Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Adhes Dent ; 13(1): 55-9, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20157679

RESUMO

PURPOSE: To evaluate the bond strength of glass fiber posts to intraradicular dentin when cemented with self-etching and self-adhesive resin cements. MATERIALS AND METHODS: Forty-eight single-rooted human teeth were decoronated, endodontically treated, post-space prepared and divided into 8 groups (n = 6). The glass fiber posts used were: Exacto (EA) (Angelus) and everStick (ES) (StichTeck), which were cemented with two self-adhesive resin cements: BisCem (BIS) (Bisco) and Rely-X Unicem (UNI) (3M/ESPE), and two self-etching resin cements: Esthetic Cementing System NAC100 (NAC) (Kuraray) and Panavia-F (PAN) (Kuraray). Specimens were thermocycled between 5°C and 55 °C for 1000 cycles and stored in water at 37°C for 1 month. Four 1-mm-thick (in cross section) rods were obtained from the cervical region of the roots. Specimens were then subjected to microtensile testing in a special machine (BISCO; Schaumburg, IL, USA) or a crosshead speed of 0.5 mm/min. Microtensile bond strength (µTBS) data were analyzed with two-way ANOVA and Tukey's tests. RESULTS: Means (and SD) of µTBS (MPa) were: EA/PAN: 10.3 (4.1), EA/NAC: 14 (5.1) EA/BIS: 16.4 (4.8), EA/UNI: 19.8 (5.1), ES/PAN: 25.9 (6.1), ES/NAC: 29.1 (7), ES/BIS: 28.9 (6), ES/UNI: 30.5 (6.6). ANOVA indicated significant differences among the groups (p < 0.001). Mean µTBS values obtained with ES post were significantly higher than those obtained with EA (p < 0.001). For EA, Tukey's test indicated that higher µTBS means were obtained with the self-adhesive resin cements (BIS and UNI), which were statistically significantly different (p < 0.05) from values obtained with the self-etching resin cements (PAN and NAC). Different cements had no significant effects on the bond strength values of ES post (p > 0.05). µTBS values obtained with ES post were significantly higher than those obtained with EA post irrespective of the resin cement used. CONCLUSION: everStick posts resulted in the highest mean µTBS values with all cements. Self-adhesive cements performed well in terms of bond strength.


Assuntos
Condicionamento Ácido do Dente/métodos , Colagem Dentária , Técnica para Retentor Intrarradicular , Cimentos de Resina , Análise de Variância , Resinas Compostas , Análise do Estresse Dentário , Dentina , Vidro , Humanos , Teste de Materiais , Estatísticas não Paramétricas , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA