Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 117
Filtrar
1.
J Dent ; 142: 104875, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38309571

RESUMO

OBJECTIVE: The application of anti-inflammatories as topical desensitizers before dental bleaching is an approach to reduce bleaching-induced tooth sensitivity (TS). This randomized controlled trial compared the risk and intensity of TS and the color change resulting from in-office dental bleaching after using an experimental desensitizing gel containing ibuprofen and arginine. METHODS: Sixty-two participants with upper canine shades A2 or darker were randomly assigned to either the ibuprofen-arginine desensitizing group or the placebo group. The desensitizing gel was applied for 15 min before in-office bleaching with 35 % hydrogen peroxide gel for 50 min (2 sessions). To assess the absolute risk and intensity of TS, visual (0-10) and numeric rating (0-5) scales were used, and group comparisons were made using the McNemar test, Wilcoxon test, and paired Student t-test (α = 0.05). Color change was evaluated using Vita Classical, Vita Bleachedguide (ΔSGU), and Vita EasyShade (ΔEab, ΔE00, and ΔWID) before and one month after the bleaching procedure. Group comparisons for color change were done using a paired t-test (α = 0.05). RESULTS: The odds ratio for TS was 0.14 [95 % CI 0.02 to 0.6], meaning lower odds of TS for the desensitizing gel. A lower intensity of TS was also observed for the experimental group (p < 0.005) up to 48 h after bleaching. All color evaluation tools demonstrated effective and similar whitening for both groups (p > 0.05). CONCLUSIONS: Using the experimental desensitizing gel containing ibuprofen and arginine effectively reduced the risk and intensity of TS without compromising the bleaching efficacy. CLINICAL RELEVANCE: The topical application of ibuprofen/arginine on the in-office bleaching reduced risk and intensity of bleaching-induced tooth sensitivity.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Humanos , Sensibilidade da Dentina/induzido quimicamente , Sensibilidade da Dentina/prevenção & controle , Clareadores Dentários/efeitos adversos , Ibuprofeno/uso terapêutico , Clareamento Dental/efeitos adversos , Clareamento Dental/métodos , Peróxido de Hidrogênio/efeitos adversos , Compostos de Sódio , Arginina/uso terapêutico , Resultado do Tratamento
2.
Restor Dent Endod ; 48(3): e28, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37675450

RESUMO

Objectives: This study aimed to investigate the effect of the application method of 2% chlorhexidine (CHX) and its influence on the adhesion of fiberglass posts cemented with a self-adhesive resin cement. Materials and Methods: Sixty human mandibular premolars were endodontically treated and divided into 5 groups (n = 12), according to the canal irrigant and its application method: 2 groups with conventional syringe irrigation (CSI)-2.5% sodium hypochlorite (NaOCl) (control) and 2% CHX- and 3 groups with 2% CHX irrigation/activation-by passive ultrasonic irrigation (PUI), Easy Clean file, and XP-Endo Finisher file. Two roots per group were evaluated for smear layer (SL) removal by scanning electron microscopy. For other roots, fiber posts were luted using a self-adhesive resin cement. The roots were sectioned into 6 slices for push-out bond strength (BS) (7/group) and nanoleakage (NL) (3/group). Data from SL removal were submitted to Kruskal-Wallis and Student-Newman-Keuls tests (α = 0.05). Data from BS and NL were evaluated by 2-way analysis of variance and Tukey's test (α = 0.05). Results: For SL removal and BS, the CHX irrigation/activation promoted better values than CSI with CHX (p < 0.05), but it was not significantly different from CSI with NaOCl (p > 0.05). For NL, the lowest values were obtained by the chlorhexidine irrigation/activation groups (p < 0.05). Conclusions: Active 2% CHX irrigation can be used to improve the post space cleaning and adhesion before fiber post cementation with self-adhesive resin cements.

3.
Braz Oral Res ; 37: e42, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37132729

RESUMO

The purpose of this study was to evaluate the effect of dentin moisture (moist and dry) on the bonding of fiber posts to root dentin with different adhesive strategies (etch-and-rinse, self-etch, and self-adhesive). Seventy-two extracted single-rooted human teeth were endodontically treated and divided into six groups (n = 12) according to the moisture of dentin surface and adhesive systems as follows: a) etch-and-rinse/moist, b) etch-and-rinse/dry, c) self-etch/moist, d) self-etch/dry, e) self-adhesive/moist, and 6) self-adhesive/dry. The specimens were sectioned into six slices for push-out bond strength (BS), nanoleakage (NL) by SEM, and Vickers microhardness (VHN) of the resin cement. A universal testing machine (AG-I, Shimadzu Autograph) was used at a crosshead speed of 0.5 mm/min until post extrusion, with a load cell of 50 kg for evaluation of the push-out strength. Data on BS, NL, and VHN were evaluated by two-way ANOVA and Tukey's test (α = 0.05). Dentin moisture as the main factor was not significantly different for the push-out test. However, higher BS values can be observed for the etch-and-rinse group. A lower percentage of NL was found in the dry dentin groups. The moisture pattern was not significant in the hardness values for the pre-etching groups. Additional moisture did not increase the evaluated properties.


Assuntos
Colagem Dentária , Cimentos de Resina , Humanos , Cimentos Dentários , Teste de Materiais , Dentina , Adesivos Dentinários/química
4.
Braz. oral res. (Online) ; 37: e42, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1430032

RESUMO

Abstract The purpose of this study was to evaluate the effect of dentin moisture (moist and dry) on the bonding of fiber posts to root dentin with different adhesive strategies (etch-and-rinse, self-etch, and self-adhesive). Seventy-two extracted single-rooted human teeth were endodontically treated and divided into six groups (n = 12) according to the moisture of dentin surface and adhesive systems as follows: a) etch-and-rinse/moist, b) etch-and-rinse/dry, c) self-etch/moist, d) self-etch/dry, e) self-adhesive/moist, and 6) self-adhesive/dry. The specimens were sectioned into six slices for push-out bond strength (BS), nanoleakage (NL) by SEM, and Vickers microhardness (VHN) of the resin cement. A universal testing machine (AG-I, Shimadzu Autograph) was used at a crosshead speed of 0.5 mm/min until post extrusion, with a load cell of 50 kg for evaluation of the push-out strength. Data on BS, NL, and VHN were evaluated by two-way ANOVA and Tukey's test (α = 0.05). Dentin moisture as the main factor was not significantly different for the push-out test. However, higher BS values can be observed for the etch-and-rinse group. A lower percentage of NL was found in the dry dentin groups. The moisture pattern was not significant in the hardness values for the pre-etching groups. Additional moisture did not increase the evaluated properties.

5.
Braz. oral res. (Online) ; 35: e012, 2021. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1132751

RESUMO

Abstract The purpose of this study was to analyze the effect of the application of different concentrations of EDTA on the adhesion of fiber posts to root dentin using self-adhesive resin cements. After endodontic treatment, 78 single roots were randomly divided into six groups (n = 13) according to the combination of the following factors: surface dentin treatment - control (distilled water), 17% EDTA and 24% EDTA; and self-adhesive resin cement - RelyX U200 (RX); and Multilink Speed (ML). After fiber post cementation, six slices were obtained for each root. Ten roots of each group were used for bond strength (BS) and three for microhardness (MH) evaluations. Data obtained from BS and MH tests for each resin cement were subjected to two-way ANOVA (surface treatment vs. root region) and to a post-hoc Tukey's test (α = 0.05). The lowest BS value was observed in the 24% EDTA group for RX cement, whereas the highest values for ML cement were observed for the control group in the middle and apical regions. In the MH test, the lowest value for RX was observed for 24% EDTA in the cervical region, whereas and the highest value for the ML cement was observed in the control group. Regarding both self-adhesive resin cements tested, the application of 24% EDTA was not able to improve the adhesion of fiber posts to root canal.


Assuntos
Cimentos de Resina , Teste de Materiais , Técnica para Retentor Intrarradicular , Ácido Edético/farmacologia , Cavidade Pulpar , Dentina , Vidro
6.
Braz Oral Res ; 35: e012, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33237242

RESUMO

The purpose of this study was to analyze the effect of the application of different concentrations of EDTA on the adhesion of fiber posts to root dentin using self-adhesive resin cements. After endodontic treatment, 78 single roots were randomly divided into six groups (n = 13) according to the combination of the following factors: surface dentin treatment - control (distilled water), 17% EDTA and 24% EDTA; and self-adhesive resin cement - RelyX U200 (RX); and Multilink Speed (ML). After fiber post cementation, six slices were obtained for each root. Ten roots of each group were used for bond strength (BS) and three for microhardness (MH) evaluations. Data obtained from BS and MH tests for each resin cement were subjected to two-way ANOVA (surface treatment vs. root region) and to a post-hoc Tukey's test (α = 0.05). The lowest BS value was observed in the 24% EDTA group for RX cement, whereas the highest values for ML cement were observed for the control group in the middle and apical regions. In the MH test, the lowest value for RX was observed for 24% EDTA in the cervical region, whereas and the highest value for the ML cement was observed in the control group. Regarding both self-adhesive resin cements tested, the application of 24% EDTA was not able to improve the adhesion of fiber posts to root canal.


Assuntos
Cimentos de Resina , Cavidade Pulpar , Dentina , Ácido Edético/farmacologia , Vidro , Teste de Materiais , Técnica para Retentor Intrarradicular
7.
BMC Emerg Med ; 20(1): 47, 2020 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-32527325

RESUMO

BACKGROUND: The average age of the global population is rising at an increasing rate. There is a disproportional increase in Emergency Department (ED) visits by older people worldwide. In the Brazilian health system, complex and severely ill patients and those requiring specialized urgent procedures are referred to tertiary level care. As far as we know, no other study in Latin America has analyzed the impact of demographic changes in tertiary ED attendance. AIM: To describe the sociodemographic characteristics and outcomes of tertiary Brazilian ED users. METHODS: Design: Observational cross-sectional analytic study. SETTING: Emergency Department, tertiary university hospital, São Paulo, Brazil. PARTICIPANTS: patients aged 18 years or older attending a tertiary ED (2009-2013). The primary outcomes were hospitalization and mortality; the secondary outcome was ICU admission. Age was categorized as 'young adults' (18-39y), 'adults' (40-59y), 'young-older adults' (60-79y), and 'old-older adults' (80-109y). Other variables included sex, reason for attendance, time of ED visit, mode of presentation, type of hospitalization, main procedure, length of hospital stay (LOS) and length of ICU stay (ICU-LOS). We calculated descriptive statistics, built generalized linear mixed models for each outcome and estimated Odds Ratios (95% CI) for the independent categorical variables. The significance level was 5% with Bonferroni correction. RESULTS: Older age-groups represented 26.6% of 333,028 ED visits, 40.7% of admissions, 42.7% of ICU admissions and 58% of all deaths. Old-older patients accounted for 5.1% of ED visits, 9.5% of admissions and 10.1% of ICU admissions. Hospitalization, ICU admission and mortality rates increased with older age in both sexes. LOS and ICU-LOS were similar across age-groups. The proportions of visits and admissions attributed to young adults decreased annually, while those of people aged 60 or over increased. The ORs for hospitalization, ICU admission and mortality associated with the old-older group were 3.49 (95% CI = 3.15-3.87), 1.27 (1.15-1.39) and 5.93 (5.29-6.66) respectively, with young adults as the reference. CONCLUSIONS: In tertiary ED, age is an important risk factor for hospitalization and mortality, but not for ICU admission. Old-older people are at the greatest risk and demand further subgroup stratification.


Assuntos
Serviço Hospitalar de Emergência/estatística & dados numéricos , Mortalidade Hospitalar , Hospitalização/estatística & dados numéricos , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Brasil , Estudos Transversais , Feminino , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
8.
Clin Oral Investig ; 24(2): 809-822, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31190231

RESUMO

OBJECTIVES: The aim of this study was to investigate the effects of collagen cross-linking agents on nanomechanical and bonding properties of eroded dentin (ED), 24 h and 2 years after water storage. MATERIALS AND METHODS: Human molar dentin surfaces, eroded by soft drinks or citric acid, were acid-etched and treated with primers containing proanthocyanidin (PA) and riboflavin (RI) or were untreated (control) and tested after 24 h and 2 years. After acid etching and adhesive application (Prime&Bond Elect (PBE); Scotchbond Universal (SBU); Tetric n-bond Universal (TEU)), specimens were sectioned into beams and tested for microtensile bond strength (µTBS) and silver nitrate deposition (NL) after 24 h and 2 years. The beams were used to evaluate the 24-h in situ conversion of degree (DC). Nanohardness (NH) and Young's modulus (YM) were evaluated via resin-bonded dentin slices after 24 h and 2 years. A three-way ANOVA and Tukey's test were used for statistical analysis (5%). RESULTS: For both storage times, ED with citric acid resulted in lower µTBS, NH, and YM and higher NL for each adhesive system than soft drink ED (p < 0.05). After 2 years of water storage, cross-linking primers maintained the µTBS, NH, and YM (p < 0.05) when compared with the control group. Althougth, the NL values decreased for all groups after 2 years of water storage, PA and RI treatments showed NI values lower than control group (p < 0.001). No significant differences were observed between PA and RI treatments (p > 0.05). Cross-linking primers maintain or improve DC (p < 0.03). In general, TEU and SBU yielded higher µTBS, DC, NH, and YM and lower NL than PBE. CONCLUSION: Cross-linking agents improved the results and maintained the resin-ED interface bonding and nanomechanical properties, without jeopardizing adhesive polymerization. CLINICAL RELEVANCE: Cross-linking agents are a viable alternative for improving and maintaining resin-ED interface bonding and nanomechanical properties.


Assuntos
Colagem Dentária , Colágeno , Resinas Compostas , Dentina , Adesivos Dentinários , Humanos , Teste de Materiais , Cimentos de Resina , Resistência à Tração , Água
9.
Braz Dent J ; 30(2): 171-178, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30970061

RESUMO

To evaluate the effect of combining 5% hydrofluoric acid (HF) and silane (SI) with the self-etching ceramic primer on the immediate and after 1-year of water storage on bonding efficacy, conditioning pattern (CP) and chemical interaction (CI) to the lithium disilicate. A total of 16 CAD/CAM blocks of lithium disilicate (LD) were cut into four square sections (n=64). For bonding efficacy evaluation, the LD specimens were divided into 4 groups (n=10): 1) HF+SI; 2) self-etching ceramic primer (MEP); 3) HF+MEP; 4) MEP+SI. After each treatment, an adhesive system was applied and Tygon matrices were filled with a dual-cured resin cement followed by light curing. Cylinder specimens (0.8 mmx0.5mm) were stored in water (37 °C for 24 h or 1-year) and submitted to the µSBS test (2-way ANOVA and Tukey's test; a=0.05). CP and CI were only evaluated qualitatively. No significant difference on the µSBS was observed between groups (p=0.73), but reduced µSBS was observed after 1-year of water storage (p>0.0001). After application of HF+SI and MEP, reduction in a number of siloxane bonds was observed, suggesting the coupling of SI on the LD surface. HF or HF+MEP produced a higher dissolution of the glassy matrix than the use of MEP alone. The MEP can be an alternative to traditional ceramic treatment once the chemical interaction and long-term bond strength were similar between both groups. The association of hydrofluoric acid or silane with a self-etching ceramic primer did not add any benefits in terms of chemical interaction and bonding stability.


Assuntos
Colagem Dentária , Ácido Fluorídrico , Cerâmica , Porcelana Dentária , Análise do Estresse Dentário , Teste de Materiais , Cimentos de Resina , Silanos , Propriedades de Superfície
10.
Braz Dent J ; 30(1): 58-65, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30864649

RESUMO

The aim of this study was to evaluate different conditioning protocols and sonic/ultrasonic application of an infiltrant resin (IR) in artificial white spot lesions (AWSL). the V/L surfaces of 48 molars were induced to an AWSL and divided in 6 groups, according to the conditioning protocols and application technique: 15% hydrochloric acid (HA) + manual application of the IR; HA + 37% phosphoric acid (PA) + manual application of the IR; HA + ultrasonic application (U) of the IR; HA + sonic application (S) of the IR; PA+HA+S; and PA+HA+U. For the Penetration Depth (PD), the crowns were etched with HA for 120s. The IR Icon® (DMG) was applied according to the manufacturer`s instructions. The crowns were dye penetrated (0.1% red fluorophore rhodamine B isothiocyanate for 12h) and bleached with 30% hydrogen peroxide for 12 h. The discs were immersed in a 50% ethanol solution, containing 100 µM of sodium fluorescein. The PD (in µm) was measured using confocal laser scanning microscopy (20x). The bond strength (BS) was performed by michoshear test (0.5 mm/min). Data were submitted to 2-way ANOVA and Tukey (α=0.05). For BS, the interaction was not significant (p>0.05). For PD, the main factors were significant (application - p<0.001; conditioning technique - p=0.003). The ultrasonic application showed the highest PD values. PA+HA presented higher results than HA. The sonic/ultrasonic applications and the use of phosphoric acid prior to hydrochloric acid improved PD of the infiltrant resin. Conditioning protocols or application techniques did not influence BS values.


Assuntos
Cor , Resinas Compostas/química , Esmalte Dentário , Estética Dentária , Rodaminas/química , Ondas Ultrassônicas , Humanos , Microscopia Confocal
11.
Braz. dent. j ; Braz. dent. j;30(2): 171-178, Mar.-Apr. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1001436

RESUMO

Abstract To evaluate the effect of combining 5% hydrofluoric acid (HF) and silane (SI) with the self-etching ceramic primer on the immediate and after 1-year of water storage on bonding efficacy, conditioning pattern (CP) and chemical interaction (CI) to the lithium disilicate. A total of 16 CAD/CAM blocks of lithium disilicate (LD) were cut into four square sections (n=64). For bonding efficacy evaluation, the LD specimens were divided into 4 groups (n=10): 1) HF+SI; 2) self-etching ceramic primer (MEP); 3) HF+MEP; 4) MEP+SI. After each treatment, an adhesive system was applied and Tygon matrices were filled with a dual-cured resin cement followed by light curing. Cylinder specimens (0.8 mmx0.5mm) were stored in water (37 °C for 24 h or 1-year) and submitted to the μSBS test (2-way ANOVA and Tukey's test; a=0.05). CP and CI were only evaluated qualitatively. No significant difference on the μSBS was observed between groups (p=0.73), but reduced μSBS was observed after 1-year of water storage (p>0.0001). After application of HF+SI and MEP, reduction in a number of siloxane bonds was observed, suggesting the coupling of SI on the LD surface. HF or HF+MEP produced a higher dissolution of the glassy matrix than the use of MEP alone. The MEP can be an alternative to traditional ceramic treatment once the chemical interaction and long-term bond strength were similar between both groups. The association of hydrofluoric acid or silane with a self-etching ceramic primer did not add any benefits in terms of chemical interaction and bonding stability.


Resumo Avaliar o efeito da combinação de ácido fluorídrico ou silano com o primer autocondicionante de cerâmicas sobre a eficácia da união imediata e após 1 ano de armazenamento em água, padrão de condicionamento e interação química desses tratamentos com o dissilicato de lítio. Um total de 16 blocos CAD/CAM de dissilicato de lítio (DL) foram cortados em quatro seções quadradas (n=64). Os espécimes de DL foram divididos em 4 grupos: 1) ácido fluorídrico a 5% + silano (HF + SI); 2) primer autocondicionante de cerâmica (MEP); 3) HF + MEP; 4) MPE + SI. Após cada tratamento, o sistema adesivo foi aplicado e as matrizes Tygon foram preenchidas com cimento resinoso dual (Variolink® II), seguido de fotopolimerização. Espécimes em forma de cilindro (0.8 mmÆ x 0.5 mm), foram armazenados em água (37 °C por 24h ou 1 ano) e submetidos ao teste μSBS (ANOVA dois fatores e teste de Tukey; a=0,05). Para avaliação das interações químicas por Espectroscopia Raman, os espécimes de DL foram divididos em 3 grupos (n=4): 1) sem tratamento (DL); 2) HF + SI; e 3) MEP. Para avaliação do padrão de condicionamento da superfície cerâmica após os tratamentos por MEV, os espécimes de DL foram divididos em 3 grupos (n=3): 1) DL; 2) HF; 3) MEP; e 4) HF + MEP. Ambos os métodos foram avaliados apenas qualitativamente. Não foi observada diferença significativa na μSBS imediata entre os grupos (p=0,73), mas após 1 ano de armazenamento das amostras em água, reduziu μSBS (p>0,0001). HF ou HF + MEP produziram uma maior dissolução da matriz vítrea do que o uso de MEP sozinho. Após a aplicação de SI e MEP, observou-se redução de ligações de siloxano, sugerindo o acoplamento da camada de silano na superfície do DL. O primer autocondicionante cerâmico pode ser uma alternativa ao tratamento cerâmico tradicional, uma vez que a interação química e a resistência de união a longo prazo, quando comparada ao tratamento tradicional foram estatisticamente semelhantes. A associação de ácido fluorídrico ou agente de acoplamento silano com um primer autocondicionante de cerâmicas não agregou nenhum benefício em termos de interação química e estabilidade.


Assuntos
Colagem Dentária , Ácido Fluorídrico , Silanos , Propriedades de Superfície , Teste de Materiais , Cerâmica , Cimentos de Resina , Porcelana Dentária , Análise do Estresse Dentário
12.
Braz. dent. j ; Braz. dent. j;30(1): 58-65, Jan.-Feb. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-989434

RESUMO

Abstract The aim of this study was to evaluate different conditioning protocols and sonic/ultrasonic application of an infiltrant resin (IR) in artificial white spot lesions (AWSL). the V/L surfaces of 48 molars were induced to an AWSL and divided in 6 groups, according to the conditioning protocols and application technique: 15% hydrochloric acid (HA) + manual application of the IR; HA + 37% phosphoric acid (PA) + manual application of the IR; HA + ultrasonic application (U) of the IR; HA + sonic application (S) of the IR; PA+HA+S; and PA+HA+U. For the Penetration Depth (PD), the crowns were etched with HA for 120s. The IR Icon® (DMG) was applied according to the manufacturer`s instructions. The crowns were dye penetrated (0.1% red fluorophore rhodamine B isothiocyanate for 12h) and bleached with 30% hydrogen peroxide for 12 h. The discs were immersed in a 50% ethanol solution, containing 100 µM of sodium fluorescein. The PD (in µm) was measured using confocal laser scanning microscopy (20x). The bond strength (BS) was performed by michoshear test (0.5 mm/min). Data were submitted to 2-way ANOVA and Tukey (α=0.05). For BS, the interaction was not significant (p>0.05). For PD, the main factors were significant (application - p<0.001; conditioning technique - p=0.003). The ultrasonic application showed the highest PD values. PA+HA presented higher results than HA. The sonic/ultrasonic applications and the use of phosphoric acid prior to hydrochloric acid improved PD of the infiltrant resin. Conditioning protocols or application techniques did not influence BS values.


Resumo: O objetivo deste estudo foi avaliar diferentes protocolos de condicionamento e a aplicação sônica/ultrassônica de uma resina infiltrante (RI) em lesões de mancha branca produzidas artificialmente (LMBA). As superfícies vestibulares/linguais de 48 molares foram induzidas à formação de LMBA e divididas em 6 grupos, de acordo com os protocolos de condicionamento e técnica de aplicação da resina infiltrante: ácido hidroclorídrico 15% (AH) + aplicação manual da RI; AH + ácido fosfórico 37% (AF) + aplicação manual da RI; AH + aplicação ultrassônica da RI (U); AH + aplicação sônica da RI (S); AF + AH + S; e AF + AH + U. para o grau de penetração (GP), condicionou-se as coroas com AH por 120 s. A RI Icon® (DMG) foi aplicada de acordo com as instruções do fabricante. As coroas foram coradas (rodamina B 0,1% por 12 h) e clareadas com peróxido de hidrogênio 30% por 12 h. os discos foram imersos em solução de etanol 50%, contendo 100 µM de fluoresceína sódica. O GP (em µm) foi mensurado por meio de microscopia confocal a laser (20´). A resistência de união (RU) foi calculada pelo teste de microcisalhamento (0,5 mm/min). Os dados foram submetidos ao teste ANOVA 2 fatores e Tukey (α=0,05). Para RU, a interação não foi significante (p>0,05). Para GP, os fatores principais foram significantes (técnica de aplicação - p<0,001; protocolos de condicionamento - p=0,003). A aplicação U mostrou os maiores valores de GP. AF+AH demonstrou resultados superiores ao grupo AH. As aplicações sônica/ultrassônica e o uso do ácido fosfórico antes do ácido hidroclorídrico aumentaram o GP da resina infiltrante. Os protocolos de condicionamento ou as técnicas de aplicação não influenciaram os valores de RU.


Assuntos
Humanos , Rodaminas/química , Cor , Resinas Compostas/química , Esmalte Dentário , Estética Dentária , Ondas Ultrassônicas , Microscopia Confocal
13.
Braz. j. oral sci ; 17: e181358, 2018. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-970422

RESUMO

Aim: The objective is to evaluate the influence of different burs used to prepare the root canal space and acid ultrasonic agitation on bond strength (BS) between glass fiber posts (GFP) and root dentin. Methods: After endodontic treatment, the root canal spaces of 36 extracted human canines were prepared, according to the rotary instrument used (n=18): carbide bur (CB), provided by the post manufacturer and a diamond bur (DB). In both groups, the fiber posts were cemented with the adhesive system Ambar and resin cement Allcem, following the manufacturer`s instructions. Previously to the cementation procedures, the groups were subdivided into 2 groups (n=9), according to the phosphoric acid application mode: conventional etching (CE) and active etching (AE), performed by ultrasonic tip, both for 15s. Before the cementation procedures and after the acid application, 1 root of each group was randomly selected for ultrastructural morphological evaluation by SEM. After 1 week of the cementation, 8 specimens per group were transversely sectioned into six 1-mm thick slices, the root canal regions (cervical, medium and apical) were identified and the push-out test was performed to evaluate BS. Data were analyzed by 3-way ANOVA and Tukey test (α=0.05). Results: The results showed that the cross-product interaction of all factors was significant (P=0.035). Higher bond strength values were obtained when a DB with conventional etching, instead of CB, was used to prepare the root post space. Conclusion: It may be concluded that the use of diamond burs with conventional etching yields high BS values in all root canal thirds


Assuntos
Humanos , Masculino , Feminino , Técnica para Retentor Intrarradicular , Cimentação , Cimentos de Resina
14.
Braz Dent J ; 28(6): 744-748, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29211132

RESUMO

To examine the effect of the alternative coinitiator 4,4'bis dimethylamino benzydrol (BZN) in degree of conversion (DC), mechanical and biological properties of experimental composites. The coinitiator BZN was used in three concentrations (0.2, 0.5 and 1.2%), and the coinitiator DMAEMA was used as control at the same concentrations as above. The molar concentration of camphorquinone (CQ) and coinitiators was kept constant (1:1). The composites were manipulated and submitted to microhardness test (VHN), flexural and compressive strength (in MPa), elastic modulus (GPa), DC (FT-IR) and in vitro cytotoxicity (against 3T3 fibroblastic cells) of the experimental resins. Data were subjected to two-way ANOVA and Tukey post-test (α=0.05). The experimental composite resin with BZN showed higher DC values compared to control DMAEMA groups. For the mechanical properties, microhardness values were higher in BZN groups; flexural strength and elastic modulus were similar between all the groups. Compressive strength for groups BZN0.5 and DMAEMA0.5 were not statistically different, being the lowest values attributed to group BZN0.2. The experimental resins with BZN and DMAEMA were considered nontoxic against 3T3 fibroblasts. The inclusion of the coinitiator BZN in experimental composites was considered nontoxic against 3T3 fibroblast cells, without compromising DC and mechanical properties.


Assuntos
Aminas/química , Resinas Compostas , Teste de Materiais , Células 3T3 , Animais , Camundongos
15.
Braz. dent. j ; Braz. dent. j;28(6): 744-748, Nov.-Dec. 2017. tab
Artigo em Inglês | LILACS | ID: biblio-888705

RESUMO

Abstract To examine the effect of the alternative coinitiator 4,4'bis dimethylamino benzydrol (BZN) in degree of conversion (DC), mechanical and biological properties of experimental composites. The coinitiator BZN was used in three concentrations (0.2, 0.5 and 1.2%), and the coinitiator DMAEMA was used as control at the same concentrations as above. The molar concentration of camphorquinone (CQ) and coinitiators was kept constant (1:1). The composites were manipulated and submitted to microhardness test (VHN), flexural and compressive strength (in MPa), elastic modulus (GPa), DC (FT-IR) and in vitro cytotoxicity (against 3T3 fibroblastic cells) of the experimental resins. Data were subjected to two-way ANOVA and Tukey post-test (α=0.05). The experimental composite resin with BZN showed higher DC values compared to control DMAEMA groups. For the mechanical properties, microhardness values were higher in BZN groups; flexural strength and elastic modulus were similar between all the groups. Compressive strength for groups BZN0.5 and DMAEMA0.5 were not statistically different, being the lowest values attributed to group BZN0.2. The experimental resins with BZN and DMAEMA were considered nontoxic against 3T3 fibroblasts. The inclusion of the coinitiator BZN in experimental composites was considered nontoxic against 3T3 fibroblast cells, without compromising DC and mechanical properties.


Resumo Analisar o efeito do co-iniciador alternativo 4,4'bisdimetilaminobenzidrol (BZN) no grau de conversão (GC) e nas propriedades mecânicas e biológicas de resinas compostas experimentais. O co-iniciador BZN foi utilizado em três concentrações (0,2, 0,5 e 1,2), e o co-iniciador DMAEMA como controle, nas mesmas concentrações acima. A concentração molar entre canforoquinona (CQ) e os co-iniciadores foi mantida constante (1:1). As resinas compostas foram manipuladas e submetidas aos testes de microdureza (VHN), resistência à compressão e flexural (em MPa), módulo de elasticidade (em GPa), GC (em %, por meio de espectroscopia micro-Raman e FTIR com KBr), citotoxicidade in vitro (frente às células fibroblásticas 3T3) das resinas experimentais. Os resultados foram submetidos ao teste ANOVA 1 fator e pós-teste de Tukey (α=0,05). As resinas compostas experimentais com o BZN apresentaram GC e propriedades mecânicas satisfatórias, além de serem consideradas atóxicas a fibroblastos 3T3. A inclusão do co-iniciador BZN à resina composta foi considerada não tóxica frente a células fibroblásticas 3T3 e sem comprometer o grau de conversão e as propriedades mecânicas da mesma.


Assuntos
Animais , Camundongos , Aminas/química , Resinas Compostas , Teste de Materiais , Células 3T3
16.
J Appl Oral Sci ; 25(1): 2-9, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28198970

RESUMO

OBJECTIVES: To evaluate the influence of two curing techniques on the degree of conversion (DC) of resin cements and on bond strength (BS) of fiber posts in different regions of root dentin. MATERIAL AND METHODS: Twenty single-rooted premolars were endodontically treated, and the post spaces were prepared. The roots were randomly divided into two groups (n=10), according to the activation mode of the resin cement RelyX™ U200 (3M ESPE Saint Paul, MN, USA): conventional (continuous activation mode) and soft-start activation mode (Ramp). The posts (WhitePost DC/FGM) were cemented according to the manufacturer's recommendations and, after one week, the roots were cross-sectioned into six discs each of 1-mm thickness, and the cervical, medium, and apical thirds of the root canals were identified. The DC was evaluated under micro-Raman spectroscopy and the BS was evaluated by the push-out test. The data were analyzed by two-way ANOVA and Tukey's test (α=0.05). RESULTS: Neither the activation mode nor the root regions affected the DC of the resin cement. Higher BS was achieved in the soft-start group (p=0.036); lower BS was observed in the apical third compared to the other root regions (p<0.001). Irrespective of the activation mode and root region, the mixed failure mode was the most prevalent. CONCLUSION: The BS of fiber posts to root canals can be improved by soft-started polymerization. The DC was not affected by the curing mode.


Assuntos
Cavidade Pulpar/efeitos dos fármacos , Técnica para Retentor Intrarradicular , Cimentos de Resina/química , Autocura de Resinas Dentárias/métodos , Análise de Variância , Lâmpadas de Polimerização Dentária , Falha de Restauração Dentária , Análise do Estresse Dentário , Dentina/efeitos dos fármacos , Humanos , Teste de Materiais , Processos Fotoquímicos , Distribuição Aleatória , Reprodutibilidade dos Testes , Tratamento do Canal Radicular/métodos , Resistência ao Cisalhamento , Análise Espectral Raman , Estatísticas não Paramétricas , Dente não Vital
17.
J. appl. oral sci ; J. appl. oral sci;25(1): 2-9, Jan.-Feb. 2017. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-841167

RESUMO

Abstract Objectives To evaluate the influence of two curing techniques on the degree of conversion (DC) of resin cements and on bond strength (BS) of fiber posts in different regions of root dentin. Material and Methods Twenty single-rooted premolars were endodontically treated, and the post spaces were prepared. The roots were randomly divided into two groups (n=10), according to the activation mode of the resin cement RelyX™ U200 (3M ESPE Saint Paul, MN, USA): conventional (continuous activation mode) and soft-start activation mode (Ramp). The posts (WhitePost DC/FGM) were cemented according to the manufacturer’s recommendations and, after one week, the roots were cross-sectioned into six discs each of 1-mm thickness, and the cervical, medium, and apical thirds of the root canals were identified. The DC was evaluated under micro-Raman spectroscopy and the BS was evaluated by the push-out test. The data were analyzed by two-way ANOVA and Tukey’s test (α=0.05). Results Neither the activation mode nor the root regions affected the DC of the resin cement. Higher BS was achieved in the soft-start group (p=0.036); lower BS was observed in the apical third compared to the other root regions (p<0.001). Irrespective of the activation mode and root region, the mixed failure mode was the most prevalent. Conclusion The BS of fiber posts to root canals can be improved by soft-started polymerization. The DC was not affected by the curing mode.


Assuntos
Humanos , Técnica para Retentor Intrarradicular , Cimentos de Resina/química , Cavidade Pulpar/efeitos dos fármacos , Autocura de Resinas Dentárias/métodos , Tratamento do Canal Radicular/métodos , Análise Espectral Raman , Teste de Materiais , Distribuição Aleatória , Reprodutibilidade dos Testes , Análise de Variância , Estatísticas não Paramétricas , Dente não Vital , Falha de Restauração Dentária , Resistência ao Cisalhamento , Análise do Estresse Dentário , Dentina/efeitos dos fármacos , Lâmpadas de Polimerização Dentária , Processos Fotoquímicos
18.
Braz. j. oral sci ; 14(4): 262-266, Oct.-Dec. 2015. ilus, tab
Artigo em Inglês | LILACS | ID: lil-778241

RESUMO

To evaluate the effect of different in-office bleaching agents on the permeability, roughness and surface microhardness of human enamel. Methods: For evaluation of roughness and microhardness, 40 hemi-faces of 20 premolars were subjected to initial roughness (Ra parameter) and microhardness (VHN) measurements. Thirty-two premolar's crowns were used for permeability test. Then, all specimens were randomly divided into four groups: C - without bleaching (control), HP35 - bleaching with 35% hydrogen peroxide (HP), HPF38 - 38% HP+fluoride, HPC35 - 35% HP+calcium. Final roughness (FR) and microhardness (FM) measurements were evaluated. For permeability, the 32 crowns were immersed in 1% sodium hypochlorite (20 min) and silver nitrate solutions (2 h) and subjected to developing solution under fluorescent light (16 h). Three sections from the crowns were analyzed in light microscope (100x) to evaluate the scores of permeability: Score 0 - no tracer agent penetration; Score 1 - less than half the thickness of enamel penetration; Score 2 - tracer agent reaching half the enamel thickness; Score 3 - entire enamel depth penetration, without reaching dentin and Score 4 - tracer agent reaching dentin. For roughness and microhardness evaluation were used one-way ANOVA and Dunnet post-test for independent samples, and t test for paired samples. For permeability, the data were analyzed by Kruskal Wallis and Dunn tests. Results: A significantly higher permeability and surface roughness were observed in groups HP35, HPF38 and HPC35 compared to the C group, as well as decreased microhardness (p<0.05). Conclusions: All bleaching agents increased permeability and surface roughness, and decreased microhardness of human enamel; thus, the addition of fluoride or calcium was not beneficial...


Assuntos
Humanos , Masculino , Feminino , Clareadores Dentários/efeitos adversos , Esmalte Dentário , Permeabilidade do Esmalte Dentário , Peróxido de Hidrogênio/efeitos adversos , Peróxido de Hidrogênio/uso terapêutico , Propriedades de Superfície , Clareamento Dental
19.
Rev. odontol. UNESP (Online) ; 44(2): 80-84, Mar-Apr/2015. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-746234

RESUMO

Objetivo: Avaliar a liberação e a capacidade de recarga de flúor de diferentes cimentos de ionômero de vidro, durante a simulação de desafio cariogênico. Material e método: Foram confeccionados 12 corpos de prova para cada grupo experimental, com cimentos de ionômero de vidro convencionais - Maxxion R (FGM), Ketac Molar EasyMix (3M ESPE); cimento de ionômero de vidro modificado por resina - Vitrebond (3M ESPE), e resina composta, Filtek™ Z350XT (3M ESPE), como controle negativo. Os corpos de prova foram imersos alternadamente em sistema de ciclagem de pH, permanecendo 6 horas na solução de desmineralização e 18 horas na de remineralização, sendo mantidos em estufa a 37°C. Liberação de flúor foi verificada 1, 2, 7 e 14 dias antes e após a recarga com flúor, com eletrodo específico acoplado ao aparelho analisador de pH/fluoretos, calibrado a cada medição com soluções de fluoreto de sódio a 1 e 10 ppm, preparadas com TISAB II. Para leitura, foi adicionado 0,5 mL da amostra a igual volume de TISAB II. Recarga foi realizada com flúor neutro 2% por 4 minutos nas amostras, lavadas e imersas novamente nas soluções do sistema de ciclagem de pH. Os dados foram submetidos à análise de variância e ao teste de Tukey (α=0,05). Resultado: A liberação inicial de fluoreto (µgF/cm2) foi de 45,36; 37,49, e 26,35 para Maxxion R, Vitrebond e Ketac Molar EasyMix, respectivamente. Diferenças estatísticas significativas entre os materiais foram verificadas antes e após a recarga (p=0,001). Após a aplicação tópica de flúor, os cimentos de ionômero de vidro apresentaram capacidade de recarga de flúor. Conclusão: Cimentos de ionômero de vidro avaliados foram capazes de liberar flúor em soluções de ciclagem de pH e podem recarregar flúor através da aplicação tópica.


Objective: To evaluated the ability to fluoride release and recharge in the different glass ionomer cements during simulation of cariogenic challenge. Material and method: Twelve samples were made for each experimental group: conventional glass ionomer cements, Maxxion R (FGM), Ketac Molar EasyMix (3M ESPE); resin modified glass ionomer cement, Vitrebond (3M ESPE); and composite resin n Filtek™Z350XT (3M ESPE), negative control. The samples were immersed alternately in pH cycling method, remaining 6 hours in demineralization solution and 18 hours in remineralization solution and maintained at 37 °C. Fluoride release was measured 1, 2, 7, and 14 days before and after recharging with specific electrode coupled to the analyzer apparatus pH/fluoride, each measurement with calibrated solutions of sodium fluoride to 1 and 10 ppm, prepared with TISAB II. For reading was added 0.5 mL of sample to an equal volume of TISAB II. Recharging was made with neutral sodium fluoride to 2% for 4 minutes in the samples, washed and again immersed pH cycling solutions. Data were subjected to two-way ANOVA and Tukey's post-hoc test (α=0.05). Result: The initial fluoride release (µgF/cm2) was 45.36 ; 37.49 and 26.35 for Maxxion R, Vitrebond and Ketac Molar EasyMix, respectively. Significant differences between the materials before and after recharging were observed (p=0.001). After topical application of fluoride, both showed ability to recharge. Conclusion: The glass ionomer cements evaluated were capable of releasing fluoride in pH cycling solutions and may recharge through of a topical application.


Assuntos
Fluoreto de Sódio , Desmineralização , Análise de Variância , Resinas Compostas , Flúor , Cimentos de Ionômeros de Vidro , Concentração de Íons de Hidrogênio
20.
Dent Mater ; 31(5): 505-13, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25711700

RESUMO

OBJECTIVES: This in vivo study evaluated pulp temperature (PT) rise in human premolars during exposure to a light curing unit (LCU) using selected exposure modes (EMs). METHODS: After local Ethics Committee approval, intact first upper premolars, requiring extraction for orthodontic reasons, from 8 volunteers, received infiltrative and intraligamental anesthesia. The teeth (n=15) were isolated using rubber dam and a minute pulp exposure was attained. A sterile probe from a wireless, NIST-traceable, temperature acquisition system was inserted directly into the coronal pulp chamber, and real time PT (°C) was continuously monitored while the buccal surface was exposed to polywave light from a LED LCU (Bluephase 20i, Ivoclar Vivadent) using selected EMs allowing a 7-min span between each exposure: 10-s either in low (10-s/L) or high (10-s/H); 5-s-turbo (5-s/T); and 60-s-high (60-s/H) intensities. Peak PT values and PT increases from baseline (ΔT) after exposure were subjected to one-way, repeated measures ANOVAs, and Bonferroni's post hoc tests (α=0.05). Linear regression analysis was performed to establish the relationship between applied radiant exposure and ΔT. RESULTS: All EMs produced higher peak PT than the baseline temperature (p<0.001). The 60-s/H mode generated the highest peak PT and ΔT (p<0.001), with some teeth exhibiting ΔT higher than 5.5°C. A significant, positive relationship between applied radiant exposure and ΔT (r(2)=0.916; p<0.001) was noted. SIGNIFICANCE: Exposing intact, in vivo anesthetized human upper premolars to a polywave LED LCU increases PT, and depending on EM and the tooth, PT increase can be higher than the critical ΔT, thought to be associated with pulpal necrosis.


Assuntos
Temperatura Corporal/fisiologia , Lâmpadas de Polimerização Dentária , Polpa Dentária/fisiologia , Adolescente , Adulto , Anestesia Dentária , Dente Pré-Molar , Criança , Feminino , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA