Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Radiat Res ; 198(2): 134-144, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35504003

RESUMO

Boron neutron capture therapy (BNCT) is a treatment modality for cancer that involves radiations of different qualities. A formalism that proved suitable to compute doses in photon-equivalent units is the photon isoeffective dose model. This study addresses the question whether considering in vitro or in vivo radiobiological studies to determine the parameters involved in photon isoeffective dose calculations affects the consistency of the model predictions. The analysis is focused on head and neck squamous cell carcinomas (HNSCC), a main target that proved to respond to BNCT. The photon isoeffective dose model for HNSCC with parameters from in vitro studies using the primary human cell line UT-SCC-16A was introduced and compared to the one previously reported with parameters from an in vivo oral cancer model in rodents. Both models were first compared in a simple scenario by means of tumor dose and control probability calculations. Then, the clinical impact of the different dose models was assessed from the analysis of a group of squamous cell carcinomas (SCC) patients treated with BNCT. Traditional dose calculations using the relative biological effectiveness factors derived from the SCC cell line were also analyzed. Predictions of tumor control from the evaluated models were compared to the patients' outcome. The quantification of the biological effectiveness of the different radiations revealed that relative biological effectiveness/compound biological effectiveness (RBE/CBE) factors for the SCC cell line are up to 20% higher than those assumed in clinical BNCT, highlighting the importance of using experimental data intimately linked to the tumor type to derive the model's parameters. The comparison of the different models showed that photon isoeffective doses based on in vitro data are generally greater than those from in vivo data (∼8-16% for total tumor absorbed doses of 10-15 Gy). However, the predictive power of the two models was not affected by these differences: both models fulfilled conditions to guarantee a good predictive performance and gave predictions statistically compatible with the clinical outcome. On the other hand, doses computed with the traditional model were substantially larger than those obtained with both photon isoeffective models. Moreover, the traditional model is statistically rejected, which reinforces the assertion that its inconsistencies are intrinsic and not due to the use of RBE/CBE factors obtained for a tumor type different from HN cancer. The results suggest that the nature of the radiobiological data would not affect the consistency of the photon isoeffective dose model in the studied cases of SCC head and neck cancer treated with BPA-based BNCT.


Assuntos
Terapia por Captura de Nêutron de Boro , Carcinoma de Células Escamosas , Neoplasias de Cabeça e Pescoço , Terapia por Captura de Nêutron de Boro/métodos , Carcinoma de Células Escamosas/radioterapia , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Fótons/uso terapêutico , Eficiência Biológica Relativa , Carcinoma de Células Escamosas de Cabeça e Pescoço
2.
Phys Med ; 89: 282-292, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34474326

RESUMO

PURPOSE: Boron Neutron Capture Therapy (BNCT) is a form of hadrontherapy based on the selective damage caused by the products of neutron capture in 10B to tumour cells. BNCT dosimetry strongly depends on the parameters of the dose calculation models derived from radiobiological experiments. This works aims at determining an adequate dosimetry for in-vitro experiments involving irradiation of monolayer-cultured cells with photons and BNCT and assessing its impact on clinical settings. M&M: Dose calculations for rat osteosarcoma UMR-106 and human metastatic melanoma Mel-J cell survival experiments were performed using MCNP, transporting uncharged particles for KERMA determinations, and secondary particles (electrons, protons, 14C, 4He and 7Li) to compute absorbed dose in cultures. Dose-survival curves were modified according to the dose correction factors determined from computational studies. New radiobiological parameters of the photon isoeffective dose models for osteosarcoma and metastatic melanoma tumours were obtained. Dosimetry implications considering cutaneous melanoma patients treated in Argentina with BNCT were assessed and discussed. RESULTS: KERMA values for the monolayer-cultured cells overestimate absorbed doses of radiation components of interest in BNCT. Detailed dose calculations for the osteosarcoma irradiation increased the relative biological effectiveness factor RBE1% of the neutron component in more than 30%. The analysis based on melanoma cases reveals that the use of survival curves based on KERMA leads to an underestimation of the tumour doses delivered to patients. CONCLUSIONS: Considering detailed dose calculation for in-vitro experiments significantly impact on the prediction of the tumor control in patients. Therefore, proposed methods are clinically relevant.


Assuntos
Terapia por Captura de Nêutron de Boro , Melanoma , Neoplasias Cutâneas , Animais , Humanos , Masculino , Melanoma/radioterapia , Radiometria , Ratos , Eficiência Biológica Relativa
3.
Appl Radiat Isot ; 165: 109331, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32777741

RESUMO

In Argentina, a multi-institutional project has been established to assess the feasibility of applying BNCT ex-situ to the treatment of patients with multiple metastases in both lungs. Within this context, this work aims at applying the neutron autoradiography technique to study boron microdistribution in the lung. A comprehensive analysis of the different aspects for the generation of autoradiographic images of both normal and metastatic BDIX rat lungs was achieved. Histology, boron uniformity, optimal tissue thickness and water content in tissue were explored for the two types of samples. A qualitative and a quantitative analysis were performed. No heterogeneities in uptake were observed in normal lung. Conversely, samples with metastasis showed preferential boron uptake in the tumour areas with respect to surrounding tissue. Surrounding tissue would present a slightly higher uptake of boron than the normal lung. Quantitative results of boron concentration values and ratios determined by neutron autoradiography were obtained. In order to contribute to BNCT dosimetry, further analysis increasing the number of samples is warranted.


Assuntos
Autorradiografia/métodos , Boro/farmacocinética , Pulmão/metabolismo , Nêutrons , Animais , Terapia por Captura de Nêutron de Boro/métodos , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA