Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Nucl Med Commun ; 45(8): 666-672, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38745501

RESUMO

BACKGROUND: In this substudy of the Value of Gated-SPECT MPI for Ischemia- Guided PCI of non-culprit vessels in STEMI Patients with Multi vessel Disease after primary PCI trial after primary PCI we aim to assess if infarct size affects conventional measures of dyssynchrony at rest. Additionally, we explore if there is an independent correlation of stress-inducible ischemia with dyssynchrony at rest. METHODS: The 48 patients with imaging at randomization were analyzed. Gated-single-photon emission computed tomography (SPECT) MPI with vasodilator stress and technetium-99m-labeled tracers was performed. The phase histogram bandwidth (HBW), phase SD, and entropy were obtained with the QGS software. Correlation between dyssynchrony at rest and infarct size and inducible ischemia was performed using the Spearman test. RESULTS: According to normal database limits dyssynchrony parameters at rest were abnormal for men. In women only HBW was abnormal. Correlation between the summed rest score with dyssynchrony was significant only for entropy ( P  = 0.035). No correlation was observed for dyssynchrony and stress-induced ischemia. CONCLUSION: Entropy, as a measure of dyssynchrony, has potential in the assessment of patients with STEMI and multivessel disease after primary PCI. Smaller residual myocardial scars in PCI-reperfused patients with STEMI may contribute to the lack of correlation between dyssynchrony at rest and infarct size and stress-induced ischemia, respectively.


Assuntos
Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Masculino , Feminino , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Pessoa de Meia-Idade , Idoso , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Intervenção Coronária Percutânea
2.
J Nucl Cardiol ; 29(3): 952-961, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33083983

RESUMO

BACKGROUND: Gated myocardial perfusion scintigraphy (GMPS) phase analysis is an important tool to investigate the physiology of left ventricular (LV) dyssynchrony. We aimed to test the performance of GMPS LV function and phase analysis in different clinical settings and on a diverse population. METHODS: This is a post hoc analysis of a prospective, non-randomized, multinational, multicenter cohort study. Clinical evaluation and GMPS prior to cardiac resynchronization therapy (CRT)(baseline) and 6-month post CRT (follow-up) were done. LV end-systolic volume (LVESV), LV end-diastolic volume (LVEDV), LV ejection fraction (LVEF), LV phase standard deviation (LVPSD), and percentage of left ventricle non-viable (PLVNV) were obtained by 10 centers and compared to the core lab. RESULTS: 276 GMPS studies had all data available from individual sites and from core lab. There were no statistically significant differences between all variables except for LVPSD. When subjects with no mechanical dyssynchrony were excluded, LVPSD difference became non-significant. LVESV, LVEF, LVPSD and PLVNV had strong correlation in site against core lab comparison. Bland-Altman plots demonstrated good agreement. CONCLUSIONS: The presented correlation and agreement of LV function and dyssynchrony analysis over different sites with a diverse sample corroborate the strength of GMPS in the management of heart failure in clinical practice.


Assuntos
Disfunção Ventricular Esquerda , Estudos de Coortes , Humanos , Perfusão , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Disfunção Ventricular Esquerda/diagnóstico por imagem
3.
J Nucl Cardiol ; 29(3): 1166-1174, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33152098

RESUMO

PURPOSE: We sought to evaluate the behavior of cardiac mechanical synchrony as measured by phase SD (PSD) derived from gated MPI SPECT (gSPECT) in patients with super-response after CRT and to evaluate the clinical and imaging characteristics associated with super-response. METHODS: 158 subjects were evaluated with gSPECT before and 6 months after CRT. Patients with an improvement of LVEF > 15% and NYHA class I/II or reduction in LV end-systolic volume > 30% and NYHA class I/II were labeled as super-responders (SR). RESULTS: 34 patients were classified as super-responders (22%) and had lower PSD (32° ± 17°) at 6 months after CRT compared to responders (45° ± 24°) and non-responders 46° ± 28° (P = .02 for both comparisons). Regression analysis identified predictors independently associated with super-response to CRT: absence of previous history of CAD (odds ratio 18.7; P = .002), absence of diabetes mellitus (odds ratio 13; P = .03), and history of hypertension (odds ratio .2; P = .01). CONCLUSION: LV dyssynchrony after CRT implantation, but not at baseline, was significantly better among super-responders compared to non-super-responders. The absence of diabetes, absence of CAD, and history of hypertension were independently associated with super-response after CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Hipertensão , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Hipertensão/complicações , Razão de Chances , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Resultado do Tratamento
5.
Int. j. cardiovasc. sci. (Impr.) ; 33(1): 87-93, Jan.-Feb. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1090637

RESUMO

Abstract 18-fluorine-fluorodeoxyglucose positron emission computed tomography (18F-FDG PET/CT) and singlephoton emission computed tomography (SPECT) using radiolabeled white blood cells (WBC) are non-invasive techniques widely used in the diagnosis of infections, like endocarditis. The aim of our paper was to provide a systematic review of the published data on the use of 18F-FDG PET/CT and SPECT in infective endocarditis (IE). A comprehensive literature search of the PubMed/ MEDLINE, Scopus, Embase and Cochrane library databases was conducted to find relevant published articles about the diagnostic performance of SPECT using WBC and 18F-FDG PET/CT in the diagnosis of infectious endocarditis. Twenty papers were included, with a total of 1,154 patients (166 studies with WBC SPECT and 988 with 18F-FDG PET/CT). From the analyses of the studies, the following results were obtained: both SPECT and PET/CT had good diagnostic accuracy in the study of endocarditis. 18F-FDG PET/CT had good specificity (85.8%) and lower sensitivity (68%), with high heterogeneity among the studies; WBC SPECT/ CT had an overall sensitivity of 80% and specificity of 98%. Specific preparations for PET/CT can affect the diagnostic accuracy of the test. Both 18F-FDG PET/CT and WBC SPECT are useful for the diagnosis of IE, and WBC SPECT appears to be slightly more specific than 18F-FDG PET/CT. A specific diet could influence the diagnostic performance of PET/CT.


Assuntos
Humanos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Endocardite/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Implante de Prótese de Valva Cardíaca , Leucócitos
7.
J Nucl Cardiol ; 21(6): 1168-76, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25213203

RESUMO

BACKGROUND: Transient post-ischemic LV dysfunction due to myocardial stunning in patients with coronary artery disease can be missed by conventional gated SPECT (GSPECT) acquisitions. The aim of this IAEA-sponsored multi-center study was to determine whether early post-exercise imaging is more likely to detect stunning than conventional without adversely affecting image quality or perfusion information. METHODS AND RESULTS: Patients undergoing exercise/rest GSPECT were enrolled in this international multicenter study. Post-exercise studies were acquired at 15 ± 5 minutes after radiotracer injection (Stress-1) and repeated at 60 ± 15 minutes (Stress-2). Rest studies (R) were acquired at 60 minutes post injection. A core laboratory quantitatively assessed perfusion pattern and LV blinded to the acquisition time. Ischemia was defined as summed stress score (SDS) ≥4, and stunning was defined as the difference between rest and post-stress LVEF (Δ-LVEF). In the 229 patients enrolled into the study, both image quality and perfusion information were similar between Stress-1 and Stress-2. Post-stress LVEF was associated with both ischemia and time of acquisition, with a significant correlation between SDS and Δ-LVEF, which was stronger at Stress-1 than Stress-2 in the ischemic compared to the non-ischemic population (r = 0.23 vs 0.08, P = 0.10). CONCLUSIONS: Early post-exercise imaging is feasible, and can potentially improve the detection of post-ischemic stunning without compromising image quality and perfusion data.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Teste de Esforço/métodos , Imagem de Perfusão do Miocárdio/métodos , Miocárdio Atordoado/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/complicações , Diagnóstico Precoce , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio Atordoado/etiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
J Nucl Cardiol ; 16(6): 956-61, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19649682

RESUMO

BACKGROUND: In 2005, 80% of cardiovascular disease (CVD) deaths occurred in low- to middle-income countries (i.e., developing nations). Cardiovascular imaging, such as myocardial perfusion SPECT, is one method that may be applied to detect and foster improved detection of at-risk patients. This document will review the availability and utilization for nuclear cardiology procedures worldwide and propose strategies to devise regional centers of excellence to achieve quality imaging around the world. METHODS: As a means to establish the current state of nuclear cardiology, International Atomic Energy Agency member and non-member states were queried as to annual utilization of nuclear cardiology procedures. Other sources for imaging statistics included data from medical societies (American Society of Nuclear Cardiology, European Society of Cardiology, and the European Association of Nuclear Medicine) and nuclear cardiology working groups within several nations. Utilization was calculated by dividing annual procedural volume by 2007 population statistics (/100,000) and categorized as high (>1,000/100,000), moderate-high (250-999/100,000), moderate (100-249/100,000), low-moderate (50-99/100,000) and low (<50/100,000). RESULTS: High nuclear cardiology utilization was reported in the United States, Canada, and Israel. Most Western European countries, Australia, and Japan reported moderate-high utilization. With the exception of Argentina, Brazil, Colombia and Uruguay, South America had low usage. This was also noted across Eastern Europe, Russia, and Asia. Utilization patterns generally mirrored each country's gross domestic product. However, nuclear cardiology utilization was higher for developing countries neighboring moderate-high "user" countries (e.g., Algeria and Egypt); perhaps the result of accessible high-quality training programs. CONCLUSIONS: Worldwide utilization patterns for nuclear cardiology vary substantially and may be influenced by physician access to training and education programs. Development of regional training centers of excellence can guide utilization of nuclear cardiology through the application of guideline- and appropriateness-driven testing, training, continuing education, and quality assurance programs aiding developing nations to confront the epidemics of CVD.


Assuntos
Cardiologia/estatística & dados numéricos , Diagnóstico por Imagem/estatística & dados numéricos , Acessibilidade aos Serviços de Saúde/estatística & dados numéricos , Avaliação das Necessidades , Medicina Nuclear/estatística & dados numéricos , Países Desenvolvidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA