1.
Pediatr Crit Care Med ; 16(6): 522-8, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25850863

RESUMO

OBJECTIVE: The use of ventricular assist devices has increased dramatically in adult heart failure patients. However, the overall use, outcome, comorbidities, and resource utilization of ventricular assist devices in pediatric patients have not been well described. We sought to demonstrate that the use of ventricular assist devices in pediatric patients has increased over time and that mortality has decreased. DESIGN: A retrospective study of the Pediatric Health Information System database was performed for patients 20 years old or younger undergoing ventricular assist device placement from 2000 to 2010. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Four hundred seventy-five pediatric patients were implanted with ventricular assist devices during the study period: 69 in 2000-2003 (era 1), 135 in 2004-2006 (era 2), and 271 in 2007-2010 (era 3). Median age at ventricular assist device implantation was 6.0 years (interquartile range, 0.5-13.8), and the proportion of children who were 1-12 years old increased from 29% in era 1 to 47% in era 3 (p = 0.002). The majority of patients had a diagnosis of cardiomyopathy; this increased from 52% in era 1 to 72% in era 3 (p = 0.003). Comorbidities included arrhythmias (48%), pulmonary hypertension (16%), acute renal failure (34%), cerebrovascular disease (28%), and sepsis/systemic inflammatory response syndrome (34%). Two hundred forty-seven patients (52%) underwent heart transplantation and 327 (69%) survived to hospital discharge. Hospital mortality decreased from 42% in era 1 to 25% in era 3 (p = 0.004). Median hospital length of stay increased (37 d [interquartile range, 12-64 d] in era 1 vs 69 d [interquartile range, 35-130] in era 3; p < 0.001) and median adjusted hospital charges increased ($630,630 [interquartile range, $227,052-$853,318] in era 1 vs $1,577,983 [interquartile range, $874,463-$2,280,435] in era 3; p < 0.001). Factors associated with increased mortality include age less than 1 year (odds ratio, 2.04; 95% CI, 1.01-3.83), acute renal failure (odds ratio, 2.1; 95% CI, 1.26-3.65), cerebrovascular disease (odds ratio, 2.1; 95% CI, 1.25-3.62), and extracorporeal membrane oxygenation (odds ratio, 3.16; 95% CI, 1.79-5.60). Ventricular assist device placement in era 3 (odds ratio, 0.3; 95% CI, 0.15-0.57) and a diagnosis of cardiomyopathy (odds ratio, 0.5; 95% CI, 0.32-0.84), were associated with decreased mortality. Large-volume centers had lower mortality (odds ratio, 0.55; 95% CI, 0.34-0.88), lower use of extracorporeal membrane oxygenation, and higher charges. CONCLUSIONS: The use of ventricular assist devices and survival after ventricular assist device placement in pediatric patients have increased over time, with a concomitant increase in resource utilization. Age under 1 year, certain noncardiac morbidities, and the use of extracorporeal membrane oxygenation are associated with worse outcomes. Lower mortality was seen at larger volume ventricular assist device centers.


Assuntos
Cardiomiopatias/terapia , Coração Auxiliar/estatística & dados numéricos , Preços Hospitalares/tendências , Mortalidade Hospitalar/tendências , Hospitais Pediátricos/estatística & dados numéricos , Injúria Renal Aguda/mortalidade , Adolescente , Fatores Etários , Cardiomiopatias/mortalidade , Transtornos Cerebrovasculares/mortalidade , Criança , Pré-Escolar , Oxigenação por Membrana Extracorpórea/mortalidade , Oxigenação por Membrana Extracorpórea/estatística & dados numéricos , Transplante de Coração , Coração Auxiliar/efeitos adversos , Coração Auxiliar/tendências , Hospitais com Alto Volume de Atendimentos/estatística & dados numéricos , Humanos , Lactente , Tempo de Internação/tendências , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Adulto Jovem
2.
J Pediatr ; 154(5): 672-6, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19167721

RESUMO

OBJECTIVE: To test the hypothesis that pediatric residents would have shorter time to attempted defibrillation using automated external defibrillators (AEDs) compared with manual defibrillators (MDs). STUDY DESIGN: A prospective, randomized, controlled trial of AEDs versus MDs was performed. Pediatric residents responded to a simulated in-hospital ventricular fibrillation cardiac arrest and were randomized to using either an AED or MD. The primary end point was time to attempted defibrillation. RESULTS: Sixty residents, 21 (35%) interns, were randomized to 2 groups (AED = 30, MD = 30). Residents randomized to the AED group had a significantly shorter time to attempted defibrillation [median, 60 seconds (interquartile range, 53 to 71 seconds)] compared with those randomized to the MD group [median, 103 seconds (interquartile range, 68 to 288 seconds)] (P < .001). All residents in the AED group attempted defibrillation at <5 minutes compared with 23 (77%) in the MD group (P = .01). CONCLUSIONS: AEDs improve the time to attempted defibrillation by pediatric residents in simulated cardiac arrests. Further studies are needed to help determine the role of AEDs in pediatric in-hospital cardiac arrests.


Assuntos
Desfibriladores , Cardioversão Elétrica/métodos , Parada Cardíaca/terapia , Desenho de Equipamento , Humanos , Internato e Residência , Manequins , Pediatria/educação , Estudos Prospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA