Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
São Paulo; s.n; 20180000. 71 p.
Tese em Português | BBO - Odontologia | ID: biblio-997172

RESUMO

Objetivo: O objetivo do presente estudo foi avaliar in vitro a precisão dos contatos oclusais obtidos em pacientes dentados por meio do articulador virtual. Materiais e Métodos: Trinta e seis modelos foram obtidos de pacientes dentados e montados em articulador semi ajustavel (ASA) A7 Plus (Bio-art). O registo intermaxilar foi realizado utilizando silicone occlufast Rock (Zhermack). Após a montagem em articulador, os contatos oclusais foram demarcados nos modelos de gesso com carbono de 20 ?m de espessura (AccuFilm), os quais foram utilizados como valores de referência. Com o intuito de obter modelos virtuais, os modelos de gesso foram então digitalizados por meio de um scanner laboratorial (Dental Wings 7, Straumann). Realizou-se a calibração do articulador virtual de acordo com as recomendações do fabricante e os contatos oclusais nos modelos digitais foram obtidos automaticamente por meio do respectivo software. A análise quantitativa dos contatos oclusais foi realizada independentemente por dois examinadores, de forma que cada examinador repetiu a contagem duas vezes com um intervalo de 48h entre as medições. A concordância intra e inter examinadores, assim como a correlação entre os contatos oclusais obtidos em modelos virtuais e modelos de gesso foram avaliados estatisticamente por meio do coeficiente Kappa com nível de significância ? = 5%. A concordância intra-examinador foi de 0.93 a 0.98 (p < 0,001), enquanto que a concordância entre os examinadores variou entre 0.61 a 0.67 (p < 0,001) para ambos modelos virtuais e de gesso. Os contatos obtidos em modelos virtuais e modelos de gesso convencionais apresentaram uma concordância entre 0.52 a 0.55 (p < 0,001). Conclusão: Dentre as limitações apresentadas pelo presente estudo, foi possível concluir que o articulador virtual apresentou uma precisão moderada para a determinação dos contatos oclusais em pacientes dentados.


Assuntos
Desenho Assistido por Computador , Articuladores Dentários , Oclusão Dentária
2.
Rev. Fac. Odontol. Univ. Antioq ; 27(1): 76-85, July-Dec. 2015. tab, graf
Artigo em Inglês | LILACS | ID: biblio-957204

RESUMO

ABSTRACT. Introduction: currently, resin composites are the materials of most frequent use in dentistry. The purpose of this study was to evaluate the level of microleakage in direct composite restorations. Methods: 60 recently extracted third molars were collected and sorted out into three groups. Two cavities were prepared on each tooth, one in the buccal surface and one in the lingual surface. The same composite (Vococid Gel, Admira Bond and admires A2 - Voco) was used to perform the restorations of all the cavities, closely following the manufacturer′s recommendations. The samples were sorted out into three groups (n= 20) according to different thermocycling times. Group 1: 5,400 cycles during 6 months; Group 2: 8,100 cycles during 9 months; Group 3: 10,800 cycles during 12 months, at a temperature of 5, 37, and 55°C respectively. The entire surface of each sample was isolated with the exception of 2 mm around the restoration, and then they were pigmented with methylene blue for 24 hours. Next, each sample was longitudinally cut in order to evaluate the degree of microleakage. Results: the collected data were subjected to ANOVA, Tukey, and Student′s t-test, finding out p<0.05, which suggests that there is no significant difference among the thermocycling times. Conclusions: the results show that the restorative material under evaluation has dimensional stability 6, 9, and 12 months after application.


RESUMEN Introducción: los composites en la actualidad constituyen la primera elección como material restaurador, es así, que el propósito de esta investigación fue evaluar el grado de microfiltración de este material variando el tiempo tras su empleo en restauraciones directas. Métodos: en 60 terceros molares humanos de reciente extracción se realizaron dos cavidades, una en la cara vestibular y otra en la cara palatina/lingual. Las mismas que fueron restauradas mediante un único material y mismo protocolo restaurador (Vococid Gel, Admira Bond y Admira A2 - Voco) tras haber seguido las indicaciones del fabricante. Los cuerpos de prueba (n=20) fueron divididos en tres grupos según tiempos de termociclado: G1 de 5.400 ciclos proporcional a 6 meses, G2 de 8.100 ciclos equivalente a 9 meses, y G3 de 10.800 ciclos proporcional a 12 meses, a una temperatura que varía de 5°C, 37°C y 55°C. En cada cuerpo de prueba se realizó un vedamiento de toda su superficie excepto alrededor de dos mm de la restauración. Se prosigue a pigmentarlas con Azul de Metileno durante 24 horas, después de este tiempo se procede a la selección longitudinal para iniciar el análisis de grado de microfiltración. Resultados: los datos recolectados fueron sometidos a pruebas ANOVA, Tukey y T de Student encontrando un p<0,05 que permite determinar ausencia de diferencia significativa entre los tiempos de termociclado. Conclusiones: se evidencia una clara estabilidad dimensional en el material restaurador testado a los 6, 9 y 12 meses después de su confección.


Assuntos
Restauração Dentária Permanente , Resinas Sintéticas , Micropeneiramento , Longevidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA