Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Lasers Med Sci ; 30(7): 1873-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25549960

RESUMO

This study aimed to evaluate in vitro performance of near-infrared laser transillumination (NIR-LTI) for detecting early occlusal caries in permanent teeth and compare it with quantitative light-induced fluorescence (QLF), DIAGNOdent Pen (DDPen), and conventional radiography (CR). Ninety-four occlusal surfaces presenting International Caries Detection and Assessment System (ICDAS) scores ranging from 0 to 3 were selected. For the NIR-LTI examination, images were captured using a prototype, which consists of a laser beam (808 nm) and an infrared CCD camera. One occlusal site on each tooth was assessed twice by two examiners. The teeth were prepared histologically and assessed for the presence of early caries. The intraexaminer correlation showed no difference between the NIR-LTI, DDPen, and QLF analytical methods, but all these methods differed from CR. Interexaminer reproducibility was moderate for NIR-LTI, which showed sensitivity (0.68), specificity (0.85), accuracy (0.73), and area under the receiver-operating characteristic (ROC) curve (0.76) similar to those of the fluorescence method and different from those of the CR. In conclusion, the performance of NIR-LTI was comparable to that of DDPen and QLF and may therefore be considered a valid and reliable alternative for the diagnosis of incipient lesions on the occlusal surface of permanent teeth.


Assuntos
Cárie Dentária/diagnóstico , Lasers Semicondutores , Dente Pré-Molar/patologia , Esmalte Dentário/patologia , Diagnóstico Precoce , Humanos , Dente Molar/patologia , Curva ROC , Reprodutibilidade dos Testes , Transiluminação
2.
Phys Rev Lett ; 90(14): 143002, 2003 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-12731913

RESUMO

In this work we measure the time evolution of the population resulting from energy-transfer collisions as a function of the energy difference between the entrance and exit collisional channels using a sample of cold Rydberg atoms produced in a rubidium magneto-optical trap. The 34S(1/2) population, produced by collisions between atoms in the 33P(3/2) state, is monitored as a function of time through the pulsed-field ionization technique. The experimental results are compared with a recent published model based on a two-body interaction considering an attractive potential [Phys. Rev. A 65, 023405 (2002)]]; which is calculated according to a recent Letter by Boisseau et al. [Phys. Rev. Lett. 88, 133004 (2002)]]. The agreement is remarkable, which suggests the existence of such ultralong range potential proposed by Boisseau et al.

SELEÇÃO DE REFERÊNCIAS