Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 188
Filtrar
1.
Braz Dent J ; 35: 5824, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39045990

RESUMO

This study evaluated the setting time, pH, calcium ion release, solubility, and chemical structure of four calcium silicate sealers after ultrasonic activation (UA). Five sealers were evaluated: Sealer Plus (SP - control); Sealer Plus BC (SPBC), Bio C Sealers (BCS), Endosequence BC Sealer (EBC), and BioRoot RCS (BR). Ten groups were created based on the use or not of ultrasonic activation: SP; SP/UA; SPBC; SPBC/UA; BCS; BCS/UA; EBC; EBC/UA; BR; and BR/UA. Setting time was performed based on ISO 6876:2012 and ASTM C266-07 specifications. Solubility at 24hs, based on ISO 6876:2012. pH and calcium release were evaluated at 1, 24, 72, and 168hs. Raman spectroscopy was used to evaluate structural changes. Quantitative data were analyzed using One-Way ANOVA and Tukey post-hoc test (α=5%). Raman spectroscopy results were qualitatively analyzed. Setting times and solubility of all sealers were not affected by UA (p>0.05). The highest solubility was found for BCS, BCS/UA; and BR, BR/UA (p<0.05). After 24hs, calcium silicate sealers had higher pH than SP and SP/UA (p<0.05). BR and BR/UA had the highest pH at all time points. SP and SP/UA had stable pH at all time points. SP and SP/UA had the lowest calcium release values at all time points (p<0.05). EBC and EBC/UA calcium release significantly differ at 24,72 and 168hs (p<0.05). No chemical changes were observed during Raman spectroscopy. In conclusion, ultrasonic activation affected calcium ion release only for EndoSequence BC Sealer. Ultrasonic activation did not influence the initial and final setting time, solubility, pH, and chemical structure of any investigated sealers.


Assuntos
Compostos de Cálcio , Cálcio , Materiais Restauradores do Canal Radicular , Silicatos , Solubilidade , Concentração de Íons de Hidrogênio , Silicatos/química , Compostos de Cálcio/química , Cálcio/química , Materiais Restauradores do Canal Radicular/química , Ultrassom , Análise Espectral Raman
2.
Restor Dent Endod ; 49(2): e22, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38841387

RESUMO

Objectives: This systematic review addressed the question: "What is the prevalence of apical periodontitis in patients prior to hematopoietic cell transplantation?" Materials and Methods: A systematic search was conducted in MEDLINE/PubMed, Cochrane Library, Scopus, Web of Science, Embase, and Grey Literature Report. Eligibility criteria were based on the condition, content, and population strategy: the condition was the radiographic prevalence of apical periodontitis, the content comprised patients scheduled for hematopoietic stem cell transplantation, and the population consisted of adult and pediatric patients. The revised Risk of Bias in Nonrandomized Studies of Exposure tool was used to assess the quality of studies. The Grading Recommendations Assessments, Development, and Evaluation (GRADE) tool was used to assess the quality of evidence. Results: Eight studies were included in this review. The average number of patients with apical periodontitis was 15.65% (range, 2.1%-43.34%). One study was classified as having a very high risk of bias, 1 with a high risk of bias, and 6 with some concern for bias. GRADE analysis showed a very low certainty of evidence. Significant limitations concerning the absence of control over confounding variables were identified. Conclusions: With the caveat of the very low quality of evidence in the studies reviewed, there was a low to moderate prevalence of apical periodontitis in patients prior to undergoing hematopoietic cell transplantation.

3.
J. res. dent ; 12(1): 1-8, Jun 2024.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1556278

RESUMO

Aims: This study aimed to evaluate the intraoperative pain (IOP) occurrence in situations of symptomatic irreversible pulpitis (SIP) and symptomatic apical periodontitis (SAP). Materials and Methods: Patients who sought emergency care presenting a diagnosis of SIP or SAP were included. IOP was measured with a Visual Analogue Scale (VAS) after five minutes of local anesthesia, during access to the pulp chamber, root canal exploration and at the end of procedures. In cases where pain was reported during treatment, supplementary anesthesia was performed. Pain scores were recorded and analyzed using a generalized estimating equation model with posthoc comparisons. Results: 56 patients were included. 35 had a diagnosis of SIP; and 21 a diagnosis of SAP. Mean preoperative pain scores for SAP and SIP were 6.69 (±1.54) and 6.39 (±1.48), respectively (p>0.05). In patients with SIP, significant differences were observed between: preoperative scores and other time points; scores after five minutes of local anesthesia and other time points; scores during pulp chamber access and at the end of procedures; and scores during root canal exploration and at the end of procedures (p<0.05). In patients with SAP, significant differences were observed between preoperative pain scores with all other time points (p<0.05). Chi-square test indicated an association between diagnosis and the need for supplementary anesthesia (p<0.05). Conclusions: In conclusion, there is a strong relationship between reduction of moderate/severe pain after application of local anesthesia. The need for supplemental anesthesia is significantly associated to the diagnosis of symptomatic irreversible pulpitis.

4.
Eur Endod J ; 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38820458

RESUMO

Assessing scientific literature about prevalence of periapical lesions in individuals with osteoporosis in comparison to those without osteoporosis. Systematic searches were conducted up to November 24th, 2023 in Cochrane Library, EMBASE, MEDLINE/PubMed, SCOPUS, Web of Science and Grey Literature Reports databases. Only observational studies were included. The ROBINS-E tool, a revised Cochrane instrument for assessing bias in nonrandomized exposure studies, was employed. The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) tool was utilized to evaluate the certainty of the evidence. From 484 studies, three were included. One of them was categorized as having an exceptionally high risk of bias, while two were deemed to have certain concerns. Two studies reported that osteoporotic patients may have more chances to present a periapical lesion compared to non-osteoporotic patients. One study reported no differences between groups. The GRADE analysis indicated a markedly low level of certainty in the evidence. The present review indicates that osteoporotic patients may present more periapical lesions compared to non-osteoporotic patients. This statement should be cautiously interpreted and further well-designed studies are needed. (EEJ-2023-09-123).

5.
Braz Dent J ; 35: e245720, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38775593

RESUMO

This study evaluated a new method of adhesive system application on the bond strength between fiber post and root dentin using two adhesive systems. The canals of sixty bovine incisors were prepared and obturated. The roots were divided into six groups (n=10) according to the adhesive system (Clearfil SE - CSE and Single Bond Universal - SBU) and the application strategy (microbrush - MB; rotary brush - RB; and ultrasonic tip - US). The glass fiber posts were cemented with resin cement (RelyX ARC). The roots were sectioned perpendicularly to their long axis, and three slices per root were obtained. Previously to the push-out test, confocal laser scanning microscopy (CLSM) was performed to illustrate the interfacial adaptation of the cement to the root canal walls. Failure patterns were analyzed with 40x magnification. Shapiro-Wilk indicated a normal distribution of the data. The bond strength values were compared using one-way ANOVA and Tukey's tests. Student's T test analyzed the differences between the adhesive systems within each third and protocol. A significance level of 5% was used. CSE with RB showed higher mean bond strength values compared to MB (conventional technique) (P < 0.05). US application resulted in intermediate bond strength values for CSE (P > 0.05). The application of SBU using RB generated higher mean bond strength values compared to MB and US (P < 0.05). Adhesive failures were predominant (65.5%). CSE and SBU application with the new rotary brush improved the bond strength of fiber posts to root dentin compared to the conventional strategy.


Assuntos
Dentina , Técnica para Retentor Intrarradicular , Cimentos de Resina , Bovinos , Animais , Cimentos de Resina/química , Colagem Dentária/métodos , Bis-Fenol A-Glicidil Metacrilato/química , Adesivos Dentinários/química , Microscopia Confocal , Ácidos Polimetacrílicos/química , Teste de Materiais , Vidro/química , Raiz Dentária , Polietilenoglicóis/química , Análise do Estresse Dentário
6.
Iran Endod J ; 19(2): 61-74, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38577002

RESUMO

Introduction: The current study aimed to compare the quality of root canal obturation performed with cold lateral condensation with other obturation techniques. Materials and Methods: Diverse Search was conducted using six electronic/academic databases following PICOS (i.e. population, intervention, control, outcomes, and study design) strategy: (P) Extracted mature permanent teeth; (I) Obturation techniques except for cold lateral condensation; (C) Cold lateral condensation tyechnique; (O) Quality of root canal obturation; and (S) In vitro studies assessing parameters using micro-computed tomography. The statistical method used for the meta-analyses was the "inverse variance DerSimonian-Laird test". The heterogeneity data was calculated using the T2, Cochran Q test, and I2 statistics. Results: Fifteen studies were included for the final analysis; one had a low risk of bias, eight a moderate risk, and six a high risk of bias. Ten studies were selected for meta-analyses; three studies comparing cold lateral condensation with carrier-based gutta-percha techniques [P=0.96; mean difference (MD)=-0.02; confidence interval (CI): (-0.77, 0.73); I2=21%]; three comparing cold lateral condensation with single-cone techniques [P=0.75; MD=-0.39; CI: (-2.77, 1.99); I2=92%]; two comparing cold lateral condensation and thermo-plasticized injectable techniques [P=0.37; MD=5.91; CI: (-7.13,18.94); I2=99%]; and five comparing cold lateral condensation with warm vertical condensation techniques [P<0.0001; MD=5.29; CI=(2.84, 7.74); I2=92%]. The overall effect reported significant results [P=0.0003; MD=2.69; CI=(1.23, 4.16); I2=96%]; favoring fewer voids and gaps for the other used obturation techniques. Conclusions: Cold lateral condensation and single-cone techniques presented no statistical differences. Nonetheless, Warm vertical condensation technique had better results compared to cold lateral condensation.

7.
Microsc Res Tech ; 87(1): 172-178, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37732407

RESUMO

AIM: This study aimed to use the micro-computed tomography to evaluate the interfacial adaptation and the presence of gaps of NeoMTA Plus, BioRoot RCS, and MTA in the root-end cavities. METHODOLOGY: Thirty standardized bovine roots measuring 15 mm in length were selected. Chemical-mechanical preparation was performed up to instrument #80 and obturation with the cold lateral compaction technique with cement based on zinc oxide and eugenol. The roots were kept at 37°C for 7 days. Afterward, apicectomy of the apical 3 mm and a root-end filling cavity was performed at 3 mm depth. Micro-computed tomography (micro-CT) was performed to measure the volume of the retroactivity. The roots were divided by stratified randomization into three groups according to the retro-end filling material: NeoMTA Plus, BioRoot RCS, and MTA. A new micro-CT was performed to assess the presence of voids in the root-end filling material and between it and the canal wall. One-way ANOVA and Tukey tests were performed using the BioEstat 4.0 program. RESULTS: There was no difference in the initial volume values of the root-end cavities (p > .05). After the insertion of root-end filling materials, the most significant volumes of voids were observed in the NeoMTA Plus group (p < .05), with no difference for the BioRoot RCS and MTA Angelus groups (p > .05). CONCLUSION: Micro-computed tomography showed that MTA and BioRoot RCS have better interfacial adaptation and presented fewer number of gaps than NeoMTA Plus when used as root-end filling materials. RESEARCH HIGHLIGHTS: Micro-computed tomography evaluation of different root-end fillings materials.


Assuntos
Materiais Restauradores do Canal Radicular , Animais , Bovinos , Microtomografia por Raio-X/métodos , Compostos de Cálcio , Guta-Percha , Obturação do Canal Radicular , Silicatos , Cavidade Pulpar
8.
Braz. dent. j ; Braz. dent. j;35: e24, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1557212

RESUMO

Abstract This study evaluated a new method of adhesive system application on the bond strength between fiber post and root dentin using two adhesive systems. The canals of sixty bovine incisors were prepared and obturated. The roots were divided into six groups (n=10) according to the adhesive system (Clearfil SE - CSE and Single Bond Universal - SBU) and the application strategy (microbrush - MB; rotary brush - RB; and ultrasonic tip - US). The glass fiber posts were cemented with resin cement (RelyX ARC). The roots were sectioned perpendicularly to their long axis, and three slices per root were obtained. Previously to the push-out test, confocal laser scanning microscopy (CLSM) was performed to illustrate the interfacial adaptation of the cement to the root canal walls. Failure patterns were analyzed with 40x magnification. Shapiro-Wilk indicated a normal distribution of the data. The bond strength values were compared using one-way ANOVA and Tukey's tests. Student's T test analyzed the differences between the adhesive systems within each third and protocol. A significance level of 5% was used. CSE with RB showed higher mean bond strength values compared to MB (conventional technique) (P < 0.05). US application resulted in intermediate bond strength values for CSE (P > 0.05). The application of SBU using RB generated higher mean bond strength values compared to MB and US (P < 0.05). Adhesive failures were predominant (65.5%). CSE and SBU application with the new rotary brush improved the bond strength of fiber posts to root dentin compared to the conventional strategy.


Resumo Este estudo avaliou o efeito de um novo método para aplicação do sistema adesivo na resistência de união entre pino de fibra e dentina radicular usando dois sistemas adesivos. Os canais de sessenta incisivos bovinos foram preparados e obturados. As raízes foram divididas em seis grupos (n=10) de acordo com o sistema adesivo (Clearfil SE - CSE e Single Bond Universal - SBU) e com a estratégia de aplicação (microbrush - MB, escova rotatória - RB e inserto ultrassônico - US). Os pinos de fibra foram cimentados utilizando cimento resinoso (RelyX ARC). As raízes foram seccionadas perpendicularmente ao seu longo eixo e três fatias foram obtidas. Previamente ao teste de push-out, foi realizada microscopia de varredura confocal a laser para ilustrar a adaptação interfacial do cimento às paredes do canal radicular. Os padrões de falha foram analisados com magnificação de 40x. O teste de Shapiro-Wilk indicou distribuição normal dos dados. Os valores de resistência de união foram comparados usando o teste ANOVA de uma via e post hoc de Tukey. As diferenças entre os sistemas adesivos em cada terço e de acordo com cada protocolo foram analisadas pelo teste T de Student. O nível de significância foi de 5%. CSE aplicado com RB apresentou maiores valores médios de resistência de união do que quando aplicado com MB (técnica convencional) (P<0,05). Aplicação com US apresentou valores intermediários de resistência de união para o CSE (P>0,05). A aplicação do SBU utilizando RB gerou maiores valores médios de resistência de união comparados com MB e US (P<0,05). Falhas adesivas foram predominantes (65,5%). A aplicação do CSE e SBU com a nova escova rotatória melhorou a resistência de união dos pinos de fibra à dentina radicular comparados com a estratégia convencional.

9.
Braz. dent. j ; Braz. dent. j;35: e24, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1564087

RESUMO

Abstract This study evaluated the setting time, pH, calcium ion release, solubility, and chemical structure of four calcium silicate sealers after ultrasonic activation (UA). Five sealers were evaluated: Sealer Plus (SP - control); Sealer Plus BC (SPBC), Bio C Sealers (BCS), Endosequence BC Sealer (EBC), and BioRoot RCS (BR). Ten groups were created based on the use or not of ultrasonic activation: SP; SP/UA; SPBC; SPBC/UA; BCS; BCS/UA; EBC; EBC/UA; BR; and BR/UA. Setting time was performed based on ISO 6876:2012 and ASTM C266-07 specifications. Solubility at 24hs, based on ISO 6876:2012. pH and calcium release were evaluated at 1, 24, 72, and 168hs. Raman spectroscopy was used to evaluate structural changes. Quantitative data were analyzed using One-Way ANOVA and Tukey post-hoc test (α=5%). Raman spectroscopy results were qualitatively analyzed. Setting times and solubility of all sealers were not affected by UA (p>0.05). The highest solubility was found for BCS, BCS/UA; and BR, BR/UA (p<0.05). After 24hs, calcium silicate sealers had higher pH than SP and SP/UA (p<0.05). BR and BR/UA had the highest pH at all time points. SP and SP/UA had stable pH at all time points. SP and SP/UA had the lowest calcium release values at all time points (p<0.05). EBC and EBC/UA calcium release significantly differ at 24,72 and 168hs (p<0.05). No chemical changes were observed during Raman spectroscopy. In conclusion, ultrasonic activation affected calcium ion release only for EndoSequence BC Sealer. Ultrasonic activation did not influence the initial and final setting time, solubility, pH, and chemical structure of any investigated sealers.


Resumo Esse estudo avaliou o tempo de presa, pH, liberação de íons cálcio, solubilidade e estrutura química de quatro cimentos à base de silicate de cálcio após a ativação ultrassônica . Cinco cimentos foram avaliados: Sealer Plus (SP - control); Sealer Plus BC (SPBC), Bio C Sealers (BCS), Endosequence BC Sealer (EBC) e BioRoot RCS (BR). Dez grupos foram criados com base no uso ou não de ativação ultrassônica: SP; SP/UA; SPBC; SPBC/UA; BCS; BCS/UA; EBC; EBC/UA; BR; e BR/UA. Tempo de presa foi realizado baseado nas especificações ISO 6876:2012 e ASTM C266-07. Solubilidade em 24hs, baseado na ISO 6876:2012. pH e liberação de cálcio foram avaliados em 1, 24, 72 e 168hs. Espectroscopia Raman foi usada para avaliar alterações estruturais. Os dados quantitativos foram analisados utilizando ANOVA de uma via e teste post-hoc de Tukey (α=5%). Os resultados da espectroscopia Raman foram analisados qualitativamente. Os tempos de presa e a solubilidade de todos os cimentos não foram afetados pelo AU (p>0.05). Maior solubilidade foi encontrada para BCS, BCS/AU; e BR, BR/AU (p<0.05). Após 24hs, os cimentos de silicato de cálcio apresentaram pH mais elevado que SP e SP/AU (p<0.05). BR e BR/AU tiveram o pH mais alto em todos os momentos. SP e SP/AU apresentaram pH estável em todos os momentos. SP e SP/AU tiveram os menores valores de liberação de cálcio em todos os momentos (p<0.05). A liberação de cálcio EBC e EBC/AU diferiram significativamente em 24,72 e 168hs (p<0.05). Nenhuma alteração química foi observada durante a espectroscopia Raman. Em conclusão, a ativação ultrassônica afetou a liberação de íons cálcio apenas para o EndoSequence BC Sealer. A ativação ultrassônica não influenciou o tempo de presa inicial e final, a solubilidade, o pH e a estrutura química de nenhum dos cimentos investigados.

10.
Restor Dent Endod ; 48(4): e37, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38053784

RESUMO

This study aimed to compare the disinfectant ability of chlorhexidine (CHX) gel and sodium hypochlorite (NaOCl). Systematic searches were conducted from inception until December 8th, 2022 (MEDLINE/PubMed, Cochrane Library, Web of Science, Scopus, Embase, and Grey Literature databases). Only randomized clinical trials were included. The revised Cochrane risk of bias tools for randomized trials were used to assess the quality of studies. Meta-analyses were performed. The overall quality of evidence was assessed through the Grading of Recommendations Assessment, Development, and Evaluation tool. Six studies were included. Five had a low risk of bias and 1 had some concerns. Three studies assessed bacterial reduction. Two were included in the meta-analysis for bacterial reduction (mean difference, 75.03 [confidence interval, CI, -271.15, 421.22], p = 0.67; I2 = 74%); and 3 in the meta-analysis for cultivable bacteria after chemomechanical preparation (odds ratio, 1.03 [CI, 0.20, 5.31], P = 0.98; I2 = 49%). Five studies assessed endotoxin reduction. Three were included in a meta-analysis (mean difference, 20.59 [CI, -36.41, 77.59], p = 0.48; I2 = 74%). There seems to be no difference in the disinfectant ability of CHX gel and NaOCl, but further research is necessary.

11.
Braz Dent J ; 34(4): 54-61, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37909642

RESUMO

This study compared the pH and calcium ion release of calcium silicate- (Bio-C Temp) and calcium hydroxide-based (Ultracal XS) medications. Intracanal remnants of both medications were also evaluated using SEM-EDS after the removal protocol. Thirty-five bovine teeth were prepared. Fifteen were filled with Bio-C Temp and 15 with Ultracal XS. Five remained without intracanal medication (control group). Five samples from each experimental time (i.e.. 24, 72, and 168 hours) were used to measure pH and calcium ions release using a digital pH meter and microplate reader, respectively. Afterward, the peaks of the chemical elements composing both medications were analyzed in SEM-EDS. One-way ANOVA and Tukey's post hoc test analyzed the pH and calcium ion release data. Student's t-test compared the medications in each experimental time. SEM-EDS described the percentage of chemical elements in the samples. Bio-C Temp and Ultracal XS showed a significant pH increase from 24 to 168 hours (p<0.05). Ultracal XS showed a higher pH value at 24 hours than Bio-C Temp (p<0.05) but were similar at 72 and 168h (p > 0.05). Calcium ion release did not depend on the experimental period (p > 0.05). Bio-C Temp showed lower calcium ions release than Ultracal XS at 24 hours (p<0.05). SEM-EDS analyses showed the remains of both medications, but the concentration of Si, Al, and W ions was present only in the calcium silicate-based medication. Bio-C Temp presented alkaline pH and a satisfactory calcium ion release over the time. The remaining of both medications were present after the protocols for paste removal.


Assuntos
Cálcio , Materiais Restauradores do Canal Radicular , Animais , Bovinos , Cavidade Pulpar , Hidróxido de Cálcio , Concentração de Íons de Hidrogênio , Bandagens , Análise Espectral , Materiais Restauradores do Canal Radicular/química
12.
J. res. dent ; 11(2): 32-51, Oct 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513037

RESUMO

Aims: To investigate whether bioceramicsealers induce a lower incidence and intensity of postoperative pain compared to other sealers. Materials and Methods: Six electronic databases were searched for studies published up to April 2022, following the PICOS strategy: (P) adult patients undergoing root canal treatment or retreatment; (I) root canal filling using bioceramic sealer; (C) root canal filling using other types of sealers; (O) Primary: postoperative pain incidence and/or intensity; Secondary: number of medication intake; (S) randomizedclinical trials. Risk of bias assessment was performed with the revised Cochrane risk of bias tools for randomized trials (RoB 2). Overall certainty of evidence was assessed through the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) tool. Results: Ten studies were included. Eight studies had a low risk of bias, and two had some concerns risk. Meta-analyses showed no differences regarding postoperative pain intensity and incidence between bioceramic sealers and AH Plus. Number of medication intake seemed to be associated to the preoperative diagnosis. Zinc oxide-eugenol sealer demonstrated an intense postoperative pain compared to bioceramic sealers and AH Plus. GRADE analysis showed a low certainty of evidence for all outcomes. Conclusions: There seem to be no differences between bioceramic sealers and AH Plus regarding postoperative pain intensity and incidence. Number of medication intake seem to be associated to the preoperative diagnosis. Zinc oxide-eugenol evoked a more pronounced postoperative pain.

13.
J. res. dent ; 11(2): 1-19, Oct 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513034

RESUMO

Aims: This systematic review aimed to evaluate whether calcium silicate-based sealers are less cytotoxicity and genotoxicity than epoxy resin-based sealers. Materials and Methods: Systematic searches were conducted for studies published up to September 27th, 2022, without restriction for language or year of publication, in the following databases: MEDLINE/PubMed, Scopus, Web of Science and Grey Literature Report. Only in vitrostudies that evaluated the cytotoxicity or genotoxicity of calcium silicate and epoxy resin-based sealers were included. The quality assessment was performed. Results: After duplicate removal and eligibility criteria assessment, a total of thirty-four studies were included. Twenty-eight studies had a low risk of bias, and six studies had amoderate risk of bias. In general, calcium silicate-based sealers had a lower cytotoxic and genotoxic potential than epoxy-resin based sealers.Conclusions: Based on the findings from in vitrostudies, calcium silicate-based sealers are less cytotoxic andgenotoxic than epoxy resin-based sealers

14.
Clin Oral Investig ; 27(11): 6321-6332, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37728616

RESUMO

OBJECTIVES: Endodontic treatment is one of the most fearful procedures among dentistry, and the use of music during the procedure has been evaluated to control patients' anxiety. This systematic review has been conducted to provide a synthesis of the state of knowledge in this field and aimed to answer the following question: "Can music therapy reduce patient's state anxiety during endodontic treatment?". METHODS: A search was performed in six electronic databases (PubMed, Cochrane Library, Scopus, Web of Science, EMBASE, and Open Gray) for articles published until April 2022. The eligibility criteria, based on the PICOS strategy, were as follows: (P) patients undergoing endodontic treatment; (I) exposure to music; (C) no music; (O) patients' anxiety; (S) only randomized clinical trials. The risk of bias was analyzed according to the Cochrane Risk of Bias tool for randomized controlled trials (RoB 2). The strength of evidence from the included studies was assessed using the Grading of Assessment, Development, and Assessment Recommendations (GRADE) tool. RESULTS: Five eligible studies were retrieved. A low to high risk of bias was verified. Descriptive analysis showed an effect in favor of music intervention, with differences among state anxiety, heart rate and blood pressure. CONCLUSIONS: With a very low quality of evidence, dental care professionals may consider playing background music during endodontic treatment since it is a cost-effective and easy alternative to trying to reduce dental anxiety. CLINICAL RELEVANCE: Five studies were included in this systematic review and showed, with a very low quality of evidence, that music may reduce state anxiety levels on patients during root canal treatment.


Assuntos
Musicoterapia , Música , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Ansiedade , Musicoterapia/métodos , Assistência Odontológica
15.
Restor Dent Endod ; 48(3): e24, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37675444

RESUMO

This review aimed to answer the following question "Does photobiomodulation treatment of the root surface decrease the occurrence of root resorption in reimplanted teeth?" Electronic searches were performed in the MEDLINE/PubMed, Cochrane Library, Scopus, Web of Science, Embase, and Grey Literature Report databases. Risk of bias was evaluated using SYRCLE Risk of Bias tool. The Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) tool was used to assess the certainty of evidence. In total, 6 studies were included. Five studies reported a reduced occurrence of root resorption in teeth that received photobiomodulation treatment of the root surface prior to replantation. Only 1 study reported contradictory results. The photobiomodulation parameters varied widely among studies. GRADE assessment showed a low certainty of evidence. It can be inferred that photobiomodulation treatment of the root surface prior to replantation of teeth can reduce the occurrence of root resorption. Nonetheless, further clinical studies are needed. Trial Registration: PROSPERO Identifier: CRD42022349891.

16.
Microsc Res Tech ; 86(12): 1635-1641, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37587834

RESUMO

This study evaluated the cyclic and torsional fatigue resistance of a new nickel-titanium (Flat File 25.04) instrument on the continuous and reciprocating motion. Sixty instruments of the ProDesign Logic2 25.03 and 25.05 (Easy Equipamentos Odontológicos, Belo Horizonte, Brazil), and MK Flat File 25.04 (n = 20) (MK Life, Porto Alegre, Brazil) were used. For the cyclic fatigue test, an artificial stainless steel simulated canal with an angle of 60° and a radius of curvature of 5 mm located 5 mm from its tip was used. The torque and rotation angle at the instruments' failure on the torsional fatigue test was based on the ISO 3630-1 protocol, in which the 3 mm tip of each instrument was fixed and connected to an electric motor and a load cell. The fractured surface of each fragment was examined by scanning electron microscopy. Data were analyzed using a 1-way analysis of variance and Tukey's test with a significance level of 5%. Flat File 25.04 had lower cyclic fatigue in both kinematics than the Logic instruments (p < .05). Reciprocating motion improved the cyclic fatigue of the tested instruments (p < .05). Flat File 25.04 had similar torque to Logic2 25.05 (p > .05), and both were superior to Logic2 25.03 (p < .05). The angular deflection values were different for the three tested instruments (p < .05), in the decreasing order: Logic2 25.03, 25.05, and Flat File 25.04. Flat File presented good resistance to cyclic and torsional fatigue resistance. Reciprocating motion improved the cyclic fatigue resistance of the instruments and can be considered when using programmable motors. RESEARCH HIGHLIGHTS: Scanning electron microscopy evaluation of different endodontic rotary file and fatigue resistance tests.

17.
Braz. dent. j ; Braz. dent. j;34(4): 54-61, July-Aug. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1520342

RESUMO

Abstract This study compared the pH and calcium ion release of calcium silicate- (Bio-C Temp) and calcium hydroxide-based (Ultracal XS) medications. Intracanal remnants of both medications were also evaluated using SEM-EDS after the removal protocol. Thirty-five bovine teeth were prepared. Fifteen were filled with Bio-C Temp and 15 with Ultracal XS. Five remained without intracanal medication (control group). Five samples from each experimental time (i.e.. 24, 72, and 168 hours) were used to measure pH and calcium ions release using a digital pH meter and microplate reader, respectively. Afterward, the peaks of the chemical elements composing both medications were analyzed in SEM-EDS. One-way ANOVA and Tukey's post hoc test analyzed the pH and calcium ion release data. Student's t-test compared the medications in each experimental time. SEM-EDS described the percentage of chemical elements in the samples. Bio-C Temp and Ultracal XS showed a significant pH increase from 24 to 168 hours (p<0.05). Ultracal XS showed a higher pH value at 24 hours than Bio-C Temp (p<0.05) but were similar at 72 and 168h (p > 0.05). Calcium ion release did not depend on the experimental period (p > 0.05). Bio-C Temp showed lower calcium ions release than Ultracal XS at 24 hours (p<0.05). SEM-EDS analyses showed the remains of both medications, but the concentration of Si, Al, and W ions was present only in the calcium silicate-based medication. Bio-C Temp presented alkaline pH and a satisfactory calcium ion release over the time. The remaining of both medications were present after the protocols for paste removal.


Resumo Este estudo comparou o pH e a liberação de íons cálcio de medicações intracanais a à base de silicato de cálcio (Bio-C Temp) e à base de hidróxido de cálcio (Ultracal XS). Remanescentes de ambas as medicações também foram avaliados usando microscopia eletrônica de varredura e espectroscopia de dispersão de energia após o protocolo de remoção. Trinta e cinco dentes bovinos foram preparados. Quinze dentes foram preenchidos com Bio-C Temp e 15 com Ultracal XS. Cinco permaneceram sem medicação intracanal (grupo controle). Cinco amostras de cada tempo experimental (ou seja, 24, 72 e 168 horas) foram usadas para medir o pH e a liberação de íons de cálcio usando um medidor de pH digital e um leitor de microplacas, respectivamente. Em seguida, os picos dos elementos químicos que compõem os dois medicamentos foram analisados ​​em microscopia eletrônica de varredura e por espectroscopia de dispersão de energia. Os testes One-way ANOVA e post hoc de Tukey analisaram os dados de pH e liberação de íons cálcio. O teste t de Student comparou as medicações em cada tempo experimental. A microscopia eletrônica de varredura e a espectroscopia de dispersão de energia descreveu a porcentagem de elementos químicos nas amostras. O Bio-C Temp e o Ultracal XS mostraram um aumento significativo de pH de 24 a 168 horas (p<0,05). O Ultracal XS apresentou um valor de pH mais alto em 24 horas do que o Bio-C Temp (p<0,05), mas foi semelhante em 72 e 168h (p > 0,05). A liberação de íons cálcio não dependeu do período experimental (p> 0,05). O Bio-C Temp apresentou menor liberação de íons de cálcio do que Ultracal XS em 24 horas (p<0,05). As análises de microscopia eletrônica de varredura e espectroscopia de dispersão de energia mostraram remanescentes de ambas as medicações, mas a concentração de íons Si, Al e W estavam presentes apenas na medicação à base de silicato de cálcio. O Bio-C Temp apresentou pH alcalino e maior liberação de íons cálcio. Remanescentes de ambas as medicações estiveram presentes após os protocolos de remoção da pasta.

18.
Aust Endod J ; 49(3): 524-529, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37439395

RESUMO

This study investigated the cyclic fatigue and torsional resistance of Unicone Plus (UCP 25.06), Unicone (UC 25.06), Reciproc Blue (RB 25.08) and Wave One Gold (WOG 25.07) performed at body temperature (35° ± 1°C). Time and number of cycles to fracture (NCF), as well as torque and angular deflection were recorded. Fractured surfaces were evaluated by scanning electron microscopy (SEM). Data were analysed using one-way ANOVA and Holm-Sidak's tests for multiple comparison. The RB had a significantly higher time to fracture, followed by the WOG and UCP (p < 0.05). Regarding the NCF, there was no significantly difference between RB and WOG (p > 0.05). UC presented highest torque values and the lowest angular deflection (p < 0.05). SEM analysis demonstrated typical failures features in both cyclic and torsional fatigue tests. Overall, UC had the lowest time, NCF and angular deflection at fracture. RB presented the highest time to fracture and angular deflection values.


Assuntos
Ligas Dentárias , Temperatura Alta , Estresse Mecânico , Titânio , Níquel , Instrumentos Odontológicos , Desenho de Equipamento , Preparo de Canal Radicular , Teste de Materiais
19.
Clin Oral Investig ; 27(8): 4117-4129, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37335397

RESUMO

INTRODUCTION: Usually, orthodontic movements encompass children and young adult patients, which are more susceptible to the occurrence of traumatic dental injuries. It is necessary to understand whether the effects of orthodontic movements on traumatized teeth could induce pulp necrosis. The aim of this study was to answer the following question: "Do orthodontic movements of traumatized teeth induce dental pulp necrosis?". MATERIAL AND METHODS: Searches were performed for studies published up to May 11, 2023, in the MEDLINE/PubMed, Cochrane Library, Scopus, SciELO Citation Index, Web of Science, EMBASE, and Grey Literature Report databases, without restriction for language or year of publication. The revised Cochrane risk of bias tools for nonrandomized interventions (ROBINS-I) was used to assess the quality of the included studies. The overall quality of evidence was assessed through the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) tool. RESULTS: Of 2671 potentially relevant studies, five were included. Four were classified as having a moderate risk of bias and one as a serious risk of bias. It was reported a higher susceptibility to pulp necrosis in teeth subjected to orthodontic movements with history of trauma involving periodontal tissues. Additionally, orthodontic movements of traumatized teeth with total pulp obliteration had an increased risk of pulp necrosis. GRADE analysis presented a moderate certainty of evidence. CONCLUSIONS: An increased risk for pulp necrosis when traumatized teeth are subjected to orthodontic movements was verified. However, this is based on evaluations performed with subjective tests. Further well-designed studies are necessary to confirm this trend. CLINICAL RELEVANCE: Clinicians must be aware of the possibility of pulp necrosis. However, endodontic treatment is recommended when verified signs and symptoms of pulp necrosis.


Assuntos
Necrose da Polpa Dentária , Periodonto , Criança , Adulto Jovem , Humanos , Necrose da Polpa Dentária/etiologia , Polpa Dentária
20.
J. res. dent ; 11(1): 14-19, May 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513030

RESUMO

This study aims to evaluate, by micro-computed tomography, the filling capacity of two root canal dressings (RCD) - Bio-C Temp and Ultracal - after different activation protocols in teeth with simulated internal root resorption. Eighty single-rooted bovine teeth were sectioned in the cervical portion, standardizing the roots at 16 mm. Then, the canals were prepared by the apex-crown technique until instrument #80 using 2mL of 2.5% sodium hypochlorite solution at each instrument change. Afterward, the roots were sectioned longitudinally, and internal root resorptions were simulated using a diamond bur 1016 at 5 mm from the root apex. Hemiroots were joined and fixed with cyanoacrylate, scanned in micro-computed tomography (micro-CT) to assess total canal volume and simulated internal resorption, and then divided by stratified randomization into experimental groups according to RCD and method of activation (n = 10): Ultracal/Syringe; Ultracal/PUI, Ultracal/XP Endo Finisher, Ultracal Easy Clean, Bio-C Temp/Syringe, Bio-C Temp/PUI, Bio-C Temp/XP Endo Finisher and Bio-C/Easy Clean. Another scanning was performed to assess the volume of voids after RCD activation methods. The ANOVA and Tukey tests compared the activation methods. Student's T-test compared the RCDs within each activation method. Initial root canal volume values were similar for all groups (P > 0.05). There was no difference between activation protocols (P > 0.05). Higher volumes of void spaces were observed for Bio-C Temp compared to Ultracal after all activation methods (P < 0.05), except for Easy Clean (P > 0.05). Due to this, it can be concluded that the agitation methods tested for the Bio-C Temp and Ultracal pastes did not improve the filling of bovine teeth with simulated internal root resorption.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA