Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Abdom Wall Surg ; 3: 13270, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39104598

RESUMO

Aim: Hernia registries report that guidelines are not always implemented by general surgeons and suggest that the success rate of this procedure is higher in hernia specialty centers. There are many definitions of hernia centers, but their objectives consist of improving healthcare by homogenizing the clinical practice. We performed a systematic review and meta-analysis to analyze hernia centers' definitions and compare hernia centers with non-specialized centers. Material and Methods: Cochrane Central, Scopus, Scielo, and PubMed were systematically searched for studies defining a hernia center or comparing hernia centers and non-specialized centers. Outcomes assessed were recurrence, surgical site events, hospital length of stay (LOS), and operative time. We performed subgroup analyses of hernia type. Statistical analysis was performed with R Studio. Results: 3,260 studies were screened and 88 were thoroughly reviewed. Thirteen studies were included. Five studies defined a hernia center and eight studies, comprising 141,366 patients, compared a hernia center with a non-specialized center. Generally, the definitions were similar in decision-making and educational requirements but differed in structural aspects and the steps required for the certification. We found lower recurrence rates for hernia centers for both inguinal (1.08% versus 5.11%; RR 0.21; 95% CI 0.19 to 0.23; p < 0.001) and ventral hernia (3.2% vs. 8.9%; RR 0.425; 95% CI 0.28 to 0.64; p < 0.001). Hernia centers also presented lower surgical site infection for both ventral (4.3% vs. 11.9%; RR 0.435; 95% CI 0.21 to 0.90; p = 0.026) and inguinal (0.1% vs. 0.52%; RR 0.15; 95% CI 0.02 to 0.99; p = 0.49) repair. Conclusion: Our systematic review and meta-analysis support that a hernia center establishment improves postoperative outcomes data. Systematic Review Registration: https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42024522263, PROSPERO CRD42024522263.

2.
Hernia ; 2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-39001938

RESUMO

PURPOSE: Recent guidelines indicate the use of mesh in UHR for defects > 1 cm, as it reduces recurrence, with 10% recurrence rate compared to up to 54.5% with primary closure. However, Nguyen et al. shows that primary closure is still widely performed in UHR, especially for small defects (1-2 cm), for which there is no published data to determine the optimal approach. In addition, previous meta-analysis by Madsen et al. comparing mesh repair with primary closure in UHR didn't exclude emergency conditions and recurrent hernias; also, didn't report subgroup analysis on hernia defect size. Thus, we aimed to perform a systematic review and meta-analysis comparing the mesh repairs vs. primary closure of the defect in an open elective primary UHR. METHODS: We searched for studies comparing mesh with suture in open UHR in PubMed, Scopus, Cochrane, Scielo, and Lilacs from inception until October 2023. Studies with patients ≤ 18 years old, with recurrent or emergency conditions were excluded. Outcomes were recurrence, seroma, hematoma, wound infection, and hospital length of stay. Subgroup analysis was performed for: (1) RCTs only, and (2) hernia defects smaller than 2 cm. We used RevMan 5.4. for statistical analysis. Heterogeneity was assessed with I² statistics, and random effect was used if I² > 25%. RESULTS: 2895 studies were screened and 56 were reviewed. 12 studies, including 4 RCTs, 1 prospective cohort, and 7 retrospective cohorts were included, comprising 2926 patients in total (47.6% in mesh group and 52.4% in the suture group). Mesh repair showed lower rates of recurrence in the overall analysis (RR 0.50; 95% CI 0.31 to 0.79; P = 0.003; I2 = 24%) and for hernia defects smaller than 2 cm (RR 0.56; 95% CI 0.34 to 0.93; P = 0.03; I2 = 0%). Suture repair showed lower rates of seroma (RR 1.88; 95% CI 1.07 to 3.32; P = 0.03; I2 = 0%) and wound infection (RR 1.65; 95%CI 1.12 to 2.43; P = 0.01; I2 = 15%) in the overall analysis, with no differences after performing subgroup analysis of RCTs. No differences were seen regarding hematoma and hospital length of stay. CONCLUSION: The use of mesh during UHR is associated with significantly lower incidence of recurrence in a long-term follow-up compared to the suture repair, reinforcing the previous indications of the guidelines. Additionally, despite the overall analysis showing higher risk of seroma and wound infection for the mesh repair, no differences were seen after subgroup analysis of RCTs. STUDY REGISTRATION: A review protocol for this systematic review and meta-analysis was registered at PROSPERO (CRD42024476854).

3.
Hernia ; 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39085514

RESUMO

PURPOSE: Individual studies indicate poorer outcomes for smokers after hernia repair. Previous meta-analyses have examined the impact of smoking on specific outcomes such as recurrence and surgical site infection, but there has been a lack of comprehensive consensus or systematic review on this subject. Addressing this gap, our study undertakes a systematic review and meta-analysis to assess the impact of smoking on the outcomes of ventral hernia repair (VHR) and inguinal hernia repair. SOURCE: A thorough search of Cochrane Central, Scopus, SciELO, and PubMed/MEDLINE, focusing on studies that examined the effect of smoking on inguinal and VHR outcomes was conducted. Key outcomes evaluated included recurrence, reoperation, surgical site occurrences (SSO), surgical site infection (SSI), and seroma. PRINCIPAL FINDINGS: Out of 3296 screened studies, 42 met the inclusion criteria. These comprised 25 studies (69,295 patients) on VHR and 17 studies (204,337 patients) on inguinal hernia repair. The analysis revealed that smokers had significantly higher rates of recurrence (10.4% vs. 9.1%; RR 1.48; 95% CI [1.15; 1.90]; P < 0.01), SSO (13.6% vs. 12.7%; RR 1.44; 95% CI [1.12; 1.86]; P < 0.01) and SSI (6.6% vs. 4.2%; RR 1.64; 95% CI [1.38; 1.94]; P < 0.01) following VHR. Additionally, smokers undergoing inguinal hernia repair showed higher recurrence (9% vs. 8.7%; RR 1.91; 95% CI [1.21; 3.01]; P < 0.01), SSI (0.6% vs. 0.3%; RR 1.6; 95% CI [1.21; 2.0]; P < 0.001), and chronic pain (9.9% vs. 10%; RR 1.24; 95% CI [1.06; 1.45]; P < 0.01) rates. No significant differences were observed in seroma (RR 2.63; 95% CI [0.88; 7.91]; P = 0.084) and reoperation rates (RR 1.48; 95% CI [0.77; 2.85]; P = 0.236) for VHR, and in reoperation rates (RR 0.99; 95% CI [0.51; 1.91]; P = 0.978) for inguinal hernias between smokers and non-smokers. Analysis using funnel plots and Egger's test showed the absence of publication bias in the study outcomes. CONCLUSION: This comprehensive meta-analysis found statistically significant increases in recurrence rates, and immediate postoperative complications, such as SSO and SSI following inguinal and VHR. Also, our subgroup analysis suggests that the MIS approach seems to be protective of adverse outcomes in the smokers group. However, our findings suggest that these findings are not of clinical relevance, so our data do not support the necessity of smoking cessation before hernia surgery. More studies are needed to elucidate the specific consequences of smoking in both inguinal and ventral hernia repair. PROSPERO REGISTRATION: ID CRD42024517640.

4.
Hernia ; 28(4): 1053-1061, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38888838

RESUMO

PURPOSE: The transinguinal preperitoneal (TIPP) technique is an open approach to groin hernia repair with posteriorly positioned mesh supposed to reduce recurrence rates. However, transabdominal preperitoneal (TAPP) and totally extraperitoneal (TEP) techniques have similar mesh positioning with the advantages of minimally invasive surgery (MIS). Hence, we performed a systematic review and meta-analysis comparing TIPP and MIS for groin hernia repair. SOURCE: Cochrane, Embase, Scopus, Scielo, and PubMed were systematically searched for studies comparing TIPP and MIS techniques for groin hernia repair. Outcomes assessed were recurrence, chronic pain, surgical site infection (SSI), seroma, and hematoma. We performed a subgroup analysis of TAPP and TEP techniques separately. Statistical analysis was performed with R Studio. PRINCIPAL FINDINGS: 81 studies were screened and 19 were thoroughly reviewed. Six studies were included, of which two compared TIPP with TEP technique, two compared TIPP with TAPP, and two compared TIPP with both TEP and TAPP techniques. We found lower recurrence rates for the TEP technique compared to TIPP (0.38% versus 1.19%; RR 2.68; 95% CI 1.01 to 7.11; P = 0.04). Also, we found lower seroma rates for TIPP group on the overall analysis (RR 0.21; P = 0.002). We did not find statistically significant differences regarding overall recurrence (RR 1.6; P = 0.19), chronic pain (RR 1.53; P = 0.2), SSI (RR 2.51; P = 0.47), and hematoma (RR 1.29; P = 0.76) between MIS and TIPP. No statistically significant differences were found in the subgroup analysis of TAPP technique for all the outcomes. CONCLUSION: Our systematic review and meta-analysis found no differences between TIPP and MIS approaches in the overall analysis of recurrence, SSI, and chronic pain rates. Further research is needed to analyze individual techniques and draw a more precise conclusion on this subject. PROSPERO REGISTRATION: ID CRD42024530107, April 8, 2024.


Assuntos
Hérnia Inguinal , Herniorrafia , Procedimentos Cirúrgicos Minimamente Invasivos , Telas Cirúrgicas , Humanos , Hérnia Inguinal/cirurgia , Herniorrafia/métodos , Herniorrafia/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Recidiva , Seroma/etiologia , Infecção da Ferida Cirúrgica/etiologia , Dor Crônica/etiologia , Hematoma/etiologia
5.
Surg Endosc ; 37(11): 8421-8428, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37730850

RESUMO

INTRODUCTION: Inguinoscrotal hernias (ISH) pose a challenge to surgeons with consistently higher rates of postoperative complications and recurrence rates. The aim of this study is to report our initial experience and early results with a new technique for inguinoscrotal hernia repair. METHODS: A review of a prospectively maintained multi-center database was conducted in patients who underwent minimally invasive repair using the "primary abandon-of-the-sac" (PAS) technique for inguinoscrotal hernias from March 2021 to July 2022. Demographics and outcomes were analyzed. Univariate analysis and multivariate logistic regression were performed. RESULTS: A total of 76 minimally invasive inguinal hernia repairs were performed. In 70 patients (92%) C-PAS was used as the technique to abandon the sac while in the remaining 6 patients, "pirate-eye-patch" technique was used. Median hernia ring was 3 (IQR 2.5-3.5) cm and median hernia sac was 9.5 (8-10.8) cm. Median operative time was 70 min (IQR 56-96). Seroma was present in 22 (28.9%) patients 7 days after surgery. Most had seroma only in the inguinal area (n = 19; 25%). Thirty days after surgery, 12 (15.8%) patients still had seroma in the inguinal area and 6 (7.9%) in the inguinoscrotal area. Ninety days after surgery, four (5.3%) patients had inguinal seroma, 2 (2.6%) scrotal seromas and 3 (3.9%) inguinoscrotal seromas. The size of the hernia sac was not associated with seroma formation 7 days after surgery (OR 1.06; 95% CI 0.89-1.2; P = 0.461) in the multivariate logistic regression. BMI was also not associated with seroma formation (OR 0.8; 95% CI 0.74-1.06; P = 0.2). CONCLUSIONS: Planned abandon of the hernia sac is an interesting alternative and is associated with a low rate of complications and acceptable seroma formation rates.


Assuntos
Hérnia Inguinal , Laparoscopia , Masculino , Humanos , Seroma/epidemiologia , Seroma/etiologia , Laparoscopia/métodos , Telas Cirúrgicas/efeitos adversos , Hérnia Inguinal/cirurgia , Hérnia Inguinal/complicações , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Herniorrafia/métodos
6.
Arq Gastroenterol ; 59(2): 226-230, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35830033

RESUMO

BACKGROUND: Poly-4-hydroxybutyrate (P4HB) is a naturally occurring polymer derived from transgenic E. coli bacteria with the longest degradation rate when compared to other available products. This polymer has been manufactured as a biosynthetic mesh to be used as reinforcement when repairing a variety of abdominal wall defects. OBJECTIVE: We aim to describe our center initial experience with this mesh and discuss the possible indications that may benefit from the use of P4HB mesh. METHODS: This is a descriptive retrospective study of patients who underwent abdominal wall repair with a P4HB mesh from October 2018 to December 2020 in a single, large volume, academic center. RESULTS: A total of 51 patients (mean age 54.4 years, range 12-89) underwent abdominal wall reconstruction with a P4HB mesh between October 2018 and December 2020. The mean BMI was 30.5 (range 17.2-50.6). Twenty-three (45%) patients had a prior hernia repair at the site. We grouped patients into six different indications for the use of P4HB mesh in our cohort: clean-contaminated, contaminated or infected field (57%), patient refusal for permanent meshes (14%), those with high risk for post-operative infection (12%), visceral protection of second mesh (10%), recurrence with related chronic pain from mesh (6%), and children (2%). Median follow-up was 105 days (range 8-648). Two patients had hernia recurrence (4%) and 8 (16%) patients developed seroma. CONCLUSION: P4HB mesh is a safe and a viable alternative for complex hernias and high-risk patients with a low complication rate in the short-term.


Assuntos
Parede Abdominal , Hérnia Ventral , Parede Abdominal/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Escherichia coli , Hérnia Ventral/cirurgia , Humanos , Hidroxibutiratos , Pessoa de Meia-Idade , Polímeros , Recidiva , Estudos Retrospectivos , Telas Cirúrgicas , Resultado do Tratamento , Adulto Jovem
7.
Arq. gastroenterol ; Arq. gastroenterol;59(2): 226-230, Apr.-June 2022. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1383857

RESUMO

ABSTRACT Background Poly-4-hydroxybutyrate (P4HB) is a naturally occurring polymer derived from transgenic E. coli bacteria with the longest degradation rate when compared to other available products. This polymer has been manufactured as a biosynthetic mesh to be used as reinforcement when repairing a variety of abdominal wall defects. Objective: We aim to describe our center initial experience with this mesh and discuss the possible indications that may benefit from the use of P4HB mesh. Methods: This is a descriptive retrospective study of patients who underwent abdominal wall repair with a P4HB mesh from October 2018 to December 2020 in a single, large volume, academic center. Results: A total of 51 patients (mean age 54.4 years, range 12-89) underwent abdominal wall reconstruction with a P4HB mesh between October 2018 and December 2020. The mean BMI was 30.5 (range 17.2-50.6). Twenty-three (45%) patients had a prior hernia repair at the site. We grouped patients into six different indications for the use of P4HB mesh in our cohort: clean-contaminated, contaminated or infected field (57%), patient refusal for permanent meshes (14%), those with high risk for post-operative infection (12%), visceral protection of second mesh (10%), recurrence with related chronic pain from mesh (6%), and children (2%). Median follow-up was 105 days (range 8-648). Two patients had hernia recurrence (4%) and 8 (16%) patients developed seroma. Conclusion: P4HB mesh is a safe and a viable alternative for complex hernias and high-risk patients with a low complication rate in the short-term.


RESUMO Contexto: 4-Polihidroxibutirato (P4HB) é um polímero natural derivado da E. coli transgênica que tem a mais longa taxa de degradação quando comparado a outros produtos. Este polímero é manufaturado como uma tela biossintética a ser usada como um reforço no reparo de uma variedade de defeitos de parede abdominal. Objetivo: O objetivo deste estudo é descrever nossa experiência inicial com esta tela e discutir suas possíveis indicações. Métodos: Estudo retrospectivo e descritivo com pacientes que foram submetidos a cirurgia de reconstrução de parede abdominal de outubro de 2018 a dezembro de 2020 em um grande centro acadêmico. Resultados: Cinquenta e um pacientes, média de 54,4 anos (12-89) foram submetidos a reconstrução da parede abdominal com tela de P4HB entre outubro de 2018 e dezembro de 2020. O índice de massa corpórea médio foi de 30,5 kg/m2(17,2-50,6). Vinte e três pacientes (45%) tinham cirurgia prévia de hérnia no mesmo local. Nós agrupamos pacientes em seis diferentes indicações para o uso da tela de P4HB: campo limpo-contaminado, contaminado, infectado (57%), recusa do paciente em telas permanentes (14%), pacientes com alto risco de infecção no pós-operatório (12%), proteção visceral de contato com outra tela (10%), recidiva da hérnia associada com dor crônica relacionada a tela anterior (6%) e pacientes pediátricos (2%). O seguimento mediano foi de 105 dias (8-648). Dois pacientes tiveram recidiva (4%) e 8 (16%) desenvolveram seroma. Conclusão: O uso da tela de P4HB se mostrou uma alternativa segura e viável com baixa taxa de complicações para estes pacientes no curto prazo.

8.
Rev Col Bras Cir ; 49: e20223172, 2022.
Artigo em Inglês, Português | MEDLINE | ID: mdl-35588534

RESUMO

Abdominal wall (AW) hernias are a common problem faced by general surgeons. With an essentially clinical diagnosis, abdominal hernias have been considered a simple problem to be repaired. However, long-term follow-up of patients has shown disappointing results, both in terms of complications and recurrence. In this context, preoperative planning with control of comorbidities and full knowledge of the hernia and its anatomical relationships with the AW has gained increasing attention. Computed tomography (CT) appears to be the best option to determine the precise size and location of abdominal hernias, presence of rectus diastase and/or associated muscle atrophy, as well as the proportion of the hernia in relation to the AW itself. This information might help the surgeon to choose the best surgical technique (open vs MIS), positioning and fixation of the meshes, and eventual need for application of botulinum toxin, preoperative pneumoperitoneum or component separation techniques. Despite the relevance of the findings, they are rarely described in CT scans as radiologists are not used to report findings of the AW as well as to know what information is really needed. For these reasons, we gathered a group of surgeons and radiologists to establish which information about the AW is important in a CT. Finally, a structured report is proposed to facilitate the description of the findings and their interpretation.


Assuntos
Parede Abdominal , Hérnia Ventral , Cirurgiões , Parede Abdominal/diagnóstico por imagem , Parede Abdominal/cirurgia , Hérnia Ventral/diagnóstico por imagem , Hérnia Ventral/cirurgia , Herniorrafia/métodos , Humanos , Recidiva , Telas Cirúrgicas , Tomografia Computadorizada por Raios X/métodos
9.
Rev Col Bras Cir ; 49: e20213152, 2022.
Artigo em Inglês, Português | MEDLINE | ID: mdl-35239848

RESUMO

INTRODUCTION: the botulinum toxin A (BTA) has been used to achieve a chemical component separation, and it has been used with favorable outcomes for the repair of complex ventral hernia (CVH) with and without loss of domain (LD). The aim of this study is to describe our early experience with the chemical component separation in the United Sates. METHODS: a retrospective observational study of all patients who underwent ventral hernia repair for CVH with or without LD between July 2018 and June 2020. Preoperative BTA was injected in all patients via sonographic guidance bilaterally, between the lateral muscles to achieve chemical denervation before the operation. Patient demographics, anatomical location of the hernia, perioperative data and postoperative data are described. RESULTS: 36 patients underwent this technique before their hernia repair between July 2018 to June 2020. Median age was 62 years (range 30-87). Median preoperative defect size was 12cm (range 6-25) and median intraoperative defect size was 13cm (range 5-27). Median preoperative hernia sac volume (HSV) was 1338cc (128-14040), median preoperative abdominal cavity volume (ACV) was 8784cc (5197-18289) and median volume ration (HSV/ACV) was 14%. The median OR time for BTA administration was 45 minutes (range 28-495). Seroma was the most common postoperative complication in 8 of the patients (22%). Median follow up was 43 days (range 0-580). CONCLUSION: preoperative chemical component separation with BTA is a safe and effective adjunct to hernia repair in CVH repairs where a challenging midline fascial approximation is anticipated.


Assuntos
Parede Abdominal , Toxinas Botulínicas Tipo A , Fármacos Neuromusculares , Músculos Abdominais/cirurgia , Parede Abdominal/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Toxinas Botulínicas Tipo A/uso terapêutico , Hérnia Ventral/cirurgia , Herniorrafia , Humanos , Pessoa de Meia-Idade , Fármacos Neuromusculares/uso terapêutico , New York , Cuidados Pré-Operatórios
10.
J Laparoendosc Adv Surg Tech A ; 32(2): 183-188, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33685253

RESUMO

Background: The Lichtenstein repair has long been heralded as the gold standard for unilateral primary inguinal hernias. However, minimally invasive surgery (MIS) repairs have gained popularity over the past decades given its advantages in recurrent, bilateral, and now even in primary inguinal hernias. We aim to further explore the perception of different techniques among surgeons internationally. Methods: A questionnaire was posted in three closed groups for surgeons and residents on Facebook® and surgical groups on WhatsApp®. It was also e-mailed to members of the following surgical societies: Mexican Society of Surgery, Brazilian Hernia Society, Asia Pacific Hernia Society, and European Hernia Society. Descriptive and basic comparative statistical analyses were performed. Results: In total, 874 surgeons answered the survey: 759 (86.9%) were male and 418 (47.8%) were from North America, 735 (84.1%) had completed training and 605 (69.2%) considered themselves hernia specialists. If safety profiles of inguinal herniorrhaphy were equal, 533 (61%) would choose MIS. Laparoscopic transabdominal preperitoneal ranked first among preferred techniques if the cost of all techniques was the same. Safety of the procedure followed by experience of the surgeon is the most influential factors. Lastly, hernia specialists were more likely to choose an MIS technique (P < .0001). Conclusion: When an international sample of 874 attending and trainee surgeons were surveyed about what technique they would prefer to repair their own uncomplicated unilateral inguinal hernia, most chose MIS. Safety of the procedure and the surgeon's experience were the most important factors in choosing a surgical technique.


Assuntos
Hérnia Inguinal , Laparoscopia , Cirurgiões , Hérnia Inguinal/cirurgia , Herniorrafia , Humanos , Masculino , Telas Cirúrgicas , Inquéritos e Questionários
11.
Rev. Col. Bras. Cir ; 49: e20213152, 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1365380

RESUMO

ABSTRACT Introduction: the botulinum toxin A (BTA) has been used to achieve a chemical component separation, and it has been used with favorable outcomes for the repair of complex ventral hernia (CVH) with and without loss of domain (LD). The aim of this study is to describe our early experience with the chemical component separation in the United Sates. Methods: a retrospective observational study of all patients who underwent ventral hernia repair for CVH with or without LD between July 2018 and June 2020. Preoperative BTA was injected in all patients via sonographic guidance bilaterally, between the lateral muscles to achieve chemical denervation before the operation. Patient demographics, anatomical location of the hernia, perioperative data and postoperative data are described. Results: 36 patients underwent this technique before their hernia repair between July 2018 to June 2020. Median age was 62 years (range 30-87). Median preoperative defect size was 12cm (range 6-25) and median intraoperative defect size was 13cm (range 5-27). Median preoperative hernia sac volume (HSV) was 1338cc (128-14040), median preoperative abdominal cavity volume (ACV) was 8784cc (5197-18289) and median volume ration (HSV/ACV) was 14%. The median OR time for BTA administration was 45 minutes (range 28-495). Seroma was the most common postoperative complication in 8 of the patients (22%). Median follow up was 43 days (range 0-580). Conclusion: preoperative chemical component separation with BTA is a safe and effective adjunct to hernia repair in CVH repairs where a challenging midline fascial approximation is anticipated.


RESUMO Introdução: a toxina botulínica A (TBA) tem sido usada para alcançar a separação química dos componentes, com resultados favoráveis para o reparo de hérnias ventrais complexas (HVC) com ou sem perda de domínio (PD). O objetivo deste estudo é descrever nossa experiência inicial com a separação química dos componentes nos Estados Unidos. Métodos: estudo retrospectivo observacional com todos os pacientes submetidos a reparo de hérnia ventral complexa com ou sem PD entre julho de 2018 e junho de 2020. A TBA pré-operatória foi injetada em todos os pacientes, guiada por ultrassonografia, bilateralmente entre os músculos laterais para alcançar a denervação química antes da operação. Dados demográficos dos pacientes, local da hérnia, dados peri-operatórios e pós-operatórios são descritos. Resultados: 36 pacientes foram submetidos a esta técnica antes do reparo da hérnia. A idade mediana foi 62 anos (30-87). O tamanho mediano pré-operatório do defeito herniário foi 12cm (6-25) e o defeito mediano intra-operatorio foi 13cm (5-27). O volume mediano do saco herniário pré-operatório foi 1.338mL (128-14.040), o volume mediano da cavidade abdominal pré-operatório foi 8.784 (5.197-18.289) mL e a razão dos volumes foi 14%. A duração mediana da operação para aplicação da TBA foi 45 minutos (28-495). O seroma foi a complicação mais comum no pós-operatório, em oito pacientes (22%). O seguimento pós-operatório mediano foi de 43 dias (0-580). Conclusão: a separação pré-operatória de componentes com TBA é tratamento adjuvante seguro e eficaz em reparos de HVC em que aproximação da fáscia é antecipadamente desafiadora.


Assuntos
Humanos , Adulto , Idoso , Idoso de 80 Anos ou mais , Toxinas Botulínicas Tipo A/uso terapêutico , Parede Abdominal/cirurgia , Fármacos Neuromusculares/uso terapêutico , Cuidados Pré-Operatórios , New York , Músculos Abdominais/cirurgia , Herniorrafia , Hérnia Ventral/cirurgia , Pessoa de Meia-Idade
12.
Rev. Col. Bras. Cir ; 49: e20223172, 2022. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1376238

RESUMO

ABSTRACT Abdominal wall (AW) hernias are a common problem faced by general surgeons. With an essentially clinical diagnosis, abdominal hernias have been considered a simple problem to be repaired. However, long-term follow-up of patients has shown disappointing results, both in terms of complications and recurrence. In this context, preoperative planning with control of comorbidities and full knowledge of the hernia and its anatomical relationships with the AW has gained increasing attention. Computed tomography (CT) appears to be the best option to determine the precise size and location of abdominal hernias, presence of rectus diastase and/or associated muscle atrophy, as well as the proportion of the hernia in relation to the AW itself. This information might help the surgeon to choose the best surgical technique (open vs MIS), positioning and fixation of the meshes, and eventual need for application of botulinum toxin, preoperative pneumoperitoneum or component separation techniques. Despite the relevance of the findings, they are rarely described in CT scans as radiologists are not used to report findings of the AW as well as to know what information is really needed. For these reasons, we gathered a group of surgeons and radiologists to establish which information about the AW is important in a CT. Finally, a structured report is proposed to facilitate the description of the findings and their interpretation.


RESUMO Hérnias da parede abdominal são um problema bastante comum enfrentado pelo cirurgiões gerais. De diagnóstico essencialmente clínico, as hérnias abdominais durante muito tempo têm sido consideradas um problema de simples reparo. Entretanto, o acompanhamento de longo prazo dos pacientes têm demonstrado resultados desapontadores, tanto em termos de complicações quanto risco de recidiva da hérnia. Neste contexto, o planejamento pré-operatório com controle de comorbidades e pleno conhecimento da hérnia e suas relações anatômicas com a parede abdominal têm ganho cada vez mais atenção. A tomografia de abdome parece ser a melhor opção para determinar o tamanho e localização precisos das hérnias abdominais, presença de diastase de músculo reto e/ou atrofia da parede associada, assim como proporção da hérnia em relação a parede abdominal. Essas informações podem auxiliar o cirurgião na escolha da melhor técnica cirúrgica (aberta vs. MIS), posicionamento e fixação das telas, e eventual necessidade de aplicação de toxina botulínica, pneumoperitônio pré-operatório ou técnicas de separação de componentes. Apesar da relevância dos achados, eles são raramente descritos em exames de tomografia uma vez que os radiologistas não estão acostumados a olhar para a parede abdominal assim como não sabem quais as informações são realmente necessárias. Por estes motivos, nós reunimos um grupo de cirurgiões e radiologistas visando estabelecer quais são as informações da parede abdominal mais importantes em um exame de tomografia assim como propor um laudo estruturado para facilitar a descrição dos achados e sua interpretação.

13.
Arq Bras Cir Dig ; 34(2): e1599, 2021.
Artigo em Inglês, Português | MEDLINE | ID: mdl-34669888

RESUMO

BACKGROUND: Lateral incisional hernias arise between the linea alba and the posterior paraspinal muscles. Anatomical boundaries contain various topographic variations, such as multiple nearby bony structures and paucity of aponeurotic tissue that make it particularly challenging to repair. AIM: To describe a robotic assisted surgical technique for incisional lumbar hernia repair. METHODS: Retrospective data was collected from four patients who underwent robotic-assisted repair of their lumbar hernias after open nephrectomies. RESULTS: Age ranged from 41-53 y. Two patients had right sided flank hernias while the other two on the left. One patient had a recurrent hernia on the left side. The patients were placed in lateral decubitus position contralateral to the hernia defect side. A trans-abdominal preperitoneal approach was used in all cases. Each case was accomplished with two 8 mm robotic ports, a 12 mm periumbilical port, and a 5 mm assistance port that allowed docking on the ipsilateral hernia side. The hernias were identified, a preperitoneal plane was created, and the hernia sac completely dissected allowing for complete visualization of the defect. All defects were primarily closed. Polypropylene or ProGripTM mesh was applied with at least 5 cm overlap and secured using either #0 Vicryl® transfacial sutures, Evicel® or a combination of both. The peritoneal space was closed with running suture and the ports were removed and closed. The average surgical length was 4 hr. The post-operative length of stay ranged from 0-2 days. CONCLUSION: The robotics platform may provide unique advantages in the repair of lateral incisional hernias and represents a safe, feasible and effective minimally invasive approach for the correction of lateral incisional hernias.


Assuntos
Hérnia Ventral , Hérnia Incisional , Laparoscopia , Hérnia Ventral/cirurgia , Herniorrafia , Humanos , Hérnia Incisional/cirurgia , Estudos Retrospectivos , Telas Cirúrgicas
14.
Arq Bras Cir Dig ; 34(2): e1597, 2021.
Artigo em Inglês, Português | MEDLINE | ID: mdl-34669887

RESUMO

BACKGROUND: Since publication of our paper "Ten Golden Rules for a Safe MIS Inguinal Hernia Repair" we have received many questions. As the authors, we feel it is important to address these topics as a follow-up to our paper. AIM: To discuss in more details the main points of controversy, review the rules and update de recommendations. METHOD: The questions and discussions came mainly over five rules, numbered 3, 5, 6, 7, 10. We analyzed all the comments about recommendations and update some technical principles. RESULTS: Rule 3 - Removing normal fat plugs from the obturator canal is unnecessary and therefore is not recommended; Rule 5 - transection of the uterine round ligament (1 cm proximal to the deep ring) facilitates adequate dissection. When performed in this way it does not appear to be associated with complications; Rule 6 - transection of huge sacs are safer than over-dissection of the cord structures. Whether dissecting completely the sac or abandon the distal part it results in less postoperative seromas is an ongoing debate; Rule 7 - any retroperitoneal structure traversing the internal ring is or play a role like a hernia. Failing to identify and remove the lipoma will ultimately result in the patient experiencing a recurrence; Rule 10 - in TAPP peritoneum should preferably be closed with suture than tackes. CONCLUSION: 10 Golden Rules emphasize the most important surgical tips and technical steps that allow the safe performance of MIS repairs of inguinal hernias, regardless the technique.


Assuntos
Hérnia Inguinal , Laparoscopia , Dissecação , Feminino , Hérnia Inguinal/cirurgia , Herniorrafia , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Peritônio , Recidiva , Resultado do Tratamento
16.
ABCD (São Paulo, Impr.) ; 34(2): e1597, 2021. graf
Artigo em Inglês, Português | LILACS | ID: biblio-1345009

RESUMO

ABSTRACT Background: Since publication of our paper "Ten Golden Rules for a Safe MIS Inguinal Hernia Repair" we have received many questions. As the authors, we feel it is important to address these topics as a follow-up to our paper. Aim: To discuss in more details the main points of controversy, review the rules and update de recommendations. Method: The questions and discussions came mainly over five rules, numbered 3, 5, 6, 7, 10. We analyzed all the comments about recommendations and update some technical principles. Results: Rule 3 - Removing normal fat plugs from the obturator canal is unnecessary and therefore is not recommended; Rule 5 - transection of the uterine round ligament (1 cm proximal to the deep ring) facilitates adequate dissection. When performed in this way it does not appear to be associated with complications; Rule 6 - transection of huge sacs are safer than over-dissection of the cord structures. Whether dissecting completely the sac or abandon the distal part it results in less postoperative seromas is an ongoing debate; Rule 7 - any retroperitoneal structure traversing the internal ring is or play a role like a hernia. Failing to identify and remove the lipoma will ultimately result in the patient experiencing a recurrence; Rule 10 - in TAPP peritoneum should preferably be closed with suture than tackes. Conclusion: 10 Golden Rules emphasize the most important surgical tips and technical steps that allow the safe performance of MIS repairs of inguinal hernias, regardless the technique.


RESUMO Racional: Desde a publicação de nosso artigo "Dez Regras de Ouro para o Reparo Seguro de Hérnia Inguinal MIS", recebemos muitos questionamentos. Como autores, sentimos que é importante abordar esses tópicos como seguimento do artigo Objetivo: Discutir com mais detalhes os principais pontos de controvérsia, revisar as regras e atualizar as recomendações. Método: As dúvidas e discussões surgiram principalmente sobre cinco regras, numeradas 3, 5, 6, 7, 10. Analisamos todos os comentários sobre as recomendações e atualizamos alguns dos princípios técnicos. Resultados: Regra 3 - remoção dos plugs de gordura normais do canal obturador é desnecessária e, portanto, não é recomendada; Regra 5 - transecção do ligamento redondo do útero (1 cm proximal ao anel profundo) facilita a dissecção adequada e quando realizado dessa forma, não parece estar associada com complicações; Regra 6 - transecção de grandes sacos herniários é mais segura do que a dissecção excessiva das estruturas do cordão espermático e, se dissecar completamente o saco ou abandonar a parte distal, resulta em menos seromas pós-operatórios ainda é motivo de debate; Regra 7 - qualquer estrutura retroperitoneal que atravessa o anel interno é ou desempenha o papel como uma hérnia e deixar de identificar e remover o lipoma acabará resultando em recorrência; Regra 10 - na TAPP o peritônio deve ser fechado preferencialmente com sutura do que com tacks. Conclusão: As 10 Regras de Ouro enfatizam as dicas cirúrgicas e etapas técnicas mais importantes que permitem a realização segura de reparos MIS de hérnias inguinais, independentemente da técnica.


Assuntos
Humanos , Feminino , Laparoscopia , Hérnia Inguinal/cirurgia , Peritônio , Recidiva , Resultado do Tratamento , Procedimentos Cirúrgicos Minimamente Invasivos , Dissecação , Herniorrafia
17.
ABCD (São Paulo, Impr.) ; 34(2): e1599, 2021. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1345012

RESUMO

ABSTRACT Background: Lateral incisional hernias arise between the linea alba and the posterior paraspinal muscles. Anatomical boundaries contain various topographic variations, such as multiple nearby bony structures and paucity of aponeurotic tissue that make it particularly challenging to repair. Aim: To describe a robotic assisted surgical technique for incisional lumbar hernia repair. Methods: Retrospective data was collected from four patients who underwent robotic-assisted repair of their lumbar hernias after open nephrectomies. Results: Age ranged from 41-53 y. Two patients had right sided flank hernias while the other two on the left. One patient had a recurrent hernia on the left side. The patients were placed in lateral decubitus position contralateral to the hernia defect side. A trans-abdominal preperitoneal approach was used in all cases. Each case was accomplished with two 8 mm robotic ports, a 12 mm periumbilical port, and a 5 mm assistance port that allowed docking on the ipsilateral hernia side. The hernias were identified, a preperitoneal plane was created, and the hernia sac completely dissected allowing for complete visualization of the defect. All defects were primarily closed. Polypropylene or ProGripTM mesh was applied with at least 5 cm overlap and secured using either #0 Vicryl® transfacial sutures, Evicel® or a combination of both. The peritoneal space was closed with running suture and the ports were removed and closed. The average surgical length was 4 hr. The post-operative length of stay ranged from 0-2 days. Conclusion: The robotics platform may provide unique advantages in the repair of lateral incisional hernias and represents a safe, feasible and effective minimally invasive approach for the correction of lateral incisional hernias.


RESUMO Racional: As hérnias incisionais laterais surgem entre a linha alba e os músculos paravertebrais posteriores. Os limites anatômicos contêm várias variações topográficas, como várias estruturas ósseas próximas e escassez de tecido aponeurótico que tornam o reparo particularmente difícil . Objetivo: Descrever uma técnica assistida por robótica para o reparo de hérnia lombar incisional. Métodos: Dados foram coletados retrospectivamente de quatro pacientes que foram submetidos ao reparo de hérnia lombar após nefrectomias abertas por técnica robótica. Os pacientes tinham entre 41-53 anos de idade. Dois possuíam hérnia no flanco direito e os outros dois no flanco esquerdo. Resultados: Os pacientes foram colocados em posição de decúbito lateral contralateral ao lado do defeito. Abordagem pré-peritoneal transabdominal foi realizada em todos os casos. Cada procedimento foi realizado com dois trocárteres robóticos de 8 mm, um periumbilical de 12 mm e um auxiliar de 5 mm, permitindo docking ipsilateral ao lado da hérnia. As hérnias foram identificadas, plano pré-peritoneal foi criado e o saco herniário completamente dissecado, permitindo completa visualização do defeito. Todos os defeitos foram fechados primariamente com fio de sutura 0/1V-Loc. Tela de polipropileno ou ProGripTM foi usada com pelo menos 5 cm de overlap e fixada com sutura transfacial com Vicryl® 0, Evicel® ou combinação dos dois. O espaço pré-peritoneal foi fechado com sutura contínua e os trocárteres removidos. O tempo operatório médio foi de 4 h. O tempo de permanência hospitalar variou entre 0-2 dias. Conclusão: A plataforma robótica é capaz de providenciar vantagens únicas no reparo de hérnias incisionais laterais e representa abordagem minimamente invasiva segura, factível e eficaz para o reparo das hérnias laterais incisionais.


Assuntos
Humanos , Laparoscopia , Hérnia Incisional/cirurgia , Hérnia Ventral/cirurgia , Telas Cirúrgicas , Estudos Retrospectivos , Herniorrafia
18.
Arq Bras Cir Dig ; 33(2): e1519, 2020.
Artigo em Inglês, Português | MEDLINE | ID: mdl-33237163

RESUMO

BACKGROUND: Laparoscopic best approach of repairing inguinoscrotal hernias are still debatable. Incorrect handling of the distal sac can possibly result in damage to cord structures and negative postoperative outcomes as ischemic orquitis or inguinal neuralgia. AIM: To describe a new technique for a minimally invasive approach to inguinoscrotal hernias and to analyze the preliminary results of patients undergoing the procedure. METHODS: A review of a prospectively maintained database was conducted in patients who underwent minimally invasive repair using the "primary abandon-of-the-sac" (PAS) technique for inguinoscrotal hernias. Patient´s demographics, as well as intraoperative variables and postoperative outcomes were also analyzed. RESULTS: Twenty-six male were submitted to this modified procedure. Mean age of the case series was 53.8 years (range 34-77) and body mass index was 26.8 kg/m2 (range 20.8-34.2). There were no intraoperative complications or conversion. Average length of stay was one day. No surgical site infections, pseudo hydrocele or neuralgia were reported after the procedure and two patients presented seroma. No inguinal hernia recurrence was verified during the mean 21.4 months of follow up. CONCLUSION: The described technique is safe, feasible and reproducible, with good postoperative results.


Assuntos
Hérnia Inguinal , Herniorrafia/métodos , Laparoscopia/métodos , Adulto , Idoso , Virilha/cirurgia , Hérnia Inguinal/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Telas Cirúrgicas , Infecção da Ferida Cirúrgica , Resultado do Tratamento
19.
Surg Laparosc Endosc Percutan Tech ; 30(6): 495-499, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32675755

RESUMO

BACKGROUND: As the minimally invasive surgery revolution approaches 30 years, many techniques are now available for cholecystectomy: open, conventional laparoscopy, ini-laparoscopy, single incision, robotic, and natural orifice. Although much has been published about patient preferences regarding these techniques, less is known about surgeon perceptions and preferences. The aim of this study was to survey attending and trainee surgeons about which cholecystectomy technique they would prefer for themselves and what factors determine their decision. METHODS: Attending fellow and resident surgeons globally completed a Google Forms online questionnaire that was posted in 3 closed groups for surgeons on Facebook and WhatsApp. RESULTS: The online questionnaire was completed by 600 surgeons (453 attending surgeons and 147 residents/fellows). Most respondents were male individuals (87.6% of attending surgeons, 78.2% of trainee surgeons). The most common age range of respondents was 31 to 40 years. Surgeon response was global, with especially good representation from North American, Asian, and European physicians. When conventional laparoscopy, mini-laparoscopy, and robotic surgery were the options offered for cholecystectomy, 58.5% of trainees and 45.7% of surgeons chose conventional laparoscopy. When asked if they would consider a single-incision or natural orifice transluminal endoscopic surgery approach, 91.5% answered no. When asked which technique they would prefer if hypothetically all techniques were equally safe, about three-fourths chose either conventional laparoscopy (46%) or mini-laparoscopy (27%). When asked to rank which factors they considered most important in choosing a surgical technique, surgeon experience (52%) and safety of the procedure (45%) were the 2 most important factors. CONCLUSIONS: When an international sample of 600 attending and trainee surgeons were asked about undergoing a cholecystectomy on themselves, most chose either conventional laparoscopy or mini-laparoscopy as their preferred access technique. Single-incision and natural orifice transluminal endoscopic surgery approaches were unpopular. Surgeons ranked the experience of the operating surgeon and safety of the procedure as the most important factors guiding their decision.


Assuntos
Laparoscopia , Cirurgia Endoscópica por Orifício Natural , Procedimentos Cirúrgicos Robóticos , Cirurgiões , Adulto , Colecistectomia , Humanos , Masculino
20.
Surg Endosc ; 34(4): 1458-1464, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32076858

RESUMO

BACKGROUND: Although laparoscopic inguinal hernia repair was described about 30 years ago and advantages of the technique have been demonstrated, the utilization of this approach has not been what we would expect. Some reasons may be the need for surgeons to understand the posterior anatomy of the groin from a new vantage point, as well as to acquire advanced laparoscopic skills. Recently, however, the introduction of a robotic approach has dramatically increased the adoption of minimally invasive techniques for inguinal hernia repair. METHODS: Important recent contributions to this evolution have been the establishment of a new concept known as the critical view of the Myopectineal Orifice (MPO) and the description of a new way of understanding the posterior view of the antomy of the groin (inverted Y and the five triangles). In this paper, we describe 10 rules for a safe MIS inguinal hernia repair (TAPP, TEP, ETEP, RTAPP) that combines these two new concepts in a unique way. CONCLUSIONS: As the critical view of safety has made laparoscopic cholecystectomy safer, we feel that following our ten rules based on understanding the anatomy of the posterior groin as defined by zones and essential triangles and the technical steps to achieve the critical view of the MPO will foster the goal of safe MIS hernia repair, no matter which minimally invasive technique is employed.


Assuntos
Colecistectomia Laparoscópica/normas , Virilha/cirurgia , Hérnia Inguinal/cirurgia , Herniorrafia/normas , Cirurgia Endoscópica por Orifício Natural/normas , Colecistectomia Laparoscópica/métodos , Herniorrafia/métodos , Humanos , Cirurgia Endoscópica por Orifício Natural/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA