Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Prosthet Dent ; 127(2): 295-301, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33243473

RESUMO

STATEMENT OF PROBLEM: Whether ultrasonic activation of the adhesive system improves dentin tubule penetration and the bond strength of fiber posts to root dentin is unclear. PURPOSE: The purpose of this in vitro study was to evaluate the effect of ultrasonic activation of 2 adhesive systems (etch-and-rinse and self-etch) and 1 glass ionomer cement on the dentin tubule penetration and pushout bond strength of fiber posts to root dentin. MATERIAL AND METHODS: Sixty maxillary central incisors were endodontically treated and divided into 6 groups (n=10) as per the post cementation strategy: etch-and-rinse, etch-and-rinse and ultrasonic, self-etch, self-etch and ultrasonic, glass ionomer cement, and glass ionomer cement and ultrasonic. The primers, the adhesives, and the glass ionomer cement were activated for 20 seconds each, and the fiber posts were cemented with a resin cement. Dentin tubule penetration was evaluated by confocal laser scanning microscopy and the pushout bond strength measured at 3 post locations: cervical, middle, and apical. The failure patterns were also described after pushout testing. RESULTS: Self-etch and ultrasonic showed higher dentin tubule penetration than the other cementation strategies (P<.05) and improved the bond strength values (P<.05), which were higher than etch-and-rinse and ultrasonic and glass ionomer cement and ultrasonic (P<.05). Adhesive failures at the cement and dentin interface were predominant in the etch-and-rinse, self-etch, and self-etch and ultrasonic groups. CONCLUSIONS: Ultrasonic activation improved the dentin tubule penetration of a self-etch adhesive system. The bond strength of fiber posts cemented with a self-etch adhesive system and a resin cement was improved after ultrasonic activation.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Cimentos Dentários/farmacologia , Cimentos Dentários/uso terapêutico , Dentina , Teste de Materiais , Cimentos de Resina/química , Cimentos de Resina/uso terapêutico , Ultrassom
2.
J Endod ; 44(9): 1425-1429, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30078572

RESUMO

INTRODUCTION: This study compared the cyclic fatigue and the canal transportation promoted by Twisted File (TF) Adaptive and Navigator EVO systems when used with 2 different motions. METHODS: Forty mesiobuccal roots of maxillary molars were scanned by using micro-computed tomography imaging before and after root canal preparation with the 2 instrument systems used with 2 motions (adaptive and continuous rotation). Samples were divided into 4 groups: TFA, TF Adaptive instruments under adaptive motion; TFC, TF Adaptive instruments under continuous motion; NA, Navigator instruments under adaptive motion; and NC, Navigator instruments under continuous motion. Root canals were prepared until 35.04 instruments. Apical transportation was analyzed by using micro-computed tomography at 3 levels: 3, 6, and 9 mm from the apex. The cyclic fatigue tests were performed by using a custom-made device. Ten instruments of each brand were activated by using a 6:1 reduction handpiece powered by a torque-controlled motor using the preset programs "custom mode" and "TF Adaptive" to activate 25.06 and 35.04 instruments. Kruskal-Wallis and Dunn tests were used to assess canal transportation, centering ability, and canal volume. The Student t test was used to evaluate cyclic fatigue (P = .05). RESULTS: At 3 and 9 mm, the canal transportation and centering ability were similar in all groups (P > .05). At 6 mm, TFC presented higher canal transportation toward furcal region than NA and NC (P < .05). After canal preparation, TFA promoted great dentinal excision, presenting higher canal volume than NA and NC (P < .05). Higher cyclic fatigue resistance was observed under continuous than adaptive motion regardless of system or tip/diameter of the instrument (P < .05). CONCLUSIONS: Both systems can be used under adaptive or continuous rotation. However, the life span of the instruments was higher when used under continuous rotation. Small canal transportation occurred when mesiobuccal root canals from maxillary molars were prepared until 35.04 instruments.


Assuntos
Análise de Falha de Equipamento , Falha de Equipamento , Obturação do Canal Radicular/instrumentação , Preparo de Canal Radicular/instrumentação , Ligas , Humanos , Movimento (Física) , Rotação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA