1.
Micromachines (Basel) ; 14(5)2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37241682

RESUMO

Nowadays, there is no doubt about the high electrocatalytic efficiency that is obtained when using hybrid materials between carbonaceous nanomaterials and transition metal oxides. However, the method to prepare them may involve differences in the observed analytical responses, making it necessary to evaluate them for each new material. The goal of this work was to obtain for the first time Co2SnO4 (CSO)/RGO nanohybrids via in situ and ex situ methods and to evaluate their performance in the amperometric detection of hydrogen peroxide. The electroanalytical response was evaluated in NaOH pH 12 solution using detection potentials of -0.400 V or 0.300 V for the reduction or oxidation of H2O2. The results show that for CSO there were no differences between the nanohybrids either by oxidation or by reduction, unlike what we previously observed with cobalt titanate hybrids, in which the in situ nanohybrid clearly had the best performance. On the other hand, no influence in the study of interferents and more stable signals were obtained when the reduction mode was used. In conclusion, for detecting hydrogen peroxide, any of the nanohybrids studied, i.e., in situ or ex situ, are suitable to be used, and more efficiency is obtained using the reduction mode.

2.
Talanta ; 242: 123290, 2022 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-35151082

RESUMO

This work reports for the first time the analytical performance of glassy carbon electrodes (GCE) modified with a dispersion of multi-wall carboxylated carbon nanotubes (MWCNTs-COOH) using a mixture of a natural deep eutectic solvent (NADES - LGH/lactic acid-glucose-water), ethylene glycol (EG) and water (GCE/MWCNT-LGH-EG) for the determination and N-(4-hydroxyphenyl) acetamide (paracetamol) (APAP) in urine samples. The optimization of both dispersion and measurement conditions was carried out using experimental design. The modified electrode exhibited enhanced current responses, demonstrating excellent electrochemical response towards APAP oxidation compared to MWCNTs-LGH, MWCNTs-EG, MWCNTs-H2O-EtOH and MWCNTs-H2O. The linear dependence between the anodic peak currents and the square root of scan rates over the range of 0.010-0.300 Vs-1 demonstrates that the electro oxidation of APAP occurs under diffusional control. The MWCNT-LGH-EG modified GCE displayed an analytical sensitivity of 10.72 mL µg-1 (r = 0.9994) and a detection limit of 100 ng mL-1 for the selective determination of APAP in urine samples. The proposed electrochemical sensor was successfully applied for quantifying APAP in urine samples in the presence of uric acid. In addition, the accuracy and precision of the method was contrasted against a HPLC reference method.


Assuntos
Nanotubos de Carbono , Acetaminofen , Solventes Eutéticos Profundos , Técnicas Eletroquímicas/métodos , Eletrodos , Limite de Detecção , Solventes
3.
Anal Bioanal Chem ; 412(15): 3539-3546, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32239259

RESUMO

This work is focused on the development of a genosensor for microRNA-21 quantification using surface plasmon resonance (SPR) to transduce the hybridization event. The biosensing platform was built by self-assembling two bilayers of poly(diallyldimethylammonium chloride) (PDDA) and graphene oxide (GO) at a gold surface modified with 3-mercaptopropane sulfonate (MPS), followed by the covalent attachment of the DNA probe. GO was used in two directions, to allow the anchoring of the probe DNA and to increase the sensitivity of the biosensing event due to its field enhancer effect. The new bioanalytical platform represents an interesting alternative for the label-free biosensing of microRNA-21, with a linear range between 1.0 fM and 10 nM, a sensitivity of 5.1 ± 0.1 moM-1 and a detection limit of 0.3fM. The proposed sensing strategy was successfully used for the quantification of microRNA-21 in enriched urine samples. Graphical abstract.


Assuntos
Grafite/química , MicroRNAs/urina , Ressonância de Plasmônio de Superfície/métodos , Sondas de DNA/química , Ouro/química , Humanos , Limite de Detecção , MicroRNAs/análise , Polietilenos/química , Compostos de Amônio Quaternário/química
4.
Nanomaterials (Basel) ; 9(11)2019 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-31766234

RESUMO

For the first time, the synthesis, characterization, and analytical application for hydrogen peroxide quantification of the hybrid materials of Co2TiO4 (CTO) and reduced graphene oxide (RGO) is reported, using in situ (CTO/RGO) and ex situ (CTO+RGO) preparations. This synthesis for obtaining nanostructured CTO is based on a one-step hydrothermal synthesis, with new precursors and low temperatures. The morphology, structure, and composition of the synthesized materials were examined using scanning electron microscopy, X-ray diffraction (XRD), neutron powder diffraction (NPD), and X-ray photoelectron spectroscopy (XPS). Rietveld refinements using neutron diffraction data were conducted to determine the cation distributions in CTO. Hybrid materials were also characterized by Brunauer-Emmett-Teller adsorption isotherms, Scanning Electron microscopy, and scanning electrochemical microscopy. From an analytical point of view, we evaluated the electrochemical reduction of hydrogen peroxide on glassy carbon electrodes modified with hybrid materials. The analytical detection of hydrogen peroxide using CTO/RGO showed 11 and 5 times greater sensitivity in the detection of hydrogen peroxide compared with that of pristine CTO and RGO, respectively, and a two-fold increase compared with that of the RGO+CTO modified electrode. These results demonstrate that there is a synergistic effect between CTO and RGO that is more significant when the hybrid is synthetized through in situ methodology.

5.
Biosens Bioelectron ; 86: 308-314, 2016 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-27387261

RESUMO

We report for the first time the use of single-walled carbon nanotubes (SWCNT) covalently functionalized with polytyrosine (Polytyr) (SWCNT-Polytyr) as a new electrode material for the development of nicotinamide adenine dinucleotide (NADH)-based biosensors. The oxidation of glassy carbon electrodes (GCE) modified with SWCNT-Polytyr at potentials high enough to oxidize the tyrosine residues have allowed the electrooxidation of NADH at low potentials due to the catalytic activity of the quinones generated from the primary oxidation of tyrosine without any additional redox mediator. The amperometric detection of NADH at 0.200V showed a sensitivity of (217±3)µAmM(-1)cm(-2) and a detection limit of 7.9nM. The excellent electrocatalytic activity of SWCNT-Polytyr towards NADH oxidation has also made possible the development of a sensitive ethanol biosensor through the immobilization of alcohol dehydrogenase (ADH) via Nafion entrapment, with excellent analytical characteristics (sensitivity of (5.8±0.1)µAmM(-1)cm(-2), detection limit of 0.67µM) and very successful application for the quantification of ethanol in different commercial beverages.


Assuntos
Álcool Desidrogenase/química , Condutometria/instrumentação , Etanol/análise , NAD/análise , Nanotubos de Carbono/química , Peptídeos/química , Enzimas Imobilizadas/química , Desenho de Equipamento , Análise de Falha de Equipamento , NAD/química , Nanoconjugados/química , Nanoconjugados/ultraestrutura , Nanotubos de Carbono/ultraestrutura , Oxirredução , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Anal Chim Acta ; 909: 51-9, 2016 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-26851084

RESUMO

This work reports the synthesis and characterization of single-walled carbon nanotubes (SWCNT) covalently functionalized with polytyrosine (Polytyr); the critical analysis of the experimental conditions to obtain the efficient dispersion of the modified carbon nanotubes; and the analytical performance of glassy carbon electrodes (GCE) modified with the dispersion (GCE/SWCNT-Polytyr) for the highly sensitive quantification of polyphenols. Under the optimal conditions, the calibration plot for the amperometric response of gallic acid (GA) shows a linear range between 5.0 × 10(-7) and 1.7 × 10(-4) M, with a sensitivity of (518 ± 5) m AM(-1) cm(-2), and a detection limit of 8.8 nM. The proposed sensor was successfully used for the determination of total polyphenolic content in tea extracts.


Assuntos
Nanotubos de Carbono/química , Peptídeos/química , Polifenóis/análise , Eletrodos , Ácido Gálico/química , Estrutura Molecular
7.
Biosens Bioelectron ; 41: 424-9, 2013 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-23017682

RESUMO

This work reports the characterization of a modified gold surface as a platform for the development of a label free aptasensor for thrombin detection. The biorecognition platform was obtained by the self-assembly of 4-mercaptobenzoic acid onto a gold surface, covalent attachment of streptavidin and further immobilization of the biotinylated anti-thrombin aptamer. The biosensing platform was characterized by cyclic voltammetry, electrochemical impedance spectroscopy, surface plasmon resonance (SPR) and quartz crystal microbalance with dissipation monitoring. The biorecognition event aptamer-thrombin was detected from changes in the SPR angle produced as a consequence of the molecular interaction between the aptasensor and the target protein. The biosensing platform demonstrated to be highly selective for human thrombin even in the presence of large excess of bovine thrombin, bovine serum albumin, cytochrome C, lysozyme and myoglobin. The relationship between the changes in the SPR angle and thrombin concentration was linear up to 0.19 µmol L(-1) (R(2)=0.992) while the detection limit was of 12.0 nmol L(-1) (240 fmol in the sample). This new sensing approach represents an interesting and promising alternative for the SPR-based quantification of thrombin.


Assuntos
Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/instrumentação , Testes de Coagulação Sanguínea/instrumentação , Condutometria/instrumentação , Imunoensaio/instrumentação , Trombina/análise , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Trombina/antagonistas & inibidores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA