Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Odovtos (En línea) ; 23(2)ago. 2021.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1386530

RESUMO

ABSTRACT: The clinical management of the epulis involves the elimination of causal factors, excision of fibrous tissue excess accompanied by an appropriate prosthetic rehabilitation. The confection of interim prosthesis or the rectification of old prosthesis for the setting up of a tissue conditioner if necessary, to improve the healing and prevent the decrease of the vestibule depth after the surgical exeresis. Throughout this paper, we are going to present a new technique for the correction of old prostheses poorly adapted for the management of a case of the epulis fissuratum.


RESUMEN: El manejo clínico de un épulis comprende la eliminación de los agentes causales y la eliminación del tejido fibroso, acompañado de una adecuada rehabilitación protésica. Es necesaria la confección de una prótesis provisional o la rectificación de la prótesis vieja, para la colocación del acondicionador de tejidos si fuera necesario para mejorar el sanado y prevenir la disminución de la profundidad del vestíbulo después de la exéresis quirúrgica. En este artículo, presentaremos una nueva técnica para la corrección de la prótesis desajustada en el manejo de un caso de épulis fisurado.


Assuntos
Humanos , Prótese Dentária/instrumentação , Doenças da Gengiva/terapia
2.
Braz. dent. sci ; 24(2): 1-10, 2021. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1178333

RESUMO

Objective: The aim of this experimental study was to assess the effect of khat extract with different concentrations on the corrosion resistance of cobalt-chromium (Co-Cr) dental alloys used for removable denture. Material and Methods:The corrosion resistance of three Co-Cr alloys (Neobond II®, Kera 501® and PD Casta H®) was evaluated in artificial saliva in presence of three different concentrations of khat extracts. Fusayama-Meyer artificial saliva was used as a reference solution. The corrosion properties of the alloys were analyzed using potentiodynamic polarization, electrochemical impedance spectroscopy and surface analysis. The data was presented in means, standard deviations, and related figures. Comparison between the different concentrations was done using 1-way ANOVA test. The surface analysis was performed using scanning electron microscopy (SEM). Results: the results showed that the corrosion resistance of the three alloys tested (Neobond II®, Kera 501® and PD Casta H®) decreased in artificial saliva containing khat extract compared with that of the reference solution. Additionally, the corrosion resistance of the three Co-Cr dental alloys decreased by increasing the concentration of khat extract. Furthermore, the results indicate that Neobond II® alloy showed the least corrosion resistance compared with that of Kera 501® and PD Casta H® alloys. Conclusion: Khat extract with different concentrations had negative impact on the corrosion resistance of Cr-Co alloys. More in-vivo studies are highly recommended to confirm the results of the present study (AU)


Objetivo: O objetivo deste estudo experimental foi avaliar o efeito do extrato de khat em diferentes concentrações na resistência à corrosão de ligas dentárias de cobalto-cromo (Co-Cr) utilizadas em próteses removíveis. Material e Métodos:A resistência à corrosão de três ligas de Co-Cr (Neobond II®, Kera 501® e PD Casta H®) foi avaliada em saliva artificial na presença de três concentrações diferentes de extratos khat. A saliva artificial de Fusayama-Meyer foi usada como solução de referência. As propriedades de corrosão das ligas foram analisadas usando polarização potenciodinâmica, espectroscopia de impedância eletroquímica e análise de superfície. Os dados foram apresentados em médias, desvios-padrão e figuras relacionadas. A comparação entre as diferentes concentrações foi feita usando o teste One-way ANOVA. A análise de superfície foi realizada em microscopia eletrônica de varredura (MEV). Resultados: os resultados mostraram que a resistência à corrosão das três ligas testadas (Neobond II®, Kera 501® e PD Casta H®) diminuiu na saliva artificial contendo extrato khat em comparação com a solução de referência. Além disso, a resistência à corrosão das três ligas dentais Co-Cr diminuiu com o aumento da concentração de extrato de khat. Além disso, os resultados indicam que a liga Neobond II® apresentou a menor resistência à corrosão em comparação com as ligas Kera 501® e PD Casta H®. Conclusão: O extrato de Khat com diferentes concentrações teve impacto negativo na resistência à corrosão de ligas de Cr-Co. Mais estudos in vivo são altamente recomendados para confirmar os resultados do presente estudo. (AU)


Assuntos
Catha , Ligas Dentárias , Corrosão Dentária , Prótese Parcial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA