RESUMO
Evaluation of the influence of laser application on osseointegration around implants with different surface characteristics is limited. This study aims to evaluate the influence of low-level lasers on the early stages of osseointegration. Ninety-six external hex implants (3.75 mm × 5.0 mm) were placed in 24 rabbits-one machined and one sandblasted acid-etched per tibia. The rabbits were later divided into the laser group, which received a total dose of 24 J/cm(2) of gallium-aluminum-arsenide laser over 15 days, and a control group. At 16 and 30 days after surgery, removal torque and histomorphometric analyses were performed. No statistical differences in removal torque or histomorphometric analyses were verified between laser and control groups regardless of implant surface (P > .05). Time was the only variable presenting significant differences between measurements (P < .05). Low-level laser had no significant short-term effect on bone-to-implant contact and removal torque values regardless of implant surface characteristics.
Assuntos
Implantes Dentários , Osseointegração , Animais , Planejamento de Prótese Dentária , Coelhos , Propriedades de Superfície , Tíbia , Titânio , TorqueRESUMO
PURPOSE: To assess osseointegration by measuring the removal torque of smooth cylindrical implants placed in rabbit tibiae, having been subjected, or not, to low-intensity laser irradiation (GaAlAs). METHODS: Two implants were inserted into one tibiae of 16 male New Zealand rabbits weighing 3.5-4.0 kg; the animals were divided into four groups (control and laser at 16 and 30 days of wound healing). In the irradiated groups, laser was applied at a 830-nm wavelength, in continuous mode and with 100 mW of potency, and the applications were punctual, with 1 J/cm³ on three points, and were repeated eight times at 48-hour intervals starting immediately after implantation surgery, thus totaling 24 J/cm². After the wounds healed, the animals were sacrificed, the tibiae were removed, implant removal torques were measured by means of a handheld digital torque-meter, and a factorial variance analysis statistical test was applied. RESULTS: There was significant intergroup difference regarding time as a single factor. The removal torque observed in the control groups was, for smooth implants, 20.42±3.06 N/cm at 16 days and 27.42±19.65 N/cm at 30 days; in the irradiated groups, the removal torque for smooth implants was 19.15±4.65 N/cm at 16 days and 30.08±4.14 N/cm at 30 days. CONCLUSION: Removal torque values were higher at 30 days than at 16 days, independent of laser application.
OBJETIVO: Avaliar a osseointegração através do torque de remoção de implantes cilíndricos lisos, colocados em tíbias de coelhos, submetidos ou não à irradiação com laser de baixa intensidade (AsGaAl). METODOLOGIA: Foram utilizados 16 coelhos machos da raça Nova Zelândia, pesando entre 3,5 a 4,0 quilos, sendo inseridos dois implantes em uma tíbia, dividida em quatro grupos (controle e laser para 16 e 30 dias de cicatrização). No grupo irradiado foi aplicado laser com comprimento de onda de 830 nm, modo contínuo e potência de 100 mW, sendo a aplicação pontual de 1 J/cm² em três pontos e oito aplicações, com intervalo de 48 horas, iniciada imediatamente após a cirurgia de colocação dos implantes, perfazendo um total de 24 J/cm². Após o período de cicatrização, os animais foram sacrificados, e então, realizada a remoção das tíbias e, em seguida, a medição dos torques para remoção dos implantes com torquímetro digital manual, aplicando-se o teste estatístico de Análise de Variância Fatorial. RESULTADOS: Foi verificado que existe diferença significativa intra-grupos em relação ao fator isolado tempo. O torque de remoção obtido para o grupo controle: Implantes lisos com 16 dias (20,42±3,06 N/cm) e 30 dias (27,42±19,65 N/cm); e para o grupo irradiado: Implantes lisos com 16 dias (19,15±4,65 N/cm) e 30 dias (30,08±4,14 N/cm). CONCLUSÃO: Os valores do torque de remoção no período de 30 dias são superiores ao período de 16 dias, independentemente da aplicação de laser.
Assuntos
Animais , Coelhos , Lasers , Osseointegração , Estudos de Casos e ControlesRESUMO
This study evaluated the fit between implants and premachined and castable UCLA abutments. All plastic specimens were cast using the conventional technique in accordance with the manufacturer's instructions. Five specimens of each experimental group were measured for vertical and horizontal gaps by scanning electronic microscopy (Phillips XL 30 model, Holland). Gold UCLA (vertical gap: 2.15 microm, horizontal gap: 11.30 microm) and castable rotational UCLA (vertical gap: 14.91 microm, horizontal gap: 59.41 microm) groups showed the lowest and highest mean values, respectively (Neodent, Curitiba, Parana, Brazil). In general, the castable UCLA abutments showed poorer marginal fit than the premachined abutments.
Assuntos
Dente Suporte , Implantes DentáriosRESUMO
This study evaluated the fit between implants and premachined and castable UCLA abutments. All plastic specimens were cast using the conventional technique in accordance with the manufacturer's instructions. Five specimens of each experimental group were measured for vertical and horizontal gaps by scanning electronic microscopy (Phillips XL 30 model, Holland). Gold UCLA (vertical gap: 2.15 μm, horizontal gap: 11.30 μm) and castable rotational UCLA (vertical gap: 14.91 μm, horizontal gap: 59.41 μm) groups showed the lowest and highest mean values, respectively (Neodent, Curitiba, Parana, Brazil). In general, the castable UCLA abutments showed poorer marginal fit than the premachined abutments.
Esse estudo avaliou a adaptacao entre implantes pilares UCLA usinados e fundidos. Todos os corpos de prova de plastico foram fundidos usando tecnica de fundicao convencional de acordo com o fabricante. Cinco corpos de prova foram avaliados em relacao a desadaptacao vertical e horizontal utilizando um Microscopio Eletronico de Varredura. Os grupos UCLA Ouro (desadaptacao vertical: 2.15 μm, horizontal : 11.30 μm) e UCLA rotacional fundido (desadaptacao vertical: 14.91 μm, horizontal: 59.41 μm) mostraram as medias mais baixas e mais altas, respectivamente. De uma maneira geral, os pilares UCLA fundidos mostraram adaptacao menor do que os pilares UCLA usinados.
RESUMO
O objetivo deste estudo foi avaliar a precisão de adaptação e a compatibilidade entre os componentes intermediários e implantes ad modum Branemark em dois sistemas nacionais (Conexão e Neodent) em dois estrangeiros (Branemark e 31 Impant Innovatins) e no intercâmbio de componentes entre esses sistemas. A interface implante/intermediário (fenda vertical e discrepância horizontal) foi avaliada por microscopia eletrônica de varredura para cada um dos quatro sistemas de implantes, assim como no intercâmbio entre esses sistemas. Para a comparação dos resultados, foram utilizados o procedimento de análise de variância (Anova-Oneway) e o procedimento posterior de Tukey, ao nível de significância de 5 por cento. Os resultados mostraram diferenças significantes entre sistemas. As menores medidas da fenda vertical foram encontradas nas combinações utilizando intermediários da marca Conexão e 31. As maiores fendas verticais foram encontradas nas combinações com intermediários do sistema Branemark. As menores medidas da discrepância horizontal foram encontradas nas combinações utilizando os intermediários da marca 31, seguidos das combinações utilizando os intermediários da marca Conexão. Os maiores valores para discrepância horizontal foram encontrados sempre com intermediários do sistema Branemark, as quais apresentam menor diâmetro de intermediário na porção voltada ao implante. Os sistemas de implantes analisados são compatíveis, sendo possível o encaixe de todos os intermediários sobre todos os implantes, com diferença nos resultados dos sistemas originais para os do intercâmbio entre componentes
Assuntos
Implantes DentáriosRESUMO
Objetivo: Avaliar a liberdade rotacional e a compatibilidade entre o componente intermediário e o implante "ad modum" Branemark em dois sistemas brasileiros (Conexão e Neodent) e em dois sistemas estrangeiros (Branemark e 3I Implant Innovations), bem como o intercâmbio de componentes. Material e Métodos: A liberdade rotacional entre os sextavados dos dois componentes foi mensurada com um relógio comparador adaptado. Os dados foram analisados por ANOVA de fator único e teste de Tukey, ao nível de significância de 5 por cento. Resultados: Os menores valores de liberdade rotacional foram encontrados nas combinações utilizando os intermediários do sistema Conexão; maior liberdade rotacional foi verificada nas combinações com intermediários do sistema Branemark. Conclusão: Os sistemas de implante analisados são compatíveis, sendo possível o encaixe de todos os intermediários sobre todos os implantes, com diferenças nos resultados dos sistemas originais para os do intercâmbio entre componentes
Assuntos
Humanos , Masculino , Feminino , Fenômenos Biomecânicos , Implantes Dentários/instrumentação , Implantes Dentários/métodosRESUMO
Ao fazer uma exodontia, o cirurgiäo-dentista pode deparar-se com algumas complicaçöes, dentre elas a hemorragia e a alveolite. Pacientes que apresentam disúrbios hemorrágicos podem ser portadores de deficiências dos fatores de coagulaçäo e/ou plaquetários, podendo ter, também, como causa, corpos estranhos no interior do alvéolo. A freqüência relatada da ocorrência de alveolite está entre 1 e 3,2 por cento de todas as exodontias. Na maioria das vezes, ocorre em extraçöes traumáticas. A alveolite é extremamente dolorosa e geralmente é tratada pela inserçäo de um curativo contendo um obtundente no interior do alvéolo