RESUMO
Simple random walk considerations are used to interpret rodent population data collected in Hantavirus-related investigations in Panama regarding the short-tailed cane mouse, Zygodontomys brevicauda. The diffusion constant of mice is evaluated to be of the order of (and larger than) 200 meters squared per day. The investigation also shows that the rodent mean square displacement saturates in time, indicating the existence of a spatial scale which could, in principle, be the home range of the rodents. This home range is concluded to be of the order of 70 meters. Theoretical analysis is provided for interpreting animal movement data in terms of an interplay of the home ranges, the diffusion constant, and the size of the grid used to monitor the movement. The study gives impetus to a substantial modification of existing theory of the spread of the Hantavirus epidemic which has been based on simple diffusive motion of the rodents, and additionally emphasizes the importance for developing more accurate techniques for the measurement of rodent movement.
Assuntos
Arvicolinae/fisiologia , Comportamento Animal , Comportamento de Retorno ao Território Vital , Modelos Biológicos , Animais , Arvicolinae/virologia , Ecologia , Feminino , Infecções por Hantavirus/epidemiologia , Infecções por Hantavirus/transmissão , Infecções por Hantavirus/veterinária , Masculino , Panamá/epidemiologia , Densidade Demográfica , Doenças dos Roedores/epidemiologia , Doenças dos Roedores/transmissão , Doenças dos Roedores/virologiaRESUMO
The incidence of atherosclerosis of the heart transplant in long term survivors is 38% at 5 years. In the present work, myocardial perfusion 201Tl-SPET was assessed as a non-invasive diagnostic method for the detection of postransplant coronary artery disease, as well as its efficiency with regard to other techniques. Twenty patients, aged (47 +/- 9) years old, who underwent heart transplantation at least 3 years earlier, were studied by 201Tl-SPET. Qualitative and quantitative analysis of the images were performed. It was found ischemia in 6 patients, 4 of them asymptomatics. In 5 of the 6 positive cases by SPET coronary stenosis was found by angiography. Kappa coefficient and percent of agreement were k = 0. 76 and Pe = 90%, respectively. There were no relationships among rejection crisis, sepsis by cytomegalovirus and coronary artery disease detected by using 201Tl-SPET (p > 0.05). The most relevant risk factors in the sample were hypertension and hyperlipidemia. Two patients died because of coronary artery disease. It was confirmed by necropsy findings. These results suggest that thallium-201 myocardial perfusion tomography could be useful to detect coronary artery disease in the transplanted heart.