Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Int. j. odontostomatol. (Print) ; 15(4): 835-842, dic. 2021. tab, ilus
Artigo em Inglês | LILACS | ID: biblio-1385832

RESUMO

The aim of this study was to evaluate intraoral scanners accuracy in full-arches, comparing them with conventional impressions. A scientific research performed in MEDLINE, EBSCOhost, and SciELO databases was conducted to analyze articles published between 2015 and 2020. Clinical and in vitro studies that evaluated accuracy (precision and trueness) from intraoral scanners and conventional impressions in full-arches were included. Two tests were applied to evaluate the methodological bias from the studies. Out of the 191 articles found, seven of them were selected for a qualitative analysis. In clinical studies,intraoral scanners CEREC Omnicam and 3Shape TRIOS Colorhad the highest precision compared to conventional irreversible hydrocolloid impressions. In in vitro studies, conventional polyvinyl siloxane impressions showed the highest accuracy, followed by intraoral scanners Cadent iTero and CEREC Omnicam, while irreversible hydrocolloid impressions showed the lowest accuracy. Digital intraoral impression systems do not show superior accuracycompared to highly accurate conventional impression techniques. However, they provide excellent clinical results and both methods are clinically accepted.


El objetivo de este estudio fue evaluar la exactitud de escáneres intraorales en impresiones digitales de arco completo en comparación con las impresiones convencionales. Se realizó una revisión sistemática en las bases de datos MEDLINE, EBSCOhost y SciELO para analizar artículos publicados entre los años 2015 y 2020. Se incluyeron estudios clínicos e in vitro que evaluaran exactitud (precisión y/o veracidad) de escáneres intraorales impresiones convencionales en arcos completos. Dos pautas se aplicaron para evaluar el riesgo de sesgo de los estudios. De 191 artículos encontrados, 7 fueron seleccionados para un análisis cualitativo. En los estudios clínicos, los escáneres intraorales CEREC Omnicam y 3Shape TRIOS Color presentaron la mayor precisiónen comparación con las impresiones convencionales de hidrocoloide irreversible. En los estudios in vitro, las impresiones de polivinil siloxano presentaron la mayor exactitud seguido por los escáneres intraorales CadentiTero y CEREC Omnicam, mientras quelas impresiones de hidrocoloide irreversible presentaron la menor exactitud. Los sistemas de impresión digital intraoral no mostraron tener una exactitud superior comparados con las técnicas de impresión convencional de gran exactitud. Sin embargo, proveen excelentes resultados clínicos y ambos métodos son clínicamente aceptables.


Assuntos
Humanos , Arco Dental/diagnóstico por imagem , Técnicas In Vitro , Técnica de Moldagem Odontológica , Desenho Assistido por Computador , Seleção de Pacientes , Imageamento Tridimensional , Materiais para Moldagem Odontológica
2.
J Sports Sci ; 35(9): 906-911, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27373807

RESUMO

Hand paddles and parachutes have been used in order to overload swimmers, and consequently increase the propulsive force generation in swimming. However, their use may affect not only kinematical parameters (average speed, stroke length and stroke rate), but also time gaps between propulsive phases, assessed through the index of coordination (IdC). The objective of this study was to assess the effects of hand paddles and parachute use, isolated or combined, on kinematical parameters and coordination. Eleven swimmers (backstroke 50-m time: 29.16 ± 1.43 s) performed four 15-m trials in a randomised order at maximal intensity: (1) without implements (FREE), (2) with hand paddles (HPD), (3) with parachute (PCH) and (4) with hand paddles plus parachute (HPD+PCH). All trials were video-recorded (60 Hz) in order to assess average speed, stroke rate, stroke length, five stroke phases and index of coordination. When average swimming speed was compared to FREE, it was lower in PCH and HPD+PCH, and higher in HPD. Stroke rate decreased in all overloaded trials compared to FREE. The use of hand paddles and parachute increased and decreased stroke length, respectively. In addition, propulsive phase duration was increased when hand paddles were used, and time gaps shifted towards zero (no time gap), especially when hand paddles were combined with parachute. It is conceivable that the combined use of hand paddles and parachute, once allowing overloading both propulsive and resistive forces, provides a specific stimulus to improve muscle strength and propulsive continuity.


Assuntos
Braço/fisiologia , Mãos/fisiologia , Destreza Motora/fisiologia , Treinamento Resistido/instrumentação , Natação/fisiologia , Fenômenos Biomecânicos , Humanos , Masculino , Treinamento Resistido/métodos , Equipamentos Esportivos , Adulto Jovem
3.
Int. j. morphol ; 33(3): 831-834, Sept. 2015. ilus
Artigo em Inglês | LILACS | ID: lil-762550

RESUMO

This study compared anthropometric parameters among different military sports. One hundred and seventy male cadets of the Brazilian Air Force Academy, who were participants of athletics (n= 33, 20.5±1.3 years), basketball (n= 11, 19.9±1.8 years), fencing (n= 10, 19.9±0.7 years), soccer (n= 21, 20.9±1.6 years), judo (n= 17, 20.7±1.0 years), swimming (n= 15, 20.4±1.2 years), orienteering (n= 10, 21.3±1.6 years), military pentathlon (n= 11, 20.7±1.2 years), water polo (n=10, 21.1±0.9 years), shooting (n= 18, 21.3±1.2 years) or volleyball (n= 14, 20.9±1.7 years) military competitive teams, participated in this study. Height, body mass, body mass index, fat percentage, lean body mass, fat mass, waist and hip perimeters, and waist-hip ratio were measured. Main effects were detected for height, body mass, body mass index, lean body mass, waist and hip perimeters. The only significant finding was that orienteers present lower lean body mass than volleyball and water polo players. These results point out the homogeneity of group anthropometric parameters (except lean body mass), suggesting that military coaches do not rely on the anthropometric parameters, but on specific skills demonstrated during initial period of practice to choose athletes for their teams.


Este estudio comparó los parámetros antropométricos entre cadetes que practican diferentes deportes militares. Ciento setenta cadetes hombres de la Academia de la Fuerza Aérea, que eran participantes de equipos militares competitivos de atletismo (n= 33, 20,5±1,3 años), baloncesto (n= 11, 19,9±1,8 años), esgrima (n= 10, 19,9±0,7 años), fútbol (n=21, 20,9±1,6 años), judo (n= 17, 20,7±1,0 años), natación (n= 15, 20,4±1,2 años), orientación (n= 10, 21,3±1,6 años), pentatlón militar (n= 11, 20,7±1,2 años), polo acuático (n= 10, 21,1±0,9 años), tiro (n= 18, 21,3±1,2 años) y voleibol (n= 14, 20,9±1,7 años) participaron en este estudio. Se midió la altura, masa corporal, índice de masa corporal, porcentaje de grasa corporal, masa magra, masa grasa, perímetros de cintura y cadera, y la relación cintura-cadera. No se detectaron variaciones de altura, masa corporal, índice de masa corporal, masa magra corporal, perímetro de cintura y cadera. El único hallazgo significativo fue que los orientadores tenían una masa corporal magra más baja que los jugadores de voléibol y polo acuático. Estos resultados apuntan a la homogeneidad de los parámetros antropométricos en grupos (excepto la masa magra), lo que sugiere que los instructores militares no dependen de los parámetros antropométricos, sino de las habilidades específicas demostradas durante el período de la práctica inicial en la selección de los atletas para sus equipos.


Assuntos
Humanos , Masculino , Adulto Jovem , Antropometria , Militares , Esportes , Composição Corporal , Brasil
4.
Int J Sports Physiol Perform ; 10(7): 848-52, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25671844

RESUMO

PURPOSE: To assess swimmers' session rating of perceived exertion (sRPE) after standardized sets of interval swimming training performed at the same relative intensity but with different total volume and repetition distance. METHODS: Thirteen moderately trained swimmers (21.1 ± 1.1 y, 178 ± 6 cm, 74.1 ± 8.3 kg, 100-m freestyle 60.2 ± 2.9 s) performed 4 standardized sets (10 × 100-m, 20 × 100-m, 10 × 200-m, and 5 × 400-m) at the same relative intensity (ie, critical speed), and 1 coach (age 31 y, 7 y coaching experience) rated their efforts. Swimmers' sRPE was assessed 30 min after the training session. Coach sRPE was collected before each training session. Internal load was calculated by multiplying sRPE by session duration. RESULTS: When bouts with the same repetition distance and different volumes (10 × 100-m vs 20 × 100-m) are compared, sRPE and internal load are higher in 20 × 100-m bouts. When maintaining constant volume, sRPE and internal load (20 × 100-m, 10 × 200-m, and 5 × 400-m) are higher only in 5 × 400-m bouts. The coach's and swimmers' sRPE differed in 10 × 200-m and 5 × 400-m. CONCLUSIONS: These results indicate that sRPE in swimming is affected not only by intensity but also by volume and repetition distance. In addition, swimmers' and the coach's sRPE were different when longer repetition distances were used during training sessions. Therefore, care should be taken when prescribing swimming sessions with longer volume and/or longer repetition distances.


Assuntos
Percepção , Educação Física e Treinamento/métodos , Esforço Físico/fisiologia , Natação/fisiologia , Natação/psicologia , Humanos , Masculino , Adulto Jovem
5.
J Sports Sci ; 33(10): 1084-92, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25583184

RESUMO

This study investigated the effects of hand paddles, parachute and hand paddles plus parachute on the inter-limb coordination of butterfly swimming. Thirteen male swimmers were evaluated in four random maximal intensity conditions: without equipment, with hand paddles, with parachute and with hand paddles + parachute. Arm and leg stroke phases were identified by 2D video analysis to calculate the total time gap (T1: time between hands' entry in the water and high break-even point of the first undulation; T2: time between the beginning of the hand's backward movement and low break-even point of the first undulation; T3: time between the hand's arrival in a vertical plane to the shoulders and high break-even point of the second undulation; T4: time between the hand's release from the water and low break-even point of the second undulation). The swimming velocity was reduced and T1, T2 and T3 increased in parachute and hand paddles + parachute. No changes were observed in T4. Total time gap decreased in parachute and hand paddles + parachute. It is concluded that hand paddles do not influence the arm-to-leg coordination in butterfly, while parachute and hand paddles + parachute do change it, providing a greater propulsive continuity.


Assuntos
Braço/fisiologia , Perna (Membro)/fisiologia , Destreza Motora/fisiologia , Equipamentos Esportivos , Natação/fisiologia , Fenômenos Biomecânicos , Humanos , Masculino , Análise e Desempenho de Tarefas , Gravação em Vídeo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA