Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Polymers (Basel) ; 15(3)2023 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-36772040

RESUMO

An electrochemical sensor for the pesticide Pirimicarb (PMC) has been developed. A screen-printed electrode (SPCE) was used and modified with the conducting polymer poly (3,4-ethylenedioxythiophene) (PEDOT) and gold nanoparticles (AuNPs) to enhance electrochemical proprieties. Electrode characterizations were performed using scattering electron microscopy (SEM) and cyclic voltammetry (CV). With the SPCE/PEDOT:PSS/AuNPs modified electrode, a new peak at 1.0 V appeared in the presence of PMC related to the PMC oxidation. To elucidate the mechanism of PMC oxidation, Gas Chromatography-Mass Spectrometry (GC-MS), where two major peaks were identified, evidencing that the device can both detect and degrade PMC by an electro-oxidation process. Exploring this peak signal, it was possible the sensor development, performing detection from 93.81-750 µmol L-1, limits of quantification (LOQ) and detection (LOD) of 93.91 µmol L-1 and 28.34 µmol L-1, respectively. Thus, it was possible to study and optimization of PMC degradation, moreover, to perform detection at low concentrations and with good selectivity against different interferents using a low-cost printed electrode based on graphite modified with conductive polymer and AuNPs.

2.
J Chromatogr Sci ; 56(6): 564-573, 2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-29608667

RESUMO

This study involved the development, validation and application of a three-phase hollow-fiber liquid-phase microextraction (HF-LPME) and liquid chromatography with diode array detection (LC-DAD) method for the simultaneous determination of the proton pump inhibitor (PPI) drugs omeprazole, pantoprazole and lansoprazole in human plasma. The evaluation of the HF-LPME parameters was crucial for the determination of the drugs and the conditions selected were: 1-octanol as solvent; phosphate buffer at pH 5 as donor phase; borate buffer at pH 10 as acceptor phase; extraction time of 15 min; stirring at 750 rpm and NaCl was added at 5% (w/v). Validation of the method according to US-FDA recommendations showed a good linear range (0.2-2.0 µg/mL) for all analytes, with a determination coefficient >0.9910. Precision was evaluated using intra- and inter-day assays, which showed relative standard deviations (RSD), <15% for all concentrations, with a limit of quantification (LOQ) of 0.2 µg/mL. Accuracy was also assessed at these concentration levels and was in the range from 80 to 130%. Finally, the sensitive, selective and reproducible HF-LPME/LC-DAD developed method was successfully applied to human plasma samples from patients undergoing therapy with the PPI drugs.


Assuntos
Cromatografia Líquida/métodos , Microextração em Fase Líquida/métodos , Inibidores da Bomba de Prótons/sangue , Humanos , Modelos Lineares , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA