Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Pediatr ; 181: 42-48.e2, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27837950

RESUMO

OBJECTIVE: To determine whether brain volume is reduced at 1 year of age and whether these volumes are associated with neurodevelopment in biventricular congenital heart disease (CHD) repaired in infancy. STUDY DESIGN: Infants with biventricular CHD (n = 48) underwent brain magnetic resonance imaging (MRI) and neurodevelopmental testing with the Bayley Scales of Infant Development-II and the MacArthur-Bates Communicative Development Inventories at 1 year of age. A multitemplate based probabilistic segmentation algorithm was applied to volumetric MRI data. We compared volumes with those of 13 healthy control infants of comparable ages. In the group with CHD, we measured Spearman correlations between neurodevelopmental outcomes and the residuals from linear regression of the volumes on corrected chronological age at MRI and sex. RESULTS: Compared with controls, infants with CHD had reductions of 54 mL in total brain (P = .009), 40 mL in cerebral white matter (P <.001), and 1.2 mL in brainstem (P = .003) volumes. Within the group with CHD, brain volumes were not correlated with Bayley Scales of Infant Development-II scores but did correlate positively with MacArthur-Bates Communicative Development Inventory language development. CONCLUSIONS: Infants with biventricular CHD show total brain volume reductions at 1 year of age, driven by differences in cerebral white matter. White matter volume correlates with language development, but not broader developmental indices. These findings suggest that abnormalities in white matter development detected months after corrective heart surgery may contribute to language impairment. TRIAL REGISTRATION: ClinicalTrials.gov: NCT00006183.


Assuntos
Cardiopatias Congênitas/cirurgia , Desenvolvimento da Linguagem , Imageamento por Ressonância Magnética/métodos , Substância Branca/diagnóstico por imagem , Substância Branca/crescimento & desenvolvimento , Desenvolvimento Infantil/fisiologia , Pré-Escolar , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/mortalidade , Humanos , Lactente , Recém-Nascido , Modelos Lineares , Masculino , Testes Neuropsicológicos , Tamanho do Órgão , Valor Preditivo dos Testes , Prognóstico , Valores de Referência , Taxa de Sobrevida , Cirurgia Torácica/métodos
2.
J Pediatr ; 177: 184-190.e3, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27499214

RESUMO

OBJECTIVE: To assess the feasibility and accuracy of inert gas rebreathing (IGR) pulmonary blood flow (Qp) estimation in mechanically ventilated pediatric patients, potentially providing real-time noninvasive estimates of cardiac output. STUDY DESIGN: In mechanically ventilated patients in the pediatric catheterization laboratory, we compared IGR Qp with Qp estimates based upon the Fick equation using measured oxygen consumption (VO2) (FickTrue); for context, we compared FickTrue with a standard clinical short-cut, replacing measured with assumed VO2 in the Fick equation (FickLaFarge, FickLundell, FickSeckeler). IGR Qp and breath-by-breath VO2 were measured using the Innocor device. Sampled pulmonary arterial and venous saturations and hemoglobin concentration were used for Fick calculations. Qp estimates were compared using Bland-Altman agreement and Spearman correlation. RESULTS: The final analysis included 18 patients aged 4-23 years with weight >15 kg. Compared with the reference FickTrue, IGR Qp estimates correlated best and had the least systematic bias and narrowest 95% limits of agreement (results presented as mean bias ±95% limits of agreement): IGR -0.2 ± 1.1 L/min, r = 0.90; FickLaFarge +0.7 ± 2.2 L/min, r = 0.80; FickLundell +1.6 ± 2.9 L/min, r = 0.83; FickSeckeler +0.8 ± 2.5 L/min, r = 0.83. CONCLUSIONS: IGR estimation of Qp is feasible in mechanically ventilated patients weighing >15 kg, and agreement with FickTrue Qp estimates is better for IGR than for other Fick Qp estimates commonly used in pediatric catheterization. IGR is an attractive option for bedside monitoring of Qp in mechanically ventilated children.


Assuntos
Débito Cardíaco , Testes de Função Cardíaca/métodos , Respiração Artificial , Adolescente , Testes Respiratórios , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Gases Nobres/administração & dosagem , Consumo de Oxigênio , Respiração , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA