1.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;37(3): 409-411, May-June 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1376535

RESUMO

ABSTRACT Accidental detachment of mechanical valve leaflet during implantation is a rare and potentially serious complication. When the lost leaflet cannot be found by direct visualisation, additional diagnostic procedures are necessary to detect it. Computer tomography is the best detection method, but the patient needs reoperation. We presented a patient in whom the detached leaflet migrated and became trapped into the left inferior pulmonary vein. The computed tomography (CT) scan was used to reveal leaflets, and successful extirpation was performed in the second operation.

2.
Braz J Cardiovasc Surg ; 37(3): 409-411, 2022 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-35436079

RESUMO

Accidental detachment of mechanical valve leaflet during implantation is a rare and potentially serious complication. When the lost leaflet cannot be found by direct visualisation, additional diagnostic procedures are necessary to detect it. Computer tomography is the best detection method, but the patient needs reoperation. We presented a patient in whom the detached leaflet migrated and became trapped into the left inferior pulmonary vein. The computed tomography (CT) scan was used to reveal leaflets, and successful extirpation was performed in the second operation.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Veias Pulmonares , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/cirurgia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Reoperação
3.
Braz J Cardiovasc Surg ; 35(6): 35-6, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33306329

RESUMO

We presented a case of a 56-year-old man with giant pulmonary artery aneurysm caused by a misdiagnosed patent ductus arteriosus, severe multivalvular disease and active aortic valve endocarditis successfully treated by surgery. The correct diagnosis was missed despite preoperative diagnostics because the small patent ductus arteriosus was located at the distal part of common pulmonary trunk and a huge regurgitant signal overlapped its Doppler signal. Thorough evaluation of every patient, regardless of age, is necessary to recognize and treat this congenital anomaly.


Assuntos
Permeabilidade do Canal Arterial/diagnóstico , Idoso , Canal Arterial , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/cirurgia , Ecocardiografia , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar
4.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;35(6): 1013-1016, Nov.-Dec. 2020. tab, graf
Artigo em Inglês | LILACS, Sec. Est. Saúde SP | ID: biblio-1143994

RESUMO

Abstract We presented a case of a 56-year-old man with giant pulmonary artery aneurysm caused by a misdiagnosed patent ductus arteriosus, severe multivalvular disease and active aortic valve endocarditis successfully treated by surgery. The correct diagnosis was missed despite preoperative diagnostics because the small patent ductus arteriosus was located at the distal part of common pulmonary trunk and a huge regurgitant signal overlapped its Doppler signal. Thorough evaluation of every patient, regardless of age, is necessary to recognize and treat this congenital anomaly.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Permeabilidade do Canal Arterial/diagnóstico , Artéria Pulmonar , Ecocardiografia , Canal Arterial , Permeabilidade do Canal Arterial/cirurgia , Permeabilidade do Canal Arterial/diagnóstico por imagem