Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Gac Med Mex ; 158(4): 216-221, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36256571

RESUMO

INTRODUCTION: In current European guidelines for the management of myocardial infarction after coronary stent placement, there is no consensus on dual antiplatelet therapy (DAPT) ideal duration to prevent stent thrombosis-restenosis without significantly increasing the bleeding risk. OBJECTIVE: To report the percentage of major bleeding and presence of major cardiovascular events associated with prolonged DAPT in patients recruited at the National Institute of Cardiology, treated with primary percutaneous coronary intervention and stent. METHODS: A longitudinal, prospective, observational, non-experimental, descriptive study was carried out. Patients were recruited from November 2016 to December 2017. RESULTS: One hundred and thirty-five patients with a mean age of 57 ± 10 years who completed the three-year follow-up were selected. Obesity and hypertension stood out as the main risk factors. After using DAPT for three years, 3.7% of mortality, 1.48% of major bleeding, and 4.4% of thrombosis-restenosis were recorded. CONCLUSIONS: Prolonged use of DAPT would be justified by the high incidence of thrombosis-restenosis, without a significant increase in bleeding risk, as well as a decrease in major cardiovascular events.


INTRODUCCIÓN: En las guías actuales europeas para el manejo del infarto de miocardio posterior a la colocación de endoprótesis coronaria (stent), no existe consenso sobre la duración ideal de la terapia antiagregante plaquetaria dual (DAPT, dual antiplatelet therapy) para prevenir la trombosis-reestenosis del stent sin aumentar el riesgo significativo de sangrado. OBJETIVO: Reportar el porcentaje de sangrado mayor y de eventos cardiovasculares mayores asociados a la DAPT prolongada en pacientes atendidos en el Instituto Nacional de Cardiología y tratados con intervención coronaria percutánea primaria y stent. MÉTODOS: Se realizó un estudio longitudinal, prospectivo observacional y descriptivo no experimental. Los pacientes fueron captados de noviembre de 2016 a diciembre de 2017. RESULTADOS: Fueron seleccionados 135 pacientes con una media de edad de 57 ± 10 años, quienes cumplieron un seguimiento clínico por tres años. La obesidad y la hipertensión destacaron como principales factores de riesgo. Posterior al uso de DAPT durante tres años, se registró 3.7 % de mortalidad, 1.48 % de sangrado mayor y 4.4 % de trombosis-reestenosis. CONCLUSIONES: El uso prolongado de DAPT estaría justificado por la alta incidencia de trombosis-reestenosis, sin incremento significativo en el riesgo de sangrado y con disminución de los eventos cardiovasculares mayores.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Trombose , Humanos , Pessoa de Meia-Idade , Idoso , Inibidores da Agregação Plaquetária/efeitos adversos , Stents Farmacológicos/efeitos adversos , Estudos Longitudinais , Estudos Prospectivos , Infarto do Miocárdio/epidemiologia , Stents/efeitos adversos , Hemorragia/epidemiologia , Trombose/complicações , Resultado do Tratamento
2.
Arch. cardiol. Méx ; Arch. cardiol. Méx;92(3): 334-341, jul.-sep. 2022. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1393828

RESUMO

Abstract Objective: We evaluated whether cholesteryl ester transfer protein (CETP) gene polymorphisms are associated with the presence of coronary artery disease (CAD) and/or restenosis in patients with coronary stent. Methods: Two polymorphisms of the CETP gene [−971 A/G (rs4783961), and Taq1B A/G (rs708272)] were genotyped by 5'exonuclease TaqMan assays in 219 patients with CAD (66 patients with restenosis and 153 without restenosis) and 607 control individuals. Results: The distribution of polymorphisms was similar in patients with and without restenosis. However, when the whole group of patients (with and without restenosis) was compared to healthy controls, under dominant model, the G allele of the Taq1B A/G polymorphism was associated with increased risk of CAD (odds ratio [OR] = 1.48, pCDom = 0.032). In the same way, under codominant, dominant, and additive models, the A allele of the −971 A/G polymorphisms was associated with an increased risk of developing CAD (OR = 2.03, pCCo-dom = 0.022, OR = 1.83, pCDom = 0.008, and OR = 1.39, pCAdd = 0.011, respectively). In addition, the linkage disequilibrium showed that the "AG" haplotype was associated with increased risk of developing CAD (OR = 1.28, p = 0.03). Conclusion: This study demonstrates that CETP Taq1B A/G and CETP −971 A/G polymorphisms are associated with an increased risk of developing CAD, but no association with restenosis was observed.


Resumen Objetivo: Evaluamos si los polimorfismos del gen CETP están asociados con la presencia de enfermedad arterial coronaria (EAC) y/o restenosis en pacientes con stent coronario. Métodos: En este estudio se genotiparon dos polimorfismos del gen CETP [−971 A/G (rs4783961) y Taq1B A/G (rs708272)] mediante ensayos de 5'exonucleasa TaqMan en 219 pacientes con EAC (66 pacientes con restenosis y 153 sin restenosis), y 607 individuos de control. Resultados: La distribución de polimorfismos fue similar en pacientes con y sin restenosis. Sin embargo, cuando se comparó todo el grupo de pacientes (con y sin restenosis) con controles sanos, bajo el modelo dominante el alelo G del polimorfismo Taq1B A/G se asocia con un mayor riesgo de EAC (OR = 1.48, pCDom = 0.032). De la misma manera, bajo los modelos co-dominante, dominante y aditivo, el alelo A de los polimorfismos −971 A/G se asocia con un mayor riesgo de desarrollar EAC (OR = 2.03, pCCo-dom = 0.022, OR = 1.83, pCDom = 0,008 y OR = 1.39, pCAdd = 0.011, respectivamente). Adicionalmente, el desequilibrio de ligamiento mostró que el haplotipo "AG" se asocia con un mayor riesgo de desarrollar EAC (OR = 1.28, p = 0.03). Conclusión: En resumen, este estudio demuestra que los polimorfismos CETP Taq1B A/G y CETP −971 A/G están asociados con un mayor riesgo de desarrollar CAD, pero no se observó asociación con restenosis.

3.
Gac. méd. Méx ; Gac. méd. Méx;158(4): 225-230, jul.-ago. 2022. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1404844

RESUMO

Resumen Introducción: En las guías actuales europeas para el manejo del infarto de miocardio posterior a la colocación de endoprótesis coronaria (stent), no existe consenso sobre la duración ideal de la terapia antiagregante plaquetaria dual (DAPT, dual antiplatelet therapy) para prevenir la trombosis-reestenosis del stent sin aumentar el riesgo significativo de sangrado. Objetivo: Reportar el porcentaje de sangrado mayor y de eventos cardiovasculares mayores asociados a la DAPT prolongada en pacientes atendidos en el Instituto Nacional de Cardiología y tratados con intervención coronaria percutánea primaria y stent. Métodos: Se realizó un estudio longitudinal, prospectivo observacional y descriptivo no experimental. Los pacientes fueron captados de noviembre de 2016 a diciembre de 2017. Resultados: Fueron seleccionados 135 pacientes con una media de edad de 57 ± 10 años, quienes cumplieron un seguimiento clínico por tres años. La obesidad y la hipertensión destacaron como principales factores de riesgo. Posterior al uso de DAPT durante tres años, se registró 3.7 % de mortalidad, 1.48 % de sangrado mayor y 4.4 % de trombosis-reestenosis. Conclusiones: El uso prolongado de DAPT estaría justificado por la alta incidencia de trombosis-reestenosis, sin incremento significativo en el riesgo de sangrado y con disminución de los eventos cardiovasculares mayores.


Abstract Introduction: In current European guidelines for the management of myocardial infarction after coronary stent placement, there is no consensus on dual antiplatelet therapy (DAPT) ideal duration to prevent stent thrombosis-restenosis without significantly increasing the bleeding risk. Objective: To report the percentage of major bleeding and presence of major cardiovascular events associated with prolonged DAPT in patients recruited at the National Institute of Cardiology, treated with primary percutaneous coronary intervention and stent. Methods: A longitudinal, prospective, observational, non-experimental, descriptive study was carried out. Patients were recruited from November 2016 to December 2017. Results: One-hundred and thirty-five patients with a mean age of 57 ± 10 years who completed the three-year follow-up were selected. Obesity and hypertension stood out as the main risk factors. After using DAPT for three years, 3.7% of mortality, 1.48% of major bleeding, and 4.4% of thrombosis-restenosis were recorded. Conclusions: Prolonged use of DAPT would be justified by the high incidence of thrombosis-restenosis, without a significant increase in bleeding risk, as well as a decrease in major cardiovascular events.

4.
Arch Cardiol Mex ; 92(3): 334-341, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34594055

RESUMO

OBJECTIVE: We evaluated whether cholesteryl ester transfer protein (CETP) gene polymorphisms are associated with the presence of coronary artery disease (CAD) and/or restenosis in patients with coronary stent. METHODS: Two polymorphisms of the CETP gene [-971 A/G (rs4783961), and Taq1B A/G (rs708272)] were genotyped by 5'exonuclease TaqMan assays in 219 patients with CAD (66 patients with restenosis and 153 without restenosis) and 607 control individuals. RESULTS: The distribution of polymorphisms was similar in patients with and without restenosis. However, when the whole group of patients (with and without restenosis) was compared to healthy controls, under dominant model, the G allele of the Taq1B A/G polymorphism was associated with increased risk of CAD (odds ratio [OR] = 1.48, pCDom = 0.032). In the same way, under codominant, dominant, and additive models, the A allele of the -971 A/G polymorphisms was associated with an increased risk of developing CAD (OR = 2.03, pCCo-dom = 0.022, OR = 1.83, pCDom = 0.008, and OR = 1.39, pCAdd = 0.011, respectively). In addition, the linkage disequilibrium showed that the "AG" haplotype was associated with increased risk of developing CAD (OR = 1.28, p = 0.03). CONCLUSION: This study demonstrates that CETP Taq1B A/G and CETP -971 A/G polymorphisms are associated with an increased risk of developing CAD, but no association with restenosis was observed.


OBJETIVO: Evaluamos si los polimorfismos del gen CETP están asociados con la presencia de enfermedad arterial coronaria (EAC) y/o restenosis en pacientes con stent coronario. MÉTODOS: En este estudio se genotiparon dos polimorfismos del gen CETP [−971 A/G (rs4783961) y Taq1B A/G (rs708272)] mediante ensayos de 5'exonucleasa TaqMan en 219 pacientes con EAC (66 pacientes con restenosis y 153 sin restenosis), y 607 individuos de control. RESULTADOS: La distribución de polimorfismos fue similar en pacientes con y sin restenosis. Sin embargo, cuando se comparó todo el grupo de pacientes (con y sin restenosis) con controles sanos, bajo el modelo dominante el alelo G del polimorfismo Taq1B A/G se asocia con un mayor riesgo de EAC (OR = 1.48, pCDom = 0.032). De la misma manera, bajo los modelos co-dominante, dominante y aditivo, el alelo A de los polimorfismos −971 A/G se asocia con un mayor riesgo de desarrollar EAC (OR = 2.03, pCCo-dom = 0.022, OR = 1.83, pCDom = 0,008 y OR = 1.39, pCAdd = 0.011, respectivamente). Adicionalmente, el desequilibrio de ligamiento mostró que el haplotipo "AG" se asocia con un mayor riesgo de desarrollar EAC (OR = 1.28, p = 0.03). CONCLUSIÓN: En resumen, este estudio demuestra que los polimorfismos CETP Taq1B A/G y CETP −971 A/G están asociados con un mayor riesgo de desarrollar CAD, pero no se observó asociación con restenosis.


Assuntos
Proteínas de Transferência de Ésteres de Colesterol , Doença da Artéria Coronariana , Proteínas de Transferência de Ésteres de Colesterol/genética , Doença da Artéria Coronariana/genética , Genótipo , Humanos , Desequilíbrio de Ligação , Polimorfismo de Nucleotídeo Único , Stents
5.
Arch Cardiol Mex ; 92(1): 36-41, 2022 01 03.
Artigo em Espanhol | MEDLINE | ID: mdl-34161313

RESUMO

Introduction: Heart failure (HF) is a chronic disease that acutely and progressively reduces physical functionality. The patient commonly suffers from intermittent relapses that increase the likelihood of comorbidities such as chronic insomnia, cognitive impairment, alterations in sexual response, psychological distress, symptoms of anxiety and depression disorder, and decreased self-care behaviors. The objective of this study was to identify the main needs for psychological support in patients with HF. Methodology: A descriptive, cross-sectional and analytical study was carried out. Participants were selected through consecutive non-probability samples. 150 patients with a diagnosis of HF who attended the Specialized Center for Heart Failure at the National Institute of Cardiology "Ignacio Chávez" were evaluated from November 2018 to April 2019, applying the inventories: Quality of life in patients with HF (Minnesota), Hospital Anxiety and Depression Scale (HADS), psychological distress thermometer (visual analog scale) and the HF Patient Information Needs Inventory. Results: 33% of the patients perceive a high level of psychological distress that requires immediate assistance and 26.6% report a medium level that requires monitoring. The main information needs reported by the patients were information on taking medications (53.7%) and managing psychological distress (43.9%). Conclusion: Active assessment of psychological distress and unmet information needs is relevant in patients with heart failure, thus highlighting the importance of their identification and the correct design and application of evidence-based interventions aimed at their resolution.


Introducción: La insuficiencia cardiaca crónica (ICC) es una enfermedad que reduce de manera aguda y progresiva la funcionalidad física. El paciente comúnmente sufre de recaídas intermitentes que aumentan la probabilidad de comorbilidades como insomnio crónico, deterioro cognitivo, alteraciones en la respuesta sexual, estrés psicológico, síntomas de trastorno de ansiedad y depresión y disminución de las conductas de autocuidado. Objetivo: Identificar las principales necesidades de apoyo psicológico en pacientes con IC. Metodología: Se realizó un estudio descriptivo, transversal y analítico. Se evaluaron 150 pacientes con ICC del Centro Especializado en Insuficiencia Cardiaca del Instituto Nacional de Cardiología Ignacio Chávez de noviembre de 2018 a abril de 2019. Se aplicaron los inventarios: Calidad de vida en pacientes con IC (Minnesota), Escala de Ansiedad y Depresión Hospitalaria (HADS), termómetro del distrés psicológico (escala analógica visual) y el Inventario de Necesidades de Información del Paciente con IC. Resultados: Treinta y tres por ciento de los pacientes perciben un nivel alto de distrés psicológico que requiere asistencia inmediata y el 26.6% reporta un nivel medio que requiere monitoreo. Las principales necesidades de información reportadas por los pacientes fueron información sobre la toma de medicamentos (53.7%) y manejo del estrés psicológico (43.9%). Conclusión: En pacientes con IC es relevante la valoración activa de distrés psicológico y necesidades de información no cubiertas, resaltando de este modo la importancia de su identificación y el correcto diseño y aplicación de intervenciones basadas en la evidencia enfocadas a su resolución.


Assuntos
Insuficiência Cardíaca , Transtornos Mentais , Angústia Psicológica , Disfunção Ventricular , Estudos Transversais , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Qualidade de Vida , Inquéritos e Questionários
6.
Arch Cardiol Mex ; 90(2): 142-147, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32897265

RESUMO

In this paper, we describe our coronary stent (INC-1) design and development, the way that we found the specific characteristics needed for our device including biophysics aspects, design, finite element testing, manufacturing, and mechanic trials, we submitted and animal models experiences. The stent platform was cobalt-chromium L605 (Co-Cr), with struts thickness of 80 µm, balloon expandable. We placed the coronary stent INC-1 on a rabbit and dog models so we can evaluate efficacy and security of the device in relationship to its biomechanical properties including navigation capacity, traceability, symmetric expansion, and safety, as well as endothelial attachment, thrombogenicity, and lack of involvement of secondary branches in these models. We succeeded in efficacy and safety of the device after fluoroscopy-guided implant proving excellent capacity of release system, traceability, fluoroscopic visualization, symmetric expansion, and complete endothelial attach. Furthermore, we obtained a good post-implant balloon withdrawal, functional integrity, and no vascular complications. We observed adequate clinical evolution 3 weeks after the stent implantation.


En esta publicación se describen el diseño y el desarrollo de un stent coronario (INC-1), la forma en que se determinaron las características biofísicas deseadas, el diseño y las pruebas computacionales por elemento finito, su fabricación, así como las pruebas mecánicas a las que se sometió el prototipo y por último las primeras experiencias en modelos animales. La plataforma del stent desarrollado fue de cobalto y cromo L605 (Co-Cr), con struts de 80 µm de grosor, expandido por balón. La colocación del stent coronario INC-1 se realizó en un modelo de conejo y uno canino con el objetivo de evaluar el éxito técnico y de seguridad del stent en relación con las propiedades biomecánicas (capacidad de navegación, maniobrabilidad, expansión simétrica del stent) y de seguridad (fijación a la pared vascular y ausencia de compromiso de ramas secundarias y formación de trombos en el momento de la colocación del stent en el modelo animal). Se obtuvo éxito técnico y de seguridad del stent después del implante guiado por fluoroscopia, lo que demostró adecuada capacidad del sistema liberador, excelente maniobrabilidad, adecuada visualización fluoroscópica, expansión simétrica y fijación completa a la pared vascular, capacidad para retirar el balón desinflado después del implante, e integridad funcional y sin complicaciones vasculares. La evolución clínica fue favorable a tres semanas del seguimiento planeado.


Assuntos
Vasos Coronários/cirurgia , Desenho de Prótese , Stents , Animais , Ligas de Cromo/química , Doença da Artéria Coronariana/cirurgia , Cães , Fluoroscopia , Humanos , Modelos Animais , Coelhos
7.
Gac Med Mex ; 156(4): 279-285, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32831335

RESUMO

INTRODUCTION: A drug-eluting coronary stent is being developed at the National Institute of Cardiology of Mexico for the treatment of ischemic heart disease. OBJECTIVE: To establish the best animal model for the tests, to show the advances in the drug-eluting stent prototype, to assess two drugs' antiproliferative activity and histological results. METHOD: Smooth muscle cell culture tests were performed in order to assess sirolimus and paclitaxel antiproliferative properties. The drugs were encapsulated inside the polymeric matrix of the stents. Rabbits and pigs were used as animal models. RESULTS: Sirolimus and paclitaxel showed an inhibitory effect, which was higher for the latter. Infrared spectroscopy and light and optical microscopy showed that the drug/polymer layer properly adhered to the stent. At a four-week follow-up, both animal models showed satisfactory clinical evolution and adequate histological response, although the porcine model was shown to be more suitable for future protocols. CONCLUSIONS: Preliminary tests of the drug-eluting stent provided bases for the development of a study protocol with an adequate number of pigs and with clinical angiographic and histopathological three-month follow-up.


INTRODUCCIÓN: En el Instituto Nacional de Cardiología de México se desarrolla una endoprótesis (stent) coronaria liberadora de fármacos para el tratamiento de la cardiopatía isquémica. OBJETIVO: Establecer el mejor modelo animal para las pruebas, mostrar los avances en el prototipo del stent liberador de fármacos, evaluar la actividad antiproliferativa de dos fármacos y los resultados histológicos. MÉTODO: Se realizaron cultivos de células de músculo liso para evaluar las propiedades antiproliferativas de sirolimus y paclitaxel. Los fármacos fueron encapsulados en el interior de la matriz polimérica de los stents. Se emplearon conejos y cerdos como modelos animales. RESULTADOS: Sirolimus y paclitaxel mostraron efecto inhibitorio, mayor en el segundo. La espectroscopia infrarroja y la microscopia óptica y electrónica mostraron que la capa del polímero con el fármaco se adhería adecuadamente al stent. A las cuatro semanas de seguimiento, ambos modelos animales mostraron evolución clínica satisfactoria y adecuada respuesta histológica, si bien el modelo porcino resultó más conveniente para protocolos futuros. CONCLUSIONES: Las pruebas preliminares del stent liberador de fármaco brindó bases para desarrollar el protocolo con un número adecuado en cerdos y con seguimiento clínico angiográfico e histopatológico a tres meses.


Assuntos
Stents Farmacológicos , Paclitaxel/administração & dosagem , Sirolimo/administração & dosagem , Animais , Modelos Animais de Doenças , Feminino , Seguimentos , Masculino , Microscopia , Desenho de Prótese , Coelhos , Espectrofotometria Infravermelho , Suínos
8.
Gac. méd. Méx ; Gac. méd. Méx;156(4): 276-282, Jul.-Aug. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1249911

RESUMO

Abstract Introduction: A drug-eluting coronary stent is being developed at the National Institute of Cardiology of Mexico for the treatment of ischemic heart disease. Objective: To establish the best animal model for the tests, to show the advances in the drug-eluting stent prototype, to assess two drugs’ antiproliferative activity and histological results. Method: Smooth muscle cell culture tests were performed in order to assess sirolimus and paclitaxel antiproliferative properties. The drugs were encapsulated inside the polymeric matrix of the stents. Rabbits and pigs were used as animal models. Results: Sirolimus and paclitaxel showed an inhibitory effect, which was higher for the latter. Infrared spectroscopy and light and optical microscopy showed that the drug/polymer layer properly adhered to the stent. At a four-week follow-up, both animal models showed satisfactory clinical evolution and adequate histological response, although the porcine model was shown to be more suitable for future protocols. Conclusions: Preliminary tests of the drug-eluting stent provided bases for the development of a study protocol with an adequate number of pigs and with clinical angiographic and histopathological three-month follow-up.


Resumen Introducción: En el Instituto Nacional de Cardiología de México se desarrolla una endoprótesis (stent) coronaria liberadora de fármacos para el tratamiento de la cardiopatía isquémica. Objetivo: Establecer el mejor modelo animal para las pruebas, mostrar los avances en el prototipo del stent liberador de fármacos, evaluar la actividad antiproliferativa de dos fármacos y los resultados histológicos. Método: Se realizaron cultivos de células de músculo liso para evaluar las propiedades antiproliferativas de sirolimus y paclitaxel. Los fármacos fueron encapsulados en el interior de la matriz polimérica de los stents. Se emplearon conejos y cerdos como modelos animales. Resultados: Sirolimus y paclitaxel mostraron efecto inhibitorio, mayor en el segundo. La espectroscopia infrarroja y la microscopia óptica y electrónica mostraron que la capa del polímero con el fármaco se adhería adecuadamente al stent. A las cuatro semanas de seguimiento, ambos modelos animales mostraron evolución clínica satisfactoria y adecuada respuesta histológica, si bien el modelo porcino resultó más conveniente para protocolos futuros. Conclusiones: Las pruebas preliminares del stent liberador de fármaco brindó bases para desarrollar el protocolo con un número adecuado en cerdos y con seguimiento clínico angiográfico e histopatológico a tres meses.


Assuntos
Animais , Masculino , Feminino , Coelhos , Paclitaxel/administração & dosagem , Sirolimo/administração & dosagem , Stents Farmacológicos , Desenho de Prótese , Espectrofotometria Infravermelho , Suínos , Seguimentos , Modelos Animais de Doenças , Microscopia
9.
Arch. cardiol. Méx ; Arch. cardiol. Méx;90(2): 142-147, Apr.-Jun. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1131023

RESUMO

Abstract In this paper, we describe our coronary stent (INC-1) design and development, the way that we found the specific characteristics needed for our device including biophysics aspects, design, finite element testing, manufacturing, and mechanic trials, we submitted and animal models experiences. The stent platform was cobalt-chromium L605 (Co-Cr), with struts thickness of 80 μm, balloon expandable. We placed the coronary stent INC-1 on a rabbit and dog models so we can evaluate efficacy and security of the device in relationship to its biomechanical properties including navigation capacity, traceability, symmetric expansion, and safety, as well as endothelial attachment, thrombogenicity, and lack of involvement of secondary branches in these models. We succeeded in efficacy and safety of the device after fluoroscopy-guided implant proving excellent capacity of release system, traceability, fluoroscopic visualization, symmetric expansion, and complete endothelial attach. Furthermore, we obtained a good post-implant balloon withdrawal, functional integrity, and no vascular complications. We observed adequate clinical evolution 3 weeks after the stent implantation.


Resumen En esta publicación se describen el diseño y el desarrollo de un stent coronario (INC-1), la forma en que se determinaron las características biofísicas deseadas, el diseño y las pruebas computacionales por elemento finito, su fabricación, así como las pruebas mecánicas a las que se sometió el prototipo y por último las primeras experiencias en modelos animales. La plataforma del stent desarrollado fue de cobalto y cromo L605 (Co-Cr), con struts de 80 μm de grosor, expandido por balón. La colocación del stent coronario INC-1 se realizó en un modelo de conejo y uno canino con el objetivo de evaluar el éxito técnico y de seguridad del stent en relación con las propiedades biomecánicas (capacidad de navegación, maniobrabilidad, expansión simétrica del stent) y de seguridad (fijación a la pared vascular y ausencia de compromiso de ramas secundarias y formación de trombos en el momento de la colocación del stent en el modelo animal). Se obtuvo éxito técnico y de seguridad del stent después del implante guiado por fluoroscopia, lo que demostró adecuada capacidad del sistema liberador, excelente maniobrabilidad, adecuada visualización fluoroscópica, expansión simétrica y fijación completa a la pared vascular, capacidad para retirar el balón desinflado después del implante, e integridad funcional y sin complicaciones vasculares. La evolución clínica fue favorable a tres semanas del seguimiento planeado.


Assuntos
Humanos , Animais , Cães , Coelhos , Desenho de Prótese , Stents , Vasos Coronários/cirurgia , Doença da Artéria Coronariana/cirurgia , Fluoroscopia , Ligas de Cromo/química , Modelos Animais
10.
Arch Cardiol Mex ; 90(2): 163-168, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32459214

RESUMO

In this paper we describe our coronary stent (INC-1) design and development, the way that we found the specific characteristics needed for our device including biophysics aspects, design, finite element testing, manufacturing and mechanic trials we submitted and animal models experiences. The stent platform was cobalt-chromium L605 (Co-Cr), with struts thickness of 80 µm, balloon expandable. We placed the coronary stent INC-1 on a rabbit and dog models so we can evaluate efficacy and security of the device in relationship to its biomechanical properties including navigation capacity, traceability, symmetric expansion and safety. As well as endothelial attachment, thrombogenicity and lack of involvement of secondary branches in these models. We succeeded in efficacy and safety of the device after fluoroscopy-guided implant proving excellent capacity of release system, traceability, fluoroscopic visualization, symmetric expansion and complete endothelial attach. Also, we obtained a good post-implant balloon withdrawal, functional integrity and no vascular complications. We observed adequate clinical evolution 3 weeks after the stent implantation.


En esta publicación se describen el diseño y el desarrollo de un stent coronario (INC-1), la forma en que se determinaron las características biofísicas deseadas, el diseño y las pruebas computacionales por elemento finito, su fabricación, así como las pruebas mecánicas a las que se sometió el prototipo y por último las primeras experiencias en modelos animales. La plataforma del stent desarrollado fue de cobalto y cromo L605 (Co-Cr), con struts de 80 µm de grosor, expandido por balón. La colocación del stent coronario INC-1 se realizó en un modelo de conejo y uno canino con el objetivo de evaluar el éxito técnico y de seguridad del stent en relación con las propiedades biomecánicas (capacidad de navegación, maniobrabilidad, expansión simétrica del stent) y de seguridad (fijación a la pared vascular y ausencia de compromiso de ramas secundarias y formación de trombos en el momento de la colocación del stent en el modelo animal). Se obtuvo éxito técnico y de seguridad del stent después del implante guiado por fluoroscopia, lo que demostró adecuada capacidad del sistema liberador, excelente maniobrabilidad, adecuada visualización fluoroscópica, expansión simétrica y fijación completa a la pared vascular, capacidad para retirar el balón desinflado después del implante, e integridad funcional y sin complicaciones vasculares. La evolución clínica fue favorable a tres semanas del seguimiento planeado.


Assuntos
Doença da Artéria Coronariana/cirurgia , Desenho de Prótese , Stents , Animais , Modelos Animais de Doenças , Cães , Fluoroscopia , Humanos , Coelhos
11.
Rev Invest Clin ; 72(1): 32-36, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32132738

RESUMO

BACKGROUND: The cost of performing a percutaneous coronary intervention is considerably high for the patient as well as for health systems, which have promoted the development of local technology to help meet the need for these devices. METHODS: The INC-01 bare-metal stent was developed at the National Institute of Cardiology in Mexico City and was first implanted on porcine models with technical success in 100% of the evaluated parameters. PRESENTATION OF CASES: We present the first three cases of patients with ischemic heart disease, to whom the INC-01 bare-metal stent was implanted. Intracoronary ultrasonography was performed post-stent implantation, showing all the characteristics of implant success during evaluation and clinical follow-up. CONCLUSIONS: Angiography and intracoronary ultrasound were carried out demonstrating that the INC-01 bare-metal stent has physical, biological, and histological characteristics similar to those found in commercial metallic stents.


Assuntos
Isquemia Miocárdica/cirurgia , Desenho de Prótese , Stents , Adulto , Idoso , Seguimentos , Humanos , Masculino , México , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/fisiopatologia , Projetos Piloto , Resultado do Tratamento , Ultrassonografia
12.
Rev Invest Clin ; 72(1): 19-24, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32132739

RESUMO

BACKGROUND: Previous studies have shown an association between polymorphisms of the BAT1-NF-κB inhibitor-like-1 (NFKBIL1)-LTA genomic region and susceptibility to myocardial infarction and acute coronary syndrome (ACS). OBJECTIVE: The objective of the study was to study the role of three polymorphisms in the BAT1, NFKBIL1, and LTA genes on the susceptibility or protection against ACS; we included a group of cases-controls from Central Mexico. METHODS: The BAT1 rs2239527C/G, NFKBIL1 rs2071592T/A, and LTA rs1800683G/A polymorphisms were genotyped using a 5' TaqMan assay in a group of 625 patients with ACS and 617 healthy controls. RESULTS: Under a recessive model, the BAT1 -23C/G (rs2239527) polymorphism showed an association with protection against ACS (odds ratio = 0.56, and p-corrected = 0.019). In contrast, the genotype and allele frequencies of the NFKBIL1 rs2071592T/A and LTA rs1800683G/A polymorphisms were similar between ACS patients and controls and no association was identified. CONCLUSION: Our data suggest an association between the BAT1 -23C/G polymorphism and protection against ACS in Mexican patients.


Assuntos
Síndrome Coronariana Aguda/genética , RNA Helicases DEAD-box/genética , Infarto do Miocárdio/genética , Proteínas Adaptadoras de Transdução de Sinal/genética , Idoso , Estudos de Casos e Controles , Feminino , Frequência do Gene , Predisposição Genética para Doença , Genótipo , Humanos , Linfotoxina-alfa/genética , Masculino , México , Pessoa de Meia-Idade , Polimorfismo de Nucleotídeo Único
13.
Rev. invest. clín ; Rev. invest. clín;72(1): 19-24, Jan.-Feb. 2020. tab
Artigo em Inglês | LILACS | ID: biblio-1251830

RESUMO

ABSTRACT Background: Previous studies have shown an association between polymorphisms of the BAT1-NF-κB inhibitor-like-1 (NFKBIL1)-LTA genomic region and susceptibility to myocardial infarction and acute coronary syndrome (ACS). Objective: The objective of the study was to study the role of three polymorphisms in the BAT1, NFKBIL1, and LTA genes on the susceptibility or protection against ACS; we included a group of cases-controls from Central Mexico. Methods: The BAT1 rs2239527C/G, NFKBIL1 rs2071592T/A, and LTA rs1800683G/A polymorphisms were genotyped using a 5' TaqMan assay in a group of 625 patients with ACS and 617 healthy controls. Results: Under a recessive model, the BAT1 -23C/G (rs2239527) polymorphism showed an association with protection against ACS (odds ratio = 0.56, and p-corrected = 0.019). In contrast, the genotype and allele frequencies of the NFKBIL1 rs2071592T/A and LTA rs1800683G/A polymorphisms were similar between ACS patients and controls and no association was identified. Conclusion: Our data suggest an association between the BAT1 -23C/G polymorphism and protection against ACS in Mexican patients.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , RNA Helicases DEAD-box/genética , Síndrome Coronariana Aguda/genética , Infarto do Miocárdio/genética , Estudos de Casos e Controles , Linfotoxina-alfa/genética , Predisposição Genética para Doença , Polimorfismo de Nucleotídeo Único , Proteínas Adaptadoras de Transdução de Sinal/genética , Frequência do Gene , Genótipo , México
14.
Rev. invest. clín ; Rev. invest. clín;72(1): 32-36, Jan.-Feb. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1251832

RESUMO

ABSTRACT Background: The cost of performing a percutaneous coronary intervention is considerably high for the patient as well as for health systems, which have promoted the development of local technology to help meet the need for these devices. Methods: The INC-01 bare-metal stent was developed at the National Institute of Cardiology in Mexico City and was first implanted on porcine models with technical success in 100% of the evaluated parameters. Presentation of Cases: We present the first three cases of patients with ischemic heart disease, to whom the INC-01 bare-metal stent was implanted. Intracoronary ultrasonography was performed post-stent implantation, showing all the characteristics of implant success during evaluation and clinical follow-up. Conclusions: Angiography and intracoronary ultrasound were carried out demonstrating that the INC-01 bare-metal stent has physical, biological, and histological characteristics similar to those found in commercial metallic stents.


Assuntos
Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Desenho de Prótese , Stents , Isquemia Miocárdica/cirurgia , Projetos Piloto , Seguimentos , Ultrassonografia , Resultado do Tratamento , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/diagnóstico por imagem , México
15.
Future Cardiol ; 16(1): 53-60, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31850802

RESUMO

Aim: To determine the effectiveness of Centro Nacional de Investigaciones Cardiovasculares (CNIC)-polypill (acetylsalicylic acid 100 mg, ramipril 5/10 mg, simvastatin 40 mg) in achieving blood pressure (BP) goals. Patients & methods: A multicenter, observational, one cohort, prospective study. BP targets were analyzed in patients with cardiovascular disease after 12-months treatment with the CNIC polypill. Results: A total of 572 patients (59.4 ± 13.9 years, 57.3% men) were analyzed. At baseline, BP was 147.1 ± 18.1/88.3 ± 10.6 mmHg, 97.1% of patients were taken renin-angiotensin system inhibitors, 5.4% calcium antagonists, 1.9% diuretics and 13.1% ß-blockers. The proportion of patients who achieved BP targets increased from 20.1 to 55.4% (p < 0.001). Conclusion: In routine practice, switching from usual care to the CNIC-polypill in patients with cardiovascular disease could facilitate achieving BP goals.


Assuntos
Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Pressão Sanguínea/efeitos dos fármacos , Bloqueadores dos Canais de Cálcio/uso terapêutico , Doenças Cardiovasculares/tratamento farmacológico , Diuréticos/uso terapêutico , Doenças Cardiovasculares/epidemiologia , Combinação de Medicamentos , Feminino , Humanos , Masculino , México , Pessoa de Meia-Idade , Morbidade/tendências , Estudos Prospectivos , Resultado do Tratamento
19.
JACC Clin Electrophysiol ; 3(11): 1321-1329, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-29759631

RESUMO

OBJECTIVES: This cumulative case study was performed to properly address the possible mechanisms, forms, and consequences of "twiddler's," "reel," and "ratchet" syndromes. BACKGROUND: Twiddler's, reel, and ratchet syndromes are rare entities responsible for lead displacement of cardiac implantable electronic devices (CIED). METHODS: From 2007 to 2012, 1,472 CIED were implanted at our center. Eighty-nine cases were reviewed for failure of pacing circuit integrity. Only 9 met the inclusion criteria for idiopathic lead migration (ILM) and were grouped as ILM (twiddler) or ILM (reel). For a pooled analysis of cases, a review of the literature from 1990 to 2012 was performed, and the authors identified 78 cases from 64 publications. RESULTS: The study population consisted of 87 cases (45 women; median age, 66 years; 46 with ILM [twiddler] and 41 with ILM [reel]). Migration affected only 1 lead in 65% of 46 devices with more than 1 lead. None of the previously reported risk factors-manual manipulation of the device, elderly age, obesity, oversized pocket, and psychiatric history-correlated with the risk of ILM. CONCLUSIONS: Neither manual manipulation of the device nor the other traditional risk factors reported in the literature for ILM syndrome correlated with the risk of ILM.


Assuntos
Eletrodos Implantados/efeitos adversos , Falha de Equipamento/estatística & dados numéricos , Migração de Corpo Estranho/etiologia , Marca-Passo Artificial/efeitos adversos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Desfibriladores Implantáveis/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/estatística & dados numéricos , Fatores de Risco , Síndrome , Adulto Jovem
20.
Arch. cardiol. Méx ; Arch. cardiol. Méx;83(4): 257-262, oct.-dic. 2013. tab
Artigo em Inglês | LILACS | ID: lil-703026

RESUMO

Objective: The objective of this study was to establish the role of the TLR-4 gene polymorphisms in individuals in risk of developing ACS. Methods: The study included 457 Mexican patients with ACS and 283 control individuals. The TLR-4 Asp299Gly and TLR-4 Thr399Ile single nucleotide polymorphisms were genotyped using 5' exonuclease TaqMan genotyping assays on an 7900HT Fast real-time PCR system according to manufacturer's instructions (Applied Biosystems, Foster City, USA). Results: The results obtained in this study showed that the frequency of the two polymorphisms (TLR-4 Asp299Gly and TLR-4 Thr399Ile) studied were similar between patients with ACS and healthy controls. Multiple logistic regression analysis showed that the largest risk factor for ACS development was given by smoking (11.88-fold increased risk), hypertension (4.32-fold increased risk), type II diabetes (3.44-fold increased risk), gender (2.32-fold increased risk), and dyslipidemia (1.52-fold increased risk). Conclusion: The Asp299Gly and Thr399Ile polymorphisms were not associated with susceptibility to ACS in the Mexican population.


Objetivo: El objetivo de este estudio fue establecer el papel de los polimorfismos del gen TLR-4 en individuos en riesgo de desarrollar síndrome coronario agudo (SCA). Métodos: El estudio incluyó a 457 pacientes mexicanos con SCA y 283 individuos como grupo control. Los polimorfismos de un solo nucleótido TLR-4 Asp299Gly y TLR-4 Thr399Ile fueron determinados usando ensayos TaqMan 5' exonucleasa en un equipo tiempo real 7900HT (Fast real-time PCR system) de acuerdo con instrucciones del fabricante Applied Biosystems, Foster City, EE.UU. Resultados: Los resultados obtenidos mostraron que las frecuencias de los 2 polimorfismos (TLR-4Asp299Gly y TLR-4 Thr399Ile) estudiados fueron similares entre pacientes con SCA e individuos control. No obstante, el análisis de regresión logística mostró que los factores de mayor riesgo para desarrollar SCA se debieron a tabaquismo (incrementa 11.88 veces el riesgo), hipertensión (incrementa 4.32 veces el riesgo), diabetes tipo 2 (incrementa 3.44 veces el riesgo), género (incrementa 2.32 veces el riesgo), y la dislipidemia (incrementa 1.52 veces el riesgo). Conclusión: Determinamos que los polimorfismos Asp299Gly y Thr399Ile no se asocian con la susceptibilidad al SCA en la población mexicana.


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Síndrome Coronariana Aguda/genética , Polimorfismo de Nucleotídeo Único , /genética , México , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA