Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 94(9)2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37732831

RESUMO

GOAL: The present study aimed to investigate the behavior of dynamic electrical impedance myography (dEIM) signals during a 100-s period of the dynamic contraction of Wistar rats' gastrocnemius evoked by electrical stimulation and to link the variations in bioimpedance with muscular energy systems. METHODS: Muscle contraction used 30% of the maximum muscular force and persisted for 100 s, along which dynamic bioimpedance signals were acquired. Based on the bioimpedance signals, two parameters, ΔZc and ΔZpc, were calculated to allow the analysis of their changes with the energy systems that supplied adenosine triphosphate (ATP) to the muscle. ΔZc indicated the variation of impedance of a twitch cycle compared to the values observed during the rest period preceding the cycle, and ΔZpc indicated slow bioimpedance variations compared to the values obtained during the rest period. RESULTS: The results indicated that ΔZc followed the force behavior, achieving a change rate of ∼14%. This parameter was associated with instantaneous impedance changes owing to the occurrence of each twitch. CONCLUSION: Although the findings of this study were linked to energy system processes, future studies are required for improving the understanding of the underlying mechanisms involved in dEIM. SIGNIFICANCE: The results contributed to understanding the relation of energy systems that supply ATP to the muscles with dEIM variations that occurred during muscle activity.


Assuntos
Trifosfato de Adenosina , Músculo Esquelético , Ratos , Animais , Impedância Elétrica , Ratos Wistar , Miografia
2.
Rev Sci Instrum ; 91(8): 084103, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32872900

RESUMO

Electrical impedance myography (EIM) is as an experimental technique that associates muscle impedance with muscular activity. Changes in muscle impedance during contraction occur mainly due to changes in the morphological and physiological characteristics of muscles that lead to different impeditivities in comparison with the resting condition. There is no consensus on the details of muscular impedance during muscle activity. EIM measurements on humans are also influenced by factors such as the electrode-skin interface, layers of skin and fat, and the connective tissue that can generate undesirable effects in the impedance signal. These effects can be avoided if EIM measurements are carried out directly on the muscle by using the models of animals. This study investigates changes in the EIM signal in the gastrocnemius muscles of Wistar rats during different levels of muscular contraction. In vivo experiments were conducted on 19 male rats. The muscle was exposed, fixed on a load cell, and electrically stimulated to evoke different levels of muscle contraction. Signals of the components of impedance were analyzed against the muscular force signal. The results show moderate correlations (p < 0.05) among the impedance-related parameters of resistance (r = -0.76), reactance (r = 0.57), and phase (r = 0.53). In addition to providing an experimental protocol for the invasive collection of data on electrical impedance to minimize problems associated with surface electrodes, this study shows that of the components of impedance, resistance is most affected by the intensity of muscular contractions and that morphological changes influence impedance mainly at low intensities.


Assuntos
Contração Muscular , Músculo Esquelético/fisiologia , Miografia/métodos , Animais , Fenômenos Biomecânicos , Impedância Elétrica , Estimulação Elétrica , Masculino , Miografia/instrumentação , Ratos , Ratos Wistar
3.
Rev Sci Instrum ; 88(4): 045105, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28456219

RESUMO

Lactate threshold (LT) is one of the physiological parameters usually used in rowing sport training prescription because it indicates the transitions from aerobic to anaerobic metabolism. Assessment of LT is classically based on a series of values of blood lactate concentrations obtained during progressive exercise tests and thus has an invasive aspect. The feasibility of noninvasive LT estimative through bioelectrical impedance spectroscopy (BIS) data collected in thigh muscles during rowing ergometer exercise tests was investigated. Nineteen professional rowers, age 19 (mean) ± 4.8 (standard deviation) yr, height 187.3 ± 6.6 cm, body mass 83 ± 7.7 kg, and training experience of 7 ± 4 yr, were evaluated in a rowing ergometer progressive test with paired measures of blood lactate concentration and BIS in thigh muscles. Bioelectrical impedance data were obtained by using a bipolar method of spectroscopy based on the current response to a voltage step. An electrical model was used to interpret BIS data and to derive parameters that were investigated to estimate LT noninvasively. From the serial blood lactate measurements, LT was also determined through Dmax method (LTDmax). The zero crossing of the second derivative of kinetic of the capacitance electrode (Ce), one of the BIS parameters, was used to estimate LT. The agreement between the LT estimates through BIS (LTBIS) and through Dmax method (LTDmax) was evaluated using Bland-Altman plots, leading to a mean difference between the estimates of just 0.07 W and a Pearson correlation coefficient r = 0.85. This result supports the utilization of the proposed method based on BIS parameters for estimating noninvasively the lactate threshold in rowing.


Assuntos
Impedância Elétrica , Ácido Láctico/metabolismo , Músculo Esquelético/metabolismo , Adolescente , Humanos , Masculino , Análise de Regressão , Esportes , Adulto Jovem
4.
Rev Sci Instrum ; 87(8): 084305, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27587136

RESUMO

This in vitro study evaluated the diagnostic performance of an alternative electric bioimpedance spectroscopy technique (BIS-STEP) detect questionable occlusal carious lesions. Six specialists carried out the visual (V), radiography (R), and combined (VR) exams of 57 sound or non-cavitated occlusal carious lesion teeth classifying the occlusal surfaces in sound surface (H), enamel caries (EC), and dentinal caries (DC). Measurements were based on the current response to a step voltage excitation (BIS-STEP). A fractional electrical model was used to predict the current response in the time domain and to estimate the model parameters: Rs and Rp (resistive parameters), and C and α (fractional parameters). Histological analysis showed caries prevalence of 33.3% being 15.8% hidden caries. Combined examination obtained the best traditional diagnostic results with specificity = 59.0%, sensitivity = 70.9%, and accuracy = 60.8%. There were statistically significant differences in bioimpedance parameters between the H and EC groups (p = 0.016) and between the H and DC groups (Rs, p = 0.006; Rp, p = 0.022, and α, p = 0.041). Using a suitable threshold for the Rs, we obtained specificity = 60.7%, sensitivity = 77.9%, accuracy = 73.2%, and 100% of detection for deep lesions. It can be concluded that BIS-STEP method could be an important tool to improve the detection and management of occlusal non-cavitated primary caries and pigmented sites.


Assuntos
Cárie Dentária , Espectroscopia Dielétrica/métodos , Impedância Elétrica , Modelos Teóricos , Dente , Adulto , Espectroscopia Dielétrica/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
Artigo em Inglês | MEDLINE | ID: mdl-19963476

RESUMO

The present study aimed to compare the estimates of body liquid volumes performed by two bioimpedance spectrometry techniques. One based on a step response technique (BIS-PEB) and second one based on multifrequency Xitron Hydra 4200 equipment (Xitron Technologies, San Diego, CA, USA). The convenience sample was initially composed of 422 students from a military parachuting course of the Brazilian Army. From such sample 42 male students were randomly selected to be evaluated during three weeks. The anthropometrical characteristics of the sample can be summarized as: 25.18 +/- 4.10 years old; weight equals of 76.77 +/- 7.84 kg; height equals to 174.96 +/- 5.67 cm; body mass index (BMI) equal to 25.05 +/- 2.11 kg m(-2). Bland-Altman graphics were used to compare the two methods in what concerns to estimate of extracellular fluid (ECF), intracellular fluid (ICF), and total body water (TBW). One can observe that the estimates of the two techniques present a good correlation, especially in the case of ECF (r = 0.975). The present study indicates that BIS-PEB technique associated with De Lorenzo equation can supply noninvasive estimates of body fluid volumes comparable to Xitron Hydra 4200 equipment.


Assuntos
Líquidos Corporais , Pletismografia de Impedância/métodos , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
6.
Artigo em Inglês | MEDLINE | ID: mdl-19163991

RESUMO

The aim of the present study was to derive an objective and noninvasive assessment of osteoarthritis of the knee joint by bioimpedance spectrocopy (BIS). The study was performed in Brazilian Military Parachuters and intends to contribute to the improvement of the early diagnosis of joint degeneration. Twelve male volunteers (24 knee joints) participated in the study. A novel index (ID) to assess the disease was proposed from the raw bioimpedance parameter. This index was compared with a subjective rating (Dejour scale) performed by 3 therapists. The results indicated that the values of ID were significantly different (p0.001) between the control group (class 1 of Dejour) and the pathological group (class 2 or higher). A Spearman correlation of -0.81 between the values of ID and the therapists rating was detected. Despite the need of increasing the sample size, the novel technique seems to be capable of supplying an objective and non-invasive tool for helping the diagnosis of the knee osteoarthritis.


Assuntos
Aviação , Diagnóstico por Computador/métodos , Militares , Doenças Profissionais/diagnóstico , Osteoartrite do Joelho/diagnóstico , Pletismografia de Impedância/métodos , Brasil , Humanos , Masculino , Doenças Profissionais/fisiopatologia , Osteoartrite do Joelho/fisiopatologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA