

10.
Acta Otolaryngol ; 141(3): 293-298, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33346687

RESUMO

BACKGROUND: Olfactory dysfunction is frequent in COVID-19 and it might occur along with pulmonary involvement. These manifestations do not seem to share pathophysiological mechanisms, but clinical data on the subject is lacking. Aims/Objectives: This study aims to correlate the olfactory function (OF) and the radiological pulmonary involvement among in-hospital patients with COVID-19. MATERIALS AND METHODS: Patients hospitalized with severe COVID-19 were consecutively recruited. They had their objective OF evaluated by the Alcohol Sniff Test and underwent a chest computed tomography (cCT). Qualitative and quantitative analyses of the cCT scans were performed by a blinded radiologist. The quantitative assessment included both the grade of involved parenchyma and the CT severity score (CT-SS). Data obtained were then compared. RESULTS: 57 patients were included. There was no correlation between the OF and the grade of lung involvement (p-value: .884) or the CT-SS (Pearson's coefficient: -.111). Yet, patients with radiological findings on the cCT typical for COVID-19 did not present significantly different OF from the remaining (p-value: .193). Conclusions: Olfactory dysfunction does not correlate with the radiological lung involvement in patients hospitalized with COVID-19. SIGNIFICANCE: There is also clinical evidence that the olfactory disorder and the pulmonary disease in COVID-19 have distinct mechanisms.Supplemental data for this article is available online at here.


Assuntos
COVID-19/diagnóstico , Pulmão/diagnóstico por imagem , Radiografia Torácica/métodos , SARS-CoV-2 , Olfato/fisiologia , Tomografia Computadorizada por Raios X/métodos , COVID-19/epidemiologia , COVID-19/fisiopatologia , Estudos Transversais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias
11.
Acta Radiol ; 61(7): 868-874, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31698930

RESUMO

BACKGROUND: Appropriate mammary positioning is an important factor in optimizing image quality in mammography (MMG). PURPOSE: To study the correlation of quality criteria and breast density classification proposed by the American College of Radiology (ACR) and European Guidelines and its influence to achieve a proper positioning, therefore an adequate MMG. MATERIAL AND METHODS: A total of 128 routine MMG examinations were reviewed for the definition of breast composition parenchyma and assessment of several quality criteria proposed by the ACR and European Guidelines to achieve an adequate MMG. Adequate MMG was defined as a difference between the posterior nipple line (PNL), difference of the mediolateral oblique (MLO) and craniocaudal (CC) incidences > 1 cm. The quality criteria were analyzed as a function of correlation coefficient in order to evaluate the individual impact of each factor and analysis of variance (ANOVA) for all criteria. Receiver operating characteristic (ROC) curves were plotted to evaluate the performance of the criteria on each type of parenchyma. RESULTS: Negative correlation of fatty breasts and visibility of the mammary angle, a greater number of skin folds and PNL > 1 cm (r < 0). Dense MMG presented less visibility of the lateral tissue compared with other categories. Area under the curve of ROC analysis revealed values of 53.1% and 54.7% for the right and left breasts, respectively. CONCLUSION: Several factors influenced in the MMG process, but we find that breast parenchyma has a substantial role in affecting these criteria and therefore a correct position for diagnosis, which could compromise MMG diagnostic performance.


Assuntos
Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Posicionamento do Paciente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fidelidade a Diretrizes , Humanos , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador
12.
Radiat Prot Dosimetry ; 192(4): 526-529, 2020 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-33511989

RESUMO

Brain trauma patients who underwent decompressive craniectomy make several computed tomography (CT) scans until cranioplasty. Despite several recommendations to avoid unnecessary radiological exposure, few studies systematically analyzed the technical parameters employed. CT exams of 14 patients were retrospectively analyzed to find display field of view (DFOV), dose length product (DLP), volume computed tomography dose index (CTDIvol) and effective dose (ED). The values obtained were: 120 kVp [95% confidence interval (CI) of 0.5], 297 mA (95% CI of 5.6), scan range 20.8 cm (95% CI of 1.3), DFOV 24.5 cm (95% CI of 1.6), CTDIvol 67.5 mGy (95% CI of 10.17), DLP 1404.8 mGy.cm (95% CI of 235.0) and ED 2.9 mSv (95% CI of 0.5). In conclusion, these values were above the recommendations of several guidelines and raise concern for excessive radiological exposure in trauma patients despite being previously reported in the literature.


Assuntos
Lesões Encefálicas Traumáticas , Craniectomia Descompressiva , Exposição à Radiação , Lesões Encefálicas Traumáticas/diagnóstico por imagem , Humanos , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
13.
Urologia ; 86(4): 189-196, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31303145

RESUMO

OBJECTIVE: Prostate cancer has a high prevalence and mortality, being the most diagnosed urologic cancer. Prostatic magnetic resonance imaging showed high sensitivity in the detection of clinically significant neoplasia and agreement with the Gleason score. Therefore, we attempted to evaluate the diagnostic accuracy of the prostate imaging reporting and data system, using biopsy and prostatectomy as the reference standard. The secondary goal of correlating prostatic magnetic resonance imaging findings and anatomopathological samples is obtained. MATERIALS AND METHODS: We retrospectively analyzed seventy-nine 1.5 Tesla prostatic magnetic resonance imaging scans in patients aged 31 to 86 years, performed at the Clinical Hospital of the Federal University of Paraná between January 2015 and February 2018. RESULTS: Considering all 79 patients, prostatic magnetic resonance imaging was able to diagnose tumor in 47 patients (59.4%). Considering the peripheral zone, the prostatic magnetic resonance imaging had a sensitivity of 75.0% (95% confidence interval: 52.1%-98.0%), specificity of 89.5% (95% confidence interval: 66.0%-100%), 94.4% positive predictive value (95% confidence interval: 71.0%-100%), 66.7% negative predictive value (95% confidence interval: 43.0%-69.0%), 83.8% Positive Likelihood Ratio (PVR) (95% confidence interval: 60.0%-100%), 27.9% Negative Likelihood Ratio (RVN) (95% confidence interval: 5.0%-50.0 %), and accuracy of 86.3% (95% confidence interval: 63.0%-100%). The receiver operating characteristic curve obtained demonstrated the sensitivity variation according to the prostate imaging reporting and data system score of the patients, obtaining an area under the curve of 84.8 for a prostate imaging reporting and data system cutoff of 3. CONCLUSION: The use of the prostate imaging reporting and data system score is useful for the screening and classification of prostate cancer, due to its easy reproducibility, even in a population with an unknown prostate cancer prevalence, which can be easily correlated with biopsy studies and/or radical prostatectomy.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Correlação de Dados , Sistemas de Dados , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Prostatectomia , Neoplasias da Próstata/cirurgia , Reprodutibilidade dos Testes , Projetos de Pesquisa , Estudos Retrospectivos
14.
Acta Radiol Open ; 7(12): 2058460118815726, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30619625

RESUMO

BACKGROUND: Image-guided charcoal injection in suspicious breast lesions for preoperative localization is a procedure that has been increasing over the years because it is safer, faster, and more affordable when compared to needle-wire preoperative localization. To date, no complications have been associated with the method. However, in recent years there have been some reports about charcoal granulomas mimicking malignant lesions in some postoperative patients or in a conservative follow-up. PURPOSE: To report a series of 11 cases which had suspicious imaging findings for malignancy and resulted in charcoal granulomas on histopathological analysis. MATERIAL AND METHODS: A database of 1650 patients that attended our center from January 2007 to June 2018 was reviewed and detected 495 patients who had been previously submitted to ultrasound-guided charcoal marking in a breast lesion. Then, patients whose imaging studies were compatible with new suspicious lesions on mammography, breast ultrasound, and/or magnetic resonance imaging and biopsy of this new lesion indicating charcoal granuloma were selected. RESULTS: From 495 patients who had undergone charcoal localization injections in previous biopsies, we selected 11 who had new lesions with malignant characteristics on imaging studies but histopathological analysis resulted in charcoal granuloma. CONCLUSION: Charcoal granuloma should be considered in patients with previous preoperative injection localization, since the residual charcoal in the breast tissue may form granulomas and mimic malignant lesions on follow-up imaging studies.