Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 101
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Acta sci. vet. (Online) ; 50: Pub. 1851, Jan. 19, 2022. ilus, graf
Artigo em Inglês | VETINDEX | ID: vti-765215

RESUMO

Background: Orthopedic implants are commonly used for different types of surgical procedures to gain optimal functionand to provide stability to both bones and tendon structures. When inserting these implants, the characteristics of the material are important for surgical success, and the ideal implant must be biocompatible and nonallergenic. However, whenmolding an implant to the bone structure, its resistance can change significantly. Implants can be temporary or permanentin the body, and metal possesses properties that make it acceptable for bone repair. In biomedical implants, 2 types aremost common, commercially pure (CP)-Ti and Ti-6A1-4V. They both provide stable fixation and low risk of loosening.Implants made with the same material and composition can perform differently if the material has been altered by processing techniques for different scenarios. Stress, strain and elastic modulus are the primary metrics used in the description ofimplant materials. They can be calculated based on mechanical tests of specimens with defined geometry, most commonlytensile, bending and torsional tests. In order to better evaluate those changes, we compared the mechanical characteristicsof titanium bone plates, before and after they were molded to the bone, to verify and quantify the loss of stiffness andresistance after molding the plate.Materials, Methods & Results: The study was prospective. Orthopedic implant made of commercially pure titanium (CPTi) were divided into 2 groups, one group without plate molding and the other with plate molding to a dog femora bone.Thirty-six plates of different sizes (5.0, 6.5, 8.0, 9.0, 10.0- and 11.0-mm diameter) were divided into 6 groups containing6 plates of each size and submitted to the 4-point flexion test of resistance, using a piece of dog femur (weights of 5, 10,15, 20 and 25 kg) as the bone in which the...(AU)


Assuntos
Animais , Cães , Titânio/análise , Placas Ósseas/veterinária , Materiais Biocompatíveis , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/veterinária , Próteses e Implantes/veterinária
2.
Acta sci. vet. (Impr.) ; 50: Pub.1851-2022. ilus, graf
Artigo em Inglês | VETINDEX | ID: biblio-1458526

RESUMO

Background: Orthopedic implants are commonly used for different types of surgical procedures to gain optimal functionand to provide stability to both bones and tendon structures. When inserting these implants, the characteristics of the material are important for surgical success, and the ideal implant must be biocompatible and nonallergenic. However, whenmolding an implant to the bone structure, its resistance can change significantly. Implants can be temporary or permanentin the body, and metal possesses properties that make it acceptable for bone repair. In biomedical implants, 2 types aremost common, commercially pure (CP)-Ti and Ti-6A1-4V. They both provide stable fixation and low risk of loosening.Implants made with the same material and composition can perform differently if the material has been altered by processing techniques for different scenarios. Stress, strain and elastic modulus are the primary metrics used in the description ofimplant materials. They can be calculated based on mechanical tests of specimens with defined geometry, most commonlytensile, bending and torsional tests. In order to better evaluate those changes, we compared the mechanical characteristicsof titanium bone plates, before and after they were molded to the bone, to verify and quantify the loss of stiffness andresistance after molding the plate.Materials, Methods & Results: The study was prospective. Orthopedic implant made of commercially pure titanium (CPTi) were divided into 2 groups, one group without plate molding and the other with plate molding to a dog femora bone.Thirty-six plates of different sizes (5.0, 6.5, 8.0, 9.0, 10.0- and 11.0-mm diameter) were divided into 6 groups containing6 plates of each size and submitted to the 4-point flexion test of resistance, using a piece of dog femur (weights of 5, 10,15, 20 and 25 kg) as the bone in which the...


Assuntos
Animais , Cães , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/veterinária , Materiais Biocompatíveis , Placas Ósseas/veterinária , Titânio/análise , Próteses e Implantes/veterinária
3.
Acta sci. vet. (Online) ; 49: Pub. 1791, Mar. 8, 2021. tab
Artigo em Inglês | VETINDEX | ID: vti-761942

RESUMO

Background: Extraluminal surgical procedures for intrathoracic tracheal collapse in dogs are not routinely performed. The patients are normally treated with different drugs or by intraluminal stents. However, in more severe cases, drug treatment does not always have good outcomes, and intraluminal prostheses can be correlated to several postoperative problems. In order to obtain better results, we aimed to develop a surgical technique for implantation of a new extraluminal helical prosthesis in the thoracic segment of the trachea through cervical access, associated with pneumatic mediastinoscopy for certification of the technique and minimization of possible complications. Materials, Methods & Results: Seven canine corpses (CCs) from non-traumatic death, weighing between 2 and 7 kg, were used. A ventral cervical approach to the trachea was associated with blunt mediastinal dissection. Trans cervical pneumatic mediastinoscopy was used for evaluation of the dissection and location of the implant. These were compared with the necropsy findings by the exact Wilcoxon two-sample test, with P < 0.05. The results of necropsy and mediastinoscopy did not present significant differences at P < 0.05. During the examinations, the presence of some mediastinal visceral le-sions caused by the prosthesis, the integrity of the mediastinum and possible lesions to RLN and blood vessels (BV) were analyzed. We also investigated the location of the distal part of the prosthesis in the thoracic segment of the trachea and its dissection. To evaluate the technique, statistical comparison was made between mediastinoscopy and necropsy find-ings. The data were compared by the Wilcoxon test at 5% probability. The tracheas of all CCs were efficiently dissected, but in some cases problems that can happen during the procedure were noticed. This was checked by mediastinoscopy and confirmed by necropsy. The median of the scores was...(AU)


Assuntos
Animais , Cães , Cães/cirurgia , Traqueia/cirurgia , Stents/veterinária , Procedimentos Cirúrgicos Operatórios/veterinária
4.
Acta sci. vet. (Impr.) ; 49(supl.1): Pub. 678, 2021. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1363014

RESUMO

Background: Pulmonary neoplasia is an abnormal proliferation of cells at the lung tissue, and may be classified as primary, secondary or metastatic, and multisystemic. However, primary neoplasia is rare in canids. Additionally, neoplasms may be classified according to their biological behavior as either malignant or benign. Malignant tumors are more prevalent. The diagnosis can be difficult due to nonspecific symptoms, taking into account that some affected patients do not have symptoms at all; thus, the real incidence of the disease might remain undiagnosed on certain occasions. Therefore, we aimed to report an unprecedented successful case of lung lobectomy surgery in dogs with the aid of infrared video thermometry, which showed real-time images during the surgical procedure. Case: A 10-year-old male dog, crossbreed with Cocker Spaniel, was attended with a history of lethargy, dullness, progressive weight loss, cough, and difficulty breathing. Due to the chronic severity of the clinical signs and the normal physiological clinical examination, complementary exams were requested, such as radiography of the cervical and thoracic regions, cranial and thoracoabdominal computed tomography (TCT). The results of the exams showed the presence of a nodule mass in the right caudal pulmonary lobe which caused a lateral deviation to the left hemithorax of the cardiac silhouette. The patient underwent a surgical procedure with an approach through the thoracic region, at the height of the seventh intercostal space, and a total lobectomy was performed. Throughout the surgical procedure, video thermometry in real-time through the MART station (Metabolic Activity in Real-Time FLIR SC325®) was used to determine the viability of adjacent tissues through temperature differences measured in degrees Celsius. The surgical fragment containing the direct caudal pulmonary lobe and the mass were sent to the pathology sector for anatomopathological evaluation. An abundant papillary epithelial proliferation was visualized through microscopy, presenting areas of necrosis and inflammatory polymorphonuclear infiltrate. The nodule was diagnosed as lung papillary adenocarcinoma. Discussion: Adenocarcinomas consist of papillary, acinar, solid, or mixed glandular structures. They may originate from the airways, bronchial glands, or bronchoalveolar region, and often show invasive growth presenting a rudimentary and irregular shape. The clinical signs are non-specific, including exercise intolerance, non-productive cough, chronic respiratory signs such as tachypnoea or dyspnea, reduced appetite, weight loss, lethargy, chest palpation pain, hemothorax, pneumothorax, and pleural effusion. The diagnosis is concluded through imaging diagnostic tests, of which chest radiography is the most important, followed by magnetic resonance and computed tomography. Also, histopathological examination is essential to determine a definitive diagnosis. The treatment of choice for adenocarcinoma nodules is a surgical excision of the tumor mass. However, the type of surgical approach is determined by different factors such as size, location, and involvement of adjacent structures. The ablation of pulmonary masses may be performed either via partial or total lobectomies. Nevertheless, partial lobectomy is more often performed on non-neoplastic masses or to obtain material for biopsy, whilst total lobectomy is recommended for a malignant neoplasm removal. The prognosis is always guarded, having a more favorable outcome in masses of the smaller diameter without the involvement of adjacent structures.(AU)


Assuntos
Animais , Masculino , Cães , Termografia/veterinária , Adenocarcinoma de Pulmão/cirurgia , Adenocarcinoma de Pulmão/veterinária , Adenocarcinoma de Pulmão/diagnóstico por imagem , Cirurgia Vídeoassistida/métodos
5.
Acta sci. vet. (Impr.) ; 49: Pub.1791-2021. tab
Artigo em Inglês | VETINDEX | ID: biblio-1458430

RESUMO

Background: Extraluminal surgical procedures for intrathoracic tracheal collapse in dogs are not routinely performed. The patients are normally treated with different drugs or by intraluminal stents. However, in more severe cases, drug treatment does not always have good outcomes, and intraluminal prostheses can be correlated to several postoperative problems. In order to obtain better results, we aimed to develop a surgical technique for implantation of a new extraluminal helical prosthesis in the thoracic segment of the trachea through cervical access, associated with pneumatic mediastinoscopy for certification of the technique and minimization of possible complications. Materials, Methods & Results: Seven canine corpses (CCs) from non-traumatic death, weighing between 2 and 7 kg, were used. A ventral cervical approach to the trachea was associated with blunt mediastinal dissection. Trans cervical pneumatic mediastinoscopy was used for evaluation of the dissection and location of the implant. These were compared with the necropsy findings by the exact Wilcoxon two-sample test, with P < 0.05. The results of necropsy and mediastinoscopy did not present significant differences at P < 0.05. During the examinations, the presence of some mediastinal visceral le-sions caused by the prosthesis, the integrity of the mediastinum and possible lesions to RLN and blood vessels (BV) were analyzed. We also investigated the location of the distal part of the prosthesis in the thoracic segment of the trachea and its dissection. To evaluate the technique, statistical comparison was made between mediastinoscopy and necropsy find-ings. The data were compared by the Wilcoxon test at 5% probability. The tracheas of all CCs were efficiently dissected, but in some cases problems that can happen during the procedure were noticed. This was checked by mediastinoscopy and confirmed by necropsy. The median of the scores was...


Assuntos
Animais , Cães , Cães/cirurgia , Stents/veterinária , Traqueia/cirurgia , Procedimentos Cirúrgicos Operatórios/veterinária
6.
Cell Physiol Biochem ; 52(5): 1166-1177, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30990586

RESUMO

BACKGROUND/AIMS: Tributyltin (TBT) is an organotin (OTs) and biohazard organometallic pollutant. Recently our group has shown that TBT, even in very low doses, has deleterious effects on several tissues most likely due to its role as an endocrine-disrupting molecule. Other studies have confirmed that OT exposure could be responsible for neural, endocrine, and reproductive dysfunctions via in vitro and in vivo models. However, TBT effects on bone lack concise data despite the fact that bone turnover is regulated by endocrine molecules, such as parathormone (PTH), estrogen (E2), etc. Our group has already shown that TBT disrupts adrenal and female gonadal functions. METHODS: We studied the effects of TBT on bone metabolism and structure using DXA, microCT scan, and SEM. We also determined the calcium (Ca²âº) and phosphate (Pi) metabolism in TBT-treated rats as well as some biomarkers for bone formation and resorption. RESULTS: Surprisingly, we found that TBT leads to higher bone mineral density (BMD) although lesions in spinal bone were observed by either microCT scan or SEM. Biomarkers for bone resorption, such as the urinary deoxipyridinolines (DPD) excretion ratio was increased in TBT-treated animals versus mock-treated controls. Osteocalcin (OC) and alkaline phosphatase (AP) are markers of bone formation and are also elevated suggesting that the bone matrix suffers from a higher turnover. Serum Ca²âº (total and ionized) do not changed by TBT treatment although hypercalciuria is observed. CONCLUSION: It is known that Sn atoms have three valence states (Sn²âº, Sn³âº, and Sn4⁺); hence, we hypothesized that Sn (more likely Sn²âº) could be competing with Ca²âº and/or Mg²âº in hydroxyapatite mineral matrix to disturb bone turnover. Further work is needed to confirm this hypothesis.


Assuntos
Densidade Óssea/efeitos dos fármacos , Reabsorção Óssea , Disruptores Endócrinos/toxicidade , Hipercalciúria , Osteogênese/efeitos dos fármacos , Compostos de Trialquitina/toxicidade , Animais , Reabsorção Óssea/induzido quimicamente , Reabsorção Óssea/diagnóstico por imagem , Reabsorção Óssea/metabolismo , Feminino , Hipercalciúria/induzido quimicamente , Hipercalciúria/diagnóstico por imagem , Hipercalciúria/metabolismo , Ratos , Ratos Wistar , Microtomografia por Raio-X
7.
Acta Cir Bras ; 34(3): e201900302, 2019 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-30916139

RESUMO

PURPOSE: To evaluate, in rats, the open field videothermometry in real time while performing left pneumonectomy for early diagnosis of cardiopulmonary changes. METHODS: Twelve non-specific pathogen-free Wistar rats were randomly allocated into two groups; pneumectomy group (GP) and sham surgery group (GS). Mean arterial pressure, videothermometry in real time, of the right lung, and histopathological analysis of the remaining lung were evaluated in all animals. RESULTS: Videothermometry in real time allowed identification of temperature variance of right lung after pneumectomy, indicating a significant decrease in temperature during evaluation. There was a statistical difference between M0 and M1, M1 and M2 and M0 and M2 (p<0.004) in GS, and significant difference between M0 and M1, M1 and M2, and M2 and M0 with p<0.0001 in GP. CONCLUSIONS: Left pneumonectomy in rats shows initial histopathological changes after 60 minutes of its completion, indicating a possible compensation beginning. The open-field videothermometry in real time proved to be efficient identifying the temperature changes of the remaining lung.


Assuntos
Temperatura Corporal/fisiologia , Pulmão/metabolismo , Pneumonectomia/métodos , Termometria/métodos , Animais , Pressão Arterial/fisiologia , Pulmão/patologia , Pulmão/fisiopatologia , Distribuição Aleatória , Ratos Wistar , Reprodutibilidade dos Testes , Fatores de Tempo
8.
Acta cir. bras. ; 34(3): e201900302, Mar. 21, 2019. ilus, tab, graf
Artigo em Inglês | VETINDEX | ID: vti-20873

RESUMO

Purpose:To evaluate, in rats, the open field videothermometry in real time while performing left pneumonectomy for early diagnosis of cardiopulmonary changes.Methods:Twelve non-specific pathogen-free Wistar rats were randomly allocated into two groups; pneumectomy group (GP) and sham surgery group (GS). Mean arterial pressure, videothermometry in real time, of the right lung, and histopathological analysis of the remaining lung were evaluated in all animals.Results:Videothermometry in real time allowed identification of temperature variance of right lung after pneumectomy, indicating a significant decrease in temperature during evaluation. There was a statistical difference between M0 and M1, M1 and M2 and M0 and M2 (p<0.004) in GS, and significant difference between M0 and M1, M1 and M2, and M2 and M0 with p<0.0001 in GP.Conclusions:Left pneumonectomy in rats shows initial histopathological changes after 60 minutes of its completion, indicating a possible compensation beginning. The open-field videothermometry in real time proved to be efficient identifying the temperature changes of the remaining lung.(AU)


Assuntos
Animais , Ratos , Termometria/métodos , Termometria/veterinária , Metabolismo/fisiologia , Ratos Wistar , Pneumonectomia/veterinária
9.
Acta cir. bras ; Acta cir. bras;34(3): e201900302, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-989067

RESUMO

Abstract Purpose: To evaluate, in rats, the open field videothermometry in real time while performing left pneumonectomy for early diagnosis of cardiopulmonary changes. Methods: Twelve non-specific pathogen-free Wistar rats were randomly allocated into two groups; pneumectomy group (GP) and sham surgery group (GS). Mean arterial pressure, videothermometry in real time, of the right lung, and histopathological analysis of the remaining lung were evaluated in all animals. Results: Videothermometry in real time allowed identification of temperature variance of right lung after pneumectomy, indicating a significant decrease in temperature during evaluation. There was a statistical difference between M0 and M1, M1 and M2 and M0 and M2 (p<0.004) in GS, and significant difference between M0 and M1, M1 and M2, and M2 and M0 with p<0.0001 in GP. Conclusions: Left pneumonectomy in rats shows initial histopathological changes after 60 minutes of its completion, indicating a possible compensation beginning. The open-field videothermometry in real time proved to be efficient identifying the temperature changes of the remaining lung.


Assuntos
Animais , Pneumonectomia/métodos , Temperatura Corporal/fisiologia , Termometria/métodos , Pulmão/metabolismo , Fatores de Tempo , Distribuição Aleatória , Reprodutibilidade dos Testes , Ratos Wistar , Pressão Arterial/fisiologia , Pulmão/fisiopatologia , Pulmão/patologia
10.
Cell Physiol Biochem ; 51(1): 356-374, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30453296

RESUMO

BACKGROUND/AIMS: Osteoporosis is a bone metabolic disease that affects mostly post-menopausal women. There has been shown that vitamin K (VK) supplementation during menopause may decrease bone loss as well as risk of bone breaking. Aiming to clarify the beneficial role of VK in bone metabolism during menopause, we investigated mineral metabolism and bone ultrastructure of ovariectomized (OVX) mice. METHODS: To determine the effects chronic use of VK in bone structure and mineral metabolism in OVX mice, we used several methods, such as DXA, µCTScan, and SEM as well as biomolecular techniques, such as ELISA and qRT-PCR. In addition, complete analysis of serum hormonal and other molecules associated to bone and lipid metabolism were evaluated overview the effects of VK in menopause murine model. RESULTS: VK treatment significantly affects Pi metabolism independently of OVX, changing Pi plasma, urinary output, balance, and Pi bone mass. Interestingly, VK also increased VLDL in mice independently of castration. In addition, VK increased compact bone mass in OVX mice when we evaluated it by DXA, histomorphometry, µCTScanning. VK increased bone formation markers, osteocalcin, HYP- osteocalcin, and AP whereas it decreased bone resorption markers, such as urinary DPD/creatinine ratio and plasmatic TRAP. Surprisingly, SEM images revealed that VK treatment led to amelioration of microfractures observed in OVX untreated controls. In addition, SHAM operated VK treated mice exhibited higher number of migrating osteoblasts and in situ secretion of AP. OVX led to decreased to in situ secretion of AP that was restored by VK treatment. Moreover, VK treatment increased mRNA expression of bone Calbindin 28KDa independently of OVX. CONCLUSION: VK treatment in OVX mice exhibited beneficial effects on bone ultrastructure, mostly by altering osteoblastic function and secretion of organic bone matrix. Therefore, VK could be useful to treat osteopenic/osteoporotic patients.


Assuntos
Densidade Óssea/efeitos dos fármacos , Osso e Ossos/metabolismo , Vitamina K/farmacologia , Fosfatase Alcalina/sangue , Animais , Osso e Ossos/diagnóstico por imagem , Osso e Ossos/ultraestrutura , Calbindinas/genética , Calbindinas/metabolismo , Creatinina/urina , Suplementos Nutricionais , Modelos Animais de Doenças , Feminino , Metabolismo dos Lipídeos , Camundongos , Camundongos Endogâmicos C57BL , Microscopia Eletrônica de Varredura , Osteocalcina/sangue , Osteoporose/metabolismo , Osteoporose/patologia , Ovariectomia , Hormônio Paratireóideo/sangue , Coluna Vertebral/diagnóstico por imagem , Microtomografia por Raio-X
11.
Acta Cir Bras ; 33(4): 386-395, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29768541

RESUMO

PURPOSE: To investigate the safety and clinical, hemodynamic and tissue improvement ability in mini pigs undergoing cell and gene therapy for the treatment of acute myocardial infarction. METHODS: Thirty-two mini pigs Br1 lineage, 12 months old, undergoing induction of acute myocardial infarction by occlusion of the diagonal branch of the paraconal coronary. They were divided into 4 groups: one control group and 3 treatment groups (cell therapy and gene cell therapy). Echocardiography reviews were performed on three occasions and histopathological analysis was performed after 4 weeks. Analysis of variance (ANOVA), Tukey and Wilcoxon tests, were performed. RESULTS: Association of vascular endothelial growth factor (VEGF) with angiopoietin1 (Ang1) presented satisfactory results in the improvement of ventricular function following ischemic cardiomyopathy in mini pigs when compared to the results of the other treated groups. CONCLUSION: The therapy with VEGF and the combination of VEGF with Ang1, promoted recovered function of the myocardium, characterized by reduced akinetic area and induction of neovascularization.


Assuntos
Angiopoietina-1/uso terapêutico , Terapia Baseada em Transplante de Células e Tecidos/métodos , Terapia Genética/métodos , Infarto do Miocárdio/terapia , Fator A de Crescimento do Endotélio Vascular/uso terapêutico , Função Ventricular/fisiologia , Animais , Modelos Animais de Doenças , Ecocardiografia , Hemodinâmica/fisiologia , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Necrose , Neovascularização Fisiológica , Reprodutibilidade dos Testes , Suínos , Porco Miniatura , Resultado do Tratamento , Cicatrização
12.
Acta cir. bras. ; 33(4): 386-395, abr. 2018. ilus, graf, tab
Artigo em Inglês | VETINDEX | ID: vti-734640

RESUMO

Purpose: To investigate the safety and clinical, hemodynamic and tissue improvement ability in mini pigs undergoing cell and gene therapy for the treatment of acute myocardial infarction. Methods: Thirty-two mini pigs Br1 lineage, 12 months old, undergoing induction of acute myocardial infarction by occlusion of the diagonal branch of the paraconal coronary. They were divided into 4 groups: one control group and 3 treatment groups (cell therapy and gene cell therapy). Echocardiography reviews were performed on three occasions and histopathological analysis was performed after 4 weeks. Analysis of variance (ANOVA), Tukey and Wilcoxon tests, were performed. Results: Association of vascular endothelial growth factor (VEGF) with angiopoietin1 (Ang1) presented satisfactory results in the improvement of ventricular function following ischemic cardiomyopathy in mini pigs when compared to the results of the other treated groups. Conclusion: The therapy with VEGF and the combination of VEGF with Ang1, promoted recovered function of the myocardium, characterized by reduced akinetic area and induction of neovascularization.(AU)


Assuntos
Animais , Infarto do Miocárdio/induzido quimicamente , Infarto do Miocárdio/terapia , Terapia Genética , Angiopoietina-1/uso terapêutico , Terapia Baseada em Transplante de Células e Tecidos , Porco Miniatura
13.
Acta cir. bras ; Acta cir. bras;33(4): 386-395, Apr. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-886279

RESUMO

Abstract Purpose: To investigate the safety and clinical, hemodynamic and tissue improvement ability in mini pigs undergoing cell and gene therapy for the treatment of acute myocardial infarction. Methods: Thirty-two mini pigs Br1 lineage, 12 months old, undergoing induction of acute myocardial infarction by occlusion of the diagonal branch of the paraconal coronary. They were divided into 4 groups: one control group and 3 treatment groups (cell therapy and gene cell therapy). Echocardiography reviews were performed on three occasions and histopathological analysis was performed after 4 weeks. Analysis of variance (ANOVA), Tukey and Wilcoxon tests, were performed. Results: Association of vascular endothelial growth factor (VEGF) with angiopoietin1 (Ang1) presented satisfactory results in the improvement of ventricular function following ischemic cardiomyopathy in mini pigs when compared to the results of the other treated groups. Conclusion: The therapy with VEGF and the combination of VEGF with Ang1, promoted recovered function of the myocardium, characterized by reduced akinetic area and induction of neovascularization.


Assuntos
Animais , Terapia Genética/métodos , Função Ventricular/fisiologia , Angiopoietina-1/uso terapêutico , Fator A de Crescimento do Endotélio Vascular/uso terapêutico , Terapia Baseada em Transplante de Células e Tecidos/métodos , Infarto do Miocárdio/terapia , Suínos , Porco Miniatura , Cicatrização , Ecocardiografia , Reprodutibilidade dos Testes , Resultado do Tratamento , Neovascularização Fisiológica , Modelos Animais de Doenças , Hemodinâmica/fisiologia , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/patologia , Necrose
14.
Acta Cir Bras ; 33(1): 95-101, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29412237

RESUMO

PURPOSE: To perform technically the laparoscopic sleeve gastrectomy (LSG) using a unique Intragastric Single Port (IGSG) in animal swine model, evidencing an effective and safe procedure, optimizing the conventional technique. METHODS: IGSG was performed in 4 minipigs, using a percutaneous intragastric single port located in the pre-pyloric region. The gastric stapling of the greater curvature started from the pre-pyloric region towards the angle of His by Endo GIA™ system and the specimen was removed through the single port. In the postoperative day 30, the animals were sacrificed and submitted to autopsy. RESULTS: All procedures were performed without conversion, and all survived 30 days. The mean operative time was 42 min. During the perioperative period no complications were observed during invagination and stapling. No postoperative complications occurred. Post-mortem examination showed no leaks or infectious complications. CONCLUSION: Intragastric Single Port is a feasible procedure that may be a suitable alternative technique of sleeve gastrectomy for the treatment of morbid obesity.


Assuntos
Gastrectomia/métodos , Laparoscopia/métodos , Animais , Estudos de Viabilidade , Gastrectomia/mortalidade , Laparoscopia/mortalidade , Ilustração Médica , Modelos Animais , Obesidade Mórbida/cirurgia , Duração da Cirurgia , Reprodutibilidade dos Testes , Grampeamento Cirúrgico/métodos , Suínos , Fatores de Tempo
15.
Acta cir. bras ; Acta cir. bras;33(1): 95-101, Jan. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-886247

RESUMO

Abstract Purpose: To perform technically the laparoscopic sleeve gastrectomy (LSG) using a unique Intragastric Single Port (IGSG) in animal swine model, evidencing an effective and safe procedure, optimizing the conventional technique. Methods: IGSG was performed in 4 minipigs, using a percutaneous intragastric single port located in the pre-pyloric region. The gastric stapling of the greater curvature started from the pre-pyloric region towards the angle of His by Endo GIA™ system and the specimen was removed through the single port. In the postoperative day 30, the animals were sacrificed and submitted to autopsy. Results: All procedures were performed without conversion, and all survived 30 days. The mean operative time was 42 min. During the perioperative period no complications were observed during invagination and stapling. No postoperative complications occurred. Post-mortem examination showed no leaks or infectious complications. Conclusion: Intragastric Single Port is a feasible procedure that may be a suitable alternative technique of sleeve gastrectomy for the treatment of morbid obesity.


Assuntos
Animais , Laparoscopia/métodos , Gastrectomia/métodos , Suínos , Fatores de Tempo , Obesidade Mórbida/cirurgia , Estudos de Viabilidade , Reprodutibilidade dos Testes , Grampeamento Cirúrgico/métodos , Modelos Animais , Duração da Cirurgia , Gastrectomia/mortalidade , Ilustração Médica
16.
Acta cir. bras. ; 33(1): 95-101, jan. 2018. ilus, tab
Artigo em Inglês | VETINDEX | ID: vti-18142

RESUMO

Purpose: To perform technically the laparoscopic sleeve gastrectomy (LSG) using a unique Intragastric Single Port (IGSG) in animal swine model, evidencing an effective and safe procedure, optimizing the conventional technique.Methods: IGSG was performed in 4 minipigs, using a percutaneous intragastric single port located in the pre-pyloric region. The gastric stapling of the greater curvature started from the pre-pyloric region towards the angle of His by Endo GIA system and the specimen was removed through the single port. In the postoperative day 30, the animals were sacrificed and submitted to autopsy.Results: All procedures were performed without conversion, and all survived 30 days. The mean operative time was 42 min. During the perioperative period no complications were observed during invagination and stapling. No postoperative complications occurred. Post-mortem examination showed no leaks or infectious complications.Conclusion: Intragastric Single Port is a feasible procedure that may be a suitable alternative technique of sleeve gastrectomy for the treatment of morbid obesity.(AU)


Assuntos
Animais , Laparoscopia/métodos , Gastrectomia/métodos , Obesidade Mórbida , Terapias Complementares , Modelos Animais , Porco Miniatura , Desenvolvimento Tecnológico
17.
Acta sci. vet. (Online) ; 46(supl): Pub. 351, 2018. ilus
Artigo em Inglês | VETINDEX | ID: vti-738812

RESUMO

Background: Atrial septal defects are generally classified into three types: ostium secundum, ostium primum, and sinus venosus. Diagnose is normaly confirmed with Doppler echocardiography, which can identify and classify atrial septal defects types. This cardiac anomaly may be corrected by different surgical approaches, such as cardiopulmonary bypass or transvenous approaches. Therefore, we chose to close the atrial septal defect using a total venous inflow occlusion technique (TIVO), which has been successfully used in other procedures without major postoperative complications, and are notably cheaper and requires no specialized equipment, been able to be done in different places.Case: An American Pit Bull Terrier was referred to our surgical service for ostium secundum atrial septal defect correction, by the time of surgery the patient presented dyspneic; normal capillary refill time and rectal temperature; the owner mentioned the patient exhibited exercise intolerance and delayed development compared to other dogs of the same age or from the same litter. Cardiac auscultation revealed a systolic murmur at the left base, femoral pulse was normokinetic, and patient was emaciated and prostrated at the time of clinical evaluation. Atrial septal defect was suspected and then confirmed by Doppler echocardiography that revealed a discontinuous area in the interatrial septum, and by color doppler images an aliased signal, that extended through the interatrial septum and shunted from the left to the right atria, was visualized, confirming an ostium secundum atrial septal defect. After a right intercostal thoracotomy, a subphrenic pericardiectomy was performed to provide access to the heart. Cranial and caudal vena cava as well as the azygos vein, were dissected, which allowed placement of a Satinskys clamp to proceed with TIVO. Before TIVO initiation, a pursestring suture with 3-0 polypropylene was applied to the right atrium.[...](AU)


Assuntos
Animais , Cães , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/patologia , Comunicação Interatrial/veterinária , Procedimentos Cirúrgicos Cardíacos/veterinária , Ecocardiografia Doppler/veterinária , Cardiopatias Congênitas/veterinária
18.
Acta sci. vet. (Impr.) ; 46(supl): 1-5, 2018. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1457928

RESUMO

Background: Macroscopic identification of the extravasation site of chyle in patients with chylothorax is a major challenge. Current forms of identification are invasive and/or expose patients to radiation, as in computerized tomography and radiography. A prototype device that uses infrared video thermometry images to detect temperature increments of 0.1ºC has been developed. This device can process and show real-time images or video on a monitor during surgeries. Therefore, the aim of this work was to report the first successful case in which this innovative device was tested in the transoperative period to identify the thoracic duct and its tributaries in a chylothorax surgery performed in a dog.Case: A 2-year-old male dog of the Shiba Inu breed was presented to the veterinary hospital with exercise intolerance, cough, emaciation, and no history of trauma. Clinical examination was performed along with complete blood count, biochemical analysis, and thoracic radiography. The patient exhibited dyspnea and had diminished breath sounds on chest auscultation. Radiographic images revealed moderate pleural effusion. The dog was anesthetized and submitted to thoracotomy, which enabled visualization of a chylous effusion. A sample of the effusion was collected for cytological and biochemical analyses. Subsequently, pericardiectomy was carried out, and identification of the thoracic duct and its tributaries was guided by an innovative device that generates infrared video thermometry images in real time. The extravasation site of the chyle was visualized on the images shown on a monitor. Consequently, after ligation of the tributary vessel, interruption of chyle overflow could be noticed on the monitor. Thoracotomy was routinely closed, and a drain was placed through an intercostal space after incision. Thirty days after the surgery, the dog exhibited no signs of recurrence.[...]


Assuntos
Animais , Cães , Quilotórax/cirurgia , Quilotórax/veterinária , Termometria/veterinária , Quilo , Raios Infravermelhos
19.
Acta sci. vet. (Impr.) ; 46(supl): Pub.351-2018. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1458018

RESUMO

Background: Atrial septal defects are generally classified into three types: ostium secundum, ostium primum, and sinus venosus. Diagnose is normaly confirmed with Doppler echocardiography, which can identify and classify atrial septal defects types. This cardiac anomaly may be corrected by different surgical approaches, such as cardiopulmonary bypass or transvenous approaches. Therefore, we chose to close the atrial septal defect using a total venous inflow occlusion technique (TIVO), which has been successfully used in other procedures without major postoperative complications, and are notably cheaper and requires no specialized equipment, been able to be done in different places.Case: An American Pit Bull Terrier was referred to our surgical service for ostium secundum atrial septal defect correction, by the time of surgery the patient presented dyspneic; normal capillary refill time and rectal temperature; the owner mentioned the patient exhibited exercise intolerance and delayed development compared to other dogs of the same age or from the same litter. Cardiac auscultation revealed a systolic murmur at the left base, femoral pulse was normokinetic, and patient was emaciated and prostrated at the time of clinical evaluation. Atrial septal defect was suspected and then confirmed by Doppler echocardiography that revealed a discontinuous area in the interatrial septum, and by color doppler images an aliased signal, that extended through the interatrial septum and shunted from the left to the right atria, was visualized, confirming an ostium secundum atrial septal defect. After a right intercostal thoracotomy, a subphrenic pericardiectomy was performed to provide access to the heart. Cranial and caudal vena cava as well as the azygos vein, were dissected, which allowed placement of a Satinsky’s clamp to proceed with TIVO. Before TIVO initiation, a pursestring suture with 3-0 polypropylene was applied to the right atrium.[...]


Assuntos
Animais , Cães , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/patologia , Comunicação Interatrial/veterinária , Procedimentos Cirúrgicos Cardíacos/veterinária , Cardiopatias Congênitas/veterinária , Ecocardiografia Doppler/veterinária
20.
Acta sci. vet. (Online) ; 46(supl): 1-5, 2018. ilus
Artigo em Inglês | VETINDEX | ID: vti-17903

RESUMO

Background: Macroscopic identification of the extravasation site of chyle in patients with chylothorax is a major challenge. Current forms of identification are invasive and/or expose patients to radiation, as in computerized tomography and radiography. A prototype device that uses infrared video thermometry images to detect temperature increments of 0.1ºC has been developed. This device can process and show real-time images or video on a monitor during surgeries. Therefore, the aim of this work was to report the first successful case in which this innovative device was tested in the transoperative period to identify the thoracic duct and its tributaries in a chylothorax surgery performed in a dog.Case: A 2-year-old male dog of the Shiba Inu breed was presented to the veterinary hospital with exercise intolerance, cough, emaciation, and no history of trauma. Clinical examination was performed along with complete blood count, biochemical analysis, and thoracic radiography. The patient exhibited dyspnea and had diminished breath sounds on chest auscultation. Radiographic images revealed moderate pleural effusion. The dog was anesthetized and submitted to thoracotomy, which enabled visualization of a chylous effusion. A sample of the effusion was collected for cytological and biochemical analyses. Subsequently, pericardiectomy was carried out, and identification of the thoracic duct and its tributaries was guided by an innovative device that generates infrared video thermometry images in real time. The extravasation site of the chyle was visualized on the images shown on a monitor. Consequently, after ligation of the tributary vessel, interruption of chyle overflow could be noticed on the monitor. Thoracotomy was routinely closed, and a drain was placed through an intercostal space after incision. Thirty days after the surgery, the dog exhibited no signs of recurrence.[...](AU)


Assuntos
Animais , Cães , Quilotórax/cirurgia , Quilotórax/veterinária , Termometria/veterinária , Quilo , Raios Infravermelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA