Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
JMIR Med Inform ; 10(11): e40826, 2022 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-36274196

RESUMO

BACKGROUND: The quest for improved diagnosis and treatment in home health care models has led to the development of wearable medical devices for remote vital signs monitoring. An accurate signal and a high diagnostic yield are critical for the cost-effectiveness of wearable health care monitoring systems and their widespread application in resource-constrained environments. Despite technological advances, the information acquired by these devices can be contaminated by motion artifacts (MA) leading to misdiagnosis or repeated procedures with increases in associated costs. This makes it necessary to develop methods to improve the quality of the signal acquired by these devices. OBJECTIVE: We aimed to present a novel method for electrocardiogram (ECG) signal denoising to reduce MA. We aimed to analyze the method's performance and to compare its performance to that of existing approaches. METHODS: We present the novel Redundant denoising Independent Component Analysis method for ECG signal denoising based on the redundant and simultaneous acquisition of ECG signals and movement information, multichannel processing, and performance assessment considering the information contained in the signal waveform. The method is based on data including ECG signals from the patient's chest and back, the acquisition of triaxial movement signals from inertial measurement units, a reference signal synthesized from an autoregressive model, and the separation of interest and noise sources through multichannel independent component analysis. RESULTS: The proposed method significantly reduced MA, showing better performance and introducing a smaller distortion in the interest signal compared with other methods. Finally, the performance of the proposed method was compared to that of wavelet shrinkage and wavelet independent component analysis through the assessment of signal-to-noise ratio, dynamic time warping, and a proposed index based on the signal waveform evaluation with an ensemble average ECG. CONCLUSIONS: Our novel ECG denoising method is a contribution to converting wearable devices into medical monitoring tools that can be used to support the remote diagnosis and monitoring of cardiovascular diseases. A more accurate signal substantially improves the diagnostic yield of wearable devices. A better yield improves the devices' cost-effectiveness and contributes to their widespread application.

2.
Sensors (Basel) ; 21(14)2021 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-34300562

RESUMO

Wearable vital signs monitoring and specially the electrocardiogram have taken important role due to the information that provide about high-risk diseases, it has been evidenced by the needed to increase the health service coverage in home care as has been encouraged by World Health Organization. Some wearables devices have been developed to monitor the Electrocardiographic in which the location of the measurement electrodes is modified respect to the Einthoven model. However, mislocation of the electrodes on the torso can lead to the modification of acquired signals, diagnostic mistakes and misinterpretation of the information in the signal. This work presents a volume conductor evaluation and an Electrocardiographic signal waveform comparison when the location of electrodes is changed, to find a electrodes' location that reduces distortion of interest signals. In addition, effects of motion artifacts and electrodes' location on the signal acquisition are evaluated. A group of volunteers was recorded to obtain Electrocardiographic signals, the result was compared with a computational model of the heart behavior through the Ensemble Average Electrocardiographic, Dynamic Time Warping and Signal-to-Noise Ratio methods to quantitatively determine the signal distortion. It was found that while the Einthoven method is followed, it is possible to acquire the Electrocardiographic signal from the patient's torso or back without a significant difference, and the electrodes position can be moved 6 cm at most from the suggested location by the Einthoven triangle in Mason-Likar's method.


Assuntos
Artefatos , Dispositivos Eletrônicos Vestíveis , Eletrocardiografia , Eletrodos , Humanos , Processamento de Sinais Assistido por Computador
3.
Am J Physiol Heart Circ Physiol ; 320(4): H1235-H1260, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33416450

RESUMO

The use of physiological models in medicine allows the evaluation of new hypotheses, development of diagnosis and clinical treatment applications, and development of training and medical education tools, as well as medical device design. Although several mathematical models of physiological systems have been presented in the literature, few of them are able to predict the human cardiorespiratory response under physical exercise stimulus adequately. This paper aims to present the building and comparison of an integrated cardiorespiratory model focused on the prediction of the healthy human response under rest and aerobic exercise. The model comprises cardiovascular circulation, respiratory mechanics, and gas exchange system, as well as cardiovascular and respiratory controllers. Every system is based on previously reported physiological models and incorporates reported mechanisms related to the aerobic exercise dynamics. Experimental data of 30 healthy male volunteers undergoing a cardiopulmonary exercise test and simulated data from two of the most current and complete cardiorespiratory models were used to evaluate the performance of the presented model. Experimental design, processing, and exploratory analysis are described in detail. The simulation results were compared against the experimental data in steady state and in transient regime. The predictions of the proposed model closely mimic the experimental data, showing in overall the lowest prediction error (10.35%), the lowest settling times for cardiovascular and respiratory variables, and in general the fastest and similar responses in transient regime. These results suggest that the proposed model is suitable to predict the cardiorespiratory response of healthy adult humans under rest and aerobic exercise conditions.NEW & NOTEWORTHY This paper presents a new cardiorespiratory model focused on the prediction of the healthy human response under rest and aerobic dynamic exercise conditions. Simulation results of cardiorespiratory variables are compared against experimental data and two of the most current and complete cardiorespiratory models.


Assuntos
Vasos Sanguíneos/fisiologia , Simulação por Computador , Exercício Físico , Coração/fisiologia , Hemodinâmica , Pulmão/fisiologia , Modelos Cardiovasculares , Respiração , Adaptação Fisiológica , Adolescente , Adulto , Aptidão Cardiorrespiratória , Humanos , Masculino , Pessoa de Meia-Idade , Descanso , Fatores de Tempo , Adulto Jovem
4.
Drug Deliv ; 27(1): 864-875, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32515999

RESUMO

Therapeutic drugs for Alzheimer's disease have been extensively studied due to its recurrence and abundance among neurodegenerative diseases. It is thought that the accumulation of amyloid precursor protein (APP) products, a consequence of an up-regulation of the ß-site APP-cleaving enzyme 1 (BACE1), is the main triggering mechanism during the early stages of the disease. This study aims to explore the ability of a multifunctional conjugate based on magnetite nanoparticles for the cellular delivery of siRNA against the expression of the BACE1 gene. We immobilized the siRNA strand on PEGylated magnetite nanoparticles and investigated the effects on biocompatibility and efficacy of the conjugation. Similarly, we co-immobilized the translocating protein OmpA on PEGylated nanoparticles to enhance cellular uptake and endosomal escape. BACE1 suppression was statistically significant in HFF-1 cells, without any presence of a cytotoxic effect. The delivery of the nanoconjugate was achieved through endocytosis pathways, where endosome formation was likely escaped due to the proton-sponge effect characteristic of PEGylated nanoparticles or mainly by direct translocation in the case of OmpA/PEGylated nanoparticles.


Assuntos
Doença de Alzheimer , Secretases da Proteína Precursora do Amiloide/genética , Ácido Aspártico Endopeptidases/genética , Inativação Gênica , Nanopartículas de Magnetita/uso terapêutico , RNA Interferente Pequeno/uso terapêutico , Doença de Alzheimer/genética , Doença de Alzheimer/terapia , Animais , Encéfalo/metabolismo , Linhagem Celular , Endocitose/fisiologia , Endossomos/metabolismo , Técnicas de Transferência de Genes , Humanos , Teste de Materiais
5.
Respir Physiol Neurobiol ; 258: 76-81, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29886247

RESUMO

The hypothesis of this study is that muscular activity measured through surface electromyography (sEMG) is useful to estimate the work of breathing (WOB) and respiratory mechanics. Thirty-two healthy volunteers were non-invasively ventilated, and an airflow resistor was attached to the airway circuit. sEMG signals from diaphragm, intercostal and sternocleidomastoid muscles were processed and compared with WOB changes. The airway resistance was increased from a median of 9.58 to 22.51 cmH2O/L/s adding a resistance of 20 cmH2O/L/s, achieving the lower compliance too. The respiratory mechanics changes implied linear increases in WOB, with Pearson correlation of 88.43% respect to changes in resistance. Muscles increased their activity in agreement with changes of WOB, being higher the increment in diaphragm followed by sternocleidomastoid. The non-invasively monitored respiratory muscles activity allowed evaluating the changes in WOB when it depends on addition of obstructive loads, confirming that it could be used to improve the available respiratory mechanics and WOB monitoring tools.


Assuntos
Ventilação não Invasiva/métodos , Síndrome do Desconforto Respiratório/fisiopatologia , Mecânica Respiratória/fisiologia , Músculos Respiratórios/fisiologia , Trabalho Respiratório , Adulto , Eletromiografia , Potencial Evocado Motor/fisiologia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Estudos Retrospectivos , Estatísticas não Paramétricas , Adulto Jovem
6.
Rev. Fac. Med. (Bogotá) ; 65(2): 321-328, Apr.-June 2017. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-896722

RESUMO

Resumen Introducción. Por lo general, la mecánica ventilatoria se ha estimado en modo controlado con el uso de aproximaciones no adecuadas para ventilación espontánea. Objetivo. Medir los cambios de la mecánica ventilatoria ante variaciones de la presión positiva al final de la expiración (PEEP, por su sigla en inglés) y la presión soporte (PS) en ventilación mecánica no invasiva. Materiales y métodos. A través de una estrategia no invasiva, se estimó la mecánica ventilatoria bajo diferentes niveles de PEEP y PS. Para tal fin, se utilizó un simulador mecánico y se registró una base de datos de 14 sujetos sanos conectados de manera no invasiva a un ventilador mecánico. Resultados. Se obtuvieron valores medianos de resistencia y compliancia de 91.2[77.8-135.9]mL/cmH2O y 8.3[6.1-10.4]cmH2O/L/s para los 14 sujetos sanos con PEEP y PS de 0 cmH2O, respectivamente. En los incrementos de PEEP, los sujetos presentaron aumento estadísticamente significativo en la compliancia. Por el contrario, en el incremento de presión soporte, no se observaron cambios de ningún parámetro. Conclusiones. Se encontraron valores de compliancia y resistencia, acordes con los configurados en el simulador mecánico y coherentes con los reportados en la literatura en el caso de sujetos sanos. Esto resulta de gran utilidad al tomar decisiones en unidades de cuidados intensivos.


Abstract Introduction: Traditionally, ventilatory mechanics has been delivered in controlled modes through the use of inappropriate approaches for spontaneous ventilation. Objective: To measure the changes of ventilatory mechanics caused by PEEP and pressure support (PS) variations in non-invasive mechanical ventilation. Materials and methods: The ventilatory mechanics was evaluated through a non-invasive strategy, under different PEEP and pressure support levels. For this purpose, a mechanical simulator was used, and a database of 14 healthy subjects non-invasively connected to a mechanical ventilator was recorded. Results: For the 14 healthy subjects under PEEP and pressure support conditions of 0 cmH2O, the median resistance and compliance values were 91.2 [77.8-135.9] mL/cmH2O and 8.3[6.1-10.4]cmH2O/L/s, respectively. PEEP compliance showed a statistically significant increase in all subjects. On the other hand, no changes in any of the parameters were observed regarding pressure support increase. Conclusions: The proposed technique allowed to find compliance and resistance values consistent with those set in the mechanical simulator, which, in turn, coincide with those reported in the literature for healthy subjects. This information is useful for decision-making in intensive care units.

7.
J Alzheimers Dis ; 58(4): 1229-1244, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28550254

RESUMO

BACKGROUND: Presenilin-1 (PSEN1) mutations are the most common cause of familial early onset Alzheimer's disease (AD). The PSEN1 E280A (E280A) mutation has an autosomal dominant inheritance and is involved in the production of amyloid-ß. The largest family group of carriers with E280A mutation is found in Antioquia, Colombia. The study of mutation carriers provides a unique opportunity to identify brain changes in stages previous to AD. Electroencephalography (EEG) is a low cost and minimally invasiveness technique that enables the following of brain changes in AD. OBJECTIVE: To examine how previous reported differences in EEG for Theta and Alpha-2 rhythms in E280A subjects are related to specific regions in cortex and could be tracked across different ages. METHODS: EEG signals were acquired during resting state from non-carriers and carriers, asymptomatic and symptomatic subjects from E280A kindred from Antioquia, Colombia. Independent component analysis (ICA) and inverse solution methods were used to locate brain regions related to differences in Theta and Alpha-2 bands. RESULTS: ICA identified two components, mainly related to the Precuneus, where the differences in Theta and Alpha-2 exist simultaneously at asymptomatic and symptomatic stages. When the ratio between Theta and Alpha-2 is used, significant correlations exist with age and a composite cognitive scale. CONCLUSION: Theta and Alpha-2 rhythms are altered in E280A subjects. The alterations are possible to track at Precuneus regions using EEG, ICA, and inverse solution methods.


Assuntos
Doença de Alzheimer/genética , Doença de Alzheimer/patologia , Ondas Encefálicas/genética , Lobo Parietal/fisiopatologia , Polimorfismo de Nucleotídeo Único/genética , Presenilina-1/genética , Adulto , Alanina/genética , Doença de Alzheimer/complicações , Doença de Alzheimer/fisiopatologia , Mapeamento Encefálico , Ondas Encefálicas/fisiologia , Transtornos Cognitivos/etiologia , Transtornos Cognitivos/genética , Eletroencefalografia , Feminino , Ácido Glutâmico/genética , Humanos , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos , Análise de Componente Principal , Escalas de Graduação Psiquiátrica , Adulto Jovem
8.
Sensors (Basel) ; 17(5)2017 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-28468268

RESUMO

The traditional neurosurgical apprenticeship scheme includes the assessment of trainee's manual skills carried out by experienced surgeons. However, the introduction of surgical simulation technology presents a new paradigm where residents can refine surgical techniques on a simulator before putting them into practice in real patients. Unfortunately, in this new scheme, an experienced surgeon will not always be available to evaluate trainee's performance. For this reason, it is necessary to develop automatic mechanisms to estimate metrics for assessing manual dexterity in a quantitative way. Authors have proposed some hardware-software approaches to evaluate manual dexterity on surgical simulators. This paper presents IGlove, a wearable device that uses inertial sensors embedded on an elastic glove to capture hand movements. Metrics to assess manual dexterity are estimated from sensors signals using data processing and information analysis algorithms. It has been designed to be used with a neurosurgical simulator called Daubara NS Trainer, but can be easily adapted to another benchtop- and manikin-based medical simulators. The system was tested with a sample of 14 volunteers who performed a test that was designed to simultaneously evaluate their fine motor skills and the IGlove's functionalities. Metrics obtained by each of the participants are presented as results in this work; it is also shown how these metrics are used to automatically evaluate the level of manual dexterity of each volunteer.


Assuntos
Luvas Protetoras , Competência Clínica , Mãos , Humanos , Manequins , Software
9.
J Alzheimers Dis ; 55(3): 1195-1205, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27792014

RESUMO

BACKGROUND: Recent studies report increases in neural activity in brain regions critical to episodic memory at preclinical stages of Alzheimer's disease (AD). Although electroencephalography (EEG) is widely used in AD studies, given its non-invasiveness and low cost, there is a need to translate the findings in other neuroimaging methods to EEG. OBJECTIVE: To examine how the previous findings using functional magnetic resonance imaging (fMRI) at preclinical stage in presenilin-1 E280A mutation carriers could be assessed and extended, using EEG and a connectivity approach. METHODS: EEG signals were acquired during resting and encoding in 30 normal cognitive young subjects, from an autosomal dominant early-onset AD kindred from Antioquia, Colombia. Regions of the brain previously reported as hyperactive were used for connectivity analysis. RESULTS: Mutation carriers exhibited increasing connectivity at analyzed regions. Among them, the right precuneus exhibited the highest changes in connectivity. CONCLUSION: Increased connectivity in hyperactive cerebral regions is seen in individuals, genetically-determined to develop AD, at preclinical stage. The use of a connectivity approach and a widely available neuroimaging technique opens the possibility to increase the use of EEG in early detection of preclinical AD.


Assuntos
Doença de Alzheimer/fisiopatologia , Doença de Alzheimer/psicologia , Mapeamento Encefálico , Encéfalo/patologia , Memória Episódica , Vias Neurais/fisiologia , Adulto , Doença de Alzheimer/epidemiologia , Doença de Alzheimer/genética , Doenças Assintomáticas/epidemiologia , Doenças Assintomáticas/psicologia , Encéfalo/fisiopatologia , Colômbia/epidemiologia , Imagem de Difusão por Ressonância Magnética , Eletroencefalografia , Entropia , Feminino , Lateralidade Funcional , Humanos , Masculino , Mutação/genética , Testes Neuropsicológicos , Estimulação Luminosa , Presenilina-1/genética , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA