Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Diabetes Care ; 46(2): 416-424, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36577120

RESUMO

OBJECTIVE: This study evaluates the relationship between atherosclerotic plaque characteristics (APCs) and angiographic stenosis severity in patients with and without diabetes. Whether APCs differ based on lesion severity and diabetes status is unknown. RESEARCH DESIGN AND METHODS: We retrospectively evaluated 303 subjects from the Computed TomogRaphic Evaluation of Atherosclerotic Determinants of Myocardial IsChEmia (CREDENCE) trial referred for invasive coronary angiography with coronary computed tomographic angiography (CCTA) and classified lesions as obstructive (≥50% stenosed) or nonobstructive using blinded core laboratory analysis of quantitative coronary angiography. CCTA quantified APCs, including plaque volume (PV), calcified plaque (CP), noncalcified plaque (NCP), low-density NCP (LD-NCP), lesion length, positive remodeling (PR), high-risk plaque (HRP), and percentage of atheroma volume (PAV; PV normalized for vessel volume). The relationship between APCs, stenosis severity, and diabetes status was assessed. RESULTS: Among the 303 patients, 95 (31.4%) had diabetes. There were 117 lesions in the cohort with diabetes, 58.1% of which were obstructive. Patients with diabetes had greater plaque burden (P = 0.004). Patients with diabetes and nonobstructive disease had greater PV (P = 0.02), PAV (P = 0.02), NCP (P = 0.03), PAV NCP (P = 0.02), diseased vessels (P = 0.03), and maximum stenosis (P = 0.02) than patients without diabetes with nonobstructive disease. APCs were similar between patients with diabetes with nonobstructive disease and patients without diabetes with obstructive disease. Diabetes status did not affect HRP or PR. Patients with diabetes had similar APCs in obstructive and nonobstructive lesions. CONCLUSIONS: Patients with diabetes and nonobstructive stenosis had an association to similar APCs as patients without diabetes who had obstructive stenosis. Among patients with nonobstructive disease, patients with diabetes had more total PV and NCP.


Assuntos
Aterosclerose , Doença da Artéria Coronariana , Estenose Coronária , Diabetes Mellitus , Placa Aterosclerótica , Humanos , Constrição Patológica/complicações , Estudos Retrospectivos , Doença da Artéria Coronariana/complicações , Placa Aterosclerótica/diagnóstico por imagem , Angiografia Coronária/métodos , Aterosclerose/complicações , Angiografia por Tomografia Computadorizada/métodos , Diabetes Mellitus/epidemiologia , Inteligência Artificial , Estenose Coronária/complicações , Valor Preditivo dos Testes
2.
Thromb. haemost ; Thromb. haemost;119(1): 149-162, Jan. 2019. gráfico, tabela
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1024675

RESUMO

BACKGROUND: Prolonged dual anti-platelet therapy (DAPT) is intended to reduce ischemic events, at the cost of an increased bleeding risk in patients undergoing percutaneous coronary intervention (PCI). In this study, we evaluated whether race influences the ischemia/bleeding risk trade-off. METHODS: We searched for randomized clinical trials (RCTs) comparing DAPT duration after PCI. To compare the benefit or harm between DAPT duration by race, individual patient-level landmark meta-analysis was performed after discontinuation of the shorter duration DAPT group in each RCT. The primary ischemic endpoint was major adverse cardiac events (MACEs), and the primary bleeding endpoint was major bleeding events (clinicaltrials.gov NCT03338335). RESULTS: Seven RCTs including 16,518 patients (8,605 East Asians, 7,913 non-East Asians) were pooled. MACE occurred more frequently in non-East Asians (0.8% vs. 1.8%, p < 0.001), while major bleeding events occurred more frequently in East Asians (0.6% vs. 0.3%, p = 0.001). In Cox proportional hazards model, prolonged DAPT significantly increased the risk of major bleeding in East Asians (hazard ratio [HR], 2.843, 95% confidence interval [CI], 1.474-5.152, p = 0.002), but not in non-East Asians (HR, 1.375, 95% CI, 0.523-3.616, p = 0.523). East Asians had a higher median probability risk ratio of bleeding to ischemia (0.66 vs. 0.15), and the proportion of patients with higher probability of bleeding than ischemia was significantly higher in East Asians (32.3% vs. 0.4%, p < 0.001). CONCLUSION: We suggest that the ischemia/bleeding trade-off may be different between East Asians and non-East Asians. In East Asians, prolonged DAPT may have no effect in reducing the ischemic risk, while significantly increases the bleeding risk. (AU)


Assuntos
Humanos , Inibidores da Agregação Plaquetária/uso terapêutico , Fatores Raciais
3.
Catheter Cardiovasc Interv ; 84(3): 377-85, 2014 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-23737441

RESUMO

INTRODUCTION: Although intravascular ultrasound minimal luminal area (IVUS-MLA) is one of many anatomic determinants of lesion severity, it has been proposed as an alternative to fractional flow reserve (FFR) to assess severity of coronary artery disease. OBJECTIVE: Pool the diagnostic performance of IVUS-MLA and determine its overall accuracy to predict the functional significance of coronary disease using FFR (0.75 or 0.80) as the gold standard. METHODS: Studies comparing IVUS and FFR to establish the best MLA cutoff value that correlates with significant coronary stenosis were reviewed from a Medline search using the terms "fractional flow reserve" and "ultrasound." DerSimonian Laird method was applied to obtain pooled accuracy. RESULTS: Eleven clinical trials, including two left main (LM) trials (total N = 1,759 patients, 1,953 lesions) were included. The weighted overall mean MLA cutoff was 2.61 mm(2) in non-LM trials and 5.35 mm(2) in LM trials. For non-LM lesions, the pooled sensitivity of MLA was 0.79 (95% CI = 0.76-0.83) and specificity was 0.65 (95% CI = 0.62-0.67). Positive likelihood ratio (LR) was 2.26 (95% CI = 1.98-2.57) and LR- was 0.32 (95% CI = 0.24-0.44). Area under the summary receiver operator curve for all trials was 0.848. Pooled LM trials had better accuracy: sensitivity = 0.90, specificity = 0.90, LR+ = 8.79, and LR- = 0.120. CONCLUSION: Given its limited pooled accuracy, IVUS-MLA's impact on clinical decision in this scenario is low and may lead to misclassification in up to 20% of the lesions. Pooled analysis points toward lower MLA cutoffs than the ones used in current practice.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Ultrassonografia de Intervenção/métodos , Vasos Coronários/fisiopatologia , Humanos , Prognóstico , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
4.
J Invasive Cardiol ; 24(10): 489-493, 2012.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1063687

RESUMO

The Sparrow stent system (Biosensors International) consists of a self-expanding, ultra-thin nitinol stent mounted within a 0.014½ guidewire designed for small or tortuous coronary lesions. We compared the intravascular ultrasound (IVUS) findings between the novel self-expanding sirolimus-eluting stent (Sparrow-SES) and a conventional balloon-expandable sirolimus-eluting stent (Cypher-SES) in patients with small coronary disease. Methods. We examined 14 lesions treated with the Sparrow-SES from CARE II, compared with 22 small vessel lesions treated with Cypher-SES. IVUS examination was performed post-procedure and 8 months later. Volumetric data were standardized by length as volume index (VI; mm3/mm). Results. While baseline stent VI trended smaller in Sparrow-SES, follow-up stent VI became similar between the 2 groups due to a significant increase of stent VI in self-expanding Sparrow-SES during the follow-up period. At 8 months, Sparrow-SES showed greater neointima than Cypher-SES (0.8 ± 0.6 mm3/mm vs 0.2 ± 0.2 mm3/mm; P<.001). However, the decrease in lumen VI was only 0.3 ± 0.7 mm3/mm in Sparrow-SES, as compared to 0.1 ± 0.3 mm3/mm in Cypher-SES (P=.259), since the late loss due to neointimal hyperplasia was partly counterbalanced by the chronic stent expansion in Sparrow-SES. Conclusion. While 8-month follow-up of Sparrow-SES revealed greater amounts of neointimal hyperplasia compared with conventional Cypher-SES, chronic stent expansion preserved the lumen by increasing stent volume. This novel, guidewire-based, self-expanding stent system designed to be delivered through complex anatomies may be useful to treat patients with small-caliber coronary lesions by offering sufficient lumen preservation at follow-up.


Assuntos
Doença da Artéria Coronariana , Doença das Coronárias , Stents Farmacológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA