Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Am J Vet Res ; 71(9): 1019-26, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20807140

RESUMO

OBJECTIVE: To compare analgesic effects of tramadol, codeine, and ketoprofen administered alone and in combination and their effects on concentrations of blood glucose, serum cortisol, and serum interleukin (IL)-6 in dogs undergoing maxillectomy or mandibulectomy. ANIMALS: 42 dogs with oral neoplasms. PROCEDURES: 30 minutes before the end of surgery, dogs received SC injections of tramadol (2 mg/kg), codeine (2 mg/kg), ketoprofen (2 mg/kg), tramadol+ketoprofen, or codeine+ketoprofen (at the aforementioned dosages). Physiologic variables, analgesia, and sedation were measured before (baseline) and 1, 2, 3, 4, 5, and 24 hours after surgery. Blood glucose, serum cortisol, and serum IL-6 concentrations were measured 1, 3, 5, and 24 hours after administration of analgesics. RESULTS: All treatments provided adequate postoperative analgesia. Significant increases in mean+/-SD blood glucose concentrations were detected in dogs receiving tramadol (96+/-14 mg/dL), codeine (120+/-66 mg/dL and 96+/-21 mg/dL), ketoprofen (105+/-22 mg/dL), and codeine+ketoprofen (104+/-16 mg/dL) at 5, 1 and 3, 5, and 3 hours after analgesic administration, respectively, compared with preoperative (baseline) values. There were no significant changes in physiologic variables, serum IL-6 concentrations, or serum cortisol concentrations. Dogs administered codeine+ketoprofen had light but significant sedation at 4, 5, and 24 hours. CONCLUSIONS AND CLINICAL RELEVANCE: Opioids alone or in combination with an NSAID promoted analgesia without adverse effects during the 24-hour postoperative period in dogs undergoing maxillectomy or mandibulectomy for removal of oral neoplasms.


Assuntos
Analgésicos Opioides/uso terapêutico , Glicemia/metabolismo , Codeína/uso terapêutico , Doenças do Cão/cirurgia , Hidrocortisona/sangue , Cetoprofeno/uso terapêutico , Mandíbula/cirurgia , Neoplasias Mandibulares/veterinária , Maxila/cirurgia , Neoplasias Maxilares/veterinária , Dor Pós-Operatória/veterinária , Tramadol/uso terapêutico , Animais , Glicemia/efeitos dos fármacos , Doenças do Cão/tratamento farmacológico , Cães , Quimioterapia Combinada , Feminino , Masculino , Doenças Mandibulares/cirurgia , Doenças Mandibulares/veterinária , Neoplasias Mandibulares/cirurgia , Doenças Maxilares/cirurgia , Doenças Maxilares/veterinária , Neoplasias Maxilares/cirurgia , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/prevenção & controle
2.
Pesqui. vet. bras ; 30(9): 763-769, 2010. ilus, graf, tab
Artigo em Português | VETINDEX | ID: vti-14551

RESUMO

Eletrorretinograma (ERG) é o meio diagnóstico objetivo e não-invasivo para avaliar a função retiniana e detectar precocemente, em várias espécies, lesões nas suas camadas mais externas. As indicações mais comuns para ERG em cães são: avaliação pré-cirúrgica de pacientes com catarata, caracterização de distúrbios que causam cegueira, além de servir como importante modelo para o estudo da distrofia retiniana que acomete o homem. Vários são os fatores que podem alterar o ERG tais como: eletrorretinógrafo, fonte de estimulação luminosa, tipo do eletrodo, tempo de adaptação ao escuro, tamanho pupilar, opacidade de meios e protocolo de sedação ou anestesia; além da espécie, raça e idade. Objetivou-se com este estudo padronizar o ERG para cães submetidos à sedação, seguindo o protocolo da International Society for Clinical Electrophysiology of Vision (ISCEV), utilizando Ganzfeld e eletrodos Burian Allen. Foram realizados 233 eletrorretinogramas em cães, 147 fêmeas e 86 machos, com idades entre um e 14 anos. Dos 233 cães examinados, 100 apresentavam catarata em diferentes estágios de maturação, 72 eram diabéticos e apresentavam catarata madura ou hipermadura, 26 apresentaram eletrorretinograma compatível com degeneração retiniana progressiva, três apresentaram eletrorretinograma compatível com síndrome da degeneração retiniana adquirida subitamente e 32 não apresentaram lesão retiniana capaz de atenuar as respostas do ERG, sendo considerados normais quanto à função retiniana. A sedação foi capaz de produzir boa imobilização do paciente sem rotacionar o bulbo ocular, permitindo adequada estimulação retiniana bilateralmente, com auxílio do Ganzfeld. O sistema eletrodiagnóstico Veris registrou com sucesso e simultaneamente de ambos os olhos, as cinco respostas preconizadas pela ISCEV. Como o ERG de campo total tornou-se exame fundamental na rotina oftalmológica, sua padronização é indispensável quando se objetiva comparar resultados de laboratórios distintos...(AU)


Electroretinogram (ERG) is an objective non invasive diagnostic method to evaluate retinal function which permits the early detection of lesions at retinal external layers, even before the appearance of clinical signs. In dogs, ERG is mostly utilized for preoperative evaluation in patients presenting cataracts; characterization of disturbances causing blindness, among the utilization of dogs as animal models in scientific research. Several factors interfere in ERG responses, such as the ERG machine, light stimulation, electrode, time spent on dark adaptation, pupil size, means opacity, sedation or anesthetization, species, breed and age. The purpose of this study was to standardize the full field ERG in sedated dogs, according to the International Society for Clinical Electrophysiology of Vision (ISCEV) protocol, using Ganzfeld and bipolar electrodes. Two hundred thirty threes ERGs were performed in 147 female and 86 male with ages from 1 to 14 years old. Among those 233 dogs, 100 presented cataracts in different stages of maturation, 72 were diabetic and presented mature or hypermature cataracts, 26 presented ERG compatible to progressive retinal degeneration, 3 presented ERG compatible to sudden acquired retinal degeneration syndrome; for 32 dogs no abnormal ERG was registered and they were considered as having normal retinal function. Sedation was capable to induce a good immobilization with no bulb rotation, resulting uniform retinal stimulation, using Ganzfeld. Veris system successfully registered all 5 ISCEV responses, simultaneously from both eyes, at the same time. Full field ERG became a fundamental ophthalmic exam, then, its standardization is mandatory to allow comparison between ERGs from different laboratories. The reliability and reproducibility of this protocol has shown very good responses, using ISCEV protocol, Veris system, Ganzfeld and Burian Allen electrodes in sedated dogs.(AU)


Assuntos
Animais , Retina/lesões , Retina , Retina/cirurgia , Cães
3.
Pesqui. vet. bras ; Pesqui. vet. bras;30(9): 763-769, set. 2010. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-562960

RESUMO

Eletrorretinograma (ERG) é o meio diagnóstico objetivo e não-invasivo para avaliar a função retiniana e detectar precocemente, em várias espécies, lesões nas suas camadas mais externas. As indicações mais comuns para ERG em cães são: avaliação pré-cirúrgica de pacientes com catarata, caracterização de distúrbios que causam cegueira, além de servir como importante modelo para o estudo da distrofia retiniana que acomete o homem. Vários são os fatores que podem alterar o ERG tais como: eletrorretinógrafo, fonte de estimulação luminosa, tipo do eletrodo, tempo de adaptação ao escuro, tamanho pupilar, opacidade de meios e protocolo de sedação ou anestesia; além da espécie, raça e idade. Objetivou-se com este estudo padronizar o ERG para cães submetidos à sedação, seguindo o protocolo da International Society for Clinical Electrophysiology of Vision (ISCEV), utilizando Ganzfeld e eletrodos Burian Allen. Foram realizados 233 eletrorretinogramas em cães, 147 fêmeas e 86 machos, com idades entre um e 14 anos. Dos 233 cães examinados, 100 apresentavam catarata em diferentes estágios de maturação, 72 eram diabéticos e apresentavam catarata madura ou hipermadura, 26 apresentaram eletrorretinograma compatível com degeneração retiniana progressiva, três apresentaram eletrorretinograma compatível com síndrome da degeneração retiniana adquirida subitamente e 32 não apresentaram lesão retiniana capaz de atenuar as respostas do ERG, sendo considerados normais quanto à função retiniana. A sedação foi capaz de produzir boa imobilização do paciente sem rotacionar o bulbo ocular, permitindo adequada estimulação retiniana bilateralmente, com auxílio do Ganzfeld. O sistema eletrodiagnóstico Veris registrou com sucesso e simultaneamente de ambos os olhos, as cinco respostas preconizadas pela ISCEV. Como o ERG de campo total tornou-se exame fundamental na rotina oftalmológica, sua padronização é indispensável quando se objetiva comparar resultados de laboratórios distintos...


Electroretinogram (ERG) is an objective non invasive diagnostic method to evaluate retinal function which permits the early detection of lesions at retinal external layers, even before the appearance of clinical signs. In dogs, ERG is mostly utilized for preoperative evaluation in patients presenting cataracts; characterization of disturbances causing blindness, among the utilization of dogs as animal models in scientific research. Several factors interfere in ERG responses, such as the ERG machine, light stimulation, electrode, time spent on dark adaptation, pupil size, means opacity, sedation or anesthetization, species, breed and age. The purpose of this study was to standardize the full field ERG in sedated dogs, according to the International Society for Clinical Electrophysiology of Vision (ISCEV) protocol, using Ganzfeld and bipolar electrodes. Two hundred thirty threes ERGs were performed in 147 female and 86 male with ages from 1 to 14 years old. Among those 233 dogs, 100 presented cataracts in different stages of maturation, 72 were diabetic and presented mature or hypermature cataracts, 26 presented ERG compatible to progressive retinal degeneration, 3 presented ERG compatible to sudden acquired retinal degeneration syndrome; for 32 dogs no abnormal ERG was registered and they were considered as having normal retinal function. Sedation was capable to induce a good immobilization with no bulb rotation, resulting uniform retinal stimulation, using Ganzfeld. Veris system successfully registered all 5 ISCEV responses, simultaneously from both eyes, at the same time. Full field ERG became a fundamental ophthalmic exam, then, its standardization is mandatory to allow comparison between ERGs from different laboratories. The reliability and reproducibility of this protocol has shown very good responses, using ISCEV protocol, Veris system, Ganzfeld and Burian Allen electrodes in sedated dogs.


Assuntos
Animais , Retina/cirurgia , Retina/lesões , Retina , Cães
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA