Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Perfusion ; 37(7): 684-691, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-34080462

RESUMO

OBJECTIVE: The aim of this study was to evaluate outcome measures between our standard multidose cardioplegia protocol and a del Nido cardioplegia protocol in congenital heart surgery patients. METHODS: Retrospective single-center study including 250 consecutive patients that received del Nido cardioplegia (DN group) with a mandatory reperfusion period of 30% of cross clamp time and 250 patients that received a modified St. Thomas' solution (ST group). Groups were matched by age, weight, gender, and Risk Adjustment for Congenital Heart Surgery (RACHS-1) scores. Preoperative hematocrit and oxygen saturation were also recorded. Outcomes analyzed were the vasoactive inotropic score (VIS), lactate, ventilation time, ventricular dysfunction with low cardiac output syndrome (LCOS), intensive care unit (ICU) length of stay (LOS), hospital LOS, bypass and aortic cross-clamp times, and in-hospital mortality. RESULTS: Both groups were comparable demographically. Statistically significant differences (p ⩽ 0.05) were noted for cardiac dysfunction with LCOS, hematocrit at end of surgery (p = 0.0038), VIS on ICU admission and at end of surgery (p = 0.0111), and ICU LOS (p = 0.00118) with patients in the DN group having more desirable values for those parameters. Other outcome measures did not reach statistical significance. CONCLUSION: In our congenital cardiac surgery population, del Nido cardioplegia strategy was associated with less ventricular dysfunction with LCOS, a lower VIS and decreased ICU LOS compared with patients that received our standard myocardial protection using a modified St. Thomas' solution. Despite the limitation of this study, including its retrospective nature and cohort size, these data supported our transition to incorporate del Nido cardioplegia solution with a mandatory reperfusion period as the preferred myocardial protection method in our program.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas , Disfunção Ventricular , Brasil , Baixo Débito Cardíaco , Soluções Cardioplégicas/uso terapêutico , Criança , Eletrólitos , Parada Cardíaca Induzida/métodos , Cardiopatias Congênitas/cirurgia , Humanos , Lactatos , Lidocaína , Sulfato de Magnésio , Manitol , Cloreto de Potássio , Estudos Retrospectivos , Bicarbonato de Sódio , Soluções , Disfunção Ventricular/tratamento farmacológico
2.
Braz J Cardiovasc Surg ; 33(3): 224-232, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30043914

RESUMO

OBJECTIVE: Hemodilution is a concern in cardiopulmonary bypass (CPB). Using a smaller dual tubing rather than a single larger inner diameter (ID) tubing in the venous limb to decrease prime volume has been a standard practice. The purpose of this study is to evaluate these tubing options. METHODS: Four different CPB circuits primed with blood (hematocrit 30%) were investigated. Two setups were used with two circuits for each one. In Setup I, a neonatal oxygenator was connected to dual 3/16" ID venous limbs (Circuit A) or to a single 1/4" ID venous limb (Circuit B); and in Setup II, a pediatric oxygenator was connected to dual 1/4" ID venous limbs (Circuit C) or a single 3/8" ID venous limb (Circuit D). Trials were conducted at arterial flow rates of 500 ml/min up to 1500 ml/min (Setup I) and up to 3000 ml/min (Setup II), at 36°C and 28°C. RESULTS: Circuit B exhibited a higher venous flow rate than Circuit A, and Circuit D exhibited a higher venous flow rate than Circuit C, at both temperatures. Flow resistance was significantly higher in Circuits A and C than in Circuits B (P<0.001) and D (P<0.001), respectively. CONCLUSION: A single 1/4" venous limb is better than dual 3/16" venous limbs at all flow rates, up to 1500 ml/min. Moreover, a single 3/8" venous limb is better than dual 1/4" venous limbs, up to 3000 ml/min. Our findings strongly suggest a revision of perfusion practice to include single venous limb circuits for CPB.


Assuntos
Cânula/normas , Ponte Cardiopulmonar/instrumentação , Oxigenadores/normas , Velocidade do Fluxo Sanguíneo/fisiologia , Ponte Cardiopulmonar/métodos , Desenho de Equipamento , Segurança de Equipamentos , Hemodiluição , Humanos , Modelos Cardiovasculares , Pediatria/instrumentação , Padrões de Referência , Reprodutibilidade dos Testes , Temperatura , Fatores de Tempo , Pressão Venosa/fisiologia
3.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;33(3): 224-232, May-June 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-958406

RESUMO

Abstract Objective: Hemodilution is a concern in cardiopulmonary bypass (CPB). Using a smaller dual tubing rather than a single larger inner diameter (ID) tubing in the venous limb to decrease prime volume has been a standard practice. The purpose of this study is to evaluate these tubing options. Methods: Four different CPB circuits primed with blood (hematocrit 30%) were investigated. Two setups were used with two circuits for each one. In Setup I, a neonatal oxygenator was connected to dual 3/16" ID venous limbs (Circuit A) or to a single 1/4" ID venous limb (Circuit B); and in Setup II, a pediatric oxygenator was connected to dual 1/4" ID venous limbs (Circuit C) or a single 3/8" ID venous limb (Circuit D). Trials were conducted at arterial flow rates of 500 ml/min up to 1500 ml/min (Setup I) and up to 3000 ml/min (Setup II), at 36°C and 28°C. Results: Circuit B exhibited a higher venous flow rate than Circuit A, and Circuit D exhibited a higher venous flow rate than Circuit C, at both temperatures. Flow resistance was significantly higher in Circuits A and C than in Circuits B (P<0.001) and D (P<0.001), respectively. Conclusion: A single 1/4" venous limb is better than dual 3/16" venous limbs at all flow rates, up to 1500 ml/min. Moreover, a single 3/8" venous limb is better than dual 1/4" venous limbs, up to 3000 ml/min. Our findings strongly suggest a revision of perfusion practice to include single venous limb circuits for CPB.


Assuntos
Humanos , Oxigenadores/normas , Ponte Cardiopulmonar/instrumentação , Cânula/normas , Pediatria/instrumentação , Padrões de Referência , Temperatura , Fatores de Tempo , Pressão Venosa/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Ponte Cardiopulmonar/métodos , Reprodutibilidade dos Testes , Desenho de Equipamento , Segurança de Equipamentos , Hemodiluição , Modelos Cardiovasculares
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA