Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Sci Rep ; 12(1): 2658, 2022 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-35173244

RESUMO

Zinc oxide nanoparticles (ZnO NPs) are one of the most widely used nanoparticulate materials due to their antimicrobial properties, but their main mechanism of action (MOA) has not been fully elucidated. This study characterized ZnO NPs by using X-ray diffraction, FT-IR spectroscopy and scanning electron microscopy. Antimicrobial activity of ZnO NPs against the clinically relevant bacteria Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa, and the Gram-positive model Bacillus subtilis was evaluated by performing resazurin microtiter assay (REMA) after exposure to the ZnO NPs at concentrations ranging from 0.2 to 1.4 mM. Sensitivity was observed at 0.6 mM for the Gram-negative and 1.0 mM for the Gram-positive cells. Fluorescence microscopy was used to examine the interference of ZnO NPs on the membrane and the cell division apparatus of B. subtilis (amy::pspac-ftsZ-gfpmut1) expressing FtsZ-GFP. The results showed that ZnO NPs did not interfere with the assembly of the divisional Z-ring. However, 70% of the cells exhibited damage in the cytoplasmic membrane after 15 min of exposure to the ZnO NPs. Electrostatic forces, production of Zn2+ ions and the generation of reactive oxygen species were described as possible pathways of the bactericidal action of ZnO. Therefore, understanding the bactericidal MOA of ZnO NPs can potentially help in the construction of predictive models to fight bacterial resistance.


Assuntos
Bacillus subtilis/efeitos dos fármacos , Escherichia coli/efeitos dos fármacos , Nanopartículas Metálicas , Pseudomonas aeruginosa/efeitos dos fármacos , Staphylococcus aureus/efeitos dos fármacos , Óxido de Zinco/farmacologia , Bacillus subtilis/metabolismo , Relação Dose-Resposta a Droga , Farmacorresistência Bacteriana , Escherichia coli/metabolismo , Testes de Sensibilidade Microbiana/métodos , Pseudomonas aeruginosa/metabolismo , Espécies Reativas de Oxigênio/metabolismo , Staphylococcus aureus/metabolismo , Eletricidade Estática
2.
Braz. arch. biol. technol ; Braz. arch. biol. technol;53(5): 1235-1244, Sept.-Oct. 2010. ilus, tab
Artigo em Inglês | LILACS | ID: lil-564102

RESUMO

The aim of this work was to investigate the disinfectant effect of electrolysis on chlorine-free water, artificially contaminated with Escherichia coli (CCT-1457) and to evaluate the bactericidal activity of electrolysis and kinetic behavior of a single-cell reactor, with a DSA (Dimensionally Stable Anode) electrode to develop a scaled-up system. A high-density E. coli suspension (10(6) CFU mL-1) was electrolyzed in this reactor at 25, 50 and 75 mA cm-2 for up to 60 min, at flow rates of 200 and 500 L h-1. Bacterial survival fell by 98.9 percent without addition of chlorinated compounds and a power consumption rate not more than 5.60 kWh m-3 at flow rate of 200 L h-1 and 75 mA cm-2. The process produced a germicidal effect that reached this inactivation rate within a relatively short contact time. Also, a solution of electrolyzed 0.08 M Na2SO4 added to the inoculum showed residual bactericidal effect. The efficiency of disinfection was regulated by both the contact time and current density applied, and a kinetic function for the survival rate was developed for the purpose of scaling up.


Água contaminada é uma das maiores origens de doenças em seres humanos. Em todo o mundo, a cloração é o método mais utilizado para promover desinfecção em águas de abastecimento devido ao seu efeito residual, quando adequadamente calculado. Contudo, se a água apresentar matéria orgânica, pode haver a geração de organoclorados, os quais são genotóxicos e carcinogênicos. Sob esta óptica, investigamos o efeito bactericida da aplicação da eletrólise em água sem cloro contaminada com Escherichia coli (CCT-1457). O objetivo deste estudo foi avaliar o poder de desinfecção e o comportamento cinético da eletrólise realizada em reator de compartimento único e usando eletrodos ADE (Anodo Dimensionalmente Estável), visando ampliação de escala. Uma suspensão contendo elevada concentração de E. coli (10(6) UFC mL-1) foi submetida ao tratamento no reator em 25, 50 e 75 mA cm-2 durante 60 min, em vazões de 200 e 50 Lh-1. A taxa de inativação foi aproximadamente 99 por cento para a solução isenta de compostos clorados, com consumo de energia elétrica menor que 5,60 kWh m-3 em 200 L h-1 e 75 mA cm-2. Uma solução de Na2SO4 0,08M eletrolisada e adicionada posteriormente ao inoculo apresentou efeito residual bactericida. A eficiência da desinfecção foi regida pelo tempo de contato e pela densidade de corrente aplicada, e foi realizado um estudo cinético que permite a ampliação de escala.

3.
Chemosphere ; 58(1): 41-6, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15522331

RESUMO

Sanitary landfills are the major method used today for the disposal and management of municipal solid waste. Decomposition of waste and rainfall generate leachate at the bottom of landfills, causing groundwater contamination. In this study, leachate from a municipal landfill site was treated by electrochemical oxidation in a pilot scale flow reactor, using oxide-coated titanium anode. The experiments were conducted under a constant flow rate of 2000 lh(-1) and the effect of current density on chemical oxygen demand, total organic carbon, color and ammonium removal was investigated. At a current density of 116.0 mA cm(-2) and 180 min of processing, the removal rates achieved were 73% for COD, 57% for TOC, 86% for color and 49% for ammonium. The process proved effective in degrading leachate, despite this effluent's usual refractoriness to treatment.


Assuntos
Eletroquímica , Eliminação de Resíduos , Poluição Química da Água/prevenção & controle , Carbono/química , Oxirredução , Oxigênio/química , Compostos de Amônio Quaternário/química , Espectrofotometria Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA