Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros











Intervalo de ano de publicação
2.
Anesthesiology ; 140(4): 752-764, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38207290

RESUMO

BACKGROUND: Lower fractional inspired oxygen tension (Fio2) during general anesthesia can reduce lung atelectasis. The objectives are to evaluate the effect of two Fio2 (0.4 and 1) during low positive end-expiratory pressure (PEEP) ventilation over lung perfusion distribution, volume, and regional ventilation. These variables were evaluated at two PEEP levels and unilateral lung atelectasis. METHODS: In this exploratory study, 10 healthy female piglets (32.3 ± 3.4 kg) underwent mechanical ventilation in two atelectasis models: (1) bilateral gravitational atelectasis (n = 6), induced by changes in PEEP and Fio2 in three combinations: high PEEP with low Fio2 (Fio2 = 0.4), zero PEEP (PEEP0) with low Fio2 (Fio2 = 0.4), and PEEP0 with high Fio2 (Fio2 = 1); and (2) unilateral atelectasis (n = 6), induced by left bronchial occlusion, with the left lung aerated (Fio2 = 0.21) and low aerated (Fio2 = 1; n = 5 for this step). Measurements were conducted after 10 min in each step, encompassing assessment of respiratory mechanics, oxygenation, and hemodynamics; lung ventilation and perfusion by electrical impedance tomography; and lung aeration and perfusion by computed tomography. RESULTS: During bilateral gravitational atelectasis, PEEP reduction increased atelectasis in dorsal regions, decreased respiratory compliance, and distributed lung ventilation to ventral regions with a parallel shift of perfusion to the same areas. With PEEP0, there were no differences between low and high Fio2 in respiratory compliance (23.9 ± 6.5 ml/cm H2O vs. 21.9 ± 5.0; P = 0.441), regional ventilation, and regional perfusion, despite higher lung collapse (18.6 ± 7.6% vs. 32.7 ± 14.5%; P = 0.045) with high Fio2. During unilateral lung atelectasis, the deaerated lung had a lower shunt (19.3 ± 3.6% vs. 25.3 ± 5.5%; P = 0.045) and lower computed tomography perfusion to the left lung (8.8 ± 1.8% vs. 23.8 ± 7.1%; P = 0.007). CONCLUSIONS: PEEP0 with low Fio2, compared with high Fio2, did not produce significant changes in respiratory system compliance, regional lung ventilation, and perfusion despite significantly lower lung collapse. After left bronchial occlusion, the shrinkage of the parenchyma with Fio2 = 1 enhanced hypoxic pulmonary vasoconstriction, reducing intrapulmonary shunt and perfusion of the nonventilated areas.


Assuntos
Atelectasia Pulmonar , Respiração Artificial , Animais , Feminino , Suínos , Respiração Artificial/métodos , Pulmão/diagnóstico por imagem , Medidas de Volume Pulmonar , Atelectasia Pulmonar/diagnóstico por imagem , Atelectasia Pulmonar/terapia , Perfusão , Oxigênio
3.
Ann Intensive Care ; 13(1): 131, 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38117367

RESUMO

BACKGROUND: Internal redistribution of gas, referred to as pendelluft, is a new potential mechanism of effort-dependent lung injury. Neurally-adjusted ventilatory assist (NAVA) and proportional assist ventilation (PAV +) follow the patient's respiratory effort and improve synchrony compared with pressure support ventilation (PSV). Whether these modes could prevent the development of pendelluft compared with PSV is unknown. We aimed to compare pendelluft magnitude during PAV + and NAVA versus PSV in patients with resolving acute respiratory distress syndrome (ARDS). METHODS: Patients received either NAVA, PAV + , or PSV in a crossover trial for 20-min using comparable assistance levels after controlled ventilation (> 72 h). We assessed pendelluft (the percentage of lost volume from the non-dependent lung region displaced to the dependent region during inspiration), drive (as the delta esophageal swing of the first 100 ms [ΔPes 100 ms]) and inspiratory effort (as the esophageal pressure-time product per minute [PTPmin]). We performed repeated measures analysis with post-hoc tests and mixed-effects models. RESULTS: Twenty patients mechanically ventilated for 9 [5-14] days were monitored. Despite matching for a similar tidal volume, respiratory drive and inspiratory effort were slightly higher with NAVA and PAV + compared with PSV (ΔPes 100 ms of -2.8 [-3.8--1.9] cm H2O, -3.6 [-3.9--2.4] cm H2O and -2.1 [-2.5--1.1] cm H2O, respectively, p < 0.001 for both comparisons; PTPmin of 155 [118-209] cm H2O s/min, 197 [145-269] cm H2O s/min, and 134 [93-169] cm H2O s/min, respectively, p < 0.001 for both comparisons). Pendelluft magnitude was higher in NAVA (12 ± 7%) and PAV + (13 ± 7%) compared with PSV (8 ± 6%), p < 0.001. Pendelluft magnitude was strongly associated with respiratory drive (ß = -2.771, p-value < 0.001) and inspiratory effort (ß = 0.026, p < 0.001), independent of the ventilatory mode. A higher magnitude of pendelluft in proportional modes compared with PSV existed after adjusting for PTPmin (ß = 2.606, p = 0.010 for NAVA, and ß = 3.360, p = 0.004 for PAV +), and only for PAV + when adjusted for respiratory drive (ß = 2.643, p = 0.009 for PAV +). CONCLUSIONS: Pendelluft magnitude is associated with respiratory drive and inspiratory effort. Proportional modes do not prevent its occurrence in resolving ARDS compared with PSV.

4.
Crit Care ; 27(1): 457, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-38001485

RESUMO

BACKGROUND: In the acute distress respiratory syndrome (ARDS), specific lung regions can be exposed to excessive strain due to heterogeneous disease, gravity-dependent lung collapse and injurious mechanical ventilation. Computed tomography (CT) is the gold standard for regional strain assessment. An alternative tool could be the electrical impedance tomography (EIT). We aimed to determine whether EIT-based methods can predict the dynamic relative regional strain (DRRS) between two levels of end-expiratory pressure (PEEP) in gravity-non-dependent and dependent lung regions. METHODS: Fourteen ARDS patients underwent CT and EIT acquisitions (at end-inspiratory and end-expiratory) at two levels of PEEP: a low-PEEP based on ARDS-net strategy and a high-PEEP titrated according to EIT. Three EIT-based methods for DRRS were compared to relative CT-based strain: (1) the change of the ratio between EIT ventilation and end-expiratory lung impedance in arbitrary units ([ΔZAU low-PEEP/EELIAU low-PEEP]/[ΔZAU high-PEEP/EELIAU high-PEEP]), (2) the change of ΔZ/EELI ratio calibrated to mL ([ΔZml low-PEEP/EELIml low-PEEP]/[ΔZml high-PEEP/EELIml high-PEEP]) using CT data, and (3) the relative change of ∆ZAU (∆ZAU low-PEEP/∆ZAU high-PEEP). We performed linear regressions analysis and calculated bias and limits of agreement to assess the performance of DRRS by EIT in comparison with CT. RESULTS: The DRRS assessed by (ΔZml low-PEEP/EELIml low-PEEP)/(ΔZml high-PEEP/EELIml high-PEEP) and ∆ZAU low-PEEP/∆ZAU high-PEEP showed good relationship and agreement with the CT method (R2 of 0.9050 and 0.8679, respectively, in non-dependent region; R2 of 0.8373 and 0.6588, respectively, in dependent region; biases ranging from - 0.11 to 0.51 and limits of agreement ranging from - 0.73 to 1.16 for both methods and lung regions). Conversely, DRRS based on EELIAU ([ΔZAU low-PEEP/EELIAU low-PEEP]/[ΔZAU high-PEEP/EELIAU high-PEEP]) exhibited a weak negative relationship and poor agreement with the CT method for both non-dependent and dependent regions (R2 ~ 0.3; bias of 3.11 and 2.08, and limits of agreement of - 2.13 to 8.34 and from - 1.49 to 5.64, respectively). CONCLUSION: Changes in DRRS during a PEEP trial in ARDS patients could be monitored using EIT, based on changes in ΔZmL/EELIml and ∆ZAU. The relative change ∆ZAU offers the advantage of not requiring CT data for calibration.


Assuntos
Respiração com Pressão Positiva , Síndrome do Desconforto Respiratório , Humanos , Impedância Elétrica , Respiração com Pressão Positiva/métodos , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Tomografia/métodos
5.
PLoS One ; 18(3): e0283039, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36928465

RESUMO

INTRODUCTION: General anesthesia is associated with the development of atelectasis, which may affect lung ventilation. Electrical impedance tomography (EIT) is a noninvasive imaging tool that allows monitoring in real time the topographical changes in aeration and ventilation. OBJECTIVE: To evaluate the pattern of distribution of pulmonary ventilation through EIT before and after anesthesia induction in pediatric patients without lung disease undergoing nonthoracic surgery. METHODS: This was a prospective observational study including healthy children younger than 5 years who underwent nonthoracic surgery. Monitoring was performed continuously before and throughout the surgical period. Data analysis was divided into 5 periods: induction (spontaneous breathing, SB), ventilation-5min, ventilation-30min, ventilation-late and recovery-SB. In addition to demographic data, mechanical ventilation parameters were also collected. Ventilation impedance (Delta Z) and pulmonary ventilation distribution were analyzed cycle by cycle at the 5 periods. RESULTS: Twenty patients were included, and redistribution of ventilation from the posterior to the anterior region was observed with the beginning of mechanical ventilation: on average, the percentage ventilation distribution in the dorsal region decreased from 54%(IC95%:49-60%) to 49%(IC95%:44-54%). With the restoration of spontaneous breathing, ventilation in the posterior region was restored. CONCLUSION: There were significant pulmonary changes observed during anesthesia and controlled mechanical ventilation in children younger than 5 years, mirroring the findings previously described adults. Monitoring these changes may contribute to guiding the individualized settings of the mechanical ventilator with the goal to prevent postoperative complications.


Assuntos
Respiração Artificial , Tomografia , Adulto , Humanos , Criança , Respiração Artificial/métodos , Impedância Elétrica , Tomografia/métodos , Ventilação Pulmonar , Pulmão/diagnóstico por imagem , Anestesia Geral/efeitos adversos
6.
Sci Rep ; 12(1): 20233, 2022 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-36418386

RESUMO

The transition from controlled to partial support ventilation is a challenge in acute respiratory distress syndrome (ARDS) patients due to the risks of patient-self-inflicted lung injury. The magnitude of tidal volume (VT) and intrapulmonary dyssynchrony (pendelluft) are suggested mechanisms of lung injury. We conducted a prospective, observational, physiological study in a tertiary academic intensive care unit. ARDS patients transitioning from controlled to partial support ventilation were included. On these, we evaluated the association between changes in inflammatory biomarkers and esophageal pressure swing (ΔPes), transpulmonary driving pressure (ΔPL), VT, and pendelluft. Pendelluft was defined as the percentage of the tidal volume that moves from the non-dependent to the dependent lung region during inspiration, and its frequency at different thresholds (- 15, - 20 and - 25%) was also registered. Blood concentrations of inflammatory biomarkers (IL-6, IL-8, TNF-α, ANGPT2, RAGE, IL-18, Caspase-1) were measured before (T0) and after 4-h (T4) of partial support ventilation. Pendelluft, ΔPes, ΔPL and VT were recorded. Nine out of twenty-four patients (37.5%) showed a pendelluft mean ≥ 10%. The mean values of ΔPes, ΔPL, and VT were - 8.4 [- 6.7; - 10.2] cmH2O, 15.2 [12.3-16.5] cmH2O and 8.1 [7.3-8.9] m/kg PBW, respectively. Significant associations were observed between the frequency of high-magnitude pendelluft and IL-8, IL-18, and Caspase-1 changes (T0/T4 ratio). These results suggest that the frequency of high magnitude pendelluft may be a potential determinant of inflammatory response related to inspiratory efforts in ARDS patients transitioning to partial support ventilation. Future studies are needed to confirm these results.


Assuntos
Lesão Pulmonar , Síndrome do Desconforto Respiratório , Humanos , Interleucina-18 , Estudos Prospectivos , Interleucina-8 , Respiração , Síndrome do Desconforto Respiratório/terapia , Biomarcadores , Caspase 1 , Pulmão
10.
Crit Care Med ; 49(10): e1015-e1024, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-33938714

RESUMO

OBJECTIVES: It is not known how lung injury progression during mechanical ventilation modifies pulmonary responses to prone positioning. We compared the effects of prone positioning on regional lung aeration in late versus early stages of lung injury. DESIGN: Prospective, longitudinal imaging study. SETTING: Research imaging facility at The University of Pennsylvania (Philadelphia, PA) and Medical and Surgical ICUs at Massachusetts General Hospital (Boston, MA). SUBJECTS: Anesthetized swine and patients with acute respiratory distress syndrome (acute respiratory distress syndrome). INTERVENTIONS: Lung injury was induced by bronchial hydrochloric acid (3.5 mL/kg) in 10 ventilated Yorkshire pigs and worsened by supine nonprotective ventilation for 24 hours. Whole-lung CT was performed 2 hours after hydrochloric acid (Day 1) in both prone and supine positions and repeated at 24 hours (Day 2). Prone and supine images were registered (superimposed) in pairs to measure the effects of positioning on the aeration of each tissue unit. Two patients with early acute respiratory distress syndrome were compared with two patients with late acute respiratory distress syndrome, using electrical impedance tomography to measure the effects of body position on regional lung mechanics. MEASUREMENTS AND MAIN RESULTS: Gas exchange and respiratory mechanics worsened over 24 hours, indicating lung injury progression. On Day 1, prone positioning reinflated 18.9% ± 5.2% of lung mass in the posterior lung regions. On Day 2, position-associated dorsal reinflation was reduced to 7.3% ± 1.5% (p < 0.05 vs Day 1). Prone positioning decreased aeration in the anterior lungs on both days. Although prone positioning improved posterior lung compliance in the early acute respiratory distress syndrome patients, it had no effect in late acute respiratory distress syndrome subjects. CONCLUSIONS: The effects of prone positioning on lung aeration may depend on the stage of lung injury and duration of prior ventilation; this may limit the clinical efficacy of this treatment if applied late.


Assuntos
Lesão Pulmonar/complicações , Decúbito Ventral/fisiologia , Adulto , Idoso , Boston , Feminino , Humanos , Estudos Longitudinais , Lesão Pulmonar/diagnóstico por imagem , Lesão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Pennsylvania , Respiração com Pressão Positiva/métodos , Estudos Prospectivos , Resultado do Tratamento
11.
Am J Respir Crit Care Med ; 204(3): 303-311, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33784486

RESUMO

Rationale: Mortality in acute respiratory distress syndrome (ARDS) has decreased after the adoption of lung-protective strategies. Lower Vt, lower driving pressure (ΔP), lower respiratory rates (RR), and higher end-expiratory pressure have all been suggested as key components of lung protection strategies. A unifying theoretical explanation has been proposed that attributes lung injury to the energy transfer rate (mechanical power) from the ventilator to the patient, calculated from a combination of several ventilator variables.Objectives: To assess the impact of mechanical power on mortality in patients with ARDS as compared with that of primary ventilator variables such as the ΔP, Vt, and RR.Methods: We obtained data on ventilatory variables and mechanical power from a pooled database of patients with ARDS who had participated in six randomized clinical trials of protective mechanical ventilation and one large observational cohort of patients with ARDS. The primary outcome was mortality at 28 days or 60 days.Measurements and Main Results: We included 4,549 patients (38% women; mean age, 55 ± 23 yr). The average mechanical power was 0.32 ± 0.14 J · min-1 · kg-1 of predicted body weight, the ΔP was 15.0 ± 5.8 cm H2O, and the RR was 25.7 ± 7.4 breaths/min. The driving pressure, RR, and mechanical power were significant predictors of mortality in adjusted analyses. The impact of the ΔP on mortality was four times as large as that of the RR.Conclusions: Mechanical power was associated with mortality during controlled mechanical ventilation in ARDS, but a simpler model using only the ΔP and RR was equivalent.


Assuntos
Mortalidade , Respiração Artificial/métodos , Síndrome do Desconforto Respiratório/terapia , Adulto , Idoso , Transferência de Energia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pressão , Taxa Respiratória , Lesão Pulmonar Induzida por Ventilação Mecânica
12.
Acta Anaesthesiol Scand ; 65(2): 228-235, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33037607

RESUMO

RATIONALE: Cyclic strain may be a determinant of ventilator-induced lung injury. The standard for strain assessment is the computed tomography (CT), which does not allow continuous monitoring and exposes to radiation. Electrical impedance tomography (EIT) is able to monitor changes in regional lung ventilation. In addition, there is a correlation between mechanical deformation of materials and detectable changes in its electrical impedance, making EIT a potential surrogate for cyclic lung strain measured by CT (StrainCT ). OBJECTIVES: To compare the global StrainCT with the change in electrical impedance (ΔZ). METHODS: Acute respiratory distress syndrome patients under mechanical ventilation (VT 6 mL/kg ideal body weight with positive end-expiratory pressure 5 [PEEP 5] and best PEEP according to EIT) underwent whole-lung CT at end-inspiration and end-expiration. Biomechanical analysis was used to construct 3D maps and determine StrainCT at different levels of PEEP. CT and EIT acquisitions were performed simultaneously. Multilevel analysis was employed to determine the causal association between StrainCT and ΔZ. Linear regression models were used to predict the change in lung StrainCT between different PEEP levels based on the change in ΔZ. MAIN RESULTS: StrainCT was positively and independently associated with ΔZ at global level (P < .01). Furthermore, the change in StrainCT (between PEEP 5 and Best PEEP) was accurately predicted by the change in ΔZ (R2 0.855, P < .001 at global level) with a high agreement between predicted and measured StrainCT . CONCLUSIONS: The change in electrical impedance may provide a noninvasive assessment of global cyclic strain, without radiation at bedside.


Assuntos
Pulmão , Tomografia , Impedância Elétrica , Humanos , Pulmão/diagnóstico por imagem , Respiração com Pressão Positiva , Tomografia Computadorizada por Raios X
13.
Am J Respir Crit Care Med ; 197(10): 1285-1296, 2018 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-29323536

RESUMO

RATIONALE: In acute respiratory distress syndrome (ARDS), atelectatic solid-like lung tissue impairs transmission of negative swings in pleural pressure (Ppl) that result from diaphragmatic contraction. The localization of more negative Ppl proportionally increases dependent lung stretch by drawing gas either from other lung regions (e.g., nondependent lung [pendelluft]) or from the ventilator. Lowering the level of spontaneous effort and/or converting solid-like to fluid-like lung might render spontaneous effort noninjurious. OBJECTIVES: To determine whether spontaneous effort increases dependent lung injury, and whether such injury would be reduced by recruiting atelectatic solid-like lung with positive end-expiratory pressure (PEEP). METHODS: Established models of severe ARDS (rabbit, pig) were used. Regional histology (rabbit), inflammation (positron emission tomography; pig), regional inspiratory Ppl (intrabronchial balloon manometry), and stretch (electrical impedance tomography; pig) were measured. Respiratory drive was evaluated in 11 patients with ARDS. MEASUREMENTS AND MAIN RESULTS: Although injury during muscle paralysis was predominantly in nondependent and middle lung regions at low (vs. high) PEEP, strong inspiratory effort increased injury (indicated by positron emission tomography and histology) in dependent lung. Stronger effort (vs. muscle paralysis) caused local overstretch and greater tidal recruitment in dependent lung, where more negative Ppl was localized and greater stretch was generated. In contrast, high PEEP minimized lung injury by more uniformly distributing negative Ppl, and lowering the magnitude of spontaneous effort (i.e., deflection in esophageal pressure observed in rabbits, pigs, and patients). CONCLUSIONS: Strong effort increased dependent lung injury, where higher local lung stress and stretch was generated; effort-dependent lung injury was minimized by high PEEP in severe ARDS, which may offset need for paralysis.


Assuntos
Pulmão/fisiopatologia , Respiração com Pressão Positiva/métodos , Respiração Artificial/efeitos adversos , Respiração Artificial/métodos , Síndrome do Desconforto Respiratório/complicações , Síndrome do Desconforto Respiratório/terapia , Animais , Modelos Animais de Doenças , Coelhos , Suínos
15.
J Thorac Dis ; 8(9): E982-E986, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27747041

RESUMO

Noninvasive ventilation (NIV) is commonly used to prevent endotracheal intubation in patients with acute respiratory distress syndrome (ARDS). Patients with hypoxemic acute respiratory failure who fail an NIV trial carry a worse prognosis as compared to those who succeed. Additional factors are also knowingly associated with worse outcomes: higher values of ICU severity score, presence of severe sepsis, and lower ratio of arterial oxygen tension to fraction of inspired oxygen. However, it is still unclear whether NIV failure is responsible for the worse prognosis or if it is merely a marker of the underlying disease severity. There is therefore an ongoing debate as to whether and which ARDS patients are good candidates to an NIV trial. In a recent paper published in JAMA, "Effect of Noninvasive Ventilation Delivered by Helmet vs. Face Mask on the Rate of Endotracheal Intubation in Patients with Acute Respiratory Distress Syndrome: A Randomized Clinical Trial", Patel et al. evaluated ARDS patients submitted to NIV and drew attention to the importance of the NIV interface. We discussed their interesting findings focusing also on the ventilator settings and on the current barriers to lung protective ventilation in ARDS patients during NIV.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA