Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Reprod Biol Endocrinol ; 15(1): 96, 2017 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-29246176

RESUMO

BACKGROUND: Several studies have reported a correlation between antral follicle count by conventional 2D transvaginal sonography and serum anti-Müllerian hormone levels. However, few studies have investigated the effectiveness of 3D SonoAVC transvaginal ultrasound technology, particularly in infertile women. Therefore, this study aims to evaluate the usefulness of three-dimensional (3D) SonoAVC transvaginal ultrasound technology for antral follicle count and its correlation to conventional two-dimensional (2D) transvaginal ultrasound and serum levels of anti-Müllerian hormone in infertile women. METHODS: This cross-sectional study included 42 infertile women with age lower than 40 years that underwent treatment at a private fertility clinic between June and December 2015. Patient data included age, body mass index and cause of infertility. On cycle day 3 the following hormone levels were measured: serum levels of anti-Müllerian hormone, follicle-stimulating hormone, cancer antigen 125, prolactin, thyroid-stimulating hormone and oestradiol; the number of antral follicles was counted as well. The scanning were performed through 2D and 3D technology transvaginal ultrasound. RESULTS: Using a Bland-Altman test we demonstrated that both technologies are quite equivalent. However, antral follicle count is higher using 3D ultrasound technology compared to 2D technology (p < 0.001; Wilcoxon test), this finding is mainly remarkable in ovaries with more than 20 antral follicles. Moreover, the mean time required for manual 2D ultrasound and 3D SonoAVC measurements were 275 ± 109 and 103 ± 57 s, respectively (p < 0.001). Serum AMH concentration correlated to the total number of early antral follicles (correlation coefficients = 0.678 and 0.612; p < 0.001 by 2D ultrasound and 3D SonoAVC, respectively; Spearman's correlation test). CONCLUSIONS: Antral follicle count is better estimated using 3D ultrasound compared to 2D technology. A great advantage of 3D SonoAVC was less time required for an examination and the visual advantage when it need to count more than 20 follicles. TRIAL REGISTRATION: CAAE: 35141114.4.0000.5327 . Registered 10 June 2015.


Assuntos
Hormônio Antimülleriano/sangue , Imageamento Tridimensional/métodos , Infertilidade Feminina/diagnóstico por imagem , Folículo Ovariano/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Estudos Transversais , Estradiol/sangue , Feminino , Hormônio Foliculoestimulante/sangue , Humanos , Infertilidade Feminina/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA