RESUMO
Background: Tuberculosis (TB) is still a threat to public health; in 2014 caused 1.5 million deaths worldwide; in hospitals where the prevalence of TB is low, it is appropriate to evaluate the effectiveness of tests to diagnose it. Methods: We reviewed reports of airway clinical specimens sent for studies of tuberculosis to the microbiology laboratory from Tec Salud System private hospitals (400 beds) in the metropolitan area of ââMonterrey, NL, from May 2012 to December 2015. In conjunction with Ziehl-Neelsen (ZN) stain, and solid Lowenstein-Jensen medium (LJ), our laboratory resources also include fluorescent LED microscopy (Carl Zeiss Microscopy Products), MGIT 320 (Mycobacteria Growth Indicator Tube liquid culture detection system, Becton Dickinson), and recently incorporated a real-time PCR system the Xpert MTB/RIF test (Cepheid, Sunnyvale, CA). Results: In 731 respiratory specimens from 510 patients, M. tuberculosis was isolated from 78 samples belonging to 50 patients on LJ and MGIT LJ 42 (84%) and MGIT 49, (98%) of the samples. From 41 patients identified, 26 (63.4%) were positive to fluorescein, and 25 (60.9%) with Ziehl-Neelsen stain. Real time PCR (Xpert TB) was positive in 13 out of 17 patient-airway samples (76.4%). Conclusions: Usefulness of liquid culture (MGIT) and solid culture (LJ) is shown; the first can significantly cut incubation times.
Introducción: la tuberculosis (TB) aún es una amenaza para la salud pública; en 2014 causó 1.5 millones de muertes a nivel mundial. En hospitales donde la prevalencia de TB es baja, resulta conveniente evaluar la efectividad de las pruebas para diagnosticarla. Métodos: revisamos los informes de resultados de muestras de vías respiratorias enviadas para estudios de tuberculosis de mayo de 2012 a diciembre de 2015 al laboratorio de Microbiología del Sistema Tec Salud (400 camas) en el área metropolitana de Monterrey. Además de la tinción de Ziehl-Neelsen (ZN) y cultivo sólido de Lowenstein-Jensen (LJ); se realizó fluorescencia LED, cultivo en medio líquido MGIT 320 y más recientemente el Xpert MTB/RIF test. Resultados: se cultivaron en LJ y MGIT 731 muestras de vías respiratorias de 510 pacientes; en las muestras de 50 de ellos se identificó M. tuberculosis, 49 en MGIT (98%) y 42 en LJ (84%). De las muestras correspondientes a 41 pacientes, 26 (63.4%) fueron positivas con fluoresceína, y 25 (60.9%) con ZN. En las muestras de 17 pacientes se hizo PCR en tiempo real (Xpert MTB), 13 fueron positivas (76.4%). Conclusiones: se demuestra la utilidad del cultivo en medio liquido (MGIT) y del LJ en medio sólido; el primero, además de ser más sensible, permite acortar en forma importante los tiempos de incubación.
Assuntos
Técnicas Bacteriológicas/métodos , Tuberculose/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Hospitais Privados , Humanos , Incidência , Masculino , México/epidemiologia , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Tuberculose/epidemiologia , Adulto JovemRESUMO
BACKGROUND: Harboring a high mortality, the incidence of sepsis is increasing; thus detection, identification and susceptibility tests of the involved microorganisms become urgent. METHODS: We reviewed the records from January 2013 until July 2014 of a total of 4110 blood culture bottles taken from adult patients in a private tertiary hospital. RESULTS: Growth of microorganisms was observed in 559 bottles (12.6%). We emphasize that 2648 blood cultures (60%) were taken in two paired aerobic and anaerobic bottles drawn at the same time (1324 pairs); from these, growth was observed in 182 inoculated bottles drawn from two different sites at the same time from 135 patients (13.7%). In 86 pairs of bottles with samples from 54 patients (40%), growth occurred only in the aerobic blood culture bottles. Also, growth of microorganisms was observed only in anaerobic bottles in 24 pairs (13.19%), corresponding to 21 patients (15.5%, p<0.05%). In blood cultures from 32 out of 60 patients with growth in both media (53%), microbial growth was detected first in the anaerobic bottle. CONCLUSIONS: The usefulness of blood cultures for anaerobes for the identification of obligate anaerobic bacteremia which rarely occur is low (2.2% of patients with bacteremia); however, in 15.55% of the patients the risk of completely overlook bacteremia was present, and in 53% of patients with positive cultures, bacteremia was established earlier, and thus permitted earlier and accurate decision making.
Introducción: la frecuencia de la septicemia va en aumento y su mortalidad es alta; por lo tanto, su detección, la identificación del microorganismo causal y su susceptibilidad son perentorias. Metodos: se revisaron los registros de 4110 botellas de cultivo de sangre obtenida de enero de 2013 a julio de 2014 de pacientes adultos en un hospital privado de tercer nivel. Resultados: se observó crecimiento de microorganismos en 559 cultivos (12.6 %). En 2648 hemocultivos (60 %) inoculados en pares de frascos uno con medio aeróbico y el otro anaeróbico (1324 sets), se detectó crecimiento en 182 frascos a los que les fueron inoculadas las muestras tomadas al mismo tiempo a 135 pacientes (13.7 %). En 86 pares de frascos con las muestras de 54 pacientes (40 %), el crecimiento solamente se dio en el frasco aeróbico (47.5 %); en 24 pares de frascos (13.19 %) tomados a 21 pacientes (15.5 %, p < 0.05), solamente hubo crecimiento en el frasco anaeróbico. En los hemocultivos de 32 de 60 pacientes con crecimiento en ambos frascos (53 %), el crecimiento se detectó primero en el frasco anaeróbico. Conclusiones: los hemocultivos anaeróbicos tienen una utilidad baja para la detección de bacteriemias por anaerobios estrictos; no obstante, en el 15.55 % de los pacientes estuvo presente el riesgo de pasar por alto la presencia de bacteriemia, y en 53 % de los pacientes con hemocultivos positivos, el diagnóstico de bacteriemia pudo establecerse de manera más temprana, lo que permitió anticipar con mejor precisión la toma de decisiones.