Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Methods Mol Biol ; 1906: 79-85, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30488386

RESUMO

Microchip electrophoresis is a versatile separation technique. Electrochemical detection is suitable to apply to microdevices due to its easy integration to the fabrication process and good sensitivity and selectivity. Here we describe the procedures to prepare Pt band electrodes deposited on glass to couple to polydimethylsiloxane (PDMS) microchips aiming the separation and detection of nitrite using an isolated potentiostat.


Assuntos
Dimetilpolisiloxanos/química , Eletroforese em Microchip/instrumentação , Nitritos/análise , Técnicas Biossensoriais/instrumentação , Eletrodos , Eletroforese em Microchip/métodos , Vidro
2.
Electrophoresis ; 35(23): 3363-70, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25224541

RESUMO

This report describes the use of PDMS ME coupled with amperometric detection for rapid separation of ascorbic, gallic , ferulic, p-coumaric acids using reverse polarity. ME devices were fabricated in PDMS by soft lithography and detection was accomplished using an integrated carbon fiber working electrode aligned in the end-channel configuration. Separation and detection parameters were investigated and the best conditions were obtained using a run buffer consisting of 5 mM phosphate buffer (pH 6.9) and a detection voltage of 1.0 V versus Ag/AgCl reference electrode. All compounds were separated within 70 s using gated injection mode with baseline resolution and separation efficiencies between 1200 and 9000 plates. Calibration curves exhibited good linearity and the LODs achieved ranged from 1.7 to 9.7 µM. The precision for migration time and peak height provided maximum values of 4% for the intrachip studies. Lastly, the analytical method was successfully applied for the analysis of ascorbic and gallic acids in commercial beverage samples. The results achieved using ME coupled with amperometric detection were in good agreement with the values provided by the supplier. Based on the data reported here, the proposed method shows suitability to be applied for the routine analysis of beverage samples.


Assuntos
Antioxidantes/análise , Dimetilpolisiloxanos/química , Eletroforese em Microchip/instrumentação , Eletroforese em Microchip/métodos , Nylons/química , Antioxidantes/química , Antioxidantes/isolamento & purificação , Bebidas/análise , Desenho de Equipamento , Limite de Detecção , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA