Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Diabetes Sci Technol ; 17(4): 1008-1015, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35549733

RESUMO

BACKGROUND: The first two studies of an artificial pancreas (AP) system carried out in Latin America took place in 2016 (phase 1) and 2017 (phase 2). They evaluated a hybrid algorithm from the University of Virginia (UVA) and the automatic regulation of glucose (ARG) algorithm in an inpatient setting using an AP platform developed by the UVA. The ARG algorithm does not require carbohydrate (CHO) counting and does not deliver meal priming insulin boluses. Here, the first outpatient trial of the ARG algorithm using an own AP platform and doubling the duration of previous phases is presented. METHOD: Phase 3 involved the evaluation of the ARG algorithm in five adult participants (n = 5) during 72 hours of closed-loop (CL) and 72 hours of open-loop (OL) control in an outpatient setting. This trial was performed with an own AP and remote monitoring platform developed from open-source resources, called InsuMate. The meals tested ranged its CHO content from 38 to 120 g and included challenging meals like pasta. Also, the participants performed mild exercise (3-5 km walks) daily. The clinical trial is registered in ClinicalTrials.gov with identifier: NCT04793165. RESULTS: The ARG algorithm showed an improvement in the time in hyperglycemia (52.2% [16.3%] OL vs 48.0% [15.4%] CL), time in range (46.9% [15.6%] OL vs 50.9% [14.4%] CL), and mean glucose (188.9 [25.5] mg/dl OL vs 186.2 [24.7] mg/dl CL) compared with the OL therapy. No severe hyperglycemia or hypoglycemia episodes occurred during the trial. The InsuMate platform achieved an average of more than 95% of the time in CL. CONCLUSION: The results obtained demonstrated the feasibility of outpatient full CL regulation of glucose levels involving the ARG algorithm and the InsuMate platform.


Assuntos
Diabetes Mellitus Tipo 1 , Hiperglicemia , Pâncreas Artificial , Adulto , Humanos , Algoritmos , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucose , Hiperglicemia/tratamento farmacológico , Hipoglicemiantes , Insulina , Sistemas de Infusão de Insulina , Pacientes Ambulatoriais , América do Sul
2.
ISA Trans ; 124: 225-235, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34175123

RESUMO

This work is focused on the multilevel control of the population confinement in the city of Buenos Aires and its surroundings due to the pandemic generated by the COVID-19 outbreak. The model used here is known as SEIRD and two objectives are sought: a time-varying identification of the infection rate and the inclusion of a controller. A control differential equation has been added to regulate the transitions between confinement and normal life, according to five different levels. The plasma treatment from recovered patients has also been considered in the control algorithm. Using the proposed strategy the ICU occupancy is reduced, and as a consequence, the number of deaths is also decreased.


Assuntos
COVID-19 , Argentina/epidemiologia , COVID-19/epidemiologia , COVID-19/prevenção & controle , Cidades/epidemiologia , Humanos , Pandemias/prevenção & controle
3.
J Diabetes Sci Technol ; 12(5): 914-925, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29998754

RESUMO

BACKGROUND: Emerging therapies such as closed-loop (CL) glucose control, also known as artificial pancreas (AP) systems, have shown significant improvement in type 1 diabetes mellitus (T1DM) management. However, demanding patient intervention is still required, particularly at meal times. To reduce treatment burden, the automatic regulation of glucose (ARG) algorithm mitigates postprandial glucose excursions without feedforward insulin boluses. This work assesses feasibility of this new strategy in a clinical trial. METHODS: A 36-hour pilot study was performed on five T1DM subjects to validate the ARG algorithm. Subjects wore a subcutaneous continuous glucose monitor (CGM) and an insulin pump. Insulin delivery was solely commanded by the ARG algorithm, without premeal insulin boluses. This was the first clinical trial in Latin America to validate an AP controller. RESULTS: For the total 36-hour period, results were as follows: average time of CGM readings in range 70-250 mg/dl: 88.6%, in range 70-180 mg/dl: 74.7%, <70 mg/dl: 5.8%, and <50 mg/dl: 0.8%. Results improved analyzing the final 15-hour period of this trial. In that case, the time spent in range was 70-250 mg/dl: 94.7%, in range 70-180 mg/dl: 82.6%, <70 mg/dl: 4.1%, and <50 mg/dl: 0.2%. During the last night the time spent in range was 70-250 mg/dl: 95%, in range 70-180 mg/dl: 87.7%, <70 mg/dl: 5.0%, and <50 mg/dl: 0.0%. No severe hypoglycemia occurred. No serious adverse events were reported. CONCLUSIONS: The ARG algorithm was successfully validated in a pilot clinical trial, encouraging further tests with a larger number of patients and in outpatient settings.


Assuntos
Algoritmos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Pâncreas Artificial , Adulto , Automonitorização da Glicemia , Feminino , Humanos , Sistemas de Infusão de Insulina , América Latina , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Período Pós-Prandial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA