Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Cardiothorac Vasc Anesth ; 38(3): 717-723, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38212185

RESUMO

OBJECTIVES: In a subset of patients with COVID-19 acute respiratory distress syndrome (ARDS), there is a need for extracorporeal membrane oxygenation (ECMO) for pulmonary support. The primary extracorporeal support tool for severe COVID-19 ARDS is venovenous (VV) ECMO; however, after hypoxemic respiratory failure resolves, many patients experience refractory residual hypercarbic respiratory failure. Extracorporeal carbon dioxide removal (ECCO2R) for isolated hypercarbic type II respiratory failure can be used in select cases to deescalate patients from VV ECMO while the lung recovers the ability to exchange CO2. The objective of this study was to describe the authors' experience in using ECCO2R as a bridge from VV ECMO. DESIGN: Hemolung Respiratory Assist System (RAS) is a commercially available (ECCO2R) device, and the United States Food and Drug Administration accelerated its use under its Emergency Use Authorization for the treatment of refractory hypercarbic respiratory failure in COVID-19-induced ARDS. This created an environment in which selected and targeted mechanical circulatory support therapy for refractory hypercarbic respiratory failure could be addressed. This retrospective study describes the application of Hemolung RAS as a VV ECMO deescalation platform to treat refractory hypercarbic respiratory failure after the resolution of hypoxemic COVID-19 ARDS. SETTING: A quaternary-care academic medical center, single institution. PARTICIPANTS: Patients with refractory hypercarbic respiratory failure after COVID-19 ARDS who were previously supported with VV ECMO. MEASUREMENTS AND MAIN RESULTS: Twenty-one patients were placed on ECCO2R after VV ECMO for COVID-19 ARDS. Seventeen patients successfully were transitioned to ECCO2R and then decannulated; 3 patients required reescalation to VV ECMO secondary to hypercapnic respiratory failure, and 1 patient died while on ECCO2R. Five (23.8%) of the 21 patients were transitioned off of VV ECMO to ECCO2R, with a compliance of <20 (mL/cmH2O). Of these patients, 3 with low compliance were reescalated to VV ECMO. CONCLUSIONS: Extracorporeal carbon dioxide removal can be used to continue supportive methods for patients with refractory type 2 hypercarbic respiratory failure after COVID-19 ARDS for patients previously on VV ECMO. Patients with low compliance have a higher rate of reescalation to VV ECMO.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Síndrome do Desconforto Respiratório , Insuficiência Respiratória , Humanos , Oxigenação por Membrana Extracorpórea/métodos , Dióxido de Carbono , Estudos Retrospectivos , COVID-19/complicações , COVID-19/terapia , Síndrome do Desconforto Respiratório/terapia , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/terapia
2.
JTCVS Tech ; 18: 65-73, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37096080

RESUMO

Objectives: Percutaneous pulmonary artery cannulas, used as inflow for left ventricular venting or as outflow for right ventricular mechanical circulatory support, are easily and rapidly deployable with transesophageal and fluoroscopic guidance. Methods: We chose to review our institutional and technical experience with all right atrium to pulmonary artery cannulations. Results: Based on the review, we describe 6 right atrium to pulmonary artery cannulation strategies. They are divided into total right ventricular assist support, partial right ventricular assist support, and left ventricular venting. A single limb cannula or a dual lumen cannula can be used for right ventricular support. Conclusions: In the right ventricular assist device configuration, percutaneous cannulation may prove beneficial in cases of isolated right ventricular failure. Conversely, pulmonary artery cannulation can be used for left ventricular venting as drainage to a cardiopulmonary bypass or extracorporeal membrane oxygenation circuit. This article can be used as a reference for the technical aspects of cannulation, decision-making in patient selection, and management of patients in these clinical scenarios.

3.
ASAIO J ; 69(8): e391-e396, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-36867841

RESUMO

Extracorporeal membrane oxygenation (ECMO) is used in cases of severe respiratory failure refractory to medical management. Use of ECMO is increasing, along with new cannulation strategies including oxygenated right ventricular assist devices (oxy-RVADs). Multiple dual lumen cannulas are now available, which increase the potential for patient mobility and decrease the number of vascular access sites. However, dual lumen, single cannula flow can be limited by adequate inflow, requiring the need for an additional inflow cannula to meet patient demands. This cannula configuration may result in differential flows in the inflow and outflow limbs and altered flow dynamics, increasing the risk of intracannula thrombus. We describe a series of four patients treated with oxy-RVAD for COVID-19-associated respiratory failure complicated by dual lumen ProtekDuo intracannula thrombus.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Insuficiência Respiratória , Trombose , Humanos , Cânula , Oxigenação por Membrana Extracorpórea/efeitos adversos , COVID-19/complicações , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/terapia , Trombose/etiologia
4.
J Cardiothorac Vasc Anesth ; 36(6): 1662-1669, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34218997

RESUMO

OBJECTIVE: To assess societal preferences regarding allocation of extracorporeal membrane oxygenation (ECMO) as a rescue option for select patients with coronavirus disease 2019 (COVID-19). DESIGN: Cross-sectional survey of a nationally representative sample. SETTING: Amazon Mechanical Turk platform. PARTICIPANTS: In total, responses from 1,041 members of Amazon Mechanical Turk crowd-sourcing platform were included. Participants were 37.9 ± 12.6 years old, generally white (65%), and college-educated (66.1%). Many reported working in a healthcare setting (22.5%) and having a friend or family member who was admitted to the hospital (43.8%) or died from COVID-19 (29.9%). MEASUREMENTS AND MAIN RESULTS: Although most reported an unwillingness to stay on ECMO for >one week without signs of recovery, participants were highly supportive of ECMO utilization as a life-preserving technique on a policy level. The majority (96.7%) advocated for continued use of ECMO to treat COVID patients during periods of resource scarcity but would prioritize those with highest likelihood of recovery (50%) followed by those who were sickest regardless of survival chances (31.7%). Patients >40 years old were more likely to prefer distributing ECMO on a first-come first-served basis (21.5% v 13.3%, p < 0.05). CONCLUSION: Even though participants expressed hesitation regarding ECMO in personal circumstances, they were uniformly in support of using ECMO to treat COVID patients at a policy level for others who might need it, even in the setting of severe scarcity.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Adulto , COVID-19/terapia , Estudos Transversais , Humanos , Pessoa de Meia-Idade , Opinião Pública , SARS-CoV-2
5.
J Cardiothorac Vasc Anesth ; 34(11): 3006-3012, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32828653

RESUMO

OBJECTIVE: Anticoagulation may be a challenge in coronavirus disease 2019 (COVID-19) extracorporeal membrane oxygenation due to endothelial injury and dysregulation of coagulation, which may increase the risk of thrombotic and bleeding complications. This report was created to describe the authors' single institutional experience, with emphasis on the high rate of intracranial hemorrhage for the first 10 patients with COVID-19 placed on venovenous extracorporeal membrane oxygenation (VV ECMO). DESIGN: Case series, retrospective analysis. SETTING: Single institution. PARTICIPANTS: Ten patients. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Patient characteristics, mortality, stroke rate, and length of stay data were collected in all patients. In addition, laboratory values of D-dimer and C-reactive protein and standard measurements of prothrombin and activated partial thromboplastin time were collected on all patients. Ten patients, each confirmed with COVID-19 via reverse transcription-polymerase chain reaction, were supported on VV ECMO for acute respiratory distress syndrome (ARDS) for a mean duration of 9.4 ± 7 days. Four of 10 patients had hemorrhagic strokes, 3 of which resulted in death. At 30 days after initiation of VV ECMO, a total of 7 survivors included 6 patients discharged from the hospital and 1 patient who remained in the intensive care unit. CONCLUSIONS: In this small study of 10 patients, intracranial hemorrhage was a common complication, resulting in a high rate of death. The authors urge caution in the anticoagulation management of VV ECMO for patients with severe ARDS and COVID-19 patients. Close monitoring of all hematologic parameters is recommended during ECMO support while awaiting larger, multicenter studies to examine the best practice.


Assuntos
Anticoagulantes/administração & dosagem , Betacoronavirus , Infecções por Coronavirus/terapia , Oxigenação por Membrana Extracorpórea/efeitos adversos , Hemorragias Intracranianas/etiologia , Pneumonia Viral/terapia , Anticoagulantes/efeitos adversos , COVID-19 , Infecções por Coronavirus/epidemiologia , Oxigenação por Membrana Extracorpórea/métodos , Feminino , Seguimentos , Humanos , Hemorragias Intracranianas/diagnóstico , Masculino , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/epidemiologia , Estudos Retrospectivos , SARS-CoV-2
6.
J Thorac Cardiovasc Surg ; 156(4): 1643-1651.e7, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29807773

RESUMO

OBJECTIVES: The PediaFlow (HeartWare International, Inc, Framingham, Mass) is a miniature, implantable, rotodynamic, fully magnetically levitated, continuous-flow pediatric ventricular assist device. The fourth-generation PediaFlow was evaluated in vitro and in vivo to characterize performance and biocompatibility. METHODS: Supported by 2 National Heart, Lung, and Blood Institute contract initiatives to address the limited options available for pediatric patients with congenital or acquired cardiac disease, the PediaFlow was developed with the intent to provide chronic cardiac support for infants as small as 3 kg. The University of Pittsburgh-led Consortium evaluated fourth-generation PediaFlow prototypes both in vitro and within a preclinical ovine model (n = 11). The latter experiments led to multiple redesigns of the inflow cannula and outflow graft, resulting in the implantable design represented in the most recent implants (n = 2). RESULTS: With more than a decade of extensive computational and experimental efforts spanning 4 device iterations, the AA battery-sized fourth-generation PediaFlow has an operating range of 0.5 to 1.5 L/min with minimal hemolysis in vitro and excellent hemocompatibility (eg, minimal hemolysis and platelet activation) in vivo. The pump and finalized accompanying implantable components demonstrated preclinical hemodynamics suitable for the intended pediatric application for up to 60 days. CONCLUSIONS: Designated a Humanitarian Use Device for "mechanical circulatory support in neonates, infants, and toddlers weighing up to 20 kg as a bridge to transplant, a bridge to other therapeutic intervention such as surgery, or as a bridge to recovery" by the Food and Drug Administration, these initial results document the biocompatibility and potential of the fourth-generation PediaFlow design to provide chronic pediatric cardiac support.


Assuntos
Fontes de Energia Elétrica , Insuficiência Cardíaca/terapia , Coração Auxiliar , Hemodinâmica , Implantação de Prótese/instrumentação , Função Ventricular , Fatores Etários , Animais , Animais Recém-Nascidos , Peso Corporal , Pré-Escolar , Fontes de Energia Elétrica/efeitos adversos , Insuficiência Cardíaca/fisiopatologia , Coração Auxiliar/efeitos adversos , Hemólise , Humanos , Lactente , Recém-Nascido , Teste de Materiais , Miniaturização , Desenho de Prótese , Carneiro Doméstico
7.
Cardiovasc Eng Technol ; 2(4): 263-275, 2011 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-23494160

RESUMO

The PediVAS blood pump is a magnetically levitated centrifugal pump designed for pediatric bridge-to-decision or bridge-to-recovery in pediatric patients from 3-20kg in weight. In preparation for submission of an investigational device exemption (IDE) application, we completed a final six-animal series of pre-clinical studies. The studies were conducted under controlled conditions as prescribed by the recently released FDA guidance document for animal studies for cardiovascular devices. Three 30-day chronic left ventricular support studies were completed in a juvenile lamb model to demonstrate the safety and hemocompatibility of the PediVAS pump. Three additional 8-hour acute biventricular support studies were performed to demonstrate the feasibility of this approach from a hemodynamic and systems standpoint. It is estimated that 50% of pediatric patients who require left ventricular support also require right ventricular support. All studies were successfully completed without complications, device malfunctions, or adverse events. End-organ function was normal for the chronic studies. We noted small surface lesions on one kidney from each chronic study as well as the presence of ring thrombus on connectors, as expected for these types of studies in animal models. The strategy and challenges imposed by performing a controlled cardiovascular device study in a juvenile lamb model are discussed. We believe that these successful implants demonstrate safety and performance for the PediVAS device for support of an IDE application to initiate human clinical trials and provide a roadmap for other researchers.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA