1.
Artif Organs ; 35(5): 454-8, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21595711

RESUMO

This article presents improvement on a physical cardiovascular simulator (PCS) system. Intraventricular pressure versus intraventricular volume (PxV) loop was obtained to evaluate performance of a pulsatile chamber mimicking the human left ventricle. PxV loop shows heart contractility and is normally used to evaluate heart performance. In many heart diseases, the stroke volume decreases because of low heart contractility. This pathological situation must be simulated by the PCS in order to evaluate the assistance provided by a ventricular assist device (VAD). The PCS system is automatically controlled by a computer and is an auxiliary tool for VAD control strategies development. This PCS system is according to a Windkessel model where lumped parameters are used for cardiovascular system analysis. Peripheral resistance, arteries compliance, and fluid inertance are simulated. The simulator has an actuator with a roller screw and brushless direct current motor, and the stroke volume is regulated by the actuator displacement. Internal pressure and volume measurements are monitored to obtain the PxV loop. Left chamber internal pressure is directly obtained by pressure transducer; however, internal volume has been obtained indirectly by using a linear variable differential transformer, which senses the diaphragm displacement. Correlations between the internal volume and diaphragm position are made. LabVIEW integrates these signals and shows the pressure versus internal volume loop. The results that have been obtained from the PCS system show PxV loops at different ventricle elastances, making possible the simulation of pathological situations. A preliminary test with a pulsatile VAD attached to PCS system was made.


Assuntos
Cardiopatias/fisiopatologia , Hemodinâmica , Modelos Cardiovasculares , Volume Sistólico , Função Ventricular Esquerda , Pressão Ventricular , Complacência (Medida de Distensibilidade) , Cardiopatias/terapia , Coração Auxiliar , Humanos , Teste de Materiais , Microcomputadores , Contração Miocárdica , Desenho de Prótese , Fluxo Pulsátil , Fatores de Tempo , Transdutores de Pressão , Resistência Vascular
2.
Artif Organs ; 32(04): 355-359, 20080400.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1060068

RESUMO

This article presents a back-electromotive force (BEMF)-based technique of detection for sensorless brushless direct current motor (BLDCM) drivers. The BLDCM has been chosen as the energy converter in rotary or pulsatile blood pumps that use electrical motors for pumping. However, in order to operate properly, the BLDCM driver needs to know the shaft position. Usually, that information is obtained through a set of Hall sensors assembled close to the rotor and connected to the electronic controller by wires. Sometimes, a large distance between the motor and controller makes the system susceptible to interference on the sensor signal because of winding current switching. Thus, the goal of the sensorless technique presented in this study is to avoid this problem. First, the operation of BLDCM was evaluated on the electronic simulator PSpice. Then, a BEMF detector circuitry was assembled in our laboratories. For the tests, a sensordependent system was assembled where the direct comparison between the Hall sensors signals and the detected signals was performed. The obtained results showed that the output sensorless detector signals are very similar to the Hall signals at speeds of more than 2500 rpm. Therefore, the sensorless technique is recommended as a responsible or redundant system to be used in rotary blood pumps.


Assuntos
Coração Artificial
3.
Artif Organs ; 32(4): 355-9, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18370953

RESUMO

This article presents a back-electromotive force (BEMF)-based technique of detection for sensorless brushless direct current motor (BLDCM) drivers. The BLDCM has been chosen as the energy converter in rotary or pulsatile blood pumps that use electrical motors for pumping. However, in order to operate properly, the BLDCM driver needs to know the shaft position. Usually, that information is obtained through a set of Hall sensors assembled close to the rotor and connected to the electronic controller by wires. Sometimes, a large distance between the motor and controller makes the system susceptible to interference on the sensor signal because of winding current switching. Thus, the goal of the sensorless technique presented in this study is to avoid this problem. First, the operation of BLDCM was evaluated on the electronic simulator PSpice. Then, a BEMF detector circuitry was assembled in our laboratories. For the tests, a sensor-dependent system was assembled where the direct comparison between the Hall sensors signals and the detected signals was performed. The obtained results showed that the output sensorless detector signals are very similar to the Hall signals at speeds of more than 2500 rpm. Therefore, the sensorless technique is recommended as a responsible or redundant system to be used in rotary blood pumps.


Assuntos
Coração Auxiliar , Algoritmos , Simulação por Computador , Desenho de Equipamento , Hemorreologia , Modelos Cardiovasculares , Fluxo Pulsátil , Processamento de Sinais Assistido por Computador , Torque
4.
Artigo em Inglês | MEDLINE | ID: mdl-19163226

RESUMO

Low Noise Electrocardiogram (ECG) has been widely used for heart disease diagnosis. The anisotropic median-diffusion is the filter obtained by intercalating a median filtering in each diffusion step. We propose to use anisotropic median-diffusion to filter noisy ECG signals. We describe how to estimate appropriate parameters of the proposed filter. We validate our method using ECG signals from the MIT-BIH databases (many of them with premature ventricular contraction) and compare our method with other filtering methods. Experiments show that the proposed technique can effectively remove the noise without changing the instants and amplitudes of events, as well as preserving the morphologies of ECG signals in sections of the QRS complex.


Assuntos
Anisotropia , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Algoritmos , Artefatos , Bases de Dados Factuais , Desenho de Equipamento , Ventrículos do Coração/patologia , Humanos , Processamento de Imagem Assistida por Computador , Modelos Estatísticos , Contração Muscular , Processamento de Sinais Assistido por Computador , Software , Técnica de Subtração