Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Cardiovasc Dev Dis ; 11(6)2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38921682

RESUMO

AIM: To assess the acute effect of empagliflozin versus dapagliflozin administration on flow-mediated vasodilation in patients with type 2 diabetes mellitus. DESIGN: A double-blind clinical trial, at the Experimental and Clinical Therapeutics Institute, University Health Sciences Center, at the Universidad de Guadalajara, in inpatients with T2D according to the 2023 ADA criteria. METHODS: Thirty patients (15 males and 15 females), aged between 35 and 65 years, were included in this study, according to the 2023 ADA criteria. The eligible patients were randomly assigned to three groups: empagliflozin 25 mg once daily, dapagliflozin 10 mg once daily, or placebo once daily. Anthropometric parameters were taken using validated techniques. FMD was measured using a high-resolution semiautomatic ultrasound UNEX-EF 38G (UNEX Co., Ltd., Nagoya, Japan). Arterial tension was determined with the OMRON electronic digital sphygmomanometer (HEM 907 XL, Kyoto, Japan). RESULTS: The group of patients who received empagliflozin had a significantly lower baseline flow-mediated dilation (FMD) compared to the group receiving dapagliflozin (p = 0.017); at the end of this study, the empagliflozin group achieved a comparable FMD to the dapagliflozin group (p = 0.88). CONCLUSION: After the treatment period, the empagliflozin and dapagliflozin groups achieved similar FMD, suggesting a class effect.

2.
PLoS One ; 18(3): e0282728, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36930649

RESUMO

INTRODUCTION: Cardiovascular disease is a major cause of death among people living with HIV (PLH). Non-treated PLH show increased levels of inflammation and biomarkers of vascular activation, and arterial stiffness as a prognostic cardiovascular disease risk factor. We investigated the effect of one year of ART on treatment-naïve HIV(+) individuals on arterial stiffness and inflammatory and vascular cytokines. METHODS: We cross-sectionally compared aortic stiffness via tonometry, inflammatory, and vascular serum cytokines on treatment-naïve (n = 20) and HIV (-) (n = 9) matched by age, sex, metabolic profile, and Framingham score. We subsequently followed young, treatment-naïve individuals after 1-year of ART and compared aortic stiffness, metabolic profile, and inflammatory and vascular serum biomarkers to baseline. Inflammatory biomarkers included: hs-CRP, D-Dimer, SAA, sCD163s, MCP-1, IL-8, IL-18, MRP8/14. Vascular cytokines included: myoglobin, NGAL, MPO, Cystatin C, ICAM-1, VCAM-1, and MMP9. RESULTS: Treatment-naïve individuals were 34.8 years old, mostly males (95%), and with high smoking prevalence (70%). Baseline T CD4+ was 512±324 cells/mcL. cfPWV was similar between HIV(-) and treatment-naïve (6.8 vs 7.3 m/s; p = 0.16) but significantly decreased after ART (-0.52 m/s; 95% CI -0.87 to -0.16; p0.006). Almost all the determined cytokines were significantly higher compared to controls, except for MCP-1, myoglobin, NGAL, cystatin C, and MMP-9. At follow-up, only total cholesterol and triglycerides increased and all inflammatory cytokines significantly decreased. Regarding vascular cytokines, MPO, ICAM-1, and VCAM-1 showed a reduction. D-Dimer tended to decrease (p = 0.06) and hs-CRP did not show a significant reduction (p = 0.17). CONCLUSION: One year of ART had a positive effect on reducing inflammatory and vascular cytokines and arterial stiffness.


Assuntos
Doenças Cardiovasculares , Infecções por HIV , Rigidez Vascular , Masculino , Humanos , Adulto , Feminino , Proteína C-Reativa/metabolismo , Estudos Prospectivos , Molécula 1 de Adesão Intercelular/metabolismo , Cistatina C/metabolismo , Citocinas/metabolismo , Molécula 1 de Adesão de Célula Vascular , Lipocalina-2/metabolismo , Mioglobina/metabolismo , Infecções por HIV/tratamento farmacológico , Biomarcadores , Metaboloma
3.
BMC Cardiovasc Disord ; 20(1): 440, 2020 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-33028211

RESUMO

BACKGROUND: Human immunodeficiency virus (HIV) infection is associated with a greater risk of cardiovascular disease (CVD). HIV infection causes a chronic inflammatory state and increases oxidative stress which can cause endothelial dysfunction and arterial stiffness. Aortic stiffness measured by carotid femoral-pulse wave velocity (cfPWV) and central hemodynamics are independent cardiovascular risk factors and have the prognostic ability for CVD. We assessed cfPWV and central hemodynamics in young individuals with recent HIV infection diagnosis and without antiretroviral therapy. We hypothesized that individuals living with HIV would present greater cfPWV and central hemodynamics (central systolic blood pressure and pulse pressure) compared to uninfected controls. METHODS: We recruited 51 treatment-naïve individuals living with HIV (HIV(+)) without previous CVD and 51 age- and sex-matched controls (HIV negative (-)). We evaluated traditional CVD risk factors including metabolic profile, blood pressure (BP), smoking, HIV viral load, and CD4+ T-cells count. Arterial stiffness and central hemodynamics were evaluated by cfPWV, central systolic BP, and central pulse pressure (cPP) via applanation tonometry. RESULTS: HIV(+) individuals presented a greater prevalence of smoking, reduced high-density lipoprotein cholesterol, and body mass index. 65.9% of HIV(+) individuals exhibited lymphocyte CD4+ T-cells count < 500 cells/µL. There was no difference in brachial or central BP between groups; however, HIV(+) individuals showed significantly lower cPP. We observed a greater cfPWV (mean difference = 0.5 m/s; p < 0.01) in HIV(+) compared to controls, even after adjusting for heart rate, mean arterial pressure and smoking. CONCLUSION: In the early stages of infection, non-treated HIV individuals present a greater prevalence of traditional CVD risk factors, arterial stiffness, and normal or in some cases central hemodynamics.


Assuntos
Doenças Cardiovasculares/epidemiologia , Infecções por HIV/epidemiologia , Hemodinâmica , Rigidez Vascular , Adulto , Pressão Sanguínea , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/fisiopatologia , Velocidade da Onda de Pulso Carótido-Femoral , Estudos de Casos e Controles , Estudos Transversais , Feminino , Infecções por HIV/diagnóstico , Fatores de Risco de Doenças Cardíacas , Humanos , Masculino , Manometria , México/epidemiologia , Prevalência , Medição de Risco , Adulto Jovem
4.
Int J Food Sci Nutr ; 70(8): 977-985, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31084381

RESUMO

Type 2 diabetes mellitus (T2DM) is associated with premature atherosclerosis and arterial stiffening due to the accumulation of advanced glycation end-products in vessel walls. Green tea polyphenols are considered cardio-protective substances. In this randomised double-blind placebo-controlled trial (NCT02627898), we evaluated the effect of Green tea extract on arterial stiffness parameters, lipids, body composition and sRAGE levels. Twenty normotensive patients with T2DM treated with the standard therapy and statins, mean age 53.2 ± 9.4 years and mean BMI 30.1 ± 4.5 kg/m2, were randomised to receive a daily dose of 400 mg of green tea extract (polyphenols ≥90%, EGCG ≥45%) or placebo for 12 weeks. Compared to placebo, administration of green tea extract decreased central augmentation index (-3.05 ± 10.8% vs. 6.7 ± 0.1%, p = .04). These findings suggest that green tea extract could be used as an adjunct to the standard therapy to improve arterial stiffness in T2DM.


Assuntos
Diabetes Mellitus Tipo 2/tratamento farmacológico , Metabolismo dos Lipídeos/efeitos dos fármacos , Extratos Vegetais/farmacologia , Chá/química , Rigidez Vascular/efeitos dos fármacos , Adulto , Alanina Transaminase/sangue , Aspartato Aminotransferases/sangue , Composição Corporal/efeitos dos fármacos , Índice de Massa Corporal , Colesterol/sangue , HDL-Colesterol/sangue , LDL-Colesterol/sangue , Creatinina/sangue , Diabetes Mellitus Tipo 2/sangue , Suplementos Nutricionais , Método Duplo-Cego , Feminino , Hemoglobinas Glicadas/metabolismo , Hemodinâmica/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Polifenóis/administração & dosagem , Receptor para Produtos Finais de Glicação Avançada/sangue , Proteínas S100/sangue , Triglicerídeos/sangue
5.
Front Med (Lausanne) ; 6: 341, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32118001

RESUMO

Introduction: Cardiovascular parameters disruption can be found in patients at early stages of rheumatoid arthritis (RA). The primary endpoint of this study was the reduction of arterial stiffness in RA patients without traditional cardiovascular risk factors or previous comorbidities, measured by cardio-ankle vascular index (CAVI) through the enalapril intervention. The secondary endpoints were the enalapril influence on carotid femoral pulse wave velocity (cfPWV), carotid intima media thickness (cIMT), carotid artery distensibility (cDistensibility), Young's incremental elastic modulus (Einc)]. Materials and Methods: Fifty-three patients were enrolled in a clinical, randomized, closed-label trial. The subjects were randomly assigned into two groups: One receiving 5 mg of enalapril (27) or placebo (26), both twice a day. The drug was acquired at Victory Enterprises®. The placebo was kindly provided by the Universidad de Guadalajara (UdeG), as well as the blinding into two groups: A and B. Enalapril and placebo were packed into bottles without labeling. Clinical assessment included a structured questionnaire to gather demographic and clinical variables as well as determination of CAVI, cfPWV, cIMT, carotid artery distensibility and Einc. The whole set of evaluations were analyzed at the baseline and at the end of 12 weeks of intervention. Results: The CAVI measurement at baseline was 7.1 ± 1.4 and increased up to 7.5 ± 1.2 at the end of 12 weeks. Meanwhile, the enalapril group was as follows: 7.4 ± 1.2 and at the of intervention, reduced to 7.1 ± 0.9. A reduction in delta CAVI of 0.21 in the enalapril intervention group was found. In contrast, an increase of 0.39 was observed in the placebo group. The delta CAVI reduction was not influenced by age or peripheral systolic blood pressure (pSBP). Discussion: Enalapril seems to be effective in CAVI reduction in RA patients. The effect of enalapril intervention on arterial stiffness translated to the clinical context might be interpreted as a reduction of 6.4 years of arterial aging. Trial Registration: The protocol was approved by the Institutional Review Board with the register CI-0117 from UdeG, and 0211/18 from Hospital Civil "Dr. Juan I. Menchaca", Secretaría de Salud Jalisco: DGSP/DDI/D.INV.28/18 and retrospectively registered at ClinicalTrials.gov Protocol Registration and Results System: NCT03667131.

7.
Rev Med Chil ; 146(2): 190-195, 2018 Feb.
Artigo em Espanhol | MEDLINE | ID: mdl-29999155

RESUMO

Background A correct blood pressure (BP) measurement is essential for the diagnosis and control of high BP. AIM: To evaluate the agreement and repeatability of BP measurements with the OMRON HEM-7320-LA device compared to a mercury sphygmomanometer. MATERIAL AND METHODS: A cross-sectional study comparing BP measurements made by two randomly selected trained nurses and an automatic oscillometric device. The mercurial sphygmomanometer was connected to the automated device via a "T" type connector and a dual-head stethoscope was used, allowing simultaneous measurements. The results were analyzed with one-factor analysis of variance, Bland-Altman's test, repeatability coefficient (RC), and intra-class correlation coefficient (ICC). RESULTS: Forty-nine participants aged 56 ± 19 years were included. Nineteen had hypertension (38%). We did not observe a significant difference in either systolic (SBP) or diastolic blood pressure (DBP) pressure measurements between the observers and the device. The mean difference was -0.09 mmHg (95% confidence intervals (CI)-0.9 to 0.7) for SBP and -0.9 mmHg (95% CI -1.7 to -0.13) for DBP. The RC for SBP (6.2, 5.2 and 5.8 mmHg) and DBP (4.7, 4.2 y 5.2 mmHg) was similar between the observers and the device. The ICC for SBP was 0.990 (95% CI 0.983 to 0.995, p < 0.01) and 0.986 (95% CI 0.977 to 0.991, p < 0.01) for DBP. CONCLUSIONS: There was a high level of agreement and similar measurement repeatability in the measurements performed by the automatic device and the mercurial sphygmomanometer. No differences in BP measurements were observed.


Assuntos
Determinação da Pressão Arterial/instrumentação , Monitores de Pressão Arterial , Hipertensão/diagnóstico , Determinação da Pressão Arterial/métodos , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
8.
Rev. méd. Chile ; 146(2): 190-195, feb. 2018. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-961377

RESUMO

Background A correct blood pressure (BP) measurement is essential for the diagnosis and control of high BP. Aim: To evaluate the agreement and repeatability of BP measurements with the OMRON HEM-7320-LA device compared to a mercury sphygmomanometer. Material and Methods: A cross-sectional study comparing BP measurements made by two randomly selected trained nurses and an automatic oscillometric device. The mercurial sphygmomanometer was connected to the automated device via a "T" type connector and a dual-head stethoscope was used, allowing simultaneous measurements. The results were analyzed with one-factor analysis of variance, Bland-Altman's test, repeatability coefficient (RC), and intra-class correlation coefficient (ICC). Results: Forty-nine participants aged 56 ± 19 years were included. Nineteen had hypertension (38%). We did not observe a significant difference in either systolic (SBP) or diastolic blood pressure (DBP) pressure measurements between the observers and the device. The mean difference was −0.09 mmHg (95% confidence intervals (CI)-0.9 to 0.7) for SBP and −0.9 mmHg (95% CI −1.7 to −0.13) for DBP. The RC for SBP (6.2, 5.2 and 5.8 mmHg) and DBP (4.7, 4.2 y 5.2 mmHg) was similar between the observers and the device. The ICC for SBP was 0.990 (95% CI 0.983 to 0.995, p < 0.01) and 0.986 (95% CI 0.977 to 0.991, p < 0.01) for DBP. Conclusions: There was a high level of agreement and similar measurement repeatability in the measurements performed by the automatic device and the mercurial sphygmomanometer. No differences in BP measurements were observed.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Determinação da Pressão Arterial/instrumentação , Monitores de Pressão Arterial , Hipertensão/diagnóstico , Determinação da Pressão Arterial/métodos , Estudos Transversais , Reprodutibilidade dos Testes
9.
Blood Press Monit ; 22(6): 375-378, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28945665

RESUMO

OBJECTIVE: The aim of this study was to determine the accuracy of the Omron HEM-7320-LA with Intelli Wrap technology cuff HEM-FL1 for self-measurement and clinic blood pressure (BP) measurement according to the European Society of Hypertension International Protocol revision 2010. PARTICIPANTS AND METHODS: The evaluation was performed in 39 individuals. The mean age of the participants was 47.9±14 years; systolic BP was 145.2±24.3 mmHg (range: 97-190), diastolic BP was 90.9±12.9 mmHg (range: 68-120), and arm circumference was 30.8±4 cm (range: 25-38.5). RESULTS: The device successfully fulfilled the established criteria of the validation protocol. The device overestimated systolic BP by 0.6±5.7 mmHg and diastolic BP by 2.2±5.1 mmHg. The specially designed cuff HEM-FL1 to cover a broad range of arm circumferences and self-placement fulfilled the requirements of the International Protocol.


Assuntos
Determinação da Pressão Arterial/instrumentação , Pressão Sanguínea , Esfigmomanômetros/normas , Adulto , Idoso , Instituições de Assistência Ambulatorial , Braço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Autocuidado/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA