1.
J Rehabil Res Dev ; 50(7): 1017-34, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24301438

RESUMO

To date, only one research study has evaluated how scooters respond to static and dynamic stability. However, no other studies have evaluated how scooters respond to adverse conditions and how they perform in all standard tests. A selection of 12 three-wheeled scooters was tested according to American National Standards Institute/Rehabilitation Engineering and Assistive Technology Society of North America (ANSI/ RESNA) wheelchair standards. Scooter models included the Victory, Gogo, Golden Companion (GC) I, and GC II. Victory and GC II were the most stable scooters. The Gogo scooters were the least dynamically stable. Five scooters (3 Gogo, 1 GC I, 1 GC II) failed the environmental condition tests. All GC I and II scooters failed parts of the power and control system tests. All scooters passed static and impact tests; however, all Gogo scooters and one GC II scooter had structural or motor failure during durability tests. The scooter models' survival life ranged from 62,512 to 1,178,230 cycles out of the 400,000 needed to pass the test. Tiller failures (typically tiller tube snapping) occurred with an average of 1,483 N force applied to the tiller structure. Our results indicate that these commercially available devices may not meet ANSI/RESNA standards. In addition, the tiller test should be conducted with scooters to further ensure their safety and durability and should use a test dummy with weight capacity according to the mobility device capacity.


Assuntos
Cadeiras de Rodas/normas , Fontes de Energia Elétrica/normas , Desenho de Equipamento/normas , Análise de Falha de Equipamento , Segurança de Equipamentos/normas , Humanos , Teste de Materiais , Tempo (Meteorologia)
2.
J Rehabil Res Dev ; 50(10): 1373-89, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24699973

RESUMO

Lightweight wheelchairs are characterized by their low cost and limited range of adjustment. Our study evaluated three different folding lightweight wheelchair models using the American National Standards Institute/Rehabilitation Engineering Society of North America (ANSI/RESNA) standards to see whether quality had improved since the previous data were reported. On the basis of reports of increasing breakdown rates in the community, we hypothesized that the quality of these wheelchairs had declined. Seven of the nine wheelchairs tested failed to pass the multidrum test durability requirements. An average of 194,502 +/- 172,668 equivalent cycles was completed, which is similar to the previous test results and far below the 400,000 minimum required to pass the ANSI/RESNA requirements. This was also significantly worse than the test results for aluminum ultralight folding wheelchairs. Overall, our results uncovered some disturbing issues with these wheelchairs and suggest that manufacturers should put more effort into this category to improve quality. To improve the durability of lightweight wheelchairs, we suggested that stronger regulations be developed that require wheelchairs to be tested by independent and certified test laboratories. We also proposed a wheelchair rating system based on the National Highway Transportation Safety Administration vehicle crash ratings to assist clinicians and end users when comparing the durability of different wheelchairs.


Assuntos
Análise de Falha de Equipamento , Cadeiras de Rodas/normas , Desenho de Equipamento , Humanos