Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Braz J Cardiovasc Surg ; 35(4): 465-470, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32864925

RESUMO

OBJECTIVES: Stroke is an important cause of mortality and morbidity in surgery. In the present study, we examined the cerebral oximetry values of patients with carotid artery stenosis who did not present surgical indications and those who did not present carotid artery stenosis in coronary artery bypass grafting (CABG) surgery by comparing their cerebral oximetry values with cerebrovascular disease (CVD). METHODS: Between January and May 2014, 40 patients who underwent isolated CABG were included in the study. Cerebral oximetry probes were placed prior to induction of anesthesia. Cerebral oximetry values were recorded before induction, in the pump (cardiopulmonary bypass) inlet period, in the post-clamp period, in the pump outlet period, and in the intensive care unit and neurological complications. RESULTS: There was no difference between the groups in terms of demographic data and routine follow-up parameters. Intraoperative surgical data and early postoperative results were similar in both groups. When comparing the groups, there were no statistically significant results in cerebral oximetry values and CVD development. Only one patient in group 2 had postoperative CVD and this patient was discharged from the hospital with right hemiplegia. Mean arterial pressure (MAP)levels were significantly higher in Group 2 (P<0.05). CONCLUSION: The follow-up of cerebral perfusion with a method like near-infrared spectroscopy (NIRS) will ensure that MAP is adjusted with interventions that will be made according to changes in NIRS. Thus, it will be possible to avoid unnecessary medication and flow-rate increase with cerebral oxygen saturation (rSO2) follow-up.


Assuntos
Estenose das Carótidas , Idoso , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Circulação Cerebrovascular , Ponte de Artéria Coronária , Feminino , Humanos , Masculino , Margens de Excisão , Pessoa de Meia-Idade , Oximetria , Oxigênio , Espectroscopia de Luz Próxima ao Infravermelho
2.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;35(4): 465-470, July-Aug. 2020. tab
Artigo em Inglês | LILACS, Sec. Est. Saúde SP | ID: biblio-1137307

RESUMO

Abstract Objectives: Stroke is an important cause of mortality and morbidity in surgery. In the present study, we examined the cerebral oximetry values of patients with carotid artery stenosis who did not present surgical indications and those who did not present carotid artery stenosis in coronary artery bypass grafting (CABG) surgery by comparing their cerebral oximetry values with cerebrovascular disease (CVD). Methods: Between January and May 2014, 40 patients who underwent isolated CABG were included in the study. Cerebral oximetry probes were placed prior to induction of anesthesia. Cerebral oximetry values were recorded before induction, in the pump (cardiopulmonary bypass) inlet period, in the post-clamp period, in the pump outlet period, and in the intensive care unit and neurological complications. Results: There was no difference between the groups in terms of demographic data and routine follow-up parameters. Intraoperative surgical data and early postoperative results were similar in both groups. When comparing the groups, there were no statistically significant results in cerebral oximetry values and CVD development. Only one patient in group 2 had postoperative CVD and this patient was discharged from the hospital with right hemiplegia. Mean arterial pressure (MAP)levels were significantly higher in Group 2 (P<0.05). Conclusion: The follow-up of cerebral perfusion with a method like near-infrared spectroscopy (NIRS) will ensure that MAP is adjusted with interventions that will be made according to changes in NIRS. Thus, it will be possible to avoid unnecessary medication and flow-rate increase with cerebral oxygen saturation (rSO2) follow-up.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Estenose das Carótidas/cirurgia , Estenose das Carótidas/diagnóstico por imagem , Oxigênio , Oximetria , Circulação Cerebrovascular , Ponte de Artéria Coronária , Espectroscopia de Luz Próxima ao Infravermelho , Margens de Excisão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA