Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Endoscopy ; 48(6): 516-20, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26981619

RESUMO

BACKGROUND AND STUDY AIMS: Ring complications after a banded Roux-en-Y gastric bypass (RYGB) are usually managed surgically. The aim of this study was to analyze the safety and effectiveness of endoscopic removal of noneroded rings after banded-RYGB, by inducing intragastric erosion of the ring using a self-expandable plastic stent (SEPS). PATIENTS AND METHODS: A total of 41 patients with banded RYGB who had noneroded rings and food intolerance were prospectively enrolled. Patients were treated with endoscopic SEPS placement and ring removal. Data from time of stenting, resolution of symptoms, need for endoscopic dilation, and complications were recorded. RESULTS: Successful ring removal was possible in all patients. In 21 cases, the SEPS induced complete erosion, and in 17 cases the ring was removed a month later because of incomplete erosion at the time of SEPS removal. Nine patients (22.0 %) needed endoscopic dilation after stent removal in order to treat fibrotic strictures. Food tolerance was observed in 32 patients (78.0 %) after the procedure. No patient needed surgery and there were no deaths. CONCLUSIONS: Endoscopic removal of the ring using SEPS appeared to be safe and effective after a banded RYGB.


Assuntos
Remoção de Dispositivo/métodos , Endoscopia Gastrointestinal/métodos , Derivação Gástrica/efeitos adversos , Mucosa Gástrica/patologia , Gastroplastia/efeitos adversos , Vômito/cirurgia , Adulto , Endoscopia Gastrointestinal/instrumentação , Feminino , Derivação Gástrica/instrumentação , Gastroplastia/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Necrose , Carne Vermelha/efeitos adversos , Stents , Vômito/etiologia
2.
Rev. colomb. cir ; 24(4): 258-268, dic. 2009. ilus
Artigo em Espanhol | LILACS | ID: lil-540635

RESUMO

El intestino delgado es responsable, no sólo de la digestión y la absorción de los nutrientes, sino también del metabolismo de varios aminoácidos, entre ellos, la glutamina, principal precursor de la citrulina plasmática.El metabolismo único de la citrulina ha atraído interés científico en la aplicación clínica como marcador de la función intestinal en algunas enfermedades y en procedimientos quirúrgicos como el trasplante de intestino delgado y en resecciones intestinales extensas, que desencadenan el síndrome de intestino corto. Se han propuesto diversos marcadores para la valoración de la función intestinal pero, ante la baja sensibilidad y especificidad, además de la difícil aplicación clínica, la citrulina viene mostrándose como una herramienta no invasiva de la valoración de la masa y funcionalidad de los enterocitos. El objetivo de esta revisión es describir la importancia de la citrulina en las principales enfermedades y procedimientos quirúrgicos del intestino delgado, destacando su metabolismo, aplicaciones en el trasplante de intestino y perspectivas de su aplicación clínica en otras enfermedades digestivas.


Assuntos
Humanos , Citrulina , Glutamina , Intestino Delgado , Síndrome , Transplante
3.
Acta cir. bras. ; 17(6)2002.
Artigo em Português | VETINDEX | ID: vti-448386

RESUMO

OBJECTIVE: The use of intra-abdominal electrodes in the study of gastrointestinal electrical wave is an important instrument of the gastrointestinal mioelectric activity. However, the dislocations of the electrodes in non-anaesthetized animals due to diaphragmatic muscle movements, gastrointestinal movements and mainly due to the animals habits, especially in dogs. The study has the objective to demonstrate a procedure that stabilize the system using simple resources an irrelevant cost. METHODS: The authors demonstrate under diagrams and picture a fixed system to fix the electrical electrodes through the animal skin using bottoms. RESULTS: The system was used in 5 animals. Each animal had 3 bipolar electrodes. During the study it was not identified any electrode migration. The animals was kept resting until the complete recovery of the postoperative ileus. CONCLUSION: The procedure proposed is efficient, simple, and easy to be made and allow an acquisition of the mioelectric activity, in dogs not anaesthetized, for long periods.


OBJETIVO: A implantação de eletrodos intra-abdominais para captura de sinais de onda elétrica constitui instrumento de estudo da atividade mioelétrica do tubo gastrointestinal. O deslocamento destes eletrodos do local de implantação ocorre com certa freqüência em animais de experimentação não anestesiados, devido aos movimentos da musculatura diafragmática, abdominal, do peristaltismo gastrintestinal e sobretudo aos hábitos inerentes à espécie de animal estudada, particularmente presentes em caninos. No referido estudo foi proposto um procedimento que proporciona estabilidade ao referido sistema utilizando-se recursos simples e de custos irrelevantes. MÉTODOS: Os autores apresentam através de diagramas e fotos um sistema de ancoração dos eletrodos elétricos na pele dos animais com botões. RESULTADOS: Foram realizados 5 experimentos, fixando-se em cada animal 3 eletrodos bipolares. Os animais foram mantidos em repouso até a completa recuperação do íleo paralítico. Não foi identificado nos animais estudados nenhuma migração dos eletrodos. CONCLUSÃO: O procedimento proposto é eficiente, simples, de fácil confecção e permite o monitoramento da atividade mioelétrica, em cães não anestesiados, por períodos de tempo prolongado.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA