Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
1.
Rev Lat Am Enfermagem ; 32: e4209, 2024.
Artigo em Inglês, Espanhol, Português | MEDLINE | ID: mdl-38985043

RESUMO

OBJECTIVE: to analyze the integrity of N95/PFF2 masks in relation to fiber morphology, porosity, cracks and micro holes, as well as identify visible damage to their structure and components, after seven- and fifteen-day reuse protocols. METHOD: cross-sectional study. Structural and morphological characteristics of a new N95/PFF2 mask were analyzed in comparison with N95/PFF2 masks (n=10) used in seven- and fifteen-day protocols, through visual inspection and scanning electron microscopy. RESULTS: upon visual inspection, following the seven-day protocol, 40% and 60% of the N95/PFF2 masks showed, respectively, personal identification marks and external and internal dirt. Additionally, 20% exhibited loosening and/or tearing of the straps, while 100% showed some type of damage to the nose clips. In the fifteen-day protocol, all N95/PFF2 masks had dirt, loose straps and damaged nose clips, and 80% had folds. Electronic microscopy revealed an increase in pores and loosening in the weaves from seven days onwards, extending up to fifteen days, with the presence of micro holes and residues. CONCLUSION: the reuse of N95/PFF2 masks affects their structural and morphological integrity. It is crucial to carry out tests to measure the impact of this practice on the safety of health professionals.


Assuntos
Reutilização de Equipamento , Estudos Transversais , Reutilização de Equipamento/normas , Humanos , Respiradores N95/normas , Microscopia Eletrônica de Varredura , Máscaras/normas
2.
Enferm. actual Costa Rica (Online) ; (46): 58440, Jan.-Jun. 2024. tab
Artigo em Português | LILACS, BDENF - Enfermagem, SaludCR | ID: biblio-1550243

RESUMO

Resumo Introdução: A Cultura de Segurança do Paciente é considerada um importante componente estrutural dos serviços, que favorece a implantação de práticas seguras e a diminuição da ocorrência de eventos adversos. Objetivo: Identificar os fatores associados à cultura de segurança do paciente nas unidades de terapia intensiva adulto em hospitais de grande porte da região Sudeste do Brasil. Método: Estudo transversal do tipo survey e multicêntrico. Participaram 168 profissionais de saúde de quatro unidades (A, B, C e D) de terapia intensiva adulto. Foi utilizado o questionário "Hospital Survey on Patient Safety Culture". Considerou-se como variável dependente o nível de cultura de segurança do paciente e variáveis independentes aspectos sociodemográficos e laborais. Foram usadas estatísticas descritivas e para a análise dos fatores associados foi elaborado um modelo de regressão logística múltipla. Resultados: Identificou-se associação entre tipo de hospital com onze dimensões da cultura de segurança, quanto à função a categoria profissional médico, técnico de enfermagem e enfermeiro foram relacionadas com três dimensões; o gênero com duas dimensões e tempo de atuação no setor com uma dimensão. Conclusão: Evidenciou-se que o tipo de hospital, categoria profissional, tempo de atuação no setor e gênero foram associados às dimensões de cultura de segurança do paciente.


Resumen Introducción: La cultura de seguridad del paciente se considera un componente estructural importante de los servicios, que favorece la aplicación de prácticas seguras y la reducción de la aparición de acontecimientos adversos. Objetivo: Identificar los factores asociados a la cultura de seguridad del paciente en unidades de terapia intensiva adulto en hospitales de la región Sudeste del Brasil. Metodología: Estudio transversal de tipo encuesta y multicéntrico. Participaron 168 profesionales de salud de cuatro unidades (A, B, C y D) de terapia intensiva adulto. Se utilizó el cuestionario "Hospital Survey on Patient Safety Culture". Se consideró como variable dependiente el nivel de cultura de seguridad del paciente y variables independientes los aspectos sociodemográficos y laborales. Fueron usadas estadísticas descriptivas y, para analizar los factores asociados, fue elaborado un modelo de regresión logística múltiple. Resultados: Se identificó asociación entre tipo de hospital con once dimensiones de cultura de seguridad del paciente. En relación a la función, personal médico, técnicos de enfermería y personal de enfermería fueron asociados con tres dimensiones, el género con dos dimensiones y tiempo de actuación con una dimensión en el modelo de regresión. Conclusión: Se evidenció que el tipo de hospital, función, tiempo de actuación en el sector y género fueron asociados a las dimensiones de la cultura de seguridad del paciente.


Abstract Introduction: Patient safety culture is considered an important structural component of the services, which promotes the implementation of safe practices and the reduction of adverse events. Objective: To identify the factors associated with patient safety culture in adult intensive care units in large hospitals in Belo Horizonte. Method: Cross-sectional survey and multicenter study. A total of 168 health professionals from four units (A, B, C and D) of adult intensive care participated. The questionnaire "Hospital Survey on Patient Safety Culture" was used. The patient's level of safety culture was considered as a dependent variable, and sociodemographic and labor aspects were the independent variables. Descriptive statistics were used and a multiple logistic regression model was developed to analyze the associated factors. Results: An association was identified between the type of hospital and eleven dimensions of the safety culture. In terms of function, the doctors, nursing technicians, and nurse were related to three dimensions; gender with two dimensions, and time working in the sector with one dimension. Conclusion: It was evidenced that the type of hospital, function, time working in the sector, and gender were associated with the dimensions of patient safety culture.


Assuntos
Humanos , Masculino , Feminino , Segurança do Paciente , Unidades de Terapia Intensiva , Brasil , Indicadores de Qualidade em Assistência à Saúde/normas
3.
J. nurs. health ; 14(2): 1426844, jun. 2024.
Artigo em Português | LILACS, BDENF - Enfermagem | ID: biblio-1560804

RESUMO

Objetivo:construir e validar um instrumento de avaliação do processamento de produtos para saúde em centro de materiais e esterilização. Método:estudo metodológico realizado com 22 profissionais de saúde, sendo oito juízes especialistas e 14 enfermeiros responsáveis pelo setor de apoio. Foram realizadas quatro rodadas da técnica Delphi e posteriormente, as propriedades psicométricas foram analisadas por meio do Índice de Validade de Conteúdo e do teste Alfa de Cronbach. Resultados: o tempo de experiência dos juízes especialistas variou de 2 a 18 anos, com média de 7,7 (±6,1). A validação de conteúdo obteve média global de 0,95 (±0,05) e mediana de 0,97. O teste Alfa de Cronbach apresentou boa consistência interna após aplicação do pré-teste. Ao final, a versão do instrumento foi consolidada em 43 questões, divididas em três eixos de avaliação. Conclusão: este instrumento poderá ser utilizado em nível nacional, visto que suas propriedades psicométricas apresentaram valores satisfatórios.


Objective: to develop and validate an assessment instrument for the processing of healthcare products in a central materials and sterilization centers. Method:a methodological study was conducted with 22 healthcare professionals, comprising eight expert judges and 14 nurses responsible for the support sector. Four rounds of the Delphi technique were carried out, and subsequently, the psychometric properties were analyzed using the Content Validity Index and Cronbach's Alpha test.Results: the experience of the expert judges ranged from 2 to 18 years, with an average of 7.7 (±6.1). Content validation yielded a mean score of 0.95 (±0.05) and a median of 0.97. The Cronbach's Alpha test showed good internal consistency. Atthe end, the instrument version was consolidated into 43 questions.Conclusion: this instrument can be used nationally, asits psychometric properties showed satisfactory values.


Objetivo: construir y validar un instrumento para evaluar el procesamiento de productos sanitarios en centrosde materiales y esterilización.Método: estudio metodológico realizado con 22 profesionales de la salud, ocho de los cuales fueron jueces expertos y 14 enfermeros responsables del sector de apoyo. Se realizaron cuatro rondas de la técnica Delphi y posteriormente se analizaron las propiedades psicométricas mediante el Índice de Validez de Contenido y la prueba Alfa de Cronbach. Resultados:la experiencia de los jueces expertos osciló entre 2 y 18 años, con una media de 7,7 (±6,1). La validación de contenido obtuvo una media global de 0,95 (±0,05) y una mediana de 0,97. La prueba Alfa de Cronbach mostró buena consistencia interna luego de aplicar el pretest.Conclusión: este instrumento puede ser utilizado a nivel nacional, ya que sus propiedades psicométricas presentaron valores satisfactorios.


Assuntos
Centro de Material e Esterilização , Esterilização , Desinfecção , Enfermagem , Estudo de Validação
4.
Rev. latinoam. enferm. (Online) ; 32: e4209, 2024. graf
Artigo em Inglês | LILACS, BDENF - Enfermagem | ID: biblio-1565568

RESUMO

Objective: to analyze the integrity of N95/PFF2 masks in relation to fiber morphology, porosity, cracks and micro holes, as well as identify visible damage to their structure and components, after seven- and fifteen-day reuse protocols. Method: cross-sectional study. Structural and morphological characteristics of a new N95/PFF2 mask were analyzed in comparison with N95/PFF2 masks (n=10) used in seven- and fifteen-day protocols, through visual inspection and scanning electron microscopy. Results: upon visual inspection, following the seven-day protocol, 40% and 60% of the N95/PFF2 masks showed, respectively, personal identification marks and external and internal dirt. Additionally, 20% exhibited loosening and/or tearing of the straps, while 100% showed some type of damage to the nose clips. In the fifteen-day protocol, all N95/PFF2 masks had dirt, loose straps and damaged nose clips, and 80% had folds. Electronic microscopy revealed an increase in pores and loosening in the weaves from seven days onwards, extending up to fifteen days, with the presence of micro holes and residues. Conclusion: the reuse of N95/PFF2 masks affects their structural and morphological integrity. It is crucial to carry out tests to measure the impact of this practice on the safety of health professionals.


Objetivo: analizar la integridad de mascarillas N95/PFF2 con relación a la morfología de las fibras, porosidad, grietas y microagujeros, así como identificar daños visibles en su estructura y componentes, luego de protocolos de reutilización de siete y quince días. Método: estudio transversal. Se analizaron las características estructurales y morfológicas de una mascarilla N95/PFF2 nueva en comparación con las mascarillas N95/PFF2 (n=10) utilizadas en protocolos de siete y quince días, mediante inspección visual y microscopía electrónica de barrido. Resultados: tras la inspección visual, siguiendo el protocolo de siete días, el 40% y el 60% de las mascarillas N95/PFF2 mostraron, respectivamente, marcas de identificación personal y suciedad externa e interna. Además, el 20% presentó aflojamiento y/o desgarro de las correas de sujeción, mientras que el 100% presentó algún tipo de daño en los clips nasales. En el protocolo de quince días, todas las mascarillas N95/PFF2 tenían suciedad, correas de sujeción sueltas y clips nasales dañados, y el 80% tenía pliegues. La microscopía electrónica reveló un aumento de poros y aflojamiento en las tramas a partir de los siete días, extendiéndose hasta los quince días, con presencia de microagujeros y residuos. Conclusión: la reutilización de las mascarillas N95/PFF2 compromete su integridad estructural y morfológica. Es crucial realizar pruebas para medir el impacto de esta práctica en la seguridad de los profesionales de la salud.


Objetivo: analisar a integridade das máscaras N95/PFF2 em relação à morfologia das fibras, porosidade, fissuras e micro furos, bem como identificar danos visíveis em sua estrutura e componentes, após protocolos de reutilização de sete e quinze dias. Método: estudo transversal. Características estruturais e morfológicas de uma máscara N95/PFF2 nova foram analisadas em comparação com máscaras N95/PFF2 (n=10) utilizadas em protocolos de sete e quinze dias, por meio da inspeção visual e microscopia eletrônica de varredura. Resultados: na inspeção visual, seguindo o protocolo de sete dias, 40% e 60% das máscaras N95/PFF2 apresentaram, respectivamente, marcas de identificação pessoal e sujidades externas e internas. Além disso, 20% exibiram afrouxamento e/ou rompimento das tiras de fixação, enquanto 100% mostraram algum tipo de dano nos clipes nasais. No protocolo de quinze dias, todas as máscaras N95/PFF2 apresentavam sujidade, tiras de fixação frouxas e clipes nasais comprometidos; 80% possuíam dobras. A microscopia eletrônica revelou aumento dos poros e afrouxamento nas tramas a partir de sete dias, ampliando-se até quinze dias, com presença de micro furos e detritos. Conclusão: a reutilização das máscaras N95/PFF2 compromete a integridade estrutural e morfológica. É crucial realizar testes para mensurar o impacto dessa prática na segurança dos profissionais de saúde.


Assuntos
Microscopia Eletrônica de Varredura , Saúde Ocupacional , Pessoal de Saúde , Reutilização de Equipamento , Equipamento de Proteção Individual , Respiradores N95
5.
Gastroenterol Nurs ; 46(6): 455-464, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37700439

RESUMO

Contamination due to failures or omissions in the reprocessing steps of gastrointestinal endoscopes is common in clinical practice. Ensuring the proper execution of each step is a challenge for reprocessing personnel. This cross-sectional study was conducted in an endoscopy setting between March and May 2021. We performed interviews about reprocessing practices, analyzed the life history of the equipment, and performed inspections through a borescope video of gastrointestinal endoscope channels that were stored and ready for use. A borescope is a complementary tool used to validate endoscope reprocessing, evaluate the internal visualization of channels, and identify changes that can compromise the safety of its use, which are often not detected in the leak test. Thirteen biopsy channels from stored gastrointestinal endoscopes were inspected. We found that 85% had stains and grooves, 69% contained moisture, and 46% had debris. There was at least one noncompliance issue in all of the channels inspected.


Assuntos
Desinfecção , Reutilização de Equipamento , Humanos , Estudos Transversais , Endoscópios , Endoscópios Gastrointestinais , Contaminação de Equipamentos/prevenção & controle
6.
Acta Paul. Enferm. (Online) ; 36: eAPE01714, 2023. tab
Artigo em Português | LILACS-Express | LILACS, BDENF - Enfermagem | ID: biblio-1505428

RESUMO

Resumo Objetivo Avaliar a adesão às ações de prevenção e controle da infecção de sítio cirúrgico, adotadas na prática clínica de acordo com as recomendações propostas pela Organização Mundial de Saúde: realização da auditoria de momento da administração de antibiótico, tricotomia com tricotomizador elétrico/lâmina descartável, confirmação da esterilidade dos materiais e, vigilância e divulgação das taxas de infecção de sítio cirúrgico. Métodos Estudo observacional transversal, realizado em 30 hospitais de grande porte do estado de Minas Gerais, de fevereiro de 2018 a abril de 2019, a partir de uma auditoria de um procedimento cirúrgico, diagnóstico situacional e entrevista com os Serviços de Controle de Infecção Hospitalar. Resultados Em 93,3% dos Serviços de Controle de Infecção Hospitalar foram referidos protocolos para uso de antibiótico profilático e auditorias de adesão, 69% informaram tricotomia com tricotomizador elétrico; todos realizavam a vigilância da infecção de sítio cirúrgico, no entanto, apenas 63,3% realizavam a divulgação das taxas. No diagnóstico situacional, a tricotomia foi realizada em 76,7% dentro da sala cirúrgica com tricotomizador elétrico (56,7%). Na auditoria do momento de administração do antimicrobiano profilático entre 30-60 minutos antes da incisão cirúrgica identificou-se conformidade em 63,3%; 93,3% dos serviços confirmavam a esterilidade dos materiais por meio de indicadores de processo. Conclusão Verificou-se divergências entre recomendações do Serviço de Controle de Infecção Hospitalar e adesão às boas práticas durante diagnóstico situacional e auditoria de procedimentos cirúrgicos, reforçando a necessidade de treinamentos e auditorias visando adesão efetiva às práticas dos profissionais a tais medidas.


Resumen Objetivo Evaluar la adhesión a las acciones de prevención y control de infecciones del sitio quirúrgico adoptadas en la práctica clínica, de acuerdo con las recomendaciones propuestas por la Organización Mundial de la Salud: realización de auditoría del momento de administración del antibiótico, tricotomía con tricotomizador eléctrico/lámina descartable, confirmación de esterilidad del material y control y difusión de índices de infección del sitio quirúrgico. Métodos Estudio observacional transversal, realizado en 30 hospitales de gran tamaño del estado de Minas Gerais, de febrero de 2018 a abril de 2019, a partir de una auditoría de un procedimiento quirúrgico, diagnóstico situacional y entrevista con los Servicios de Control de Infecciones Hospitalarias. Resultados En el 93,3 % de los Servicios de Control de Infecciones Hospitalarias se citaron protocolos para el uso de antibiótico profiláctico y auditorías de adhesión, el 69 % informó tricotomía con tricotomizador eléctrico, todos realizaban el control de infecciones del sitio quirúrgico, pero solo el 63,3 % realizaba la difusión de los índices. En el diagnóstico situacional, la tricotomía fue realizada en el 76,7 % dentro del quirófano con tricotomizador eléctrico (56,7 %). En la auditoría del momento de administración del antimicrobiano profiláctico de 30 a 60 minutos antes de la incisión quirúrgica, se identificó conformidad en el 63,3 %, el 93,3 % de los servicios confirmó la esterilidad del material por medio de indicadores de proceso. Conclusión Se verificaron divergencias entre las recomendaciones del Servicio de Control de Infecciones Hospitalarias y la adhesión a las buenas prácticas durante el diagnóstico situacional y auditoría de procedimientos quirúrgicos, lo que refuerza la necesidad de capacitaciones y auditorías para una efectiva adhesión de las prácticas de los profesionales a tales medidas.


Abstract Objective To assess compliance with actions for surgical site infection prevention and control, adopted in clinical practice in accordance with the recommendations proposed by the World Health Organization: auditing the moment of antibiotic administration, trichotomy with an electric clipper/disposable blade, material sterility confirmation, and surveillance and dissemination of surgical site infection rates. Methods This is a cross-sectional observational study, carried out in 30 hospitals in the state of Minas Gerais, from February 2018 to April 2019, based on an audit of a surgical procedure, situational diagnosis and interview with Hospital Infection Control Services. Results In 93.3% of Hospital Infection Control Services, protocols for prophylactic antibiotic use and compliance audits were reported, 69% reported trichotomy with an electric clipper. All carried out surgical site infection surveillance, however, only 63.3% carried out rate disclosure. In the situational diagnosis, trichotomy was performed in 76.7% inside the operating room with an electric clipper (56.7%). In the audit of the moment of antimicrobial administration between 30-60 minutes before surgical incision, compliance was identified in 63.3%; 93.3% of services confirmed material sterility through process indicators. Conclusion Differences were found between recommendations from the Hospital Infection Control Service and compliance with good practices during situational diagnosis and auditing of surgical procedures, reinforcing the need for training and audits aimed at effectively complying with professionals' practices regarding such measures.

7.
Ciênc. cuid. saúde ; 22: e66055, 2023. tab
Artigo em Português | LILACS, BDENF - Enfermagem | ID: biblio-1447930

RESUMO

RESUMO Objetivo: analisar a incidência das infecções de sítio cirúrgico (ISC) em pacientes submetidos a cirurgias neurológicas e ortopédicas e seus determinantes em um hospital público. Método: estudo de coorte retrospectivo, conduzido entre pacientes submetidos a cirurgias neurológicas e ortopédicas, de janeiro de 2015 a dezembro de 2020. Resultados: dos 3.029 procedimentos cirúrgicos realizados, 1.327 (43,8%) foram neurocirúrgicos; e 1.702 (56,2%), ortopédicos. A incidência da ISC foi 6,7% (89) em neurocirurgias e 3,3% (56) em ortopedias. A taxa global e de óbitos foi 4,8% e 12,4%, respectivamente. Na análise univariada, os fatores de risco associados às ISC em neurocirurgiasenvolveram tempo cirúrgico (>231 minutos), pontuação da American Society of Anesthesiologistsmaior que doise cirurgias emergenciais; para os procedimentos ortopédicos: cirurgias emergenciais, tempo de internação pré-operatório (>quatro dias) e cirúrgico (>149 minutos). Na análise multivariada, permaneceram cirurgias emergenciais e maior tempo cirúrgico como fatores de risco de ISC para ambas as especialidades;e, para as cirurgias ortopédicas e neurológicas, tempo de internação pré-operatório e classificação ASA, respectivamente. Conclusão: a taxa de incidência das ISC e de mortalidade bem como os fatores de risco identificados neste estudo devem ser considerados para elaborar estratégias destinadas a prevenir e controlar essas infecções.


RESUMEN Objetivo: analizar la incidencia de las infecciones de sitio quirúrgico (ISC) en pacientes sometidos a cirugías neurológicas y ortopédicas y sus determinantes en un hospital público. Método: estudio de cohorte retrospectivo, realizado entre pacientes sometidos a cirugías neurológicas y ortopédicas, de enero de 2015 a diciembre de 2020. Resultados: de los 3.029 procedimientos quirúrgicos realizados, 1.327 (43,8%) fueron neuroquirúrgicos; y 1.702 (56,2%), ortopédicos. La incidencia de la ISC fue 6,7% (89) en neurocirugía y 3,3% (56) en ortopedias. La tasa global y de muertes fue 4,8% y 12,4%, respectivamente. En el análisis univariado, los factores de riesgo asociados a las ISC en neurocirugía involucraron tiempo quirúrgico (>231 minutos), puntuación de la American Society of Anesthesiologists (ASA) mayor que dos y cirugías de emergencia; para los procedimientos ortopédicos: cirugías de emergencia, tiempo de internación preoperatorio (> cuatro días) y quirúrgico (>149 minutos). En el análisis multivariado, permanecieron cirugías de emergencia y mayor tiempo quirúrgico como factores de riesgo de ISC para ambas especialidades; y, para las cirugías ortopédicas y neurológicas, tiempo de internación preoperatorio y clasificación ASA, respectivamente. Conclusión: la tasa de incidencia de las ISC y de mortalidad, así como los factores de riesgo identificados en este estudio, debenser consideradosa la hora de elaborar estrategias para prevenir y controlar estas infecciones.


ABSTRACT Objective: to analyze the incidence of surgical site infections (SSI) in patients submitted to neurological and orthopedic surgeries and their determinants in a public hospital. Method: retrospective cohort study, conducted between patients submitted to neurological and orthopedic surgeries, from January 2015 to December 2020. Results: of the 3,029 surgical procedures performed, 1,327 (43.8%) were neurosurgical; and 1,702 (56.2%) were orthopedic. The incidence of SSI was 6.7% (89) in neurosurgeries and 3.3% (56) in orthopedic surgery. The overall rate and death rates were 4.8% and 12.4%, respectively. In the univariate analysis, the risk factors associated with SSI in neurosurgeries involved surgical time (>231 minutes), an American Society of Anesthesiologists score greater than two and emergency surgeries; the risk factors for orthopedic procedures were emergency surgeries, preoperative hospitalization time (> four days), and surgical procedures (>149 minutes). In the multivariate analysis, emergency surgeries and longer surgical time remained as risk factors for SSI for both specialties; the SSI risk factors for orthopedic and neurological surgeries were preoperative hospitalization time and ASA classification, respectively. Conclusion: the incidence rate of SSI and mortality, as well as the risk factors identified in this study, should be considered in order to develop strategies aimed at preventing and controlling these infections.


Assuntos
Humanos , Masculino , Feminino , Serviços de Vigilância Epidemiológica , Neurologia
8.
Mundo Saúde (Online) ; 47: e12792022, 2023.
Artigo em Inglês, Português | LILACS-Express | LILACS | ID: biblio-1444087

RESUMO

A infecção do trato urinário é um dos agravos mais comuns durante a assistência à saúde, sobretudo na unidade de terapia intensiva, e, em sua maioria, é associada ao uso do cateter vesical, contribuindo, de forma significativa, na mortalidade, na morbidade e no custo de tratamento. O objetivo foi avaliar o efeito de uma intervenção educacional no conhecimento dos profissionais intensivistas sobre medidas de prevenção de infecção do trato urinário associada ao uso do cateter vesical. Trata-se de um estudo de intervenção, do tipo antes e depois, realizado em unidade de terapia intensiva com dez leitos de um hospital de alta complexidade. A coleta de dados contemplou três momentos: pré-intervenção, intervenção e pós-intervenção, realizada entre janeiro de 2018 a janeiro de 2019. Na pré e na pós-intervenção, foi feita entrevista por meio de um questionário estruturado. A intervenção ocorreu por sessão de treinamento com metodologias ativas e demonstrações práticas. Observou-se uma tendência ao aumento do conhecimento em todos os itens avaliados para prevenção da infecção do trato urinário associada ao uso do cateter vesical, com diferenças significativas (p<0,05) nos momentos para higienização das mãos, indicações para inserção do cateter vesical, medidas de barreira na técnica de inserção e prevenção dessa infecção durante a manipulação e manutenção do cateter vesical. A intervenção proporcionou aumento do conhecimento dos profissionais sobre as medidas de prevenção. Entretanto, lacunas relacionadas a estas práticas ainda foram verificadas e intervenções em longo prazo devem ser conduzidas com vistas à melhoria e segurança do cuidado.


Urinary tract infection is one of the most common problems during health care, especially in the intensive care unit, and is mostly associated with the use of a urinary catheter, contributing significantly to mortality, morbidity, and the cost of treatment. The objective of this study was to evaluate the effect of an educational intervention on the knowledge of intensive care professionals upon measures to prevent urinary tract infections associated with the use of a urinary catheter. This is a before-and-after intervention study, carried out in a ten-bed intensive care unit in a high-complexity hospital. Data collection included three moments: pre-intervention, intervention, and post-intervention, carried out between January 2018 and January 2019. In the pre- and post-intervention, an interview was carried out using a structured questionnaire. The intervention took place through a training session with active methodologies and practical demonstrations. There was a trend towards increased knowledge in all items evaluated for the prevention of urinary tract infections associated with the use of a urinary catheter, with significant differences (p<0.05) concerning hand hygiene, indications for catheter insertion bladder, barrier measures in the insertion technique, and prevention of this infection during manipulation and maintenance of the bladder catheter. The intervention provided an increase in the knowledge of professionals about prevention measures. However, gaps related to these practices were still being verified and long-term interventions should be conducted with a view to the improvement and safety of care.

9.
Rev Lat Am Enfermagem ; 30: e3684, 2022.
Artigo em Inglês, Português, Espanhol | MEDLINE | ID: mdl-36287399

RESUMO

OBJECTIVE: to analyze the cleaning process of gastroscopes, colonoscopes and duodenoscopes in eight in-hospital health services. METHOD: a cross-sectional study conducted with 22 endoscopes (eight gastroscopes, eight colonoscopes and six duodenoscopes), and microbiological analysis of 60 samples of air/water channels (all endoscopes) and elevator (duodenoscopes), in addition to protein testing. Descriptive statistics with calculation of frequencies and central tendency measures was used in data analysis. RESULTS: the processing of 22 endoscopes was monitored with microbiological analysis for 60 channels. In the pre-cleaning procedure, in 82.3% (14/17) of the devices, gauze was used in cleaning the insertion tube. Incomplete immersion of the endoscope in detergent solution occurred in 72.3% (17/22) of the cases, and in 63.6% (14/22) there was no standardization of filling-in of the channels. Friction of the biopsy channel was not performed in 13.6% (3/22) of the devices. In the microbiological analysis, 25% (7/32) of the samples from the stored endoscopes were positive for microbial growth (from 2x101 to 9.5x104 CFU/mL), while after processing, contamination was 32% (9/28). Protein residues in the elevator channel were detected in 33% of duodenoscopes. CONCLUSION: the results indicate important gaps in the stages of pre-cleaning and cleaning of endoscopes that, associated with presence of protein residues and growth of microorganisms of epidemiological importance, indicate limitations in safety of the processing procedures, which can compromise the disinfection processes and, consequently, their safe use among patients subjected to such tests.


Assuntos
Detergentes , Contaminação de Equipamentos , Humanos , Contaminação de Equipamentos/prevenção & controle , Estudos Transversais , Endoscópios/microbiologia , Desinfecção/métodos , Hospitais
10.
Rev Bras Enferm ; 75(3): e20210216, 2022.
Artigo em Inglês, Português | MEDLINE | ID: mdl-35137886

RESUMO

OBJECTIVES: to identify the safe storage time for the use of flexible gastrointestinal endoscopes after high-level disinfection, as well as the defining criteria for this time. METHODS: an integrative literature review was carried out in the Virtual Health Library, PubMed, Scopus, and Web of Science, considering original articles published since 2000. RESULTS: eleven articles were selected, whose storage times ranged from 1 to 56 days, with a predominance of one to seven days (73%). Several criteria were used to define this time, predominantly the premise of efficient processing (100%), use of alcohol flush (64%), use of drying cabinets (18%), among others. CONCLUSIONS: the criteria for determining the storage time did not show a consensus for clinical practice. Expanding the discussion of this theme with the definition of the minimum necessary conditions is of fundamental importance for the reduction of risks and safety of the procedure and the patient.


Assuntos
Endoscópios Gastrointestinais , Contaminação de Equipamentos , Desinfecção , Humanos
12.
Rev. latinoam. enferm. (Online) ; 30: e3684, 2022. tab, graf
Artigo em Inglês | LILACS, BDENF - Enfermagem | ID: biblio-1409620

RESUMO

Abstract Objective: to analyze the cleaning process of gastroscopes, colonoscopes and duodenoscopes in eight in-hospital health services. Method: a cross-sectional study conducted with 22 endoscopes (eight gastroscopes, eight colonoscopes and six duodenoscopes), and microbiological analysis of 60 samples of air/water channels (all endoscopes) and elevator (duodenoscopes), in addition to protein testing. Descriptive statistics with calculation of frequencies and central tendency measures was used in data analysis. Results: the processing of 22 endoscopes was monitored with microbiological analysis for 60 channels. In the pre-cleaning procedure, in 82.3% (14/17) of the devices, gauze was used in cleaning the insertion tube. Incomplete immersion of the endoscope in detergent solution occurred in 72.3% (17/22) of the cases, and in 63.6% (14/22) there was no standardization of filling-in of the channels. Friction of the biopsy channel was not performed in 13.6% (3/22) of the devices. In the microbiological analysis, 25% (7/32) of the samples from the stored endoscopes were positive for microbial growth (from 2x101 to 9.5x104 CFU/mL), while after processing, contamination was 32% (9/28). Protein residues in the elevator channel were detected in 33% of duodenoscopes. Conclusion: the results indicate important gaps in the stages of pre-cleaning and cleaning of endoscopes that, associated with presence of protein residues and growth of microorganisms of epidemiological importance, indicate limitations in safety of the processing procedures, which can compromise the disinfection processes and, consequently, their safe use among patients subjected to such tests.


Resumo Objetivo: analisar o processo de limpeza de gastroscópios, colonoscópios e duodenoscópios em oito serviços de saúde intra-hospitalar. Método: estudo transversal com 22 endoscópios, sendo oito gastroscópios, oito colonoscópios e seis duodenoscópios, e análise microbiológica de 60 amostras dos canais de ar/água (todos os endoscópios) e elevador (duodenoscópios), além de teste de proteína. Na análise dos dados, utilizou-se estatística descritiva, com cálculo de frequências e medidas de tendência central. Resultados: o processamento de 22 endoscópios foi acompanhado com análise microbiológica de 60 canais. Na pré-limpeza, em 82,3% (14/17) dos equipamentos, foi utilizada gaze na limpeza do tubo de inserção. A imersão incompleta do endoscópio em solução detergente ocorreu em 72,3% (17/22) dos casos, e em 63,6% (14/22) não havia padronização do preenchimento dos canais. A fricção do canal de biópsia não foi realizada em 13,6% (3/22) dos equipamentos. Na análise microbiológica, 25% (7/32) das amostras dos endoscópios armazenados foram positivas para crescimento microbiano (2x101 a 9,5x104 UFC/mL), enquanto após o processamento, a contaminação foi de 32% (9/28). Resíduos de proteína no canal do elevador foram detectados em 33% dos duodenoscópios. Conclusão: os resultados apontam lacunas importantes nas etapas de pré-limpeza e limpeza dos endoscópios que, associadas à presença de resíduos de proteína e ao crescimento de microrganismo de importância epidemiológica, sinalizam limitações na segurança do processamento, que podem comprometer os processos de desinfecção e consequentemente seu uso seguro entre pacientes submetidos a tais exames.


Resumen Objetivo: analizar el proceso de limpieza de gastroscopios, colonoscopios y duodenoscopios en ocho servicios de salud intrahospitalarios. Método: estudio transversal con 22 endoscopios, de los cuales ocho eran gastroscopios, ocho colonoscopios y seis duodenoscopios, y análisis microbiológico de 60 muestras de los canales de aire/agua (todos los endoscopios) y elevador (duodenoscopios), además de prueba de proteínas. En el análisis de los datos se utilizó estadística descriptiva, con cálculo de frecuencias y medidas de tendencia central. Resultados: el procesamiento de los 22 endoscopios fue monitoreado con el análisis microbiológico de 60 canales. En la prelimpieza, en el 82,3% (14/17) de los equipos se utilizó gasa para limpiar el tubo de inserción. En el 72,3% (17/22) de los casos la inmersión del endoscopio en solución detergente fue incompleta y en el 63,6% (14/22) no hubo estandarización del llenado de los canales. La fricción del canal de biopsia no se realizó en el 13,6% (3/22) de los equipos. En el análisis microbiológico, el 25% (7/32) de las muestras endoscópicas almacenadas dio positivo para crecimiento microbiano (2x101 a 9,5x104 UFC/ml), mientras que después del procesamiento, la contaminación fue del 32% (9/28). Se detectaron residuos de proteína en el canal elevador en el 33% de los duodenoscopios. Conclusión: los resultados indican que hay importantes lagunas en las etapas de prelimpieza y limpieza de los endoscopios que, junto con la presencia de residuos de proteínas y del crecimiento de microorganismos de importancia epidemiológica, indican limitaciones en la seguridad del procesamiento, que pueden comprometer los procesos de desinfección y, por ende, el uso seguro en los pacientes que se someten a esos procedimientos.


Assuntos
Humanos , Desinfecção , Infecção Hospitalar , Contaminação de Equipamentos/prevenção & controle , Estudos Transversais , Endoscópios/microbiologia , Detergentes
13.
Rev. bras. enferm ; Rev. bras. enferm;75(3): e20210216, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BDENF - Enfermagem | ID: biblio-1357028

RESUMO

ABSTRACT Objectives: to identify the safe storage time for the use of flexible gastrointestinal endoscopes after high-level disinfection, as well as the defining criteria for this time. Methods: an integrative literature review was carried out in the Virtual Health Library, PubMed, Scopus, and Web of Science, considering original articles published since 2000. Results: eleven articles were selected, whose storage times ranged from 1 to 56 days, with a predominance of one to seven days (73%). Several criteria were used to define this time, predominantly the premise of efficient processing (100%), use of alcohol flush (64%), use of drying cabinets (18%), among others. Conclusions: the criteria for determining the storage time did not show a consensus for clinical practice. Expanding the discussion of this theme with the definition of the minimum necessary conditions is of fundamental importance for the reduction of risks and safety of the procedure and the patient.


RESUMEN Objetivos: identificar el tiempo de almacenamiento seguro para utilización de endoscopios flexibles gastrointestinales después de la desinfección de alto nivel, así como los criterios definidores de ese tiempo. Métodos: realizado una revisión integrativa de la literatura en la Biblioteca Virtual en Salud, PubMed, Scopus y Web of Science, considerando artículos originales publicados desde 2000. Resultados: fueron seleccionados 11 artículos, cuyos tiempos de almacenamiento variaron entre 1 y 56 días, con predominio de uno a siete días (73%). Utilizados diversos criterios para definición de ese tiempo, siendo predominantes la premisa del procesamiento eficiente (100%), uso de flush de alcohol (64%), armarios de secado (18%), entre otros. Conclusiones: los criterios para determinación del tiempo de almacenamiento no evidenciaron un consenso para práctica clínica. Ampliar la discusión de esa temática con definición de las condiciones mínimas necesarias es de fundamental importancia para la reducción de riesgos y seguridad del procedimiento y del paciente.


RESUMO Objetivos: identificar o tempo de armazenamento seguro para utilização de endoscópios flexíveis gastrointestinais após a desinfecção de alto nível, bem como os critérios definidores desse tempo. Métodos: realizou-se uma revisão integrativa da literatura na Biblioteca Virtual em Saúde, PubMed, Scopus e Web of Science, considerando artigos originais publicados desde 2000. Resultados: foram selecionados 11 artigos, cujos tempos de armazenamento variaram entre 1 e 56 dias, com predomínio de um a sete dias (73%). Utilizaram-se diversos critérios para definição desse tempo, sendo predominantes a premissa do processamento eficiente (100%), uso de flush de álcool (64%), uso de armários de secagem (18%), entre outros. Conclusões: os critérios para determinação do tempo de armazenamento não evidenciaram um consenso para prática clínica. Ampliar a discussão dessa temática com definição das condições mínimas necessárias é de fundamental importância para a redução de riscos e segurança do procedimento e do paciente.

14.
Rev Bras Enferm ; 74(3): e20200759, 2021.
Artigo em Inglês, Português | MEDLINE | ID: mdl-34287490

RESUMO

OBJECTIVES: to evaluate the microbial load and adherence of Escherichia coli in different areas of the surgical instrument surface exposed to experimental contamination over time. METHODS: experimental study in which fragments of crile forceps (serrated, rod and rack) were contaminated by immersion in Tryptic Soy Broth, containing 106 CFU/mL of E. coli, for 1, 2, 4, 6, 8, 12 and 24 hours. Microbial load and bacterial adherence were evaluated using microbiological culture and scanning electron microscopy, respectively. RESULTS: there was an increase in the microbial load on the surgical instrument, proportional to the contamination interval, ranging from 102 after 1 hour to 105 CFU/cm2 in 24 hours. The presence of exopolysaccharide was detected after two hours of contamination. CONCLUSIONS: microbial load and adhesion of E. coli increased over time, reaching 105 CFU/cm2 after 24 hours of contamination, starting biofilm formation after two hours.


Assuntos
Escherichia coli , Aço Inoxidável , Biofilmes , Contagem de Colônia Microbiana , Humanos , Instrumentos Cirúrgicos
15.
Rev Gaucha Enferm ; 42(spe): e20200146, 2021.
Artigo em Inglês, Português | MEDLINE | ID: mdl-33787720

RESUMO

OBJECTIVE: To evaluate the protocols on decontamination/reuse of N95 masks available in the literature in times of the Covid-19 pandemic. METHOD: Integrative literature review, in the period from 2010 to 2020, on the databases MEDLINE/PubMed, Science Direct, Cochrane, SAGE journals, Web of Science, Scopus, Embase and Wiley, with the descriptors Masks AND Respiratory protective devices; Mask OR N95 AND Covid-19; N95 AND Respirators; Decontamination AND N95 AND Coronavirus; Facemask OR Pandemic. RESULTS: Twelve studies were included, of which 3 (30.0%) used ultraviolet germicidal irradiation and indicated mask deterioration between 2 and 10 cycles, 4 (40.0%) used hydrogen peroxide vapor, and seal loss varied from 5 to 20 cycles, 4 (33.3%) evaluated the structural integrity of the N95 mask through visual inspection and 6 (54.4%), its filtration efficiency. CONCLUSION: Reuse strategies to overcome a shortage of devices in the face of the pandemic challenge the current concept for good practices in health-product processing.


Assuntos
COVID-19/epidemiologia , Descontaminação/métodos , Reutilização de Equipamento , Respiradores N95/virologia , Pandemias , Anti-Infecciosos Locais , Desinfetantes , Desinfecção/métodos , Óxido de Etileno , Filtração/instrumentação , Humanos , Peróxido de Hidrogênio , Raios Ultravioleta
16.
Texto & contexto enferm ; 30: e20210160, 2021. tab, graf
Artigo em Inglês | LILACS, BDENF - Enfermagem | ID: biblio-1347923

RESUMO

ABSTRACT Objective: to know the factors that exert an influence on the health professionals' perception of the risk of becoming contaminated with COVID-19 in Brazil. Methods: a survey conducted from May to October 2020 with 436 active health professionals working in the front line against COVID-19. Descriptive analyses were used and a structural equation model from an exploratory factor analysis was estimated. Results: the health professionals' perception on contracting COVID-19 was considered as medium to very high for 72% of the respondents. In the structural equation model, knowledge of the treatment for COVID-19, preparation of the health professionals to work, and safety in the institutional protocol together with confidence in official protocols and disclosures through social, printed and television media exerted an influence on confidence to face the pandemic (P<0.05). This self-confidence along with the male gender were significant determinants (P<0.001) for the perception of the possibility of becoming contaminated. Conclusion: this study may contribute to the realization of strategies, public policies and guidelines that may impact on improving self-confidence and protecting the health professionals in their performance during the COVID-19 pandemic.


RESUMEN Objetivo: conocer los factores que influencian la percepción del riesgo de infección por COVID-19 de los profesionales de salud en Brasil. Métodos: estudio del tipo survey realizado entre mayo y octubre de 2020 con 436 profesionales de salud que trabajan en la primera línea de combate contra el COVID-19. Se utilizaron análisis descriptivos y se estimó un modelo de ecuaciones estructurales a partir de un análisis factorial exploratorio. Resultados: la percepción de los profesionales de salud con respecto a contraer COVID-19 se consideró entre media y muy alta en el 72% de los encuestados. En el modelo de ecuaciones estructurales, el conocimiento sobre el tratamiento del COVID-19, la preparación de los profesionales de salud para trabajar, y la confianza en el protocolo institucional, en conjunto con la confianza en protocolos oficiales y diversas informaciones divulgadas a través de medios sociales, impresos y televisivos influenciaron la autoconfianza para enfrentar la pandemia (P<0,05). Dicha autoconfianza, junto con el sexo masculino, fueron determinantes significativos (P<0,001) para la percepción de la posibilidad de contagio. Conclusión: este estudio podrá contribuir para que se lleven adelante estrategias, políticas públicas y directrices que repercutan sobre la mejora de la autoconfianza y sobre la protección de los profesionales de salud frente a su desempeño en la pandemia de COVID-19.


RESUMO Objetivo: conhecer os fatores que influenciam a percepção do risco dos profissionais de saúde para se contaminarem com Covid-19 no Brasil. Métodos: survey realizado de maio a outubro de 2020 com 436 profissionais de saúde atuantes na linha de frente da Covid-19. Utilizaram-se análises descritivas e foi estimado um modelo de equações estruturais a partir de uma análise fatorial exploratória. Resultados: a percepção dos profissionais de saúde para contrair Covid-19 foi considerada média a muito elevada para 72% dos respondentes. No modelo de equações estruturais, o conhecimento do tratamento da Covid-19, preparo dos profissionais de saúde para atuação e a segurança no protocolo institucional em conjunto à confiança em protocolos oficiais e informações divulgadas por mídias sociais, impressa e televisiva influenciaram a autoconfiança para o enfrentamento da pandemia (P<0,05). Essa autoconfiança juntamente com o sexo masculino foram determinantes significativos (P<0,001) para a percepção da possibilidade da vir a se contaminar. Conclusão: este estudo poderá contribuir para a realização de estratégias, políticas públicas e diretrizes que impactem na melhoria da autoconfiança e na proteção dos profissionais de saúde frente a sua atuação na pandemia da Covid-19.


Assuntos
Humanos , Adulto , Pessoa de Meia-Idade , Riscos Ocupacionais , Saúde Ocupacional , Infecções por Coronavirus , Pandemias , Equipamento de Proteção Individual
17.
Rev. eletrônica enferm ; 23: 1-13, 2021.
Artigo em Inglês, Português | BDENF - Enfermagem, LILACS | ID: biblio-1253784

RESUMO

Objetivo: Identificar na prática clínica gaps que interferem na efetividade do processamento endoscópico. Método: Revisão integrativa de artigos publicados entre 2008­2020, identificados em bases de dados por meio de descritores controlados em Ciências da Saúde, adotando-se a estratégia PICO. Os gaps identificados foram classificados segundo nível de evidência (IA, IB, IC, II). Resultados: Foram encontrados 18 artigos registrando 64 gaps, 26,6% no nível de evidência IA e 40,6% IB, predominando: ausência/inadequação da secagem (55,5%), limpeza manual sem escovação dos canais/escovas inapropriadas (50%), omissão do teste de vedação (38,8%), inadequações no armazenamento (33,3%) e no uso da solução desinfetante (27,7%), tempo de imersão ou monitorização da concentração mínima eficaz, ausência de pré-limpeza (16,6%), transporte incorreto para a sala de processamento (11,1%). Conclusão: As diretrizes fortemente recomendadas por entidades internacionais e nacional têm sido descumpridas, representando aspectos críticos no processamento dos endoscópios que implicam em potenciais falhas na segurança do paciente.


Objective: This paper aimed to identify gaps in clinical practice that interfere with the effectiveness of endoscopic processing. Method: Integrative review of articles published between 2008 and 2020, identified in databases through controlled descriptors in Health Sciences, adopting the PICO strategy. The identified gaps were classified according to the level of evidence (IA, IB, IC, II). Results: Eighteen articles were found, recording 64 gaps, 26.6% at the level of evidence IA and 40.6% IB, predominating: absence/inadequate drying (55.5%), manual cleaning without brushing the inappropriate channels/brushes (50%), omission of the sealing test (38.8%), inadequate storage (33.3%) and use of the disinfectant solution (27.7%), time of immersion or monitoring of the minimum effective concentration, absence of pre-cleaning (16.6%), incorrect transportation to the processing room (11.1%). Conclusion: It was concluded that guidelines strongly recommended by international and national entities have been breached, representing critical aspects in the processing of endoscopes that imply potential failures in patient safety.


Assuntos
Controle de Infecções , Endoscópios Gastrointestinais , Desinfecção
18.
Rev. bras. enferm ; Rev. bras. enferm;74(3): e20200759, 2021. graf
Artigo em Inglês | LILACS-Express | LILACS, BDENF - Enfermagem | ID: biblio-1288354

RESUMO

ABSTRACT Objectives: to evaluate the microbial load and adherence of Escherichia coli in different areas of the surgical instrument surface exposed to experimental contamination over time. Methods: experimental study in which fragments of crile forceps (serrated, rod and rack) were contaminated by immersion in Tryptic Soy Broth, containing 106 CFU/mL of E. coli, for 1, 2, 4, 6, 8, 12 and 24 hours. Microbial load and bacterial adherence were evaluated using microbiological culture and scanning electron microscopy, respectively. Results: there was an increase in the microbial load on the surgical instrument, proportional to the contamination interval, ranging from 102 after 1 hour to 105 CFU/cm2 in 24 hours. The presence of exopolysaccharide was detected after two hours of contamination. Conclusions: microbial load and adhesion of E. coli increased over time, reaching 105 CFU/cm2 after 24 hours of contamination, starting biofilm formation after two hours.


RESUMEN Objetivos: evaluar la carga microbiana y adherencia de Escherichia coli en diferentes áreas de la superficie de instrumento quirúrgico expuesto a la contaminación experimental a lo largo del tiempo. Métodos: estudio experimental en que fragmentos de tenacillas quirúrgicas (sierra, asta y cremallera), contaminados por inmersión en Tryptic Soy Broth, conteniendo 106 UFC/mL de E. coli, por 1, 2, 4, 6, 8, 12 y 24 horas. La carga microbiana y la adherencia bacteriana evaluadas con uso de cultivo y microscopia electrónica de barredura, respectivamente Resultados: verificó aumento de la carga microbiana en el instrumento quirúrgico, proporcional al intervalo de contaminación, variando de 102 tras 1 hora a 105 UFC/cm2 en 24 horas. La presencia de polisacárido detectada tras 2 horas de contaminación. Conclusiones: carga microbiana y adherencia de E. coli aumentaron a lo largo del tiempo, atingiendo 105 UFC/cm2 tras 24 horas de contaminación, iniciándose formación de biopelícula tras 2 horas.


RESUMO Objetivos: avaliar a carga microbiana e a aderência de Escherichia coli em diferentes áreas da superfície de instrumento cirúrgico exposto à contaminação experimental ao longo do tempo. Métodos: estudo experimental em que fragmentos de pinças crile (serrilha, haste e cremalheira) foram contaminados por imersão em Tryptic Soy Broth, contendo 106 UFC/mL de E. coli, por 1, 2, 4, 6, 8, 12 e 24 horas. A carga microbiana e a aderência bacteriana foram avaliadas com uso de cultura microbiológica e microscopia eletrônica de varredura, respectivamente. Resultados: verificou-se aumento da carga microbiana no instrumento cirúrgico, proporcional ao intervalo de contaminação, variando de 102 após 1 hora a 105 UFC/cm2 em 24 horas. A presença de exapolissacarídeo foi detectada após 2 horas de contaminação. Conclusões: carga microbiana e aderência de E. coli aumentaram ao longo do tempo, atingindo 105 UFC/cm2 após 24 horas de contaminação, iniciandose formação de biofilme após 2 horas.

19.
Texto & contexto enferm ; 29: e20200106, Jan.-Dec. 2020. tab, graf
Artigo em Inglês | LILACS, BDENF - Enfermagem | ID: biblio-1101977

RESUMO

ABSTRACT Objective: to analyze the COVID-19 pandemic and what we have (re)learned from the world experience of adopting prevention measures recommended by the World Health Organization as well as the epidemiological overview in the world, in Latin America and in Brazil. Results: the World Health Organization has pointed out that the path to reduce the speed of circulation of the virus, control and decrease in the number of cases and deaths resulting from this pandemic can only be accomplished with mass adoption of fundamental measures that include hand hygiene, alcohol gel use, cough etiquette, cleaning surfaces, avoiding agglomerations and social distancing. The epidemiological curve of the disease clearly shows the devastating proportions in Italy, Spain and the United States, surpassing China in death records, due to the delay in adopting the aforementioned measures. In Brazil, the rapid progression in relation to the world and Latin America points to an important increase in the number of cases. Conclusion: this is possibly the most serious pandemic in recent human history, and its course can be influenced by the rigor in adopting individual and collective behavioral measures.


RESUMEN Objetivo: analizar la pandemia de COVID-19 y lo que hemos (re)aprendido de la experiencia mundial para la adopción de las medidas de prevención recomendadas por la Organización Mundial de la Salud, así como el panorama epidemiológico en el mundo, en América Latina y en Brasil. Resultados: la Organización Mundial de la Salud ha señalado que el camino hacia la reducción de la velocidad de circulación del virus, el control y la reducción del número de casos y muertes resultantes de esta pandemia solo se puede lograr con la adopción masiva de medidas fundamentales que incluyan la higiene de las manos, uso de alcohol en gel, etiqueta respiratoria, limpieza de superficies, evitando hacinamiento y distancia social. La curva epidemiológica de la enfermedad muestra claramente las proporciones devastadoras en Italia, España y Estados Unidos, superando a China en los registros de defunciones, debido a la demora en la adopción de estas medidas. En Brasil, la rápida progresión en relación con el mundo y América Latina apunta a un aumento importante en el número de casos. Conclusión: esta pandemia es posiblemente la más grave en la historia humana reciente y su curso puede verse influenciado por el rigor en la adopción de medidas de comportamiento individuales y colectivas.


RESUMO Objetivo: analisar a pandemia da Covid-19 e o que temos (re)aprendido com a experiência mundial para adoção das medidas de prevenção preconizadas pela Organização Mundial de Saúde bem como o panorama epidemiológico no mundo, na América Latina e no Brasil. Resultados: a Organização Mundial de Saúde tem apontado que o caminho para a redução da velocidade de circulação do vírus, o controle e queda do número de casos e óbitos decorrentes dessa pandemia só poderá ser alcançado com adoção em massa de medidas fundamentais que incluem higienização das mãos, uso do álcool em gel, etiqueta respiratória, limpeza de superfícies, evitar aglomerações e distanciamento social. A curva epidemiológica da doença mostra claramente as proporções devastadoras na Itália, Espanha e nos Estados Unidos, superando a China em registros de óbitos, devido ao atraso na adoção dessas medidas. No Brasil, a progressão rápida em relação ao mundo e à América Latina aponta um importante aumento do número de casos. Conclusão: essa pandemia possivelmente é a mais grave da história recente da humanidade e seu curso pode ser influenciado pelo rigor na adoção de medidas comportamentais individuais e coletivas.


Assuntos
Humanos , Infecções por Coronavirus , Prevenção de Doenças , Pandemias , Equipamento de Proteção Individual , Betacoronavirus , Isolamento de Pacientes , Distância Psicológica , Comportamento , Educação em Saúde
20.
Rev Lat Am Enfermagem ; 27: e3211, 2019.
Artigo em Inglês, Português, Espanhol | MEDLINE | ID: mdl-31826156

RESUMO

OBJECTIVE: to evaluate the potential contamination of enzymatic detergent from its reuse and to identify the microbiological profile in the solution used to clean gastrointestinal endoscopic devices. METHOD: cross-sectional study based on microbiological analysis of 76 aliquots of 19 different enzymatic detergent solutions used to clean endoscopic devices. The aliquots were homogenized, subjected to Millipore® 0.45 µm membrane filtration and the presumptive identification of microorganisms was performed by biochemical-physiological methods according to previously established specific bacterial groups that are of clinical and epidemiological relevance. RESULTS: the mean values, as well as the standard deviation and the median, of the enzymatic detergent microbial load increased as the solution was reused. There was a significant difference between the means of after first use and after fifth reuse. A total of 97 microorganisms were identified, with predominance of the coagulase-negative Staphylococcus, Pseudomonas spp., Klebsiella spp., Enterobacter spp. genus, and Escherichia coli species. CONCLUSION: the reuse of the enzymatic detergent solution is a risk to the safe processing of endoscopic devices, evidenced by its contamination with pathogenic potential microorganisms, since the enzymatic detergent has no bactericidal property and can contribute as an important source for outbreaks in patients under such procedures.


Assuntos
Detergentes/efeitos adversos , Contaminação de Equipamentos , Gastroscópios/efeitos adversos , Gastroscópios/microbiologia , Carga Bacteriana , Estudos Transversais , Detergentes/farmacologia , Transmissão de Doença Infecciosa , Bactérias Gram-Negativas/classificação , Bactérias Gram-Negativas/isolamento & purificação , Bactérias Gram-Positivas/classificação , Bactérias Gram-Positivas/isolamento & purificação , Humanos , Controle de Infecções
SELEÇÃO DE REFERÊNCIAS