Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
World J Plast Surg ; 10(3): 34-45, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34912665

RESUMO

BACKGROUND: We aimed to compare inflammatory and intercellular transcription responses induced by surface textured (ST) implants versus foam covered (FC) silicone implants placed on the dorsal aspect of rats. METHODS: We utilized 80 female rats of the Wistar lineage. The rats were divided into four subgroups of 20 with one type of implant placed in the dorsum per rat. Analysis was carried out on peri-implant capsules at 90 d and at 180 d post-surgery with microscopic evaluation of inflammatory and immuno-histochemical response of NF-κB-p65 and α-SMA in fibroblasts. This study was carried out at the Evangelical Faculty of Parana and at the Ivo Pitanguy Institute, Brazil in 2015. RESULTS: The FC exhibited higher levels of acute and chronic inflammation on evaluation in both time frames. The capsule surrounding the ST implants was significantly thicker with well-organized collagen fibres. NFκB-p65 expression in the capsule surrounding the FC implant was more pronounced. There was higher and more significant α-SMA expression in the capsules of the surface textured (ST) silicone implants compared to the foam-covered (FC) silicone implants. CONCLUSION: Activation of NFκB-p65 plays a key role in the evolution of capsule formation and maintenance of inflammation by regulating the healing process. Similarly, higher and more prolonged levels of inflammation (increased NF-κB-p65 results in increased inflammation) and lower α-SMA (higher α-SMA is protective against capsular contracture) did not directly translate to a thicker capsule and ultimately, capsular contracture in foam covered silicone implants.

2.
Plast Surg Int ; 2016: 6584810, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27092273

RESUMO

Background. Is the use of intraoperative breast sizers beneficial for plastic surgeons or do they result in higher complication rates? Methods. This is a retrospective study of 416 consecutive cases of primary breast augmentation with silicone implants at the Plastic Surgery Service of Professor Ivo Pitanguy at the 38th Infirmary Santa Casa Misericórdia Hospital, Rio De Janeiro, from January 2011 to March 2014. 212 cases (51%) were carried out with use of intraoperative breast sizers with 204 cases (49%) without the use of implant sizers. This study compares the outcome of cases that employed the use of intraoperative implant sizers versus those that did not in terms of infection, hematoma/seroma formation, and capsular contracture. Results. Of 416 primary breast augmentation cases, there were 5 cases of infection (1.2%), 4 cases of seroma (1%), 3 cases of hematoma (0.7%), and 7 cases of capsular contracture (Baker's Grade III/IV)(1.7%). Total complication rate limited to infection, seroma, hematoma, and capsular contracture was 1.15% (95% CI 0.96-1.93%). There was a significant difference in the scores for breast sizers (M = 4.3, SD = 1.4) and no breast sizers (M = 2.3, SD = 0.87) conditions, t(8) = 2.79, p = 0.018. The use of implant sizers was correlated with a higher complication rate. Conclusion. Good results could be obtained without the use of breast sizers in primary breast augmentation with use of a biodimensional tissue based planning system while eliminating risks of infection and reducing intraoperative time. Notwithstanding, in a residency program breast sizers can be an excellent training tool to shorten the learning curve in the novice surgeon.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA