RESUMO
Ventilator-associated pneumonia (VAP) is the most commonly-acquired infection in patients in intensive care units. We analyzed epidemiological and microbiological characteristics and the outcome, in a cohort of critically-ill patients with confirmed diagnosis of VAP. All patients who had been on mechanical ventilation (MV) for more than 48 hours were included in our study; material collection for microbiological analysis was done within the first 24 hours after beginning treatment or after changing antibiotics. There were 55/265 (20.7%) VAP cases diagnosed, at a rate of 21.6 episodes per 1,000 days of mechanical ventilation. Mean age of the patients was 66 years, with a mean APACHE II score of 26.7 + 7.0; male patients were more prevalent. The mortality rates in the intensive care unit (ICU) and during the hospital stay were 71% and 80%, respectively. MV duration in patients with VAP was 17 (range 3-43) days and among patients who had not developed VAP, 6 (2-32) days (p < 0.0001). 98.2% of the samples were positive, with a high prevalence of Gram-negative bacteria, mainly Acinetobacter calcoaceticus. Risk factors for death included age, MV duration and surgery. VAP incidence in this sample of critically-ill patients was high, with a high mortality rate. Control and prevention strategies based on continuing education of healthcare workers, developed by a multidisciplinary team, should be encouraged to minimize morbimortality of this infection.
Assuntos
Mortalidade Hospitalar , Pneumonia Associada à Ventilação Mecânica/mortalidade , APACHE , Idoso , Estudos de Coortes , Feminino , Hospitais de Ensino , Humanos , Incidência , Unidades de Terapia Intensiva , Tempo de Internação , Masculino , Pneumonia Associada à Ventilação Mecânica/microbiologia , Estudos Prospectivos , Fatores de TempoRESUMO
Ventilator-associated pneumonia (VAP) is the most commonly-acquired infection in patients in intensive care units. We analyzed epidemiological and microbiological characteristics and the outcome, in a cohort of critically-ill patients with confirmed diagnosis of VAP. All patients who had been on mechanical ventilation (MV) for more than 48 hours were included in our study; material collection for microbiological analysis was done within the first 24 hours after beginning treatment or after changing antibiotics. There were 55/265 (20.7 percent) VAP cases diagnosed, at a rate of 21.6 episodes per 1,000 days of mechanical ventilation. Mean age of the patients was 66 years, with a mean APACHE II score of 26.7 + 7.0; male patients were more prevalent. The mortality rates in the intensive care unit (ICU) and during the hospital stay were 71 percent and 80 percent, respectively. MV duration in patients with VAP was 17 (range 3-43) days and among patients who had not developed VAP, 6 (2-32) days (p < 0.0001). 98.2 percent of the samples were positive, with a high prevalence of Gram-negative bacteria, mainly Acinetobacter calcoaceticus. Risk factors for death included age, MV duration and surgery. VAP incidence in this sample of critically-ill patients was high, with a high mortality rate. Control and prevention strategies based on continuing education of healthcare workers, developed by a multidisciplinary team, should be encouraged to minimize morbimortality of this infection.
Assuntos
Idoso , Feminino , Humanos , Masculino , Mortalidade Hospitalar , Pneumonia Associada à Ventilação Mecânica/mortalidade , APACHE , Estudos de Coortes , Hospitais de Ensino , Incidência , Unidades de Terapia Intensiva , Tempo de Internação , Estudos Prospectivos , Pneumonia Associada à Ventilação Mecânica/microbiologia , Fatores de TempoRESUMO
JUSTIFICATIVA E OBJETIVOS: A monitorização de funções vitais é uma das mais importantes e essenciais ferramentas no manuseio de pacientes críticos na UTI. Hoje é possível detectar e analisar uma grande variedade de sinais fisiológicos através de diferentes técnicas, invasivas e não-invasivas. O intensivista deve ser capaz de selecionar e executar o método de monitorização mais apropriado de acordo com as necessidades individuais do paciente, considerando a relação risco-benefício da técnica. Apesar do rápido desenvolvimento de técnicas de monitorização não-invasiva, a monitorização hemodinâmica invasiva com o uso do cateter de artéria pulmonar (CAP) ainda é um dos procedimentos fundamentais em UTI. O objetivo destas recomendações é estabelecer diretrizes para o uso adequado dos métodos básicos de monitorização hemodinâmica e CAP. MÉTODO: O processo de desenvolvimento de recomendações utilizou o método Delphi modificado para criar e quantificar o consenso entre os participantes. A AMIB determinou um coordenador para o consenso, o qual escolheu seis especialistas para comporem o comitê consultivo. Outros 18 peritos de diferentes regiões do país foram selecionados para completar o painel de 25 especialistas, médicos e enfermeiros. Um levantamento bibliográfico na MedLine de artigos na língua inglesa foi realizado no período de 1966 a 2004. RESULTADOS: Foram apresentadas recomendações referentes a 55 questões sobre monitorização da pressão venosa central, pressão arterial invasiva e cateter de artéria pulmonar. Com relação ao CAP, além de recomendações quanto ao uso correto foram discutidas as indicações em diferentes situações clínicas. CONCLUSÕES: A avaliação da pressão venosa central e da pressão arterial, além das variáveis obtidas com o CAP permite o entendimento da fisiologia indispensável para o cuidado de pacientes graves. Entretanto, a correta utilização dessas ferramentas é fundamental para os possíveis benefícios decorrentes do uso.
BACKGROUND AND OBJECTIVES: Monitoring of vital functions is one of the most important tools in the management of critically ill patients. Nowadays is possible to detect and analyze a great deal of physiologic data using a lot of invasive and non-invasive methods. The intensivist must be able to select and carry out the most appropriate monitoring technique according to the patient requirements and taking into account the benefit/risk ratio. Despite the fast development of non invasive monitoring techniques, invasive hemodynamic monitoring using Pulmonary Artery Catheter still is one of the basic procedures in Critical Care. The aim was to define recommendations about clinical utility of basic hemodynamic monitoring methods and the Use of Pulmonary Artery Catheter. METHODS: Modified Delphi methodology was used to create and quantify the consensus between the participants. AMIB indicated a coordinator who invited more six experts in the area of monitoring and hemodynamic support to constitute the Consensus Advisory Board. Twenty-five physicians and nurses selected from different regions of the country completed the expert panel, which reviewed the pertinent bibliography listed at the MEDLINE in the period from 1996 to 2004. RESULTS: Recommendations were made based on 55 questions about the use of central venous pressure, invasive arterial pressure, pulmonary artery catheter and its indications in different settings. CONCLUSIONS: Evaluation of central venous pressure and invasive arterial pressure, besides variables obtained by the PAC allow the understanding of cardiovascular physiology that is of great value to the care of critically ill patients. However, the correct use of these tools is fundamental to achieve the benefits due to its use.
Assuntos
Unidades de Terapia Intensiva , Monitoramento AmbientalRESUMO
JUSTIFICATIVA E OBJETIVOS: A interpretação do débito cardíaco e da pré-carga como números absolutos não traz grandes informações sobre a hemodinâmica do paciente crítico. Em contrapartida, a monitorização da resposta do débito cardíaco à expansão volêmica ou suporte inotrópico é uma ferramenta muito útil na unidade de terapia intensiva, quando o paciente apresenta algum sinal de má perfusão tecidual. Apesar do CAP ser considerado como " padrão-ouro" na avaliação destes parâmetros, foram desenvolvidas tecnologias alternativas bastante confiáveis para a sua monitorização. MÉTODO: O processo de desenvolvimento de recomendações utilizou o método Delphi modificado para criar e quantificar o consenso entre os participantes. A AMIB determinou um coordenador para o consenso, o qual escolheu seis especialistas para comporem o comitê consultivo. Outros 18 peritos de diferentes regiões do país foram selecionados para completar o painel de 25 especialistas, médicos e enfermeiros. Um levantamento bibliográfico na MEDLINE de artigos na língua inglesa foi realizado no período de 1966 a 2004. RESULTADOS: Foram apresentadas recomendações referentes à análise da variação da pressão arterial durante ventilação mecânica, débito cardíaco contínuo por contorno de pulso arterial, débito cardíaco por diluição do lítio, Doppler transesofágico, bioimpedância transtorácica, ecocardiografia e reinalação parcial de gás carbônico. CONCLUSÕES: As novas e menos invasivas técnicas para medida do débito cardíaco, pré-carga e fluidoresponsividade apresentam adequada precisão e podem ser uma alternativa ao uso do CAP em pacientes graves.
BACKGROUND AND OBJECTIVES: Cardiac output and preload as absolute data do not offer helpful information about the hemodynamic of critically ill patients. However, monitoring the response of these variables to volume challenge or inotropic drugs is a very useful tool in the critical care setting, particularly for patients with signs of tissue hypoperfusion. Although PAC remains the " gold standard" to measure cardiac output and preload, new and alternative technologies were developed to evaluate these hemodynamic variables. METHODS: Modified Delphi methodology was used to create and quantify the consensus between the participants. AMIB indicated a coordinator who invited more six experts in the area of monitoring and hemodynamic support to constitute the Consensus Advisory Board. Twenty three physician and two nurses selected from different regions of the country completed the expert panel, which reviewed the pertinent bibliography listed at the MEDLINE in the period from 1996 to 2004. RESULTS: Recommendations regarding the use of arterial pulse pressure variation during mechanical ventilation, continuous arterial pulse contour and lithium dilution cardiac output measurements, esophageal Doppler waveform, thoracic electrical bioimpedance, echocardiography and partial CO2 rebreathing for monitoring cardiac output and preload were created. CONCLUSIONS: The new and less invasive techniques for the measurement of cardiac output, preload or fluid responsiveness are accurate and may be an alternative to PAC in critically ill patients.
Assuntos
Unidades de Terapia Intensiva , Monitoramento AmbientalRESUMO
BACKGROUND AND OBJECTIVES: Monitoring of vital functions is one of the most important tools in the management of critically ill patients. Nowadays is possible to detect and analyze a great deal of physiologic data using a lot of invasive and non-invasive methods. The intensivist must be able to select and carry out the most appropriate monitoring technique according to the patient requirements and taking into account the benefit/risk ratio. Despite the fast development of non invasive monitoring techniques, invasive hemodynamic monitoring using Pulmonary Artery Catheter still is one of the basic procedures in Critical Care. The aim was to define recommendations about clinical utility of basic hemodynamic monitoring methods and the Use of Pulmonary Artery Catheter. METHODS: Modified Delphi methodology was used to create and quantify the consensus between the participants. AMIB indicated a coordinator who invited more six experts in the area of monitoring and hemodynamic support to constitute the Consensus Advisory Board. Twenty-five physicians and nurses selected from different regions of the country completed the expert panel, which reviewed the pertinent bibliography listed at the MEDLINE in the period from 1996 to 2004. RESULTS: Recommendations were made based on 55 questions about the use of central venous pressure, invasive arterial pressure, pulmonary artery catheter and its indications in different settings. CONCLUSIONS: Evaluation of central venous pressure and invasive arterial pressure, besides variables obtained by the PAC allow the understanding of cardiovascular physiology that is of great value to the care of critically ill patients. However, the correct use of these tools is fundamental to achieve the benefits due to its use.
RESUMO
BACKGROUND AND OBJECTIVES: Cardiac output and preload as absolute data do not offer helpful information about the hemodynamic of critically ill patients. However, monitoring the response of these variables to volume challenge or inotropic drugs is a very useful tool in the critical care setting, particularly for patients with signs of tissue hypoperfusion. Although PAC remains the " gold standard" to measure cardiac output and preload, new and alternative technologies were developed to evaluate these hemodynamic variables. METHODS: Modified Delphi methodology was used to create and quantify the consensus between the participants. AMIB indicated a coordinator who invited more six experts in the area of monitoring and hemodynamic support to constitute the Consensus Advisory Board. Twenty three physician and two nurses selected from different regions of the country completed the expert panel, which reviewed the pertinent bibliography listed at the MEDLINE in the period from 1996 to 2004. RESULTS: Recommendations regarding the use of arterial pulse pressure variation during mechanical ventilation, continuous arterial pulse contour and lithium dilution cardiac output measurements, esophageal Doppler waveform, thoracic electrical bioimpedance, echocardiography and partial CO2 rebreathing for monitoring cardiac output and preload were created. CONCLUSIONS: The new and less invasive techniques for the measurement of cardiac output, preload or fluid responsiveness are accurate and may be an alternative to PAC in critically ill patients.