Circ., cariovasc. interv. (Print) ; 14(6): 010440, June. 2021. graf, ilus, tab
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1352656

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has determined a paradigm shift in the treatment of patients with severe aortic stenosis. However, the durability of bio prostheses is still a matter of concern, and little is known about the management of degenerated TAV. We sought to evaluate the outcomes of patients with a degenerated TAV treated by means of a second TAVR. METHODS: The TRANSIT is an international registry that included cases of degenerated TAVR from 28 centers. Among around 40 000 patients treated with TAVR in the participating centers, 172 underwent a second TAVR: 57 (33%) for a mainly stenotic degenerated TAV, 97 (56%) for a mainly regurgitant TAV, and 18 (11%) for a combined degeneration. Overall, the rate of New York Heart Association class III/IV at presentation was 73.5%. RESULTS: Valve Academic Research Consortium 2 device success rate was 79%, as a consequence of residual gradient (14%) or regurgitation (7%). At 1 month, the overall mortality rate was 2.9%, while rates of new hospitalization and New York Heart Association class III/IV were 3.6% and 7%, respectively, without significant difference across the groups. At 1 year, the overall mortality rate was 10%, while rates of new hospitalization and New York Heart Association class III/IV were 7.6% and 5.8%, respectively, without significant difference across the groups. No cases of valve thrombosis were recorded. CONCLUSIONS: Selected patients with a degenerated TAV may be safely and successfully treated by means of a second TAVR. This finding is of crucial importance for the adoption of the TAVR technology in a lower risk and younger population.


Assuntos
Estenose da Valva Aórtica , Próteses e Implantes , Substituição da Valva Aórtica Transcateter
2.
Int. j. cardiol ; Int. j. cardiol;300(1): 60-65, Jul, 2019. tabela, gráfico
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1103433

RESUMO

Background The aim of this study was to compare the 12-month clinical outcomes of patients treated with Magmaris or Orsiro. Second generation drug-eluting absorbable metal scaffold Magmaris (Dreams 2G) has proved to be safe and effective in the BIOSOLVE-II study. Similarly, biodegradable polymer sirolimus-eluting stent, Orsiro has shown notable clinical results even in all-comer populations. Methods Magmaris group patients were taken from the BIOSOLVE-II and BIOSOLVE-III trials, while the patients from Orsiro group were enrolled in BIOFLOW-II trial. The primary outcome was explored using a time-to-event assessment of the unadjusted clinical outcomes for target lesion failure (TLF) at 12 months, followed by a multivariate analysis adjusting for all the significantly different covariates between the groups. Results The study population consisted of 482 patients (521 lesions), 184 patients (189 lesions) in Magmaris group and 298 patients (332 lesions) in Orsiro group. The mean age was 65.5 ±â€¯10.8 and 62.7 ±â€¯10.4 years in Magmaris and Orsiro groups, respectively ( p = 0.005). Magmaris and Orsiro unadjusted TLF rates were 6.0 and 6.4% with no significant difference between the groups ( p = 0.869). In the multivariate analysis, there were no meaningful differences between Magmaris and Orsiro groups. Finally, none of the groups presented device thrombosis cases at 12 months. Conclusion At 12 months there were no significant differences between Magmaris and Orsiro groups neither in the unadjusted assessment nor in the multivariate analysis for target lesion failure. These results should be taken as hypothesis generating and may warrant a head to head comparison on a randomized fashion.


Assuntos
Análise Multivariada , Stents Farmacológicos , Sirolimo
3.
Catheter. cardiovasc. interv ; 92(7): 502, : 511, Dec. 2018. graf, tab, ilus
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1247595

RESUMO

OBJECTIVES: Based on outcomes of the BIOSOLVE-II study, a novel second generation drug eluting absorbable metal scaffold gained CE-mark in 2016. The BIOSOLVE-III study aimed to confirm these outcomes and to obtain additional 12-month angiographic data. BACKGROUND: Bioresorbable scaffolds are intended to overcome possible long-term effects of permanent stents such as chronic vessel wall inflammation, stent crushing, and fractures. METHODS: The prospective, multicenter BIOSOLVE-II and BIOSOLVE-III studies enrolled 184 patients with 189 lesions (123 patients in BIOSOLVE-II and 61 patients in BIOSOLVE-III). Primary endpoints were in-segment late lumen loss at 6 months (BIOSOLVE-II) and procedural success (BIOSOLVE-III). RESULTS: Mean patient age was 65.5 6 10.8 years and mean lesion reference diameter was 2.70 6 0.43 mm. In BIOSOLVE-III, there were significantly more type B2/C lesions than in BIOSOLVE-II (80.3% versus 43.4%, P < 0.0001) and significantly more moderate-to-severe calcifications (24.2% versus 10.7%, P 5 0.014). At 12 months, there was no difference in late lumen loss between the two studies; in the overall population, it was 0.25 6 0.31 mm in-segment and 0.396 0.34 mm in scaffold. Target lesion failure occurred in six patients (3.3%) and included two cardiac deaths, one target-vessel myocardial infarction, and three clinically driven target lesion revascularizations. No definite or probable scaffold thrombosis was observed. CONCLUSION: The pooled outcomes of BIOSOLVE-II and BIOSOLVE-III provide further evidence on the safety and performance of a novel drug-eluting absorbable metal scaffold with constant clinical and angiographic performance parameters at 12 months and no definite or probable scaffold thrombosis.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Doença da Artéria Coronariana/diagnóstico por imagem , Intervenção Coronária Percutânea , Implantes Absorvíveis , Stents Farmacológicos