RESUMO
The granulocyte-macrophage colony stimulating factor (GM-CSF) is a cytokine that regulates the proliferation and differentiation of hematopoietic cells and activates granulocytes and macrophages. A reversed-phase liquid chromatography (RP-LC) method was validated for the assessing of the stability of non-glycosylated recombinant rhGM-CSF (Molgramostim) in biopharmaceutical formulations. The RP-LC method was carried out on a Jupiter C(4) column (250 mm × 4.6 mm i.d.), maintained at 45 °C. The mobile phase A consisted of 0.1% TFA and the mobile phase B was acetonitrile with 0.1% TFA in acetonitrile, run at a flow rate of 1 mL/min, and using photodiode array (PDA) detection at 214 nm. Chromatographic separation was obtained with a retention time of 29.2 min, and was linear over the concentration range of 2-300 µg/mL (r(2) = 0.9992). Specificity was established in degradation studies. Moreover, the in vitro cytotoxicity test of the degraded products showed significant differences (p < 0.05). The method was applied to the assessment of rhGM-CSF and related proteins in biopharmaceutical dosage forms, and the results were correlated to those of a bioassay. It is concluded that the employment of RP-LC in conjunction with current methods allows a great improvement in monitoring stability, quality control and thereby assures the therapeutic efficacy.
Assuntos
Estabilidade de Medicamentos , Fator Estimulador de Colônias de Granulócitos e Macrófagos/farmacologia , Preparações Farmacêuticas , Cromatografia Líquida , Limite de Detecção , Reprodutibilidade dos TestesRESUMO
A stability-indicating capillary zone electrophoresis (CZE) method was validated for the analysis of entecavir in pharmaceutical formulations, using nimesulide as an internal standard. A fused-silica capillary (50 µm i.d.; effective length, 40 cm) was used while being maintained at 25°C; the applied voltage was 25 kV. A background electrolyte solution consisted of a 20 mM sodium tetraborate solution at pH 10. Injections were performed using a pressure mode at 50 mbar for 5 s, with detection at 216 nm. The specificity and stability-indicating capability were proven through forced degradation studies, evaluating also the in vitro cytotoxicity test of the degraded products. The method was linear over the concentration range of 1-200 µg mL(-1) (r(2) = 0.9999), and was applied for the analysis of entecavir in tablet dosage forms. The results were correlated to those of validated conventional and fast LC methods, showing non-significant differences (p > 0.05).