Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Pediatr ; 182: 382-384, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28088392

RESUMO

It has been reported in the 3 Benefits of Oxygen Saturation Targeting (BOOST-II) trials that changes in oximeter calibration software resulted in clearer separation between the oxygen saturations in the two trial target groups. A revised analysis of the published BOOST-II data does not support this conclusion.


Assuntos
Hipóxia/diagnóstico , Recém-Nascido Prematuro , Oximetria/instrumentação , Consumo de Oxigênio/fisiologia , Software , Calibragem , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Humanos , Recém-Nascido , Masculino , Oximetria/métodos , Oxigênio/sangue , Ensaios Clínicos Controlados Aleatórios como Assunto , Sensibilidade e Especificidade
2.
J Pediatr ; 165(4): 666-71.e2, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24973289

RESUMO

OBJECTIVE: To compare oxygen saturations as displayed to caregivers on offset pulse oximeters in the 2 groups of the Canadian Oxygen Trial. STUDY DESIGN: In 5 double-blind randomized trials of oxygen saturation targeting, displayed saturations between 88% and 92% were offset by 3% above or below the true values but returned to true values below 84% and above 96%. During the transition, displayed values remained static at 96% in the lower and at 84% in the higher target group during a 3% change in true saturations. In contrast, displayed values changed rapidly from 88% to 84% in the lower and from 92% to 96% in the higher target group during a 1% change in true saturations. We plotted the distributions of median displayed saturations on days with >12 hours of supplemental oxygen in 1075 Canadian Oxygen Trial participants to reconstruct what caregivers observed at the bedside. RESULTS: The oximeter masking algorithm was associated with an increase in both stability and instability of displayed saturations that occurred during the transition between offset and true displayed values at opposite ends of the 2 target ranges. Caregivers maintained saturations at lower displayed values in the higher than in the lower target group. This differential management reduced the separation between the median true saturations in the 2 groups by approximately 3.5%. CONCLUSIONS: The design of the oximeter masking algorithm may have contributed to the smaller-than-expected separation between true saturations in the 2 study groups of recent saturation targeting trials in extremely preterm infants.


Assuntos
Oximetria/métodos , Oxigenoterapia/métodos , Oxigênio/administração & dosagem , Algoritmos , Calibragem , Canadá , Cuidadores , Método Duplo-Cego , Humanos , Lactente , Lactente Extremamente Prematuro , Recém-Nascido , Monitorização Fisiológica/métodos , Reprodutibilidade dos Testes , Software , Tensoativos/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA