RESUMO
OBJECTIVES: Although ultra-short pulsed laser (USPL) microstructuring has previously improved zirconia bond-strength, it is yet unclear how different laser-machined surface microstructures and patterns may influence the material's mechanical properties. Therefore, the aim of this study was to assess the flexural strength of zirconia after different USPL settings creating three different geometrical patterns with structures in micrometer scale. METHODS: One hundred sixty zirconia bars (3Y-TZP, 21 × 4 × 2.1 mm) were prepared and randomly divided into five groups (n = 32): no surface treatment (negative control-NC); sandblasting with Al2O3 (SB); and three laser groups irradiated with USPL (Nd:YVO4/1064 nm/2-34 J/cm2/12 ps): crossed-lines (LC), random-hatching (LR), and parallel-waves (LW). Bars were subjected to a four-point flexural test (1 mm/min) and crystal phase content changes were identified by X-ray diffraction. Surface roughness and topography were analyzed through 3D-laser-profilometry and SEM. Data were analyzed with parametric tests for roughness and Weibull for flexural strength (α = 5%). RESULTS: LR (Mean[95%CI]: 852.0 MPa, [809.2-894.7]) was the only group that did not show a significantly different flexural strength than NC (819.8 MPa, [796.6-842.9]), (p > 0.05). All laser groups exhibited higher Weibull moduli than NC and SB, indicating higher reliability and homogeneity of the strength data. An increase of monoclinic phase peak was only observed for SB. CONCLUSION: In conclusion, USPL created predictable, homogeneous, highly reproducible, and accurate surface microstructures on zirconia ceramic. The laser-settings of random-hatching (12 ps pulses) increased 3Y-TZP average surface roughness similarly to SB, while not causing deleterious crystal phase transformation or loss of flexural strength of the material. Furthermore, it has increased the Weibull modulus and consequently material's reliability. CLINICAL SIGNIFICANCE: Picosecond laser microstructuring (LR conditions) of 3Y-TZP ceramic does not decrease its flexural strength, while increasing materials realiability and creating highly reproducible and accurate microstructures. These features may be of interest both for improving clinical survival of zirconia restorations as well as enhancing longevity of zirconia implants.
Assuntos
Resistência à Flexão , Ítrio , Cerâmica , Materiais Dentários , Lasers , Teste de Materiais , Reprodutibilidade dos Testes , Propriedades de Superfície , ZircônioRESUMO
OBJECTIVE: To evaluate the efficacy of Nd:YAG laser associated with calcium-phosphate desensitizing pastes on dentin permeability and tubule occlusion after erosive/abrasive challenges. METHODOLOGY: Dentin specimens were exposed to 17% ethylene diamine tetra-acetic acid (EDTA) solution for 5 min and randomly allocated into five groups: G1, control (no treatment); G2, Nd:YAG laser (1 W, 10 Hz, 100 mJ, 85 J/cm2); G3, Laser + TeethmateTM Desensitizer; G4, Laser + Desensibilize Nano P; and G5, Laser+Nupro®. Specimens underwent a 5-day erosion-abrasion cycling. Hydraulic conductance was measured post-EDTA, post-treatment, and post-cycling. Post-treatment and post-cycling permeability (%Lp) was calculated based on post-EDTA measurements, considered 100%. Open dentin tubules (ODT) were calculated at the abovementioned experimental moments using scanning electron microscopy and ImageJ software (n=10). Data were analyzed using two-way repeated measures ANOVA and Tukey's test (α=0.05). RESULTS: G1 presented the highest %Lp post-treatment of all groups (p<0.05), without significantly differences among them. At post-cycling, %Lp significantly decreased in G1, showed no significant differences from post-treatment in G3 and G4, and increased in G2 and G5, without significant differences from G1 (p>0.05). We found no significant differences in ODT among groups (p>0.05) post-EDTA. At post-treatment, treated groups did not differ from each other, but presented lower ODT than G1 (p<0.001). As for post-cycling, we verified no differences among groups (p>0.05), although ODT was significantly lower for all groups when compared to post-EDTA values (p<0.001). CONCLUSION: All treatments effectively reduced dentin permeability and promoted tubule occlusion after application. COMBINING ND: YAG laser with calcium-phosphate pastes did not improve the laser effect. After erosive-abrasive challenges, treatments presented no differences when compared to the control.
Assuntos
Dessensibilizantes Dentinários , Lasers de Estado Sólido , Cálcio/farmacologia , Dentina , Permeabilidade da Dentina , Lasers de Estado Sólido/uso terapêutico , Microscopia Eletrônica de VarreduraRESUMO
Abstract Objective To evaluate the efficacy of Nd:YAG laser associated with calcium-phosphate desensitizing pastes on dentin permeability and tubule occlusion after erosive/abrasive challenges. Methodology Dentin specimens were exposed to 17% ethylene diamine tetra-acetic acid (EDTA) solution for 5 min and randomly allocated into five groups: G1, control (no treatment); G2, Nd:YAG laser (1 W, 10 Hz, 100 mJ, 85 J/cm2); G3, Laser + TeethmateTM Desensitizer; G4, Laser + Desensibilize Nano P; and G5, Laser+Nupro®. Specimens underwent a 5-day erosion-abrasion cycling. Hydraulic conductance was measured post-EDTA, post-treatment, and post-cycling. Post-treatment and post-cycling permeability (%Lp) was calculated based on post-EDTA measurements, considered 100%. Open dentin tubules (ODT) were calculated at the abovementioned experimental moments using scanning electron microscopy and ImageJ software (n=10). Data were analyzed using two-way repeated measures ANOVA and Tukey's test (α=0.05). Results G1 presented the highest %Lp post-treatment of all groups (p<0.05), without significantly differences among them. At post-cycling, %Lp significantly decreased in G1, showed no significant differences from post-treatment in G3 and G4, and increased in G2 and G5, without significant differences from G1 (p>0.05). We found no significant differences in ODT among groups (p>0.05) post-EDTA. At post-treatment, treated groups did not differ from each other, but presented lower ODT than G1 (p<0.001). As for post-cycling, we verified no differences among groups (p>0.05), although ODT was significantly lower for all groups when compared to post-EDTA values (p<0.001). Conclusion All treatments effectively reduced dentin permeability and promoted tubule occlusion after application. Combining Nd YAG laser with calcium-phosphate pastes did not improve the laser effect. After erosive-abrasive challenges, treatments presented no differences when compared to the control.
Assuntos
Lasers de Estado Sólido/uso terapêutico , Dessensibilizantes Dentinários , Microscopia Eletrônica de Varredura , Cálcio/farmacologia , Dentina , Permeabilidade da DentinaRESUMO
This study aims to evaluate the association between Nd:YAG laser (with and without a photoabsorber) and two desensitizing dentifrices containing 15% NovaMin or 8% arginine, as potential treatments for dentin hypersensitivity (DH). DH was simulated by EDTA application for 2 min. Specimens were then analyzed with an environmental scanning electron microscope (ESEM) to ensure open dentin tubules (ODT), counted by using ImageJ software. Specimens were randomized into eight groups (n = 10): Laser (L), Laser+Photoabsorber (LP), Arginine (A), Arginine+Laser (AL), Arginine+Laser+Photoabsorber (ALP), NovaMin (N), NovaMin+Laser (NL), and NovaMin+Laser+Photoabsorber (NLP). Laser irradiation was performed with 1 W, 100 mJ, 10 Hz, â 85 J/cm2; 4 irradiations of 10 s each, with 10 s intervals between them. After treatment, specimens were again analyzed by ESEM and submitted to erosive/abrasive cycling for 5 days. A final ESEM analysis was performed. Data were analyzed with two-way repeated measure ANOVA and Tukey tests (α = 0.05). After treatment, groups N, NL, and NLP presented the lower number of ODT, but they did not different from LP, ALP, and AL. Group A presented the highest number of ODT and it did not differ from group L. Groups L, AL, ALP, and LP presented intermediate results, without differing from each other. After cycling, group A presented the highest number of ODT and did not differ significantly from the other groups, except NLP. None of the associations tested presented better tubule occlusion than NovaMin by itself. Arginine was the only treatment that presented improved tubule occlusion when associated with Nd:YAG laser.
Assuntos
Dentifrícios/efeitos da radiação , Dessensibilizantes Dentinários/farmacologia , Sensibilidade da Dentina/radioterapia , Lasers de Estado Sólido/uso terapêutico , Dentina/efeitos da radiação , Dentina/ultraestrutura , Vidro , HumanosRESUMO
INTRODUCTION: In response to the growing body of evidence that simulation is a satisfactory way to instruct procedural skills, we developed an innovative model to teach common gynecologic procedures such as cervical cancer screening, cervical polyp removal, intrauterine device removal, and endometrial biopsy. The objectives of this study were to describe the construction of the model and to assess participants' satisfaction and confidence in applying the learning objectives to their clinical practice. METHODS: The researchers created the model with reusable and readily available materials. During a hands-on skills workshop, practicing clinicians performed simulated cervical cancer screening, endocervical polyp removal, intrauterine device removal, and an endometrial biopsy on a low-fidelity gynecologic model. Using convenience sampling, each participant completed a survey designed to measure satisfaction with the workshop and self-confidence in their newly acquired skills. RESULTS: All (N = 30,100%) of the participants agreed at the "agree" or "strongly agree" level that the gynecologic skills workshop using lecture and a hands-on model was a satisfying and self-confidence-building experience. CONCLUSIONS: An easily reproducible and reusable gynecologic procedure simulator was highly rated as a means of teaching common primary care gynecologic procedures. The simulated model provided an opportunity for hands-on skills learning for clinicians who wish to expand their gynecologic procedure skill set.