1.
Int J Retina Vitreous ; 8(1): 32, 2022 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-35655248

RESUMO

BACKGROUND: Diabetic macular edema (DME) is the main cause of visual loss in diabetic patients. Despite the use of anti-VEGF therapy as first-line treatment, there are many patients whose response to treatment is poor or transient at best. Sophisticated laser techniques have emerged aiming at low-intensity retinal damage, avoiding excessive heat that causes tissue necrosis and related collateral effects. OBJECTIVE: To evaluate the effect of combined sublethal laser modalities from short-pulse duration (SPD) with endpoint management (EpM) subthreshold laser [named the "sandwich technique" (SWiT)] on central subfield thickness (CST) and best-corrected visual acuity (BCVA) in patients with DME. MATERIAL AND METHODS: In this consecutive retrospective study, 37 patients (37 eyes) with center-involved (CI) DME were treated with SWiT laser therapy from April 2017 to June 2021. The technique consisted of a mean number of 200 (range number 50-400) SPD laser burns OCT-guided thickened area performed on the juxta- and perifoveal area 500 µm away from the foveal center, overlapping with a mean number of 1000 (range number 800-1200) EpM laser burns focused on 6 mm macular diameter area but saving 300 µm toward the foveal center. All patients underwent ophthalmological evaluations, including BCVA and CST measurement by spectral-domain optical coherence tomography (SD-OCT), before and after SWiT laser therapy. The mean follow-up time was 19.2 months (range 2-60 months). RESULTS: Thirty-five out of 37 cases showed an improvement in CST and BCVA following treatment. At baseline, mean CST (µm) ± standard error (SE) and mean BCVA (logMAR) ± SE was 456.95 ± 37.00 and 0.71 ± 0.29, respectively. After a mean follow-up of 19.2 months, mean CST (µm) ± SE and BCVA (logMAR) ± SE were 272.09 ± 9.10 (p < 0.0001) and 0.54 ± 0.26 (p = 0.003), respectively. A statistically significant reduction in CST and improvement in BCVA was noted after laser therapy application. The anti-VEGF injection frequency was reduced during the mean 19.2 months of the study period. CONCLUSIONS: The novel "sandwich" laser therapy aid reduced CST and improved BCVA in this retrospective case series. Further prospective studies are warranted.

2.
Physiol Meas ; 21(1): 197-207, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10720015

RESUMO

We have developed a spectroscopy system dedicated to eye banks in order to standardize the evaluation of the donated corneas, with respect to their transparency. The system for measuring the corneal transmission spectrum basically consists of a conventional spectroscopy single beam optical apparatus, with particularities in order to attend to the needs of the eye banks, having a linear CCD (2048 sensors) as a detector. The range of evaluation of the system is from 400 to 700 nm, which is the range of interest for these kinds of sample (corneas). Dedicated software has been developed in order to acquire the data from the system and to provide the graphical interface for the user. The software is quite easy to manipulate and provides the diagnostic with respect to the transparency of the cornea, which is based on research done in association with the clinicians of the Eye Bank of Hospital das Clínicas de Ribeirão Preto (Brazil). The system presents a resolution of 9 nm (which is good enough for this kind of measurement, that presents large bandwidths) and it is in agreement with the spectra obtained from commercial spectrophotometers (the correlation factor between our system and a Beckman DU-70 is 0.995 43 for samples of well defined bandwidths, and 0.989 73 for corneas--large bandwidth).


Assuntos
Córnea/fisiologia , Espectrofotometria/instrumentação , Opacidade da Córnea/diagnóstico , Opacidade da Córnea/fisiopatologia , Desenho de Equipamento , Estudos de Avaliação como Assunto , Bancos de Olhos , Humanos , Técnicas In Vitro , Luz , Espalhamento de Radiação , Software , Espectrofotometria/estatística & dados numéricos , Doadores de Tecidos , Obtenção de Tecidos e Órgãos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA